872 resultados para Validation of test results


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In vitro release of bioidentical hormones in four different liposomal transdermal emulsions (containing testosterone, progesterone, estradiol, or estradiol and estriol) was assessed. For this purpose, novel high-performance liquid chromatography methods were developed and validated in an eco-friendly manner and used to determine the in vitro release of such products. The methods were suitable for our intended goal, and the emulsions employed were found to be effective as transporting candidates for the efficient release of hormones in the transdermal delivery of human sexual steroids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Xanthyletin is used as an inhibitor of the symbiotic fungus (Leucoagaricus gongylophorus) of the leaf-cutting ant (Atta sexdens rubropilosa), one of the most significant agricultural plague insects. The incorporation of this compound into nanoparticles is a promising approach to effectively control leaf-cutting ants. This study presents the development and validation of a specific analytical method using high-performance liquid chromatography (HPLC) for quantification of the xanthyletin content in biodegradable polymeric nanoparticles. The analytical methodology developed was specific, linear, accurate, precise, and robust. The absolute recovery of xanthyletin in colloidal suspensions was nearly 100%. The HPLC method proved reliable for the quantification of xanthyletin content in nanoparticle formulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The microencapsulation of palm oil may be a mechanism for protecting and promoting the controlled release of its bioactive compounds. To optimize the microencapsulation process, it is necessary to accurately quantify the palm oil present both external and internal to the microcapsules. In this study, we developed and validated a spectrophotometric method to determine the microencapsulation efficiency of palm oil by complex coacervation. We used gelatin and gum arabic (1:1) as wall material in a 5% concentration (w/v) and palm oil in the same concentration. The coacervates were obtained at pH 4.0 ± 0.01, decanted for 24 h, frozen (−40 ºC), and lyophilized for 72 h. Morphological analyzes were then performed. We standardized the extraction of the external palm oil through five successive washes with an organic solvent. We then explored the best method for rupturing the microcapsules. After successive extractions with hexane, we determined the amount of palm oil contained in the microcapsules using a spectrophotometer. The proposed method was shown to be of low cost, fast, and easy to implement. In addition, in the validation step, we confirmed the method to be safe and reliable, as it proved to be specific, accurate, precise, and robust.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, sensitive and reproducible spectrophotometric method was developed for the determination of sitagliptin phosphate in bulk and in pharmaceutical formulations. The proposed method is based on condensation of the primary amino group of sitagliptin phosphate with acetyl acetone and formaldehyde producing a yellow colored product, which is measured spectrophotometrically at 430nm. The color was stable for about 1 hour. Beer's law is obeyed over a concentration range of 5-25 µg/ml. The apparent molar absorptivity and Sandell sensitivity values are 1.067 x 10(4) Lmol-1cm-1 and 0.0471 µgcm-2 respectively. All the variables were studied to optimize the reaction conditions. No interference was observed in the presence of common pharmaceutical excipients. The validity of the method was tested by analyzing sitagliptin phosphate in its pharmaceutical preparations. Good recoveries were obtained. The developed method was successfully employed for the determination of sitagliptin phosphate in various pharmaceutical preparations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most warning systems for plant disease control are based on Vinho, in Bento Gonçalves - RS, during the growing seasons 2000/ weather models dependent on the relationships between leaf wetness 01, 2002/03 and 2003/2004, using the grape cultivar Isabel. The duration and mean air temperature in this period considering the conventional system used by local growers was compared with the target disease intensity. For the development of a warning system to new warning system by using different cumulative daily disease severity control grapevine downy mildew, the equation generated by Lalancette values (CDDSV) as the criterion to schedule fungicide application and et al. (7) was used. This equation was employed to elaborate a critical reapplication. In experiments conducted in 2003/04, CDDSV of 12 - period table and program a computerized device, which records, though 14 showed promising to schedule the first spraying and the interval electronic sensors, leaf wetness duration, mean temperature in this between fungicide applications, reducing by 37.5% the number of period and automatically calculates the daily value of probability of applications and maintaining the same control efficiency in leaves infection occurrence. The system was validated at Embrapa Uva e and bunches, similarly to the conventional system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pentti Vattulaisen esitys Kohti aineistojen yhteiskäyttöä -seminaarissa 2.11.2011 Helsingissä

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aims of this study were to validate an international Health-Related Quality of Life (HRQL) instrument, to describe child self and parent-proxy assessed HRQL at child age 10 to 12 and to compare child self assessments with parent-proxy assessments and school nursing documentation. The study is part of the Schools on the Move –research project. In phase one, a cross-cultural translation and validation process was performed to develop a Finnish version of Pediatric Quality of Life Inventory™ 4.0 (PedsQL™ 4.0). The process included a two-way translation, cognitive interviews (children n=7, parents n=5) and a survey (children n=1097, parents n=999). In phase two, baseline and follow-up surveys (children n=986, parents n=710) were conducted to describe and compare the child self and parent-proxy assessed HRQL in school children between the ages 10 and 12. Phase three included two separate data, school nurse documented patient records (children n=270) and a survey (children n=986). The relation between child self assessed HRQL and school nursing documentation was evaluated. Validity and reliability of the Finnish version of PedsQL™ 4.0 was good (Child Self Report α=0.91, Parent-Proxy Report α=0.88). Children reported lower HRQL scores at the emotional (mean 76/80) than the physical (mean 85/89) health domains and significantly lower scores at the age of 10 than 12 (dMean=4, p=<0.001). Agreement between child self and parent-proxy assessment was fragile (r=0,4, p=<0.001) but increased as the child grew from age 10 to 12 years. At health check-ups, school nurses documented frequently children’s physical health, such as growth (97%) and posture (98/99%) but seldom emotional issues, such as mood (2/7%). The PedsQLTM 4.0 is a valid instrument to assess HRQL in Finnish school children although future research is recommended. Children’s emotional wellbeing needs future attention. HRQL scores increase during ages between childhood and adolescence. Concordance between child self and parent-proxy assessed HRQL is low. School nursing documentation, related to child health check-ups, is not in line with child self assessed HRQL and emotional issues need more attention.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the results of subcostal incisional hernia repair using polypropylene mesh, the technical aspects of musculo-aponeurotic reconstruction, routine fixation of supra-aponeurotic mesh and follow-up for five years.METHODS: We conducted a retrospective study that assessed 24 patients undergoing subcostal incisional hernia repair with use of polypropylene mesh; 15 patients (62.5%) were female; ages ranged from 33 to 82, and 79.1% had comorbidities.RESULTS: Early complications: three cases (12.5%) of wound infection, three cases (12.5%) of seroma, one case (4.1%) of hematoma; and one case (4.1%) of wound dehiscence. Late complications occurred in one case (4.1%) of hernia recurrence attributed to technical failure in the fixation of the mesh and in one case (4.1%) of chronic pain. There were no cases of exposure or rejection of the mesh.CONCLUSION: The subcostal incisional hernia, though not very relevant, requires adequate surgical treatment. Its surgical correction involves rebuilding the muscle-aponeurotic defect, supra-aponeurotic fixation of polypropylene mesh, with less complexity and lower rates of complications and recurrences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to optimize and validate the solid-liquid extraction (ESL) technique for determination of picloram residues in soil samples. At the optimization stage, the optimal conditions for extraction of soil samples were determined using univariate analysis. Ratio soil/solution extraction, type and time of agitation, ionic strength and pH of extraction solution were evaluated. Based on the optimized parameters, the following method of extraction and analysis of picloram was developed: weigh 2.00 g of soil dried and sieved through a sieve mesh of 2.0 mm pore, add 20.0 mL of KCl concentration of 0.5 mol L-1, shake the bottle in the vortex for 10 seconds to form suspension and adjust to pH 7.00, with alkaline KOH 0.1 mol L-1. Homogenate the system in a shaker system for 60 minutes and then let it stand for 10 minutes. The bottles are centrifuged for 10 minutes at 3,500 rpm. After the settlement of the soil particles and cleaning of the supernatant extract, an aliquot is withdrawn and analyzed by high performance liquid chromatography. The optimized method was validated by determining the selectivity, linearity, detection and quantification limits, precision and accuracy. The ESL methodology was efficient for analysis of residues of the pesticides studied, with percentages of recovery above 90%. The limits of detection and quantification were 20.0 and 66.0 mg kg-1 soil for the PVA, and 40.0 and 132.0 mg kg-1 soil for the VLA. The coefficients of variation (CV) were equal to 2.32 and 2.69 for PVA and TH soils, respectively. The methodology resulted in low organic solvent consumption and cleaner extracts, as well as no purification steps for chromatographic analysis were required. The parameters evaluated in the validation process indicated that the ESL methodology is efficient for the extraction of picloram residues in soils, with low limits of detection and quantification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present study was to validate the transit-time technique for long-term measurements of iliac and renal blood flow in rats. Flow measured with ultrasonic probes was confirmed ex vivo using excised arteries perfused at varying flow rates. An implanted 1-mm probe reproduced with accuracy different patterns of flow relative to pressure in freely moving rats and accurately quantitated the resting iliac flow value (on average 10.43 ± 0.99 ml/min or 2.78 ± 0.3 ml min-1 100 g body weight-1). The measurements were stable over an experimental period of one week but were affected by probe size (resting flows were underestimated by 57% with a 2-mm probe when compared with a 1-mm probe) and by anesthesia (in the same rats, iliac flow was reduced by 50-60% when compared to the conscious state). Instantaneous changes of iliac and renal flow during exercise and recovery were accurately measured by the transit-time technique. Iliac flow increased instantaneously at the beginning of mild exercise (from 12.03 ± 1.06 to 25.55 ± 3.89 ml/min at 15 s) and showed a smaller increase when exercise intensity increased further, reaching a plateau of 38.43 ± 1.92 ml/min at the 4th min of moderate exercise intensity. In contrast, exercise-induced reduction of renal flow was smaller and slower, with 18% and 25% decreases at mild and moderate exercise intensities. Our data indicate that transit-time flowmetry is a reliable method for long-term and continuous measurements of regional blood flow at rest and can be used to quantitate the dynamic flow changes that characterize exercise and recovery

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A gravimetric method was evaluated as a simple, sensitive, reproducible, low-cost alternative to quantify the extent of brain infarct after occlusion of the medial cerebral artery in rats. In ether-anesthetized rats, the left medial cerebral artery was occluded for 1, 1.5 or 2 h by inserting a 4-0 nylon monofilament suture into the internal carotid artery. Twenty-four hours later, the brains were processed for histochemical triphenyltetrazolium chloride (TTC) staining and quantitation of the schemic infarct. In each TTC-stained brain section, the ischemic tissue was dissected with a scalpel and fixed in 10% formalin at 0ºC until its total mass could be estimated. The mass (mg) of the ischemic tissue was weighed on an analytical balance and compared to its volume (mm³), estimated either by plethysmometry using platinum electrodes or by computer-assisted image analysis. Infarct size as measured by the weighing method (mg), and reported as a percent (%) of the affected (left) hemisphere, correlated closely with volume (mm³, also reported as %) estimated by computerized image analysis (r = 0.88; P < 0.001; N = 10) or by plethysmography (r = 0.97-0.98; P < 0.0001; N = 41). This degree of correlation was maintained between different experimenters. The method was also sensitive for detecting the effect of different ischemia durations on infarct size (P < 0.005; N = 23), and the effect of drug treatments in reducing the extent of brain damage (P < 0.005; N = 24). The data suggest that, in addition to being simple and low cost, the weighing method is a reliable alternative for quantifying brain infarct in animal models of stroke.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acute otitis media (AOM) is the most prevalent bacterial infection among children. Tympanometry and spectral gradient acoustic reflectometry (SG-AR) are adjunctive diagnostic tools to pneumatic otoscopy. The aim was to investigate the diagnostic accuracy and success rates of tympanometry and SG-AR performed by physicians and nurses. The study populations comprised 515 (I-II), 281 (III), and 156 (IV) outpatients (6-35 months). Physicians performed 4246 tympanometric (I) and SG-AR (II) examinations. Nurses performed 1782 (III) and 753 (IV) examinations at symptomatic and asymptomatic visits, respectively. Pneumatic otoscopy by the physician was the diagnostic standard. The accuracy of test results by physicians or nurses (I-IV) and the proportion of visits with accurate exclusive test results from both ears (III-IV) were analyzed. Type B tympanogram and SG-AR level 5 (<49˚) predicted middle ear effusion (MEE). At asymptomatic visits, type A and C1 tympanograms (peak pressure > -200 daPa) and SG-AR level 1 (>95˚) indicated healthy middle ear. Negative predictive values of type A and C1 tympanograms by nurses in excluding AOM at symptomatic and MEE at asymptomatic visits were 94% and 95%, respectively. Nurses obtained type A or C1 tympanogram from both ears at 94/459 (20%) and 81/196 (41%) of symptomatic and asymptomatic visits, respectively. SG-AR level 1 was rarely obtained from both ears. Type A and C1 tympanograms were accurate in excluding AOM at symptomatic and MEE at asymptomatic visits. However, nurses obtained these tympanograms from both ears only at one fifth of symptomatic visits and less than half of asymptomatic visits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Progressive myelopathies can be secondary to inborn errors of metabolism (IEM) such as mucopolysaccharidosis, mucolipidosis, and adrenomyeloneuropathy. The available scale, Japanese Orthopaedic Association (JOA) score, was validated only for degenerative vertebral diseases. Our objective is to propose and validate a new scale addressing progressive myelopathies and to present validating data for JOA in these diseases. A new scale, Severity Score System for Progressive Myelopathy (SSPROM), covering motor disability, sphincter dysfunction, spasticity, and sensory losses. Inter- and intra-rater reliabilities were measured. External validation was tested by applying JOA, the Expanded Disability Status Scale (EDSS), the Barthel index, and the Osame Motor Disability Score. Thirty-eight patients, 17 with adrenomyeloneuropathy, 3 with mucopolysaccharidosis I, 3 with mucopolysaccharidosis IV, 2 with mucopolysaccharidosis VI, 2 with mucolipidosis, and 11 with human T-cell lymphotropic virus type-1 (HTLV-1)-associated myelopathy participated in the study. The mean ± SD SSPROM and JOA scores were 74.6 ± 11.4 and 12.4 ± 2.3, respectively. Construct validity for SSPROM (JOA: r = 0.84, P < 0.0001; EDSS: r = -0.83, P < 0.0001; Barthel: r = 0.56, P < 0.002; Osame: r = -0.94, P < 0.0001) and reliability (intra-rater: r = 0.83, P < 0.0001; inter-rater: r = 0.94, P < 0.0001) were demonstrated. The metric properties of JOA were similar to those found in SSPROM. Several clinimetric requirements were met for both SSPROM and JOA scales. Since SSPROM has a wider range, it should be useful for follow-up studies on IEM myelopathies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hepatitis E virus (HEV) is classified within the family Hepeviridae, genus Hepevirus. HEV genotype 3 (Gt3) infections are endemic in pigs in Western Europe and in North and South America and cause zoonotic infections in humans. Several serological assays to detect HEV antibodies in pigs have been developed, at first mainly based on HEV genotype 1 (Gt1) antigens. To develop a sensitive HEV Gt3 ELISA, a recombinant baculovirus expression product of HEV Gt3 open reading frame-2 was produced and coated onto polystyrene ELISA plates. After incubation of porcine sera, bound HEV antibodies were detected with anti-porcine anti-IgG and anti-IgM conjugates. For primary estimation of sensitivity and specificity of the assay, sets of sera were used from pigs experimentally infected with HEV Gt3. For further validation of the assay and to set the cutoff value, a batch of 1100 pig sera was used. All pig sera were tested using the developed HEV Gt3 assay and two other serologic assays based on HEV Gt1 antigens. Since there is no gold standard available for HEV antibody testing, further validation and a definite setting of the cutoff of the developed HEV Gt3 assay were performed using a statistical approach based on Bayes' theorem. The developed and validated HEV antibody assay showed effective detection of HEV-specific antibodies. This assay can contribute to an improved detection of HEV antibodies and enable more reliable estimates of the prevalence of HEV Gt3 in swine in different regions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method using Liquid Chromatography Tanden Mass Spectrometry (LC-MS/MS) with matrix-matched calibration curve was developed and validated for determining ochratoxin A (OTA) in green coffee. Linearity was found between 3.0 and 23.0 ng.g-1. Mean recoveries ranged between 90.45% and 108.81%; the relative standard deviation under repeatability and intermediate precision conditions ranged from 5.39% to 9.94% and from 2.20% to 14.34%, respectively. The limits of detection and quantification were 1.2 ng.g-1 and 3.0 ng.g-¹, respectively. The method developed was suitable and contributed to the field of mycotoxin analysis, and it will be used for future production of the Certified Reference Material (CRM) for OTA in coffee.