946 resultados para Torque (Ortodontia)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study of consumption rate and gaseous pollutant emission from engine tests simulating real work conditions, using spark point manually controlled and exhaust gas recirculation (EGR) in diverse proportion levels. The objective of this work is to re-examine the potential of the EGR conception, a well-known method of combustion control, employed together electronic fuel injection and three-way catalytic converter closed-loop control at a spark ignition engine, verifying the performance characteristics and technical availability of this conception to improve pollution control, fuel economy at low torque drive condition and to improve the engine exhaust components useful life. The pollutant emissions and consumption levels under operational conditions simulations were analysed and compared with the expected by concerning theory and real tests performed by EGR equipped engines by factory. Copyright © 2006 Society of Automotive Engineers, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paperwork presents a Pulse Width Modulation (PWM) speed controller for an electric mini-baja-type car. A battery-fed 1-kW three-phase induction motor provides the electric vehicle traction. The open-loop speed control is implemented with an equal voltage/frequency ratio, in order to maintain a constant amount of torque on all velocities. The PWM is implemented by a low-cost 8-bit microcontroller provided with optimized ROM charts for distinct speed value implementations, synchronized transition between different charts and reduced odd harmonics generation. This technique was implemented using a single passenger mini-baja vehicle, and the essays have shown that its application resulted on reduced current consumption, besides eliminating mechanical parts. Copyright © 2007 by ABCM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: the purpose of this prospective study was to cephalometrically analyze the dentoalveolar and soft tissue changes after the orthodontic treatment followed by the extraction of four premolars. Material and methods: the sample was comprised by 30 Class II division 1 patients with mean initial age of 12 years and 4 months. Two lateral cephalograms were obtained from each patient at the beginning and at the end of the treatment. The variables analyzed were the nasalabial changes and upper and lower incisors changes in relation to a vertical and horizontal x and y reference lines. Results: upper and lower incisors retraction was 3.4 and 1.8mm, respectively. The SNA angle was decresead by 1.7 degrees followed by a retraction of point A mainly due to the upper incisor retraction. There was a significant decrease of the Wits and ANB variables. There was an increase in the lower anterior facial height. Upper incisor retraction was followed by an increase in the nasolabial angle (ratio 1:2.8 degrees). However, a wide range of individual variability was found. Conclusions: the present study did not support the simple expectation that treatment with extractions of four premolars will result in a dished in face. It appeared that facial changes were more related to a normal facial growth, the amount of incisor retraction and the anchorage control during the upper and lower incisor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: the current study aims at following up radiographically the evolution of the midpalatal suture during the expansion procedure since the opening of the suture until bone formation. Methods: the sample comprised 38 patients in the mixed dentition stage submitted to the rapid palatal expansion protocol of the Hospital for Rehabilitation of Craniofacial Anomalies. Results: it was observed an individual variation on the period of bone ossification of the midpalatal suture, which justifies the radiographic follow-up as determinant for the appliance removal. Due to long-term post-treatment stability, the expander should be removed after the new suture is completely formed. Conclusions: the findings show that it is necessary more than three months for the complete reorganization of the midpalatal suture during the passive phase of the rapid palatal expansion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The large use of plastics in the world generates a large amount of waste which persists around 200 years in the environment. To minimize this effect is important to search some new polymer materials: the blends of biodegradable polymers with synthetic polymers. It is a large area that needs an Intensive research to investigate the blends properties and its behavior face to the different treatments to aim at the blodegradation. The blends used In this work are: some blodegradable polymers such as: poly(hydroxybutyrate) (PHB) and poly(s-polycaprolactone) (PCL) with a synthetic polymer, polypropylene (PP), in lower concentration. These blends were prepared using an internal mixer (Torque Rheometer), and pressed. These films were submitted to fungus biotreatment. The films analyses will be carried out by Fourier Transform Infrared (FTIR), UV-Vis absorption (UV-Vis), Scanning Electronic Microscopy (SEM), DSC and TGA. © 2008 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Orthodontics has always used lateral cephalometric radiographs (LC) as the main examination in the orthodontic diagnosis and treatment plan. The determination of incisor position is part of most cephalometric analysis, including Tweed analysis. However, all radiographic images have limitations, since it is a bidimensional image of a tridimensional structure and overlapping of bone and dental structures often occurs. Computed tomography (CT) allows a trustworthy diagnostic, mainly for its tridimensional images possibility. In this situation it seems reasonable to question the classic cephalometric analysis, creating factors of comparison with computed tomography data. Aim: For this, it was considered the evaluation of the angle between the long axis of the inferior incisor and the mandibular plane (IMPA) in the lateral cephalograph and in the computed tomography. Methods: Nineteen patients, selected for orthodontic treatment, had constituted the sample of this study, 12 female and 7 male, with ages between 16 years and 4 months and 28 years and 2 months. After the collection of data made by two examiners, statistical analyses for the attainment of the errors intra and inter-examiners had been made, using level of significance of 5%. Results and Conclusion: It was concluded that IMPA can be measured in the lateral cephalometric radiographs with trustworthiness, even that its values were smaller when compared with the computed tomography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to investigate if chronic eccentric strength training (ST) affects heart rate (HR) and heart rate variability (HRV) during sub-maximal isometric voluntary contractions (SIVC). The training group (TG) (9 men, 62 ± 2) was submitted to ST (12 weeks, 2 days/week, 2 - 4 sets of 8-12 repetitions at 75-80% peak torque (PT). The control group (CG) (8 men, 64 ± 4) did not perform ST. The HR and the HRV (RMSSD index) were evaluated during SIVC of the knee extension (15, 30 and 40% of PT). ST increased the eccentric torque only in TG, but did not change the isometric PT and the duration of SIVC. During SIVC, the HR response pattern and the RMSSD index were similar for both groups in pre- and post-training evaluations. Although ST increased the eccentric torque in the TG, it did not generate changes in HR or HRV. © Springer-Verlag 2008.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to compare the torque, torque ratio (Hamstrings:Quadriceps - H:Q), electromyographic (EMG) activity and EMG ratio (knee flexors:knee extensors EMG) in soccer players (SG, N=10) and active subjects (AG, N=10). Subjects performed three maximal voluntary isometric knee extensions and flexions at 45° and 90° to determine the peak torque and EMG activity. Torque and EMG activity of the knee flexor (biceps femoris [BF] and semitendinosus [ST]) were divided by the torque and EMG activity of the knee extensor (vastuls lateralis [VL] and rectus femoris [RF]) to calculate torque ratios (H:Q) and EMG ratios (BF:VL, BF:RF, ST:VL, ST:RF). The flexion torque was significantly higher for SG (p<0.05) in 45° and 90°. EMG activity for SG was significantly higher in agonist contractions for VL, RF and ST, and significantly lower in antagonist contractions for RF and ST when compared to AG Torque and EMG ratios were similar between groups and there were good correlations between torque ratio and BF:VL ratio (r=0.71, p=0.02) and BF:RF ratio (r=0.81, p=0.004) at 45. The EMG results could overestimate the joint balance calculated using torque ratios. Differences in recruitment pattern between soccer players and non-athletes can be related to the training routines and the EMG ratios presents applicable in trained populations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: The aim of this study was to evaluate the periodontal ligament changes after induced dental movement of the upper incisor in diabetic rats. Methods: Twenty Wistar rats (Rattus norvegicus) with 105 days of age were used. The rats were divided in four groups: C - normoglicemic animals not submitted to dental movement; CAO - normoglicemic animals submitted to dental movement; D - diabetic animals not submitted the dental movement; DAO - diabetic animals submitted to dental movement. The animals had remained with dental movement devices during 5 days. The number of sanguine vessels and the thickness of the periodontal ligament were evaluated at cervical, medium and apical histological cut regions. Results and Conclusion: At tension side, the dental movement in the animals of group CAO resulted in a thicker periodontal ligament (17.64% apical, 39.28% medium, 51.35% cervical) when compared to C group (p < 0.05 for medium and cervical area). Group DAO exhibited an increase of periodontal ligament thickness of 50.55% (apical), 48.14% (average) and 50% (cervical) when compared to group D (p < 0.05). The periodontal ligament sanguine vessels number did not differed significantly for all groups (p < 0.05). At tension side, bone reabsorption lacunae were observed in CAO, D and DAO groups. The pressure side was not examined in this study phase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The snoring is produced by the vibration of the soft palatum and/or other oropharyngeal tissues, during the air passage, in the breathing function. OSAHS is defined as the closing of 30%, at least, of the nasal/ buccal airway for 10 seconds or more, in spite of existing inspiratory effort, accompanied by oxyhemoglobin de- saturation of 4% or more. Objectives: To evaluate the available scientific evidence about the use of mandibular advancement intraoral appliances in the treatment of the snoring and/or OSAHS. Methodology: Electronic search strategy using predefined key-words and criteria was realized including studies published until October of 2008. It was also used the qualitative evaluation of the articles methodology. Results: Although a significant number of articles has studied this subject, only 7 articles showed methodological quality to be included in this systematic review. Conclusions: The intraoral appliances are widely prescribed for the treatment of snoring and OSAHS as primary therapy and as an alternative to patients who are unable to tolerate the positive airway pressure therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Professional evaluations and lay person evaluations as well do not show a clear relationship between hard tissue and soft tissue profiles in orthodontic patients. However, there are concrete evidences that the orthodontist can change the facial profile of the patients. aim: This research project aimed to measure the contribution of the bone structure of the maxilla and the upper incisors inclination to the upper lip profile. Methods: A sample of 147 adult patients, 58 male and 89 female, aged from 15 to 49 years, the most of them Caucasians, was retrospectively selected from the private practice of one of the authors. It was assumed that the esthetic facial profile depends of the hard tissues that support it besides its own features as thickness, strength and composition. The present research model was not set to control the intrinsic features of the soft tissue. To compose the Ricketts and Burstone esthetic lines, the main cephalometric variables were SNA and U1PP, when concomitantly considered. Results: The regression coefficients, although statistically significant, did not contributed expressively to explain the regard variables, the pre-defined esthetic lines. Furthermore, the results suggested a negative correlation between the maxillary position (SNA) and the anteroposterior inclination of the upper incisors (U1PP), possibly due to the compensatory action of the lips and the tongue. Conclusion: The results did not presented conclusive scientific evidences about the contribution of the hard tissues for the soft tissue facial profiles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: Alterations in implant surfaces can affect periimplant bone formation and shorten the healing time. The goal of the present study was a comparative scanning electron microscopy (SEM)/energy dispersive spectrometry (EDS) and biomechanical evaluation of implants subjected to different surface treatments. Materials and Methods: Four implant surfaces were analyzed in the present study: machined commercial implants (TU); porous-surfaced commercial implants blasted with Al2O3 microspheres and acid-etched (TJA); laser beam-irradiated experimental implants (Laser) and laser beam-irradiated experimental implants with hydroxyapatite coating (HA). One sample for each surface underwent pre-surgery SEM/EDS analysis. Thirty-two implants (8 for each surface treatment) were then inserted into the tibia of 4 rabbits. After 8 weeks, the animals were euthanized and the implants retrieved by reverse torque and processed for post-surgery SEM/EDS analysis. Results: HA implants presented higher removal torque values when compared to Laser, TJA and TU groups. Post-surgery SEM micrographs clearly showed bone formation on all the examined surfaces; however, in the TU group bone covered only some areas of the implant surface, while in TJA, Laser and HA groups the entire implant surfaces were overlaid by newly formed bone. EDS analysis supported the results obtained by SEM and removal torque, showing that concentration of Ca and P increased from TU to TJA, Laser and HA implants. Conclusions: Implants with surfaces modified by laser beam with or without apatite coating showed more promising results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate, using a biomechanical test, the force needed to remove implants with surface modification by laser (Nd:YAG) in comparison with implants with machined surfaces. Twenty-four rabbits received one implant with each surface treatment in the tibia, machined surface (MS) and laser-modified surface (LMS). After 4, 8 and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition and roughness. The average removal torque in each period was 23.28, 24.0 and 33.85 Ncm for MS, and 33.0, 39.87 and 54.57 Ncm for LMS, respectively. The difference between the surfaces in all periods of evaluation was statistically significant (p < 0.05). Surface characterization showed that a deep and regular topography was provided by the laser conditioning, with a great quantity of oxygen ions when compared to the MS. The surface micro-topography analysis showed a statistical difference (p < 0.01) between the roughness of the LMS (R a = 1.38 ± 0.23 μm) when compared to that of the MS (R a = 0.33 ± 0.06 μm). Based on these results, it was possible to conclude that the LMS implants' physical-chemical properties increased bone-implant interaction when compared to the MS implants. © 2009 Sociedade Brasileira de Pesquisa Odontológica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of soil drill rod length on the N value in the SPT-T test has been studied extensively by Mello (1971), Schmertmann & Palacios (1979), Odebrecht et al. (2002) and Cavalcante (2002). This paper presents an analysis of the Standard Penetration Test supplemented with torque measurement (SPT-T). A theoretical study of the resistance of the rod material to torsion and bending indicated that the shear stress caused by the rod self-weight represents less than 1% of that caused by the torsional moment. An experimental study with electric torquemeters attached to a horizontal rod system, as well as two field tests in the vertical direction, were also carried out to compare and substantiate the results. The purpose of these tests was to analyze changes along the length of the rod in response to successive increments at 1-meter intervals. Torque measurements were taken at each increment of the length to ascertain the accuracy of the theoretical data. The difference between the applied torque and the measured torque at the end of rod system was lower than the minimum scale of mechanical torquemeters used in practice.