979 resultados para Thoracic computed tomography scan


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: avaliar as alterações nas inclinações dos dentes anteriores causadas pelo tratamento ortodôntico, utilizando-se aparelho Straight-Wire, prescrição II Capelozza, antes e após a fase de nivelamento com fios ortodônticos de aço de secção retangular. MÉTODOS: foram selecionados 17 indivíduos adultos de padrão facial II, má oclusão Classe II, indicados para tratamento ortodôntico compensatório. As inclinações dos dentes anteriores foram avaliadas em três tempos clínicos, após o uso dos fios ortodônticos de diâmetros 0,020" (T1); 0,019" x 0,025" (T2) e 0,021" x 0,025" (T3), através de exames de tomografia computadorizada. Empregou-se a análise de variância de Friedman, com nível de significância de 5%, na comparação entre os tempos. RESULTADOS: observou-se que o fios retangulares empregados não foram capazes de produzir uma mudança significativa na mediana da inclinação dentária, exceto por uma discreta alteração nos incisivos laterais inferiores (p<0,05). Por outro lado, constatou-se que a variação das inclinações observadas era menor no fio retangular 0,021" x 0,025", principalmente para os incisivos superiores (p<0,001). CONCLUSÃO: fios retangulares 0,021" x 0,025" produzem uma maior homogeneidade no grau de variação na inclinação dos incisivos superiores, embora sem mudança significativa na sua mediana.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: a espessura das tábuas ósseas que recobrem os dentes por vestibular e lingual constitui um dos fatores limitantes da movimentação dentária. O avanço tecnológico em Imaginologia permitiu avaliar detalhadamente essas regiões anatômicas por meio da utilização da tomografia computadorizada de feixe cônico (TCFC). OBJETIVO: descrever e padronizar, pormenorizadamente, um método para mensuração das tábuas ósseas vestibular e lingual dos maxilares nas imagens de tomografia computadorizada de feixe cônico. METODOLOGIA: a padronização digital da posição da imagem da face deve constituir o primeiro passo antes da seleção dos cortes de TCFC. Dois cortes axiais de cada maxilar foram empregados para a mensuração da espessura do osso alveolar vestibular e lingual. Utilizou-se como referência a junção cemento-esmalte dos primeiros molares permanentes, tanto na arcada superior quanto na inferior. RESULTADOS: cortes axiais paralelos ao plano palatino foram indicados para avaliação quantitativa do osso alveolar na maxila. Na arcada inferior, os cortes axiais devem ser paralelos ao plano oclusal funcional. CONCLUSÃO: o método descrito apresenta reprodutibilidade para utilização em pesquisas, assim como para a avaliação clínica das repercussões periodontais da movimentação dentária, ao permitir a comparação de imagens pré e pós-tratamento.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The identification of the mandibular canal (MC) is an important prerequisite for surgical procedures involving the posterior mandible. Cone beam computed tomography (CBCT) represents an advance in imaging technology, but distinguishing the MC from surrounding structures may remain a delicate task. OBJECTIVES: The aim of this study was to assess the visibility of the MC in different regions on CBCT cross-sectional images. MATERIAL AND METHODS: CBCT cross-sectional images of 58 patients (116 hemi-mandibles) were analyzed, and the visibility of the MC in different regions was assessed. RESULTS: The MC was clearly visible in 53% of the hemi-mandibles. Difficult and very difficult visualizations were registered in 25% and 22% of the hemi-mandibles, respectively. The visibility of the MC on distal regions was superior when compared to regions closer to the mental foramen. No differences were found between edentulous and tooth-bearing areas. CONCLUSIONS: The MC presents an overall satisfactory visibility on CBCT cross-sectional images in most cases. However, the discrimination of the canal from its surrounds becomes less obvious towards the mental foramen region when cross-sectional images are individually analyzed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: o exame de tomografia computadorizada de feixe cônico (TCFC) oferece excelente representação dos tecidos duros da articulação temporomandibular (ATM). OBJETIVO: investigar as alterações morfológicas do côndilo mandibular, da infância à idade adulta, utilizando a TCFC. MÉTODOS: um estudo transversal foi conduzido envolvendo 36 côndilos de 18 indivíduos com idades variando entre 3 e 20 anos. As imagens dos côndilos foram obtidas por meio do sistema i-CAT e medidas com uma ferramenta do programa específica para ATM, que permite cortes perpendiculares à cabeça do côndilo, com correção individual em função das diferenças angulares de cada um. As maiores distâncias nas vistas lateral e frontal foram consideradas tanto para os côndilos do lado direto como para os do lado esquerdo. RESULTADOS: a dimensão lateral do côndilo mandibular parece ser estabelecida de maneira precoce, sofrendo poucas alterações com o passar dos anos, enquanto a dimensão frontal tende a aumentar. Assimetrias entre o côndilo esquerdo e o direito foram comumente observadas; no entanto, tais diferenças não apresentaram significância estatística para as vistas lateral (P=0,815) e frontal (P=0,374). CONCLUSÕES: os côndilos apresentaram simetria com relação ao tamanho, sendo observado crescimento apenas na dimensão frontal Os resultados sugerem que a TCFC constitui-se numa ferramenta útil na mensuração e avaliação das dimensões condilares.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: determinar as medidas lineares dos estágios de desenvolvimento da dentição permanente humana, usando tomografia computadorizada de feixe cônico (TCFC). MÉTODOS: este estudo foi desenvolvido a partir de bancos de dados de clínicas radiológicas privadas, envolvendo 18 pacientes (13 do sexo masculino, 5 do sexo feminino, com idades variando entre 3 e 20 anos). As imagens das TCFC foram obtidas por meio do sistema i-CAT e medidas com uma função específica do programa desse mesmo sistema. Duzentos e trinta e oito dentes foram analisados, em diferentes estágios de desenvolvimento, nos planos coronal e sagital. O método foi baseado na delimitação e mensuração das distâncias entre pontos anatômicos correspondentes ao desenvolvimento das coroas e raízes dentárias. A partir dos valores obtidos, pôde-se desenvolver um modelo quantitativo para se avaliar os estágios inicial e final de desenvolvimento para todos os grupos dentários. RESULTADOS E CONCLUSÕES: as medidas obtidas dos diferentes grupos dentários estão de acordo com as estimativas das investigações publicadas previamente. As imagens por TCFC dos diferentes estágios de desenvolvimento podem contribuir no diagnóstico, planejamento e resultado dos tratamentos em diversas especialidades odontológicas. As dimensões das coroas e das raízes dentárias podem ter importantes aplicações clínicas e em pesquisas, constituindo uma técnica não invasiva que contribui com estudos in vivo. Entretanto, mais estudos são recomendados a fim de minimizar possíveis variáveis metodológicas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Maxillary sinus lifting is a technique, in which, a possible complication is sinus membrane perforation. The aim of this study was to compare two techniques using ultrasound surgery to perform autogenous graft for maxillary sinus lifting. METHODS: Ten rabbits were used in the study, one of them did not undergo surgery. The other nine rabbits had their maxillary sinuses filled with autogenous bone grafts collected from the external skull diploe in particulate form on the right side, and shaved on the left side, both with ultrasonic device. Data on bone density in left and right maxillary sinus, obtained by computed tomography in transverse and longitudinal sections, recorded 90 days after the grafts, were statistically compared. RESULTS: There were no statistically significant differences between the two techniques that used shaved and particulate bone collected by means of ultrasonic device from rabbit skulls. CONCLUSION: Assessment of operative procedures led to the conclusion that piezoelectric ultrasound was shown to be a safe tool in the surgical approach to the maxillary sinus of rabbits, allowing sinus membrane integrity to be maintained during surgical procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Osteochondroma of the mandibular condyle has been found in the oral and maxillofacial region rarely. This paper describes a case of osteochondroma of the mandibular condyle in a 20-year-old woman, who was referred to our service with facial asymmetry, prognathic deviation of chin, cross-bite to the contralateral side, changes in condylar morphology, limited mouth opening, and malocclusion. Computed tomography (CT) was performed for better evaluation to the pathological conditions on the temporomandibular joint. Based on the clinical examination, patient history, and complementary exams, the hypothesis of osteochondroma was established. Condylectomy was performed using a preauricular approach with total removal of the lesion. After 3 years of postoperative follow up and orthodontic therapy, the patient is symptom-free, and has normal mouth opening with no deviation in the opening pattern.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Juvenile idiopathic arthritis (JIA) has unknown etiology, and the involvement of the temporomandibular joint (TMJ) is rare in the early phase of the disease. The present article describes the use of computed tomography (CT) and magnetic resonance (MRI) images for the diagnosis of affected TMJ in JIA. CASE DESCRIPTION: A 12-year-old, female, Caucasian patient, with systemic rheumathoid arthritis and involvement of multiple joints was referred to the Imaging Center for TMJ assessment. The patient reported TMJ pain and limited opening of the mouth. The helical CT examination of the TMJ region showed asymmetric mandibular condyles, erosion of the right condyle and osteophyte-like formation. The MRI examination showed erosion of the right mandibular condyle, osteophytes, displacement without reduction and disruption of the articular disc. CONCLUSION: The disorders of the TMJ as a consequence of JIA must be carefully assessed by modern imaging methods such as CT and MRI. CT is very useful for the evaluation of discrete bone changes, which are not identified by conventional radiographs in the early phase of JIA. MRI allows the evaluation of soft tissues, the identification of acute articular inflammation and the differentiation between pannus and synovial hypertrophy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To verify if uterine cerclage can induce craniosynostosis or any cranial deformity in new born Wistar rats. METHODS: One pregnant female Wistar rat underwent laparotomy on day 18 of gestation and the uterus cervix was closed with a 3-0 nylon suture to avoid delivery, that occurs normally on the 21 day. The suture was released after 48 hours beyond the normal gestation period. The female rat delivered 11 pups. Six surviving rats from the delivery (group A - constrained group). Two rats were born from another mother and in the same age were used as control group (group B - 2 nonconstrained controls) were allowed to grow. They were sacrificed 1.2 years after their birth all the eight animals. Linear measurement, routine histology and computed tomography of the skull were performed at the time of their death to evaluate the cranial asymmetries by mesurements of the anatomical landmarks of the craniofacial skeleton of the rats on the two groups and compared then. RESULTS: We did not observe statistically significant differences in any of the compared measurements (p>0.05) obtained through the morphologic and radiologic methods. Histologic examinations did not reveal any sign of premature fusion or suture imbrications. Critical decrease in longitudinal body size was noticed as the limbs too in all the animals of group A. CONCLUSION: Constriction of uterine cervix leads to fetus suffering, even death for a few animals, associated to small body size, but not to craniosynostosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The Shwachman-Kulczycki score was the first scoring system used in cystic fibrosis to assess disease severity. Despite its subjectivity, it is still widely used. OBJECTIVE: To study correlations among forced expiratory volume in one second (FEV1), chest radiography, chest computed tomography, 6-minute walk test, and Shwachman-Kulczycki score in patients with cystic fibrosis and to test whether the Shwachman-Kulczycki score is still useful in monitoring the severity of the disease. METHODS: A cross-sectional prospective study was performed to analyze the correlations (Spearman). Patients with clinically stable cystic fibrosis, aged 3-21 years, were included. RESULTS: 43 patients, 19F/24M, mean age 10.5 + 4.7 years, with a median Shwachman-Kulczycki score of 70 were studied. The median Brasfield and Bhalla scores were 17 and 10, respectively. The mean Z score for the 6-minute walk test was -1.1 + 1.106 and the mean FEV1 was 59 + 26 (as percentage of predicted values). The following significant correlations versus the Shwachman-Kulczycki score were found: FEV1 (r = 0.76), 6-minute walk test (r = 0.71), chest radiography (r = 0.71) and chest computed tomography (r = -0.78). When patients were divided according to FEV1, a statistically significantly correlation with the Shwachman-Kulczycki score was found only in patients with FEV1 <70% (r = 0.67). CONCLUSIONS: The Shwachman-Kulczycki score remains an useful tool for monitoring the severity of cystic fibrosis, adequately reflecting the functional impairment and chest radiography and tomography changes, especially in patients with greater impairment of lung function. When assessing patients with mild lung disease its limitations should be considered and its usefulness in such patients should be evaluated in larger populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

FUNDAMENTO: Apesar de algumas evidências sugerirem associação entre a exposição de uma tecnologia na literatura científica e sua difusão na prática clínica, poucos estudos avaliaram essa associação. OBJETIVO: O objetivo deste estudo é analisar se o padrão de publicação científica sobre duas tecnologias competitivas utilizadas na avaliação da doença arterial coronária (DAC) reflete o que ocorre na prática clínica. MÉTODOS: Avaliou-se o número de artigos científicos publicados anualmente na literatura médica (interesse científico global na tecnologia) sobre duas tecnologias utilizadas na avaliação da doença arterial coronária: tomografia computadorizada por feixe de elétrons e tomografia computadorizada com múltiplos detectores. Foi também analisado o número de países que publicam anualmente artigos científicos sobre essas tecnologias (interesse geográfico na tecnologia). RESULTADOS: A tomografia computadorizada por feixe de elétrons (electron beam computed tomography - EBCT) apresentou ápice de "interesse científico global" em 2001, com 127 artigos publicados. Após esse ápice, o "interesse científico global" diminuiu cerca de 50% em 2008. Em oposição, o "interesse científico global" pela tomografia computadorizada com múltiplos detectores (multidetector computed tomography - MDCT) aumentou progressivamente até 2007, com 454 artigos publicados nesse ano. O "interesse científico geográfico" pela EBCT teve ápice em 2002, com 14 países publicando sobre essa tecnologia. Após esse ápice, "o interesse científico geográfico" declinou em quase 25% até 2008, com 11 países publicando artigos sobre essa tecnologia. Em oposição, o "interesse científico geográfico" pela MDCT aumentou progressivamente até 2008, com 37 países publicando artigos sobre ela. CONCLUSÃO: A literatura científica médica é compatível com a substituição da EBCT pela MDCT na avaliação da DAC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Treatment of multinodular goiters (MNGs) is highly controversial. Radioiodine (RAI) therapy is a nonsurgical alternative for the elderly who decline surgery. Recently, recombinant human thyrotropin (rhTSH) has been used to augment RAI uptake and distribution. In this study, we determined the outcome of 30 mCi RAI preceded by rhTSH (0.1 mg) in euthyroid (EU) and hyperthyroid (subclinical/clinical) patients with large MNGs. Methods: This was a prospective cohort study. Forty-two patients (age, 43-80 years) with MNGs were treated with 30 mCi RAI after stimulation with 0.1 mg of rhTSH. Patients were divided into three groups, according to thyroid function: EU (n = 18), subclinically hyperthyroid (SC-H, n = 18), and clinically hyperthyroid (C-H, n = 6). All patients underwent a 90-day low-iodine diet before treatment, and those with clinical hyperthyroidism received methimazole 10 mg daily for 30 days. Serum TSH, free thyroxine (FT4), total triiodothyronine (TT3), and thyroglobulin were measured at baseline and at 24, 48, 72, 168 hours, and 1, 3, 6, 9, 12, 18, 24, and 36 months after therapy. Thyroid volume was assessed by computed tomography at baseline and every 6 months. Results: Patients had high iodine urinary excretion (308 +/- 108 mu g I/L) at baseline. TSH levels at baseline were within the normal range (1.5 +/- 0.7 mu U/mL) in the EU group and suppressed (< 0.3 mu U/mL) in the SC-H and C-H groups. After rhTSH, serum TSH peaked at 24 hours reaching 12.4 +/- 5.85 mu U/mL. After RAI administration, patients in both hyperthyroid groups had a higher increase in FT4 and TT3 compared with those in the EU group (p < 0.001). Thyroglobulin levels increased equally in all three groups until day 7. Thyroid volume decreased significantly in all patients. Side effects were more common in the SC-H and C-H groups (31.4% and 60.4%, respectively) compared with EU patients (17.8%). Permanent hypothyroidism was more prevalent in the EU group (50%) compared with the SC-H (11%) and C-H (16.6%) groups. Conclusions: Patients with MNG may have subclinical and clinical nonautoimmune iodine-induced hyperthyroidism. Despite a low-iodine diet and therapy with methimazole, hyperthyroid patients have a significantly higher increase in FT4 and TT3 levels after RAI ablation. This can lead to important side effects related mostly to the cardiac system. We strongly advise that patients with SC-H and C-H be adequately treated with methimazole and low-iodine diet aiming to normalize their hyperthyroid condition before rhTSH-stimulated treatment with RAI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the frequency of the genetic markers HLA-DRB1 and DQB1 in patients with Graves' orbitopathy ( GO) with and without extraocular muscle involvement. Design: The frequencies of class II HLA-DRB1 and DQB1 allele groups were determined for 81 Brazilian patients with GO and 161 normal subjects. The patients were divided into myogenic and nonmyogenic groups based on the clinical characteristics of the orbitopathy and quantitative computed tomography analysis of the extraocular muscle ( EOM) dimensions. Main outcome: Compared to the frequency obtained for samples of normal subjects of the Brazilian population, HLA-DRB1*16 (p(c)= 0.008) was overrepresented in myogenic and HLA-DRB1*03 (p(c)= 0.02) in nonmyogenic patients. Conclusions: The association between the HLA-DRB1* 16 and the myogenic subtype of GO suggests that EOM involvement in GO may be genetically predisposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work discusses the determination of the breathing patterns in time sequence of images obtained from magnetic resonance (MR) and their use in the temporal registration of coronal and sagittal images. The registration is made without the use of any triggering information and any special gas to enhance the contrast. The temporal sequences of images are acquired in free breathing. The real movement of the lung has never been seen directly, as it is totally dependent on its surrounding muscles and collapses without them. The visualization of the lung in motion is an actual topic of research in medicine. The lung movement is not periodic and it is susceptible to variations in the degree of respiration. Compared to computerized tomography (CT), MR imaging involves longer acquisition times and it is preferable because it does not involve radiation. As coronal and sagittal sequences of images are orthogonal to each other, their intersection corresponds to a segment in the three-dimensional space. The registration is based on the analysis of this intersection segment. A time sequence of this intersection segment can be stacked, defining a two-dimension spatio-temporal (2DST) image. The algorithm proposed in this work can detect asynchronous movements of the internal lung structures and lung surrounding organs. It is assumed that the diaphragmatic movement is the principal movement and all the lung structures move almost synchronously. The synchronization is performed through a pattern named respiratory function. This pattern is obtained by processing a 2DST image. An interval Hough transform algorithm searches for synchronized movements with the respiratory function. A greedy active contour algorithm adjusts small discrepancies originated by asynchronous movements in the respiratory patterns. The output is a set of respiratory patterns. Finally, the composition of coronal and sagittal image pairs that are in the same breathing phase is realized by comparing of respiratory patterns originated from diaphragmatic and upper boundary surfaces. When available, the respiratory patterns associated to lung internal structures are also used. The results of the proposed method are compared with the pixel-by-pixel comparison method. The proposed method increases the number of registered pairs representing composed images and allows an easy check of the breathing phase. (C) 2010 Elsevier Ltd. All rights reserved.