911 resultados para Transmission power systems


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Future power grids are envisioned to be serviced by heterogeneous arrangements of renewable energy sources. Due to their stochastic nature, energy storage distribution and management are pivotal in realizing microgrids serviced heavily by renewable energy assets. Identifying the required response characteristics to meet the operational requirements of a power grid are of great importance and must be illuminated in order to discern optimal hardware topologies. Hamiltonian Surface Shaping and Power Flow Control (HSSPFC) presents the tools to identify such characteristics. By using energy storage as actuation within the closed loop controller, the response requirements may be identified while providing a decoupled controller solution. A DC microgrid servicing a fixed RC load through source and bus level storage managed by HSSPFC was realized in hardware. A procedure was developed to calibrate the DC microgrid architecture of this work to the reduced order model used by the HSSPFC law. Storage requirements were examined through simulation and experimental testing. Bandwidth contributions between feed forward and PI components of the HSSPFC law are illuminated and suggest the need for well-known system losses to prevent the need for additional overhead in storage allocations. The following work outlines the steps taken in realizing a DC microgrid and presents design considerations for system calibration and storage requirements per the closed loop controls for future DC microgrids.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The recent development of the concept of microgrid (μGrid), associated to the emergent interest in microgeneration (μGen), has raised a number of challenges regarding the evaluation of the technical, economical and regulatory impacts of a high penetration of this kind of solutions in the power systems. In this paper, the topic of security of supply is addressed, aiming at evaluating the influence of μGen and μGrids in the medium- and long-term availability of generation to serve the forecasted load. A Monte-Carlo based methodology is used to evaluate this influence and to assess the capacity credit of those entities.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the scope of the discussions about microgeneration (and microgrids), the avoided electrical losses are often pointed out as an important value to be credited to those entities. Therefore, methods to assess the impact of microgeneration on losses must be developed in order to support the definition of a suitable regulatory framework for the economic integration of microgeneration on distribution networks. This paper presents an analytical method to quantify the value of avoided losses that microgeneration may produce on LV networks. Intervals of expected avoided losses are used to account for the variation of avoided losses due to the number, size and location of microgenerators, as well as for the kind of load distribution on LV networks.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The emergence of microgeneration has recently lead to the concept of microgrid, a network of LV consumers and producers able to export electric energy in some circumstances and also to work in an isolated way in emergency situations. Research on the organization of microgrids, control devices, functionalities and other technical aspects is presently being carried out, in order to establish a consistent technical framework to support the concept. The successful development of the microgrid concept implies the definition of a suitable regulation for its integration on distribution systems. In order to define such a regulation, the identification of costs and benefits that microgrids may bring is a crucial task. Actually, this is the basis for a discussion about the way global costs could be divided among the different agents that benefit from the development of microgrids. Among other aspects, the effect of microgrids on the reliability of the distribution network has been pointed out as an important advantage, due to the ability of isolated operation in emergency situations. This paper identifies the situations where the existence of a microgrid may reduce the interruption rate and duration and thus improve the reliability indices of the distribution network. The relevant expressions necessary to quantify the reliability are presented. An illustrative example is included, where the global influence of the microgrid in the reliability is commented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis studies the state-of-the-art of phasor measurement units (PMUs) as well as their metrological requirements stated in the IEEE C37.118.1 and C37.118.2 Standards for guaranteeing correct measurement performances. Communication systems among PMUs and their possible applicability in the field of power quality (PQ) assessment are also investigated. This preliminary study is followed by an analysis of the working principle of real-time (RT) simulators and the importance of hardware-in-the-loop (HIL) implementation, examining the possible case studies specific for PMUs, including compliance tests which are one of the most important parts. The core of the thesis is focused on the implementation of a PMU model in the IEEE 5-bus network in Simulink and in the validation of the results using OPAL RT-4510 as a real-time simulator. An initial check allows one to get an idea about the goodness of the results in Simulink, comparing the PMU data with respect to the load-flow steady-state information. In this part, accuracy indices are also calculated for both voltage and current synchrophasors. The following part consists in the implementation of the same code in OPAL-RT 4510 simulator, after which an initial analysis is carried out in a qualitative way in order to get a sense of the goodness of the outcomes. Finally, the confirmation of the results is based on an examination of the attained voltage and current synchrophasors and accuracy indices coming from Simulink models and from OPAL system, using a Matlab script. This work also proposes suggestions for an upcoming operation of PMUs in a more complex system as the Digital Twin (DT) in order to improve the performances of the already-existing protection devices of the distribution system operator (DSO) for a future enhancement of power systems reliability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Energy transition is the response of humankind to the concerning effects of fossil fuels depletion, climate change and energy insecurity, and calls for a deep penetration of renewable energy sources (RESs) in power systems and industrial processes. Despite the high potentials, low impacts and long-term availability, RESs present some limits which need to be overcome, such as the strong variability and difficult predictability, which result in scarce reliability and difficult applicability in steady-state processes. Some technological solutions relate to energy storage systems, equipment electrification and hybrid systems deployment, thus accomplishing distributed generation even in remote sites as offshore. However, all of these actions cannot disregard sustainability, which represents a founding principle for any project, bringing together economics, reliability and environmental protection. To entail sustainability in RESs-based innovative projects, previous knowledge and tools are often not tailored or miss the novel objectives. This research proposes three methodological approaches, bridging the gaps. The first contribute adapts literature-based indicators of inherent safety and energy efficiency to capture the specificities of novel process plants and hybrid systems. Minor case studies dealing with novel P2X processes exemplify the application of these novel indicators. The second method guides the conceptual design of hybrid systems for the valorisation of a RES in a site, by considering the sustainability performances of alternative design options. Its application is demonstrated through the comparison of two offshore sites where wave energy can be valorised. Finally, “OHRES”, a comprehensive tool for the sustainable optimisation of hybrid renewable energy systems is proposed. “OHRES” hinges on the exploitation of multiple RESs, by converting ex-post sustainability indicators into discrimination markers screening a large number of possible system configurations, according to the location features. Five case studies demonstrate “OHRES” versatility in the sustainable valorisation of multiple RESs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Distributed Generation, microgrid technologies, two-way communication systems, and demand response programs are issues that are being studied in recent years within the concept of smart grids. At some level of enough penetration, the Distributed Generators (DGs) can provide benefits for sub-transmission and transmission systems through the so-called ancillary services. This work is focused on the ancillary service of reactive power support provided by DGs, specifically Wind Turbine Generators (WTGs), with high level of impact on transmission systems. The main objective of this work is to propose an optimization methodology to price this service by determining the costs in which a DG incurs when it loses sales opportunity of active power, i.e, by determining the Loss of Opportunity Costs (LOC). LOC occur when more reactive power is required than available, and the active power generation has to be reduced in order to increase the reactive power capacity. In the optimization process, three objectives are considered: active power generation costs of DGs, voltage stability margin of the system, and losses in the lines of the network. Uncertainties of WTGs are reduced solving multi-objective optimal power flows in multiple probabilistic scenarios constructed by Monte Carlo simulations, and modeling the time series associated with the active power generation of each WTG via Fuzzy Logic and Markov Chains. The proposed methodology was tested using the IEEE 14 bus test system with two WTGs installed. © 2011 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Collision-induced power jitter is theoretically and numerically examined in dispersion-managed wavelength-division-multiplexed optical soliton transmission systems. The variational method is mainly used to develop a time efficient jitter calculation approach. The power jitter causes a serious problem for a singly periodic dispersion managed line having almost zero average dispersion, which can be reduced by applying doubly periodic dispersion management.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report the impact of longitudinal signal power profile on the transmission performance of coherently-detected 112 Gb/s m-ary polarization multiplexed quadrature amplitude modulation system after compensation of deterministic nonlinear fibre impairments. Performance improvements up to 0.6 dB (Q(eff)) are reported for a non-uniform transmission link power profile. Further investigation reveals that the evolution of the transmission performance with power profile management is fully consistent with the parametric amplification of the amplified spontaneous emission by the signal through four-wave mixing. In particular, for a non-dispersion managed system, a single-step increment of 4 dB in the amplifier gain, with respect to a uniform gain profile, at similar to 2/3(rd) of the total reach considerably improves the transmission performance for all the formats studied. In contrary a negative-step profile, emulating a failure (gain decrease or loss increase), significantly degrades the bit-error rate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report for the first time on the limitations in the operational power range of few-mode fiber based transmission systems, employing 28Gbaud quadrature phase shift keying transponders, over 1,600km. It is demonstrated that if an additional mode is used on a preexisting few-mode transmission link, and allowed to optimize its performance, it will have a significant impact on the pre-existing mode. In particular, we show that for low mode coupling strengths (weak coupling regime), the newly added variable power mode does not considerably impact the fixed power existing mode, with performance penalties less than 2dB (in Q-factor). On the other hand, as mode coupling strength is increased (strong coupling regime), the individual launch power optimization significantly degrades the system performance, with penalties up to ∼6dB. Our results further suggest that mutual power optimization, of both fixed power and variable power modes, reduces power allocation related penalties to less than 3dB, for any given coupling strength, for both high and low differential mode delays. © 2013 Optical Society of America.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report the impact of longitudinal signal power profile on the transmission performance of coherently-detected 112 Gb/s m-ary polarization multiplexed quadrature amplitude modulation system after compensation of deterministic nonlinear fibre impairments. Performance improvements up to 0.6 dB (Q(eff)) are reported for a non-uniform transmission link power profile. Further investigation reveals that the evolution of the transmission performance with power profile management is fully consistent with the parametric amplification of the amplified spontaneous emission by the signal through four-wave mixing. In particular, for a non-dispersion managed system, a single-step increment of 4 dB in the amplifier gain, with respect to a uniform gain profile, at similar to 2/3(rd) of the total reach considerably improves the transmission performance for all the formats studied. In contrary a negative-step profile, emulating a failure (gain decrease or loss increase), significantly degrades the bit-error rate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The first part of the thesis has been devoted to the transmission planning with high penetration of renewable energy sources. Both stationary and transportable battery energy storage (BES, BEST) systems have been considered in the planning model, so to obtain the optimal set of BES, BEST and transmission lines that minimizes the total cost in a power network. First, a coordinated expansion planning model with fixed transportation cost for BEST devices has been presented; then, the model has been extended to a planning formulation with a distance-dependent transportation cost for the BEST units, and its tractability has been proved through a case study based on a 190-bus test system. The second part of this thesis is then devoted to the analysis of planning and management of renewable energy communities (RECs). Initially, the planning of photovoltaic and BES systems in a REC with an incentive-based remuneration scheme according to the Italian regulatory framework has been analysed, and two planning models, according to a single-stage, or a multi-stage approach, have been proposed in order to provide the optimal set of BES and PV systems allowing to achieve the minimum energy procurement cost in a given REC. Further, the second part of this thesis is devoted to the study of the day-ahead scheduling of resources in renewable energy communities, by considering two types of REC. The first one, which we will refer to as “cooperative community”, allows direct energy transactions between members of the REC; the second type of REC considered, which we shall refer to as “incentive-based”, does not allow direct transactions between members but includes economic revenues for the community shared energy, according to the Italian regulation framework. Moreover, dispatchable renewable energy generation has been considered by including producers equipped with biogas power plants in the community.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This paper presents a new approach to the transmission loss allocation problem in a deregulated system. This approach belongs to the set of incremental methods. It treats all the constraints of the network, i.e. control, state and functional constraints. The approach is based on the perturbation of optimum theorem. From a given optimal operating point obtained by the optimal power flow the loads are perturbed and a new optimal operating point that satisfies the constraints is determined by the sensibility analysis. This solution is used to obtain the allocation coefficients of the losses for the generators and loads of the network. Numerical results show the proposed approach in comparison to other methods obtained with well-known transmission networks, IEEE 14-bus. Other test emphasizes the importance of considering the operational constraints of the network. And finally the approach is applied to an actual Brazilian equivalent network composed of 787 buses, and it is compared with the technique used nowadays by the Brazilian Control Center. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this paper, an extended impedance-based fault-location formulation for generalized distribution systems is presented. The majority of distribution feeders are characterized by having several laterals, nonsymmetrical lines, highly unbalanced operation, and time-varying loads. These characteristics compromise traditional fault-location methods performance. The proposed method uses only local voltages and currents as input data. The current load profile is obtained through these measurements. The formulation considers load variation effects and different fault types. Results are obtained from numerical simulations by using a real distribution system from the Electrical Energy Distribution State Company of Rio Grande do Sul (CEEE-D), Southern Brazil. Comparative results show the technique robustness with respect to fault type and traditional fault-location problems, such as fault distance, resistance, inception angle, and load variation. The formulation was implemented as embedded software and is currently used at CEEE-D`s distribution operation center.