874 resultados para Time-varying covariance matrices
Resumo:
The estimation of the carbon dioxide (CO2) fluxes above the open ocean plays an important role for the determination of the global carbon cycle. A frequently used method therefore is the eddy-covariance technique, which is based on the theory of the Prandl-layer with height-constant fluxes in the atmospheric boundary layer. To test the assumption of the constant flux layer, in 2008 measurements of turbulent heat and CO2 fluxes were started within the project Surface Ocean Processes in the Anthropocene (SOPRAN) at the research platform FINO2. The FINO2 platform is situated in the South-west of the Baltic Sea, in the tri-border region between Germany, Denmark, and Sweden. In the frame of the Research project SOPRAN, the platform was equipped with additional sensors in June 2008. A combination of 3-component sonic anemometers (USA-1) and open-path infrared gas analyzers for absolute humidity (H2O) and CO2 (LICOR 7500) were installed at a 9m long boom directed southward of the platform in two heights, at 6.8 and 13.8m above sea surface. Additionally slow temperature and humidity sensors were installed at each height. The gas analyzer systems were calibrated before the installation and worked permanently without any calibration during the first measurement period of one and a half years. The comparison with the measurements of the slow sensors showed for both instruments no significant long-term drift in H2O and CO2. Drifts on smaller time scales (in the order of days) due to the contamination with sea salt, were cleaned naturally by rain. The drift of both quantities had no influence on the fluctuation, which, in contrast to the mean values, are important for the flux estimation. All data were filtered due to spikes, rain, and the influence of the mast. The data set includes the measurements of all sensors as average over 30 minutes each for one and a half years, June 2008 to December 2009, and 10 month from November 2011 to August 2012. Additionally derived quantities for 30 minutes intervals each, like the variances for the fast-sensor variables, as well as the momentum, sensible and latent heat, and CO2 flux are presented.
Resumo:
We are investigating the performances of a data acquisition system for Time of Flight PET, based on LYSO crystal slabs and 64 channels Silicon Photomultipliers matrices (1.2 cm2 of active area each). Measurements have been performed to test the timing capability of the detection system (SiPM matices coupled to a LYSO slab and the read-out electronics) with both test signal and radioactive source.
Resumo:
Electrodynamic tethered systems, in which an exposed portion of the conducting tether itself collects electrons from the ionosphere, promise to attain currents of 10 A or more in low Earth orbit. For the first time, another desirable feature of such bare-tether systems is reported and analyzed in detail: Collection by a bare tether is relatively insensitive to variations in electron density that are regularly encountered on each revolution of an orbit. This self-adjusting property of bare-tether systems occurs because the electron-collecting area on the tether is not fixed, but extends along its positively biased portion, and because the current varies as collecting length to a power greater than unity. How this adjustment to density variations follows from the basic collection law of thin cylinders is shown. The effect of variations in the motionally induced tether voltage is also analyzed. Both power and thruster modes are considered. The performance of bare-tether systems to tethered systems is compared using passive spherical collectors of fixed area, taking into consideration recent experimental results. Calculations taking into account motional voltage and plasma density around a realistic orbit for bare-tether systems suitable for space station applications are also presented.
Resumo:
As additivity is a very useful property for a distance measure, a general additive distance is proposed under the stationary time-reversible (SR) model of nucleotide substitution or, more generally, under the stationary, time-reversible, and rate variable (SRV) model, which allows rate variation among nucleotide sites. A method for estimating the mean distance and the sampling variance is developed. In addition, a method is developed for estimating the variance-covariance matrix of distances, which is useful for the statistical test of phylogenies and molecular clocks. Computer simulation shows (i) if the sequences are longer than, say, 1000 bp, the SR method is preferable to simpler methods; (ii) the SR method is robust against deviations from time-reversibility; (iii) when the rate varies among sites, the SRV method is much better than the SR method because the distance is seriously underestimated by the SR method; and (iv) our method for estimating the sampling variance is accurate for sequences longer than 500 bp. Finally, a test is constructed for testing whether DNA evolution follows a general Markovian model.
Resumo:
Neste trabalho de doutorado utilizou-se um reator anaeróbio em batelada seqüencial contendo biomassa imobilizada em matrizes cúbicas de espuma de poliuretano e agitação mecânica, com volume total de 5.5 L e volume útil de 4.5 L. A agitação do meio líquido foi realizada com quatro tipos de impelidores (turbina tipo hélice, lâminas planas, lâminas planas inclinadas e lâminas curvas, testados individualmente, sempre em número de 3), com 6 cm de diâmetro. A pesquisa foi realizada em quatro etapas experimentais. A etapa 1 objetivou determinar o tempo de mistura no reator para cada tipo de impelidor, ou seja, o tempo necessário para que o meio líquido ficasse totalmente homogêneo. A etapa 2 objetivou selecionar o tipo de impelidor e a respectiva intensidade de agitação que garantisse a minimização da resistência à transferência de massa externa no sistema. As intensidades de agitação testadas variaram de 200 a 1100 rpm, dependendo do tipo de impelidor. A etapa 3 foi realizada com tipo de impelidor e intensidade de agitação definidos na etapa 2, mas variando-se o tamanho da biopartícula (0,5, 1,0, 2,0 e 3,0 cm de aresta). O objetivo desta etapa foi selecionar o tamanho de biopartícula que minimizasse a resistência à transferência de massa interna. De posse das condições operacionais otimizadas (tipo de impelidor, intensidade de agitação e tamanho de partícula de suporte), a etapa 4 constituiu na aplicação das mesmas para o tratamento de um resíduo real, sendo escolhida água residuária de suinocultura. Na etapa 1, os resultados mostraram que os tempos de mistura para todos os tipos de impelidores foram desprezíveis em relação ao tempo total de ciclo. A etapa 2 revelou tempos de partida muito curtos (cerca de 20 dias), em todas as condições testadas, sendo atingidas remoções de DQO próximas de 70%. Além disso, o tipo de impelidor exerceu grande influência na qualidade final do efluente, fato este claramente constatado quando as frações de DQO foram consideradas separadamente (filtrada e suspensa). De acordo com os resultados obtidos na etapa 3, o tamanho da biopartícula teve influência decisiva no desempenho do sistema, nas condições testadas. As velocidades de dissolução foram aparentemente influenciadas pelo empacotamento do leito de espuma, enquanto que o consumo da fração de DQO correspondente às amostras filtradas foi provavelmente influenciado por fatores mais complexos. Finalmente, o teste realizado com resíduo diluído de suinocultura demonstrou que a operação do reator em estudo para o tratamento deste tipo de água residuária é possível. Os dados operacionais mostraram que o reator permaneceu estável durante o período testado. A agitação mecânica provou ser eficiente para melhorar a degradação da DQO suspensa, um dos maiores problemas no tratamento deste tipo de água residuária. Sendo assim, de acordo com os dados experimentais obtidos ao longo do trabalho, pode-se afirmar que a agitação em reatores em batelada mostrou-se importante não somente para proporcionar boas condições de mistura ou melhorar a transferência de massa na fase líquida, mas também para melhorar a solubilização da matéria orgânica particulada, melhorando as velocidades de consumo de matéria orgânica.
Resumo:
In presenting their priorities for the new European Commission, Miroslav Beblavý and Ilaria Maselli assert in this CEPS Commentary that the time has come to devise an EU-level shock absorption mechanism. In their view, the instrument that best aligns varying political and economic objectives is a form of reinsurance of national systems of unemployment insurance. The primary motivation for the reinsurance proposal is that it can have a substantial stabilising effect, especially in case of large shocks, and, at the same time, be politically realistic in terms of contributions, costs and administrative burdens.