924 resultados para Tricuspid valve
Resumo:
After 75 years of invasive and over 50 years of interventional cardiology, cardiac catheter-based procedures have become the most frequently used interventions of modern medicine. Patients undergoing a percutaneous coronary intervention (PCI) outnumber those with coronary artery bypass surgery by a factor of 2 to 4. The default approach to PCI is the implantation of a (drug-eluting) stent, in spite of the fact that it improves the results of balloon angioplasty only in about 25% of cases. The dominance of stenting over conservative therapy or balloon angioplasty on one hand and bypass surgery on the other hand is a flagrant example of how medical research is digested an applied in real life. Apart from electrophysiological interventions, closure ot the patent foramen ovale and percutaneous replacement of the aortic valve in the elderly have the potential of becoming daily routine procedures in catheterization laboratories around the world. Stem cell regeneration of vessels or heart muscle, on the other hand, may remain a dream never to come true.
Resumo:
OBJECTIVE: Assessment of postoperative quality of life in patients over 80 years after cardiac surgery including coronary artery bypass grafting (CABG), aortic valve replacement (AVR) and combined procedures. METHODS: Quality of life of n=136 patients over 80 years at operation (82.3+/-2.1 years), undergoing isolated CABG in 61 patients (45%), isolated AVR in 34 patients (25%) and a combination of CABG and AVR in 41 patients (30%) between January 1999 and December 2003 was reviewed. Preoperatively 66.2% presented in NYHA-class III/IV or CCS-class III/IV. Mean ejection fraction (EF) was 59.5%+/-14.0 (range 25-90%). Quality of life assessment was performed via a Seattle Angina Questionnaire. Follow-up was 100% complete for a total of 890 days (69-1853 days). RESULTS: Five-year survival was 70% for the CABG group, 75% for the AVR group and 65% for the CABG/AVR group. Quality of life was remarkable in all of the three groups after surgery. Overall 97 patients (81%) were not or little disabled in their daily activity. One hundred and twelve patients (93%) were free or considerably less symptomatic. Seventy-eight patients or 65% reported to be very satisfied with their current quality of life and 112 patients (93%) felt very reassured to have continuous full access to medical treatment despite of their advanced age. CONCLUSIONS: A remarkable quality of life and important improvement in the functional status after cardiac surgery in patients over 80 paired with a satisfactory medium-term survival justify early intervention for heart disease in this age group. Therefore, referral practice for patients over 80 years for heart surgery should be handled liberally.
Resumo:
The chest X-ray of a 61-year-old man with severe aortic and mitral stenosis revealed extensive, circularly arranged calcifications in the wall of the left atrial appendage. He died soon after admission to hospital and autopsy confirmed the atrial calcifications in association with severe mitral stenosis. Although such calcification of the left atrial wall is rare, it can be of importance because it may make the usual surgical approach to mitral valve replacement impossible.
Resumo:
BACKGROUND: Different studies have analyzed the potential impact of the underlying pathologic process and the use of deep hypothermic circulatory arrest on outcome and quality of life after surgery on the thoracic aorta. The aim of this study is to analyze the impact of different surgical procedures on outcome and quality of life. METHODS: Between June 2001 and December 2003, 244 patients underwent surgery for various diseases of the ascending aorta with or without involvement of the aortic valve or root. They were divided according to the operative procedure: 76 patients (31.2%) underwent isolated replacement of the ascending aorta, 42 patients (17.2%) received separate aortic valve replacement and supracoronary replacement of the ascending aorta, 86 patients (35.2%) received a mechanical composite graft, and 40 patients (16.4%) received a biologic composite graft. All in-hospital data were assessed, and a follow-up was performed in all survivors after 26.6 +/- 8.8 months, focusing on outcome and quality of life (SF-36). RESULTS: Overall in-hospital mortality was 6.1%, and late mortality was 5.7%, with no significant difference between groups. Independent of the surgical technique and the extent of surgery, there was no difference in quality of life between the surgical collective and an age-matched and sex-matched standard population. CONCLUSIONS: Operations of the ascending aorta and aortic valve are very safe, with low in-hospital mortality and favorable midterm outcome regarding late mortality and morbidity. Quality of life after operations of the ascending aorta and aortic valve is equal to a standard population and is not affected by the surgical procedure. Liberal use of aortic root replacement is therefore justified to radically treat the diseased aortic segment.
Resumo:
OBJECTIVES: To evaluate the efficacy of stent placement after infrainguinal loco-regional thrombolysis and iliac thrombectomy (surgical TT) of acute deep vein thrombosis (DVT) in patients with May-Thurner-Syndrome. MATERIAL AND METHODS: We retrospectively analysed a group of 11 patients (9 women) (mean age 34 years, range 16-64 years) with surgical TT and additional intra-operative stenting due to compression of the common iliac vein. Patients underwent venography to demonstrate outflow patency after surgical TT, and to identify any obstruction at the level of the left-sided common iliac vein ("Beckenvenen-Sporn"). Obstruction at the level of arterial crossing was treated using Wallstents placed via an introducer sheath from the inguinal access site. Stents were fully deployed using balloons adjusted to the size of vein. Patients were treated with oral anticoagulants for 6 months, and followed using duplex ultrasonography. RESULTS: Technical success defined as complete vein patency and normal valve function was documented in all 11 patients. One patient needed early stent extension due to residual stenosis. At 6 months follow-up one patient (9%) had an asymptomatic occlusion of the stented common iliac vein. In all 11/11 (100%) patients the femoral segment was found to be patent, and in 1/11 (9%) there was mild reflux with few clinical symptoms of post-thrombotic syndrome. The calculated cumulative primary patency rate for venous iliac stents was 82%, and assisted patency rate was 91%, which remained unchanged over a mean follow-up of 22 months. CONCLUSION: Combining surgical TT and stenting of common iliac vein obstructions in DVT is safe, effective, and results in a acceptable venous patency.
Resumo:
Although platelets are a major factor in the pathogenesis of endocarditis, it is unclear if these cells promote or limit disease progression. To address this issue, the effects of thrombocytopenia on the early course of endovascular infection were examined. Aortic valve endocarditis was produced in rabbits by using Streptococcus sanguis M99. Thrombocytopenia was induced by intravenous administration of antiplatelet serum. Compared with controls (infected rabbits given nonimmune serum), thrombocytopenic rabbits had higher densities of streptococci within vegetations (mean log10 cfu/g, 9.78 vs. 8.11, P < .002) and a higher total number of bacteria per valve (mean log10 total cfu/valve, 8.96 vs. 7.43, P < .004). When tested for its interactions with platelets in vitro, strain M99 bound, activated, and aggregated rabbit platelets extensively and was rapidly killed by platelet microbicidal protein. These results indicate that platelets can limit disease progression in endocarditis. The host defense properties of platelets may in part be mediated by platelet microbicidal protein.
Resumo:
We describe the case of a 59-year-old man who had aortic regurgitation and a hypoplastic aortic valve and for whom an echocardiography evaluation revealed a vascular tumor in the roof of the left atrium, which was suspected to be a hemangioma. After undergoing preoperative invasive catheter coronary angiography, echocardiography, and multislice computed tomography examinations, the patient underwent an aortic miniroot replacement. Intraoperative findings confirmed the findings of the preoperative evaluations. The tumor, although macroscopically verified as a hemangioma, was not resected because of the tumor's position and size, and the threat of uncontrollable bleeding. After an uneventful postoperative clinical course, a subsequent successful transcatheter coil occlusion of the coronary fistula from the left circumflex coronary artery was performed as an alternative to surgical resection of the tumor. This case emphasizes the future role of a multimodality hybrid approach for diagnosis, planning (different 2- and 3-dimensional imaging modalities), and treatment in the form of combining interventional (transcatheter) and surgical (open heart) techniques, which could optimize different treatment strategies. This approach could be further improved by increasing the installations of hybrid operating rooms.
Resumo:
OBJECTIVE: The Ross operation remains a controversially discussed procedure, because concern exists regarding late dilatation of the neoaortic root and progressive regurgitation of the autograft valve. We present our early experience with an external reinforcement of the autograft, which is inserted into a prosthetic Dacron graft with an artificial aortic root configuration. This detail should help to prevent neoaortic root dilatation. PATIENTS AND METHODS: Between 2006 and 2007, 12 patients (mean age 16 +/- 38 years; range 15-38 years) underwent a Ross procedure by this technique. Indications were aortic regurgitation (n = 2), aortic stenosis (n = 5), and combined aortic stenosis and insufficiency (n = 5). A bicuspid aortic valve was present in 9 patients. Balloon valvuloplasty had been performed in 7 patients. Follow-up was performed by clinical and echocardiographic examinations. RESULTS: No early or late deaths occurred in this small series, and freedom from reoperation is 100%. Echocardiographic follow-up confirmed absence of aortic insufficiency in 11 patients after a mean of 11 months (range 2-30 months). In 1 patient, a small asymmetric regurgitation jet was already observed at discharge echocardiography. As expected, no neoaortic root dilatation was observed during follow-up. All patients are in New York Heart Association class I. CONCLUSIONS: The present technique is a simple and reproducible technical step that does not require significant additional time. Inclusion of the autograft within a root prosthesis may be especially indicated in situations known for late autograft dilatation, namely, bicuspid aortic valve, predominant aortic insufficiency, and ascending aortic enlargement.
Resumo:
Recently nanoscale junctions consisting of 0-D nanostructures (single molecule) or 1-D nanostructures (semiconducting nanowire) sandwiched between two metal electrodes are successfully fabricated and characterized. What lacks in the recent developments is the understanding of the mechanism behind the observed phenomena at the level of atoms and electrons. For example, the origin of observed switching effect in a semiconducting nanowire due to the influence of an external gate bias is not yet understood at the electronic structure level. On the same context, different experimental groups have reported different signs in tunneling magneto-resistance for the same organic spin valve structure, which has baffled researchers working in this field. In this thesis, we present the answers to some of these subtle questions by investigating the charge and spin transport in different nanoscale junctions. A parameter-free, single particle Green’s function approach in conjunction with a posteriori density functional theory (DFT) involving a hybrid orbital dependent functional is used to calculate the tunneling current in the coherent transport limit. The effect of spin polarization is explicitly incorporated to investigate spin transport in a nanoscale junction. Through the electron transport studies in PbS nanowire junction, a new orbital controlled mechanism behind the switching of the current is proposed. It can explain the switching behavior, not only in PbS nanowire, but in other lead-chalcogenide nanowires as well. Beside this, the electronic structure properties of this nanowire are studied using periodic DFT. The quantum confinement effect was investigated by calculating the bandgap of PbS nanowires with different diameters. Subsequently, we explain an observed semiconducting to metallic phase transition of this nanowire by calculating the bandgap of the nanowire under uniform radial strain. The compressive radial strain on the nanowire was found to be responsible for the metallic to semiconducting phase transition. Apart from studying one dimensional nanostructure, we also present transport properties in zero dimensional single molecular junctions. We proposed a new codoping approach in a single molecular carborane junction, where a cation and an anion are simultaneously doped to find the role of a single atom in the device. The main purpose was to build a molecular junction where a single atom can dictate the flow of electrons in a circuit. Recent observations of both positive and negative sign in tunneling magnetoresistance (TMR) the using same organic spin-valve structure hasmystified researchers. From our spin dependent transport studies in a prototypical organic molecular tunneling device, we found that a 3% change in metal-molecule interfacial distance can alter the sign of TMR. Changing the interfacial distance by 3%, the number of participating eigenstates as well as their orbital characteristic changes for anti-parallel configuration of the magnetization at the two electrodes, leading to the sign reversal of the TMR. Apart from this, the magnetic proximity effect under applied bias is investigated quantitatively, which can be used to understand the observed unexpectedmagnetismin carbon basedmaterials when they are in close proximity with magnetic substrates.
Resumo:
The reserves of gasoline and diesel fuels are ever decreasing, which plays an important role in the technological development of automobiles. Numerous countries, especially the United States, wish to slowly decrease their fuel dependence on other countries by producing in house renewable fuels like biodiesels or ethanol. Therefore, the new automobile engines have to successfully run on a variety of fuels without significant changes to their designs. The current study focuses on assessing the potential of ethanol fuels to improve the performance of 'flex-fuel SI engines,' which literally means 'engines that are flexible in their fuel requirement.' Another important area within spark ignition (SI) engine research is the implementation of new technologies like Variable Valve Timing (VVT) or Variable Compression Ratio (VCR) to improve engine performance. These technologies add more complexity to the original system by adding extra degrees of freedom. Therefore, the potential of these technologies has to be evaluated before they are installed in any SI engine. The current study focuses on evaluating the advantages and drawbacks of these technologies, primarily from an engine brake efficiency perspective. The results show a significant improvement in engine efficiency with the use of VVT and VCR together. Spark ignition engines always operate at a lower compression ratio as compared to compression ignition (CI) engines primarily due to knock constraints. Therefore, even if the use of a higher compression ratio would result in a significant improvement in SI engine efficiency, the engine may still operate at a lower compression ratio due to knock limitations. Ethanol fuels extend the knock limit making the use of higher compression ratios possible. Hence, the current study focuses on using VVT, VCR, and ethanol-gasoline blends to improve overall engine performance. The results show that these technologies promise definite engine performance improvements provided both their positive and negative potentials have been evaluated prior to installation.
Resumo:
KIVA is an open Computational Fluid Dynamics (CFD) source code that is capable to compute the transient two and three-dimensional chemically reactive fluid flows with spray. The latest version in the family of KIVA codes is the KIVA-4 which is capable of handling the unstructured mesh. This project focuses on the implementation of the Conjugate Heat Transfer code (CHT) in KIVA-4. The previous version of KIVA code with conjugate heat transfer code has been developed at Michigan Technological University by Egel Urip and is be used in this project. During the first phase of the project, the difference in the code structure between the previous version of KIVA and the KIVA-4 has been studied, which is the most challenging part of the project. The second phase involves the reverse engineering where the CHT code in previous version is extracted and implemented in KIVA-4 according to the new code structure. The validation of the implemented code is performed using a 4-valve Pentroof engine case. A solid cylinder wall has been developed using GRIDGEN which surrounds 3/4th of the engine cylinder and heat transfer to the solid wall during one engine cycle (0-720 Crank Angle Degree) is compared with that of the reference result. The reference results are nothing but the same engine case run in the previous version with the original code developed by Egel. The results of current code are very much comparable to that of the reference results which verifies that successful implementation of the CHT code in KIVA-4.
Resumo:
The remarkable advances in nanoscience and nanotechnology over the last two decades allow one to manipulate individuals atoms, molecules and nanostructures, make it possible to build devices with only a few nanometers, and enhance the nano-bio fusion in tackling biological and medical problems. It complies with the ever-increasing need for device miniaturization, from magnetic storage devices, electronic building blocks for computers, to chemical and biological sensors. Despite the continuing efforts based on conventional methods, they are likely to reach the fundamental limit of miniaturization in the next decade, when feature lengths shrink below 100 nm. On the one hand, quantum mechanical efforts of the underlying material structure dominate device characteristics. On the other hand, one faces the technical difficulty in fabricating uniform devices. This has posed a great challenge for both the scientific and the technical communities. The proposal of using a single or a few organic molecules in electronic devices has not only opened an alternative way of miniaturization in electronics, but also brought up brand-new concepts and physical working mechanisms in electronic devices. This thesis work stands as one of the efforts in understanding and building of electronic functional units at the molecular and atomic levels. We have explored the possibility of having molecules working in a wide spectrum of electronic devices, ranging from molecular wires, spin valves/switches, diodes, transistors, and sensors. More specifically, we have observed significant magnetoresistive effect in a spin-valve structure where the non-magnetic spacer sandwiched between two magnetic conducting materials is replaced by a self-assembled monolayer of organic molecules or a single molecule (like a carbon fullerene). The diode behavior in donor(D)-bridge(B)-acceptor(A) type of single molecules is then discussed and a unimolecular transistor is designed. Lastly, we have proposed and primarily tested the idea of using functionalized electrodes for rapid nanopore DNA sequencing. In these studies, the fundamental roles of molecules and molecule-electrode interfaces on quantum electron transport have been investigated based on first-principles calculations of the electronic structure. Both the intrinsic properties of molecules themselves and the detailed interfacial features are found to play critical roles in electron transport at the molecular scale. The flexibility and tailorability of the properties of molecules have opened great opportunity in a purpose-driven design of electronic devices from the bottom up. The results that we gained from this work have helped in understanding the underlying physics, developing the fundamental mechanism and providing guidance for future experimental efforts.
Resumo:
KIVA is a FORTRAN code developed by Los Alamos national lab to simulate complete engine cycle. KIVA is a flow solver code which is used to perform calculation of properties in a fluid flow field. It involves using various numerical schemes and methods to solve the Navier-Stokes equation. This project involves improving the accuracy of one such scheme by upgrading it to a higher order scheme. The numerical scheme to be modified is used in the critical final stage calculation called as rezoning phase. The primitive objective of this project is to implement a higher order numerical scheme, to validate and verify that the new scheme is better than the existing scheme. The latest version of the KIVA family (KIVA 4) is used for implementing the higher order scheme to support handling the unstructured mesh. The code is validated using the traditional shock tube problem and the results are verified to be more accurate than the existing schemes in reference with the analytical result. The convection test is performed to compare the computational accuracy on convective transfer; it is found that the new scheme has less numerical diffusion compared to the existing schemes. A four valve pentroof engine, an example case of KIVA package is used as application to ensure the stability of the scheme in practical application. The results are compared for the temperature profile. In spite of all the positive results, the numerical scheme implemented has a downside of consuming more CPU time for the computational analysis. The detailed comparison is provided. However, in an overview, the implementation of the higher order scheme in the latest code KIVA 4 is verified to be successful and it gives better results than the existing scheme which satisfies the objective of this project.
Resumo:
This report is a PhD dissertation proposal to study the in-cylinder temperature and heat flux distributions within a gasoline turbocharged direct injection (GTDI) engine. Recent regulations requiring automotive manufacturers to increase the fuel efficiency of their vehicles has led to great technological achievements in internal combustion engines. These achievements have increased the power density of gasoline engines dramatically in the last two decades. Engine technologies such as variable valve timing (VVT), direct injection (DI), and turbocharging have significantly improved engine power-to-weight and power-to-displacement ratios. A popular trend for increasing vehicle fuel economy in recent years has been to downsize the engine and add VVT, DI, and turbocharging technologies so that a lighter more efficient engine can replace a larger, heavier one. With the added power density, thermal management of the engine becomes a more important issue. Engine components are being pushed to their temperature limits. Therefore it has become increasingly important to have a greater understanding of the parameters that affect in-cylinder temperatures and heat transfer. The proposed research will analyze the effects of engine speed, load, relative air-fuel ratio (AFR), and exhaust gas recirculation (EGR) on both in-cylinder and global temperature and heat transfer distributions. Additionally, the effect of knocking combustion and fuel spray impingement will be investigated. The proposed research will be conducted on a 3.5 L six cylinder GTDI engine. The research engine will be instrumented with a large number of sensors to measure in-cylinder temperatures and pressures, as well as, the temperature, pressure, and flow rates of energy streams into and out of the engine. One of the goals of this research is to create a model that will predict the energy distribution to the crankshaft, exhaust, and cooling system based on normalized values for engine speed, load, AFR, and EGR. The results could be used to aid in the engine design phase for turbocharger and cooling system sizing. Additionally, the data collected can be used for validation of engine simulation models, since in-cylinder temperature and heat flux data is not readily available in the literature..
Resumo:
OBJECTIVES: To assess the effect of ileal bladder substitutes with preservation of the ileocecal valve and distal 25 cm of ileum on nephrolithiasis. METHODS: We reviewed a consecutive series of 518 patients (44 women and 474 men) with ileal orthotopic bladder substitution in whom 55 to 65 cm of ileum was resected but with preservation of the ileocecal valve and distal 25 cm of ileum, to determine prevalence of nephrolithiasis as well as bicarbonate, base excess, creatinine levels, and urinary pH at time of stone diagnosis and 2 years before it. RESULTS: Four male patients with a median age of 66 years (range, 50 to 70 years) developed nephrolithiasis after ileal bladder substitute, for a total of five calculi. The prevalence of nephrolithiasis in this retrospective cohort is thus 1% (5 of 518). They developed the calculi after a median follow-up of 8 years (range, 4 to 17 years). The four patients were diagnosed with calculi at 2.3, 3, 10, 10.3, and 14 years after bladder substitute. Two of the stones were uric acid calculi; the remaining three were calcium oxalate. None of our patients were acidotic or had elevated serum creatinines at time of stone formation. Urinary pH determined once in spontaneously voided urine at the time of stone diagnosis was pH 6.0 for the two uric acid calculi and pH 7.0 for the remaining calculi. CONCLUSIONS: The present study demonstrates a low prevalence of calculi in our cohort.