1000 resultados para Test diagnostique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intravoxel incoherent motion (IVIM) MRI is a method to extract microvascular blood flow information out of diffusion-weighted images acquired at multiple b-values. We hypothesized that IVIM can identify the muscles selectively involved in a specific task, by measuring changes in activity-induced local muscular perfusion after exercise. We tested this hypothesis using a widely used clinical maneuver, the lift-off test, which is known to assess specifically the subscapularis muscle functional integrity. Twelve shoulders from six healthy male volunteers were imaged at 3 T, at rest, as well as after a lift-off test hold against resistance for 30 s, 1 and 2 min respectively, in three independent sessions. IVIM parameters, consisting of perfusion fraction (f), diffusion coefficient (D), pseudo-diffusion coefficient D* and blood flow-related fD*, were estimated within outlined muscles of the rotator cuff and the deltoid bundles. The mean values at rest and after the lift-off tests were compared in each muscle using a one-way ANOVA. A statistically significant increase in fD* was measured in the subscapularis, after a lift-off test of any duration, as well as in D. A fD* increase was the most marked (30 s, +103%; 1 min, +130%; 2 min, +156%) and was gradual with the duration of the test (in 10(-3) mm(2) /s: rest, 1.41 ± 0.50; 30 s, 2.86 ± 1.17; 1 min, 3.23 ± 1.22; 2 min, 3.60 ± 1.21). A significant increase in fD* and D was also visible in the posterior bundle of the deltoid. No significant change was consistently visible in the other investigated muscles of the rotator cuff and the other bundles of the deltoid. In conclusion, IVIM fD* allows the demonstration of a task-related microvascular perfusion increase after a specific task and suggests a direct relationship between microvascular perfusion and the duration of the effort. It is a promising method to investigate non-invasively skeletal muscle physiology and clinical perfusion-related muscular disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Los últimos acontecimientos en materia de salud, como la aparición del SARS (síndrome agudo respiratorio severo) y el aumento de las infecciones nosocomiales han vuelto a poner en debate la importancia de que se apliquen las precauciones estándar por parte de todo el personal sanitario. Si bien las precauciones estándar están protocolizadas en la mayoría de los centros de salud de nuestro país, existe una gran confusión y desconocimiento al respecto

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Los últimos acontecimientos en materia de salud, como la aparición del SARS (síndrome agudo respiratorio severo) y el aumento de las infecciones nosocomiales han vuelto a poner en debate la importancia de que se apliquen las precauciones estándar por parte de todo el personal sanitario. Si bien las precauciones estándar están protocolizadas en la mayoría de los centros de salud de nuestro país, existe una gran confusión y desconocimiento al respecto

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We aimed to a) introduce a new Test to Exhaustion Specific to Tennis (TEST) and compare performance (test duration) and physiological responses to those obtained during the 20-m multistage shuttle test (MSST), and b) determine to which extent those variables correlate with performance level (tennis competitive ranking) for both test procedures. METHODS: Twenty-seven junior players (8 males, 19 females) members of the national teams of the French Tennis Federation completed MSST and TEST, including elements of the game (ball hitting, intermittent activity, lateral displacement), in a randomized order. Cardiorespiratory responses were compared at submaximal (respiratory compensation point) and maximal loads between the two tests. RESULTS: At the respiratory compensation point oxygen uptake (50.1 +/- 4.7 vs. 47.5 +/- 4.3 mL.min-1.kg-1, p = 0.02), but not minute ventilation and heart rate, was higher for TEST compared to MSST. However, load increment and physiological responses at exhaustion did not differ between the two tests. Players' ranking correlated negatively with oxygen uptake measured at submaximal and maximal loads for both TEST (r = -0.41; p = 0.01 and -0.55; p = 0.004) and MSST (r = -0.38; P = 0.05 and -0.51; p = 0.1). CONCLUSION: Using TEST provides a tennis-specific assessment of aerobic fitness and may be used to prescribe aerobic exercise in a context more appropriate to the game than MSST. Results also indicate that VO2 values both at submaximal and maximal load reached during TEST and MSST are moderate predictors of players competitive ranking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: CD103 is a specific integrin present on some CD4+ lymphocytes of the mucosal immune system. It has been hypothesized that most CD4+ lymphocytes in pulmonary sarcoidosis do not originate from mucosal sites but from redistribution from the peripheral blood, and therefore do not bear the CD103 integrin. Several studies have suggested that a low CD103+ percentage among bronchoalveolar lavage (BAL) CD4+ lymphocytes discriminates between sarcoidosis and other causes of lymphocytic alveolitis, but contradictory data exist. Methods: We reviewed 1151 consecutive patients with BAL lymphocytosis >10% and flow cytometry performed between 2006 and 2014. 944 cases were excluded due to poor BAL quality (n= 97), unavailable clinical data (n= 760), or unclear diagnosis (n= 87). The remaining 207 patients were grouped into 9 diagnostic categories. To assess the discriminative value of the CD103+CD4+/CD4+ ratio to distinguish sarcoidosis from the other entities, area under ROC curves (AUC) were determined. Results: Sarcoidosis patients (n=53) had a lower CD103+CD4+/CD4+ ratio than the other diagnostic categories. AUC was 62% for sarcoidosis compared to all other patients and 69% for sarcoidosis compared to other interstitial lung diseases. When combining CD103+CD4+/CD4+ and CD4+/CD8+ ratios, AUC increased to 76% and 78% respectively. When applying published cut-offs from 4 previous studies to our population, AUC varied between 54 and 73%. Conclusions: The CD103+CD4+/CD4+ ratio does not accurately discriminate between sarcoidosis and other causes of lymphocytic alveolitis, neither alone nor in combination with CD4+/CD8+ ratio, and is not a relevant marker for the diagnosis of sarcoidosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conocer cuál es la personalidad de aquellos que acceden a nuestras Escuelas y que en pocos años se convertirán en futuros profesionales de Enfermería, ha sido el objetivo de un estudio llevado a cabo por la Comisión de Docencia de la E.U.E. de Barcelona. En él se realiza un análisis comparativo de los perfiles de personalidad de los estudiantes admitidos en la E.U.E. de Barcelona y los candidatos pre-inscritos en dicha escuela en 1983, frente a estudiantes de Enfermería americanas y británicas y los candidatos a estudiantes de Medicina de la Universidad de Navarra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La maladie de Kawasaki (KD) est une vasculite aiguë qui touche principalement les enfants de moins de 5 ans. Les manifestations cardio-vasculaires sont la cause principale de morbidité et mortalité à long terme. Bien qu'étant autolimitée dans le temps et souvent spontanément résolutive, KD peut avoir des conséquences sérieuses liées notamment à l'apparition d'anévrysmes coronaires (CAA) qui peuvent engendrer thrombose, sténose et infarctus myocardique (IM), voire même mort subite, d'où la nécessité de prendre en charge rapidement et correctement ces enfants.1,2 En l'absence de test de laboratoire ou de signe clinique spécifique, KD est difficile à identifier et se diagnostique sur la base de critères cliniques et de différents paramètres de laboratoire. Le premier cas de KD a été observé dans les années 60, et aujourd'hui encore de nombreuses questions persistent: la cause exacte reste inconnue, bien que de nombreuses études évoquent un probable rôle infectieux et une prédisposition génétique.3 De plus, étant une maladie relativement "jeune", les effets cardio-vasculaires et le devenir des patients à long terme sont peu connus. Enfin, il manque un test spécifique qui permettrait un diagnostic de certitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the primary goals for food packages is to protect food against harmful environment, especially oxygen and moisture. The gas transmission rate is the total gas transport through the package, both by permeation through the package material and by leakage through pinholes and cracks. The shelf life of a product can be extended, if the food is stored in a gas tight package. Thus there is a need to test gas tightness of packages. There are several tightness testing methods, and they can be broadly divided into destructive and nondestructive methods. One of the most sensitive methods to detect leaks is by using a non destructive tracer gas technique. Carbon dioxide, helium and hydrogen are the most commonly used tracer gases. Hydrogen is the lightest and the smallest of all gases, which allows it to escape rapidly from the leak areas. The low background concentration of H2 in air (0.5 ppm) enables sensitive leak detection. With a hydrogen leak detector it is also possible to locate leaks. That is not possible with many other tightness testing methods. The experimental work has been focused on investigating the factors which affect the measurement results with the H2leak detector. Also reasons for false results were searched to avoid them in upcoming measurements. From the results of these experiments, the appropriate measurement practice was created in order to have correct and repeatable results. The most important thing for good measurement results is to keep the probe of the detector tightly against the leak. Because of its high diffusion rate, the HZ concentration decreases quickly if holding the probe further away from the leak area and thus the measured H2 leaks would be incorrect and small leaks could be undetected. In the experimental part hydrogen, oxygen and water vapour transmissions through laser beam reference holes (diameters 1 100 μm) were also measured and compared. With the H2 leak detector it was possible to detect even a leakage through 1 μm (diameter) within a few seconds. Water vapour did not penetrate even the largest reference hole (100 μm), even at tropical conditions (38 °C, 90 % RH), whereas some O2 transmission occurred through the reference holes larger than 5 μm. Thus water vapour transmission does not have a significant effect on food deterioration, if the diameter of the leak is less than 100 μm, but small leaks (5 100 μm) are more harmful for the food products, which are sensitive to oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fiscal policy rule implicit in the Stability and Growth Pact, has been rationalised as a way to ensure that national fiscal policies remain sustainable within the EU, thereby endorsing the independence of the ECB. We empirically examine the sustainability of European fiscal policies over the period 1970-2001. The intertemporal government budget constraint provides a test based on the cointegration relation between government revenues, expenditures and interest payments. Sustainability is analysed at both the national level and for a European panel. Results show that European fiscal policy has been sustainable overall, yet national experiences differ considerably.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The void structure of zeolites MCM-22, MCM-36 and ITQ-2 were discussed on the bases of catalytic reaction tests. The hydromerization of n-decane on bifunctional Pt/Zeolite Catalysts have been used as model reactions. Beta and ZSM-5 zeolites were used for comparison. It is concluded that all materials show features of 10MR zeolites and have also pores bigger than 12MR in this order MCM-22