902 resultados para Transcranial magnetic stimulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study sought to establish an accurate and reproducible T(2)-mapping cardiac magnetic resonance (CMR) methodology at 3 T and to evaluate it in healthy volunteers and patients with myocardial infarct. BACKGROUND: Myocardial edema affects the T(2) relaxation time on CMR. Therefore, T(2)-mapping has been established to characterize edema at 1.5 T. A 3 T implementation designed for longitudinal studies and aimed at guiding and monitoring therapy remains to be implemented, thoroughly characterized, and evaluated in vivo. METHODS: A free-breathing navigator-gated radial CMR pulse sequence with an adiabatic T(2) preparation module and an empirical fitting equation for T(2) quantification was optimized using numerical simulations and was validated at 3 T in a phantom study. Its reproducibility for myocardial T(2) quantification was then ascertained in healthy volunteers and improved using an external reference phantom with known T(2). In a small cohort of patients with established myocardial infarction, the local T(2) value and extent of the edematous region were determined and compared with conventional T(2)-weighted CMR and x-ray coronary angiography, where available. RESULTS: The numerical simulations and phantom study demonstrated that the empirical fitting equation is significantly more accurate for T(2) quantification than that for the more conventional exponential decay. The volunteer study consistently demonstrated a reproducibility error as low as 2 ± 1% using the external reference phantom and an average myocardial T(2) of 38.5 ± 4.5 ms. Intraobserver and interobserver variability in the volunteers were -0.04 ± 0.89 ms (p = 0.86) and -0.23 ± 0.91 ms (p = 0.87), respectively. In the infarction patients, the T(2) in edema was 62.4 ± 9.2 ms and was consistent with the x-ray angiographic findings. Simultaneously, the extent of the edematous region by T(2)-mapping correlated well with that from the T(2)-weighted images (r = 0.91). CONCLUSIONS: The new, well-characterized 3 T methodology enables robust and accurate cardiac T(2)-mapping at 3 T with high spatial resolution, while the addition of a reference phantom improves reproducibility. This technique may be well suited for longitudinal studies in patients with suspected or established heart disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our objective was to establish the age-related 3D size of maxillary, sphenoid, and frontal sinuses. A total of 179 magnetic resonance imaging (MRI) of children under 17 years (76 females, 103 males) were included and sinuses were measured in the three axes. Maxillary sinuses measured at birth (mean+/-standard deviation) 7.3+/-2.7 mm length (or antero-posterior)/4.0+/-0.9 mm height (or cranio-caudal)/2.7+/-0.8 mm width (or transverse). At 16 years old, maxillary sinus measured 38.8+/-3.5 mm/36.3+/-6.2 mm/27.5+/-4.2 mm. Sphenoid sinus pneumatization starts in the third year of life after conversion from red to fatty marrow with mean values of 5.8+/-1.4 mm/8.0+/-2.3 mm/5.8+/-1.0 mm. Pneumatization progresses gradually to reach at 16 years 23.0+/-4.5 mm/22.6+/-5.8 mm/12.8+/-3.1 mm. Frontal sinuses present a wide variation in size and most of the time are not valuable with routine head MRI techniques. They are not aerated before the age of 6 years. Frontal sinuses dimensions at 16 years were 12.8+/-5.0 mm/21.9+/-8.4 mm/24.5+/-13.3 mm. A sinus volume index (SVI) of maxillary and sphenoid sinus was computed using a simplified ellipsoid volume formula, and a table with SVI according to age with percentile variations is proposed for easy clinical application. Percentile curves of maxillary and sphenoid sinuses are presented to provide a basis for objective determination of sinus size and volume during development. These data are applicable to other techniques such as conventional X-ray and CT scan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding how nanoparticles may affect immune responses is an essential prerequisite to developing novel clinical applications. To investigate nanoparticle-dependent outcomes on immune responses, dendritic cells (DCs) were treated with model biomedical poly(vinylalcohol)-coated super-paramagnetic iron oxide nanoparticles (PVA-SPIONs). PVA-SPIONs uptake by human monocyte-derived DCs (MDDCs) was analyzed by flow cytometry (FACS) and advanced imaging techniques. Viability, activation, function, and stimulatory capacity of MDDCs were assessed by FACS and an in vitro CD4(+) T cell assay. PVA-SPION uptake was dose-dependent, decreased by lipopolysaccharide (LPS)-induced MDDC maturation at higher particle concentrations, and was inhibited by cytochalasin D pre-treatment. PVA-SPIONs did not alter surface marker expression (CD80, CD83, CD86, myeloid/plasmacytoid DC markers) or antigen-uptake, but decreased the capacity of MDDCs to process antigen, stimulate CD4(+) T cells, and induce cytokines. The decreased antigen processing and CD4(+) T cell stimulation capability of MDDCs following PVA-SPION treatment suggests that MDDCs may revert to a more functionally immature state following particle exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comment on N Engl J Med. 2010 Jun 3;362(22):2077-91 author reply 988.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary magnetic resonance imaging is a powerful non-invasive technique for the combined assessment of coronary artery anatomy and function. In the present review article, challenges in coronary artery imaging are discussed and results obtained in both healthy volunteers and patients with cardiovascular disease are presented. This includes a short overview of coronary artery vessel lumen and wall imaging, contrast agents, permeability of the coronary vessel wall, high-field imaging and imaging of endothelial function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Subthalamic nucleus deep brain stimulation (STN-DBS) is a recognized treatment for advanced and severe forms of Parkinson's Disease. The procedure improves motor signs and often allows a reduction of the medication. The impact of the procedure on cognitive and neuropsychiatric signs of the disease is more debated and there is an international consensus for the need of a multidisciplinary evaluation of patients undergoing such programs, including a neuropsychiatric assessment. We present a review of the literature as well as the experience at our centre focused on the short and long term outcome on mood following STN-DBS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the last two decades, ultrasound (US) has been considered a surrogate for the gold standard in the evaluation of liver fibrosis in schistosomiasis. The use of magnetic resonance imaging (MRI) is not yet standardised for diagnosing and grading liver schistosomal fibrosis. The aim of this paper was to analyse MRI using an adaptation of World Health Organization (WHO) patterns for US assessment of schistosomiasis-related morbidity. US and MRI were independently performed in 60 patients (42.1 ± 13.4 years old), including 37 men and 23 women with schistosomiasis. Liver involvement appraised by US and MRI was classified according to the WHO protocol from patterns A-F. Agreement between image methods was evaluated by kappa index (k). The correlation between US and MRI was poor using WHO patterns [k = 0.14; confidence interval (CI) 0.02; 0.26]. Even after grouping image patterns as "A-D", "Dc-E" and "Ec-F", the correlation between US and MRI remained weak (k = 0.39; CI 0.21; 0.58). The magnetic resonance adaptation used in our study did not confirm US classification of WHO patterns for liver fibrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Levels of circulating cardiac troponin I (cTnI) or T are correlated to extent of myocardial destruction after an acute myocardial infarction. Few studies analyzing this relation have employed a second-generation cTnI assay or cardiac magnetic resonance (CMR) as the imaging end point. In this post hoc study of the Efficacy of FX06 in the Prevention of Mycoardial Reperfusion Injury (F.I.R.E.) trial, we aimed at determining the correlation between single-point cTnI measurements and CMR-estimated infarct size at 5 to 7 days and 4 months after a first-time ST-elevation myocardial infarction (STEMI) and investigating whether cTnI might provide independent prognostic information regarding infarct size at 4 months even taking into account early infarct size. Two hundred twenty-seven patients with a first-time STEMI were included in F.I.R.E. All patients received primary percutaneous coronary intervention within 6 hours from onset of symptoms. cTnI was measured at 24 and 48 hours after admission. CMR was conducted within 1 week of the index event (5 to 7 days) and at 4 months. Pearson correlations (r) for infarct size and cTnI at 24 hours were r = 0.66 (5 days) and r = 0.63 (4 months) and those for cTnI at 48 hours were r = 0.67 (5 days) and r = 0.65 (4 months). In a multiple regression analysis for predicting infarct size at 4 months (n = 141), cTnI and infarct location retained an independent prognostic role even taking into account early infarct size. In conclusion, a single-point cTnI measurement taken early after a first-time STEMI is a useful marker for infarct size and might also supplement early CMR evaluation in prediction of infarct size at 4 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif : Etudier les résultats cliniques du traitement de patients atteints pai- une épilepsie mésiale du lobe temporal (MTLE) réfractaire, par stimulation cérébrale profonde (DBS) de l'hippocampe, en fonction de l'emplacement de l'électrode. Méthodes : Huit patients atteints de MTLE implantés dans l'hippocampe et stimulés par DBS à haute fréquence ont été inclus dans cette étude. Cinq ont subi des enregistrements invasifs avec des électrodes profondes dans le but d'estimer la localisation du foyer ictal avant de procéder à une DBS chronique. La position des contacts actifs de l'électrode a été mesurée en utilisant une imagerie post-opératoire. Les distances par rapport au foyer ictal ont été calculées, et les structures hippocampiques influencées par la stimulation ont été identifiées au moyen d'un atlas neuro-anatomique. Ces deux paramètres ont été corrélés avec la réduction de la fréquence d'apparition des crises. Résultats : Les distances entre la localisation estimée des contacts actifs de l'électrode et le foyer ictal étaient respectivement 11.0 +/- 4.3 ou 9.1 +/- 2.3 mm pour les patients présentant une réduction de > 50% ou < 50% de la fréquence des crises. Chez les patients (N = 6) montrant une réduction de > 50% de la fréquence des crises, 100% avaient des contacts actifs situés à < 3 mm du subiculum (p < 0,05). Les 2 patients ne répondant pas au traitement étaient stimulés par des contacts situés à > 3mm du subiculum. Conclusion : La diminution de l'activité épileptogène induite par DBS sur l'hippocampe dans les cas de MTLE réfractaires : 1) ne semble pas directement liée à la proximité des contacts actifs de l'électrode au foyer ictal déterminé par les enregistrements invasifs ; 2) pourrait être obtenue par une neuro-modulation du subiculum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetic analysis of fission yeast suggests a role for the spHop2-Mnd1 proteins in the Rad51 and Dmc1-dependent meiotic recombination pathways. In order to gain biochemical insights into this process, we purified Schizosaccharomyces pombe Hop2-Mnd1 to homogeneity. spHop2 and spMnd1 interact by co-immunoprecipitation and two-hybrid analysis. Electron microscopy reveals that S. pombe Hop2-Mnd1 binds single-strand DNA ends of 3'-tailed DNA. Interestingly, spHop2-Mnd1 promotes the renaturation of complementary single-strand DNA and catalyses strand exchange reactions with short oligonucleotides. Importantly, we show that spHop2-Mnd1 stimulates spDmc1-dependent strand exchange and strand invasion. Ca(2+) alleviate the requirement for the order of addition of the proteins on DNA. We also demonstrate that while spHop2-Mnd1 affects spDmc1 specifically, mHop2 or mHop2-Mnd1 stimulates both the hRad51 and hDmc1 recombinases in strand exchange assays. Thus, our results suggest a crucial role for S. pombe and mouse Hop2-Mnd1 in homologous pairing and strand exchange and reveal evolutionary divergence in their specificity for the Dmc1 and Rad51 recombinases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to SNR constraints, current "bright-blood" 3D coronary MRA approaches still suffer from limited spatial resolution when compared to conventional x-ray coronary angiography. Recent 2D fast spin-echo black-blood techniques maximize signal for coronary MRA at no loss in image spatial resolution. This suggests that the extension of black-blood coronary MRA with a 3D imaging technique would allow for a further signal increase, which may be traded for an improved spatial resolution. Therefore, a dual-inversion 3D fast spin-echo imaging sequence and real-time navigator technology were combined for high-resolution free-breathing black-blood coronary MRA. In-plane image resolution below 400 microm was obtained. Magn Reson Med 45:206-211, 2001.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: We tested the hypothesis that twitch potentiation would be greater following conventional (CONV) neuromuscular electrical stimulation (50-µs pulse width and 25-Hz frequency) compared with wide-pulse high-frequency (WPHF) neuromuscular electrical stimulation (1-ms, 100-Hz) and voluntary (VOL) contractions, because of specificities in motor unit recruitment (random in CONV vs. random and orderly in WPHF vs. orderly in VOL). METHODS: A single twitch was evoked by means of tibial nerve stimulation before and 2 s after CONV, WPHF, and VOL conditioning contractions of the plantar flexors (intensity: 10% maximal voluntary contraction; duration: 10 s) in 13 young healthy subjects. RESULTS: Peak twitch increased (P<0.05) after CONV (+4.5±4.0%) and WPHF (+3.3±5.9%), with no difference between the 2 modalities, whereas no changes were observed after VOL (+0.8±2.6%). CONCLUSIONS: Our results demonstrate that presumed differences in motor unit recruitment between WPHF and CONV do not seem to influence twitch potentiation results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME Les améliorations méthodologiques des dernières décennies ont permis une meilleure compréhension de la motilité gastro-intestinale. Il manque toutefois une méthode qui permette de suivre la progression du chyme le long du tube gastro-intestinal. Pour permettre l'étude de la motilité de tout le tractus digestif humain, une nouvelle technique, peu invasive, a été élaborée au Département de Physiologie, en collaboration avec l'EPFL. Appelée "Magnet Tracking", la technique est basée sur la détection du champ magnétique généré par des matériaux ferromagnétiques avalés. A cet usage, une pilule magnétique, une matrice de capteurs et un logiciel ont été développés. L'objet de ce travail est de démontrer la faisabilité d'un examen de la motilité gastro-intestinale chez l'Homme par cette méthode. L'aimant est un cylindre (ø 6x7 mm, 0.2 cm3) protégé par une gaine de silicone. Le système de mesure est constitué d'une matrice de 4x4 capteurs et d'un ordinateur portable. Les capteurs fonctionnent sur l'effet Hall. Grâce à l'interface informatique, l'évolution de la position de l'aimant est suivie en temps réel à travers tout le tractus digestif. Sa position est exprimée en fonction du temps ou reproduite en 3-D sous forme d'une trajectoire. Différents programmes ont été crées pour analyser la dynamique des mouvements de l'aimant et caractériser la motilité digestive. Dix jeunes volontaires en bonne santé ont participé à l'étude. L'aimant a été avalé après une nuit de jeûne et son séjour intra digestif suivi pendant 2 jours consécutifs. Le temps moyen de mesure était de 34 heures. Chaque sujet a été examiné une fois sauf un qui a répété sept fois l'expérience. Les sujets restaient en décubitus dorsal, tranquilles et pouvaient interrompre la mesure s'ils le désiraient. Ils sont restés à jeûne le premier jour. L'évacuation de l'aimant a été contrôlée chez tous les sujets. Tous les sujets ont bien supporté l'examen. Le marqueur a pu être détecté de l'oesophage au rectum. La trajectoire ainsi constituée représente une conformation de l'anatomie digestive : une bonne superposition de celle-ci à l'anatomie est obtenue à partir des images de radiologie conventionnelle (CT-scan, lavement à la gastrografine). Les mouvements de l'aimant ont été caractérisés selon leur périodicité, leur amplitude ou leur vitesse pour chaque segment du tractus digestif. Ces informations physiologiques sont bien corrélées à celles obtenues par des méthodes établies d'étude de la motilité gastro-intestinale. Ce travail démontre la faisabilité d'un examen de la motilité gastro-intestinal chez l'Homme par la méthode de Magnet Tracking. La technique fournit les données anatomiques et permet d'analyser en temps réel la dynamique des mouvements du tube digestif. Cette méthode peu invasive ouvre d'intéressantes perspectives pour l'étude de motilité dans des conditions physiologiques et pathologiques. Des expériences visant à valider cette approche en tant que méthode clinique sont en voie de réalisation dans plusieurs centres en Suisse et à l'étranger. SUMMARY Methodological improvements realised over the last decades have permitted a better understanding of gastrointestinal motility. Nevertheless, a method allowing a continuous following of lumina' contents is still lacking. In order to study the human digestive tract motility, a new minimally invasive technique was developed at the Department of Physiology in collaboration with Swiss Federal Institute of Technology. The method is based on the detection of magnetic field generated by swallowed ferromagnetic materials. The aim of our work was to demonstrate the feasibility of this new approach to study the human gastrointestinal motility. The magnet used was a cylinder (ø6x7mm, 0.2 cm3) coated with silicon. The magnet tracking system consisted of a 4x4 matrix of sensors based on the Hall effect Signals from the sensors were digitised and sent to a laptop computer for processing and storage. Specific software was conceived to analyse in real time the progression of the magnet through the gastrointestinal tube. Ten young and healthy volunteers were enrolled in the study. After a fasting period of 12 hours, they swallowed the magnet. The pill was then tracked for two consecutive days for 34 hours on average. Each subject was studied once except one who was studied seven times. Every subject laid on his back for the entire experiment but could interrupt it at anytime. Evacuation of the magnet was controlled in all subjects. The examination was well tolerated. The pill could be followed from the esophagus to the rectum. The trajectory of the magnet represented a "mould" of the anatomy of the digestive tube: a good superimposition with radiological anatomy (gastrografin contrast and CT) was obtained. Movements of the magnet were characterized by periodicity, velocity, and amplitude of displacements for every segment of the digestive tract. The physiological information corresponded well to data from current methods of studying gastrointestinal motility. This work demonstrates the feasibility of the new approach in studies of human gastrointestinal motility. The technique allows to correlate in real time the dynamics of digestive movements with the anatomical data. This minimally invasive method is ready for studies of human gastrointestinal motility under physiological as well as pathological conditions. Studies aiming at validation of this new approach as a clinically relevant tool are being realised in several centres in Switzerland and abroad. Abstract: A new minimally invasive technique allowing for anatomical mapping and motility studies along the entire human digestive system is presented. The technique is based on continuous tracking of a small magnet progressing through the digestive tract. The coordinates of the magnet are calculated from signals recorded by 16 magnetic field sensors located over the abdomen. The magnet position, orientation and trajectory are displayed in real time. Ten young healthy volunteers were followed during 34 h. The technique was well tolerated and no complication was encountered, The information obtained was 3-D con-figuration of the digestive tract and dynamics of the magnet displacement (velocity, transit time, length estimation, rhythms). In the same individual, repea-ted examination gave very reproducible results. The anatomical and physiological information obtained corresponded well to data from current methods and imaging. This simple, minimally invasive technique permits examination of the entire digestive tract and is suitable for both research and clinical studies. In combination with other methods, it may represent a useful tool for studies of Cl motility with respect to normal and pathological conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The simultaneous recording of scalp electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) can provide unique insights into the dynamics of human brain function, and the increased functional sensitivity offered by ultra-high field fMRI opens exciting perspectives for the future of this multimodal approach. However, simultaneous recordings are susceptible to various types of artifacts, many of which scale with magnetic field strength and can seriously compromise both EEG and fMRI data quality in recordings above 3T. The aim of the present study was to implement and characterize an optimized setup for simultaneous EEG-fMRI in humans at 7T. The effects of EEG cable length and geometry for signal transmission between the cap and amplifiers were assessed in a phantom model, with specific attention to noise contributions from the MR scanner coldheads. Cable shortening (down to 12cm from cap to amplifiers) and bundling effectively reduced environment noise by up to 84% in average power and 91% in inter-channel power variability. Subject safety was assessed and confirmed via numerical simulations of RF power distribution and temperature measurements on a phantom model, building on the limited existing literature at ultra-high field. MRI data degradation effects due to the EEG system were characterized via B0 and B1(+) field mapping on a human volunteer, demonstrating important, although not prohibitive, B1 disruption effects. With the optimized setup, simultaneous EEG-fMRI acquisitions were performed on 5 healthy volunteers undergoing two visual paradigms: an eyes-open/eyes-closed task, and a visual evoked potential (VEP) paradigm using reversing-checkerboard stimulation. EEG data exhibited clear occipital alpha modulation and average VEPs, respectively, with concomitant BOLD signal changes. On a single-trial level, alpha power variations could be observed with relative confidence on all trials; VEP detection was more limited, although statistically significant responses could be detected in more than 50% of trials for every subject. Overall, we conclude that the proposed setup is well suited for simultaneous EEG-fMRI at 7T.