902 resultados para System for energy certification of buildings


Relevância:

100.00% 100.00%

Publicador:

Resumo:

On Wednesday 11th May 2011 at 6:47 pm (local time) a magnitude 5.1 Mw earthquake occurred 6 km northeast of Lorca with a depth of around 5 km. As a consequence of the shallow depth and the small epicentral distance, important damage was produced in several masonry constructions and even led to the collapse of one of them. Pieces of the facades of several buildings fell down onto the sidewalk, being one of the reasons for the killing of a total of 9 people. The objective of this paper is to describe and analyze the failure patterns observed in reinforced concrete frame buildings with masonry infill walls ranging from 3 to 8 floors in height. Structural as well as non-structural masonry walls suffered important damage that led to redistributions of forces causing in some cases the failure of columns. The importance of the interaction between the structural frames and the infill panels is analyzed by means of non-linear Finite Element Models. The resulting load levels are compared with the member capacities and the changes of the mechanical properties during the seismic event are described and discussed. In the light of the results obtained the observed failure patterns are explained. Some comments are stated concerning the adequacy of the numerical models that are usually used during the design phase for the seismic analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we study non-negative radially symmetric solutions of a parabolic-elliptic Keller-Segel system. The system describes the chemotactic movement of cells under the additional circumstance that an external application of a chemo attractant at a distinguished point is introduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Quality of Life of a person may depend on early attention to his neurodevel-opment disorders in childhood. Identification of language disorders under the age of six years old can speed up required diagnosis and/or treatment processes. This paper details the enhancement of a Clinical Decision Support System (CDSS) aimed to assist pediatricians and language therapists at early identification and re-ferral of language disorders. The system helps to fine tune the Knowledge Base of Language Delays (KBLD) that was already developed and validated in clinical routine with 146 children. Medical experts supported the construction of Gades CDSS by getting scientific consensus from literature and fifteen years of regis-tered use cases of children with language disorders. The current research focuses on an innovative cooperative model that allows the evolution of the KBLD of Gades through the supervised evaluation of the CDSS learnings with experts¿ feedback. The deployment of the resulting system is being assessed under a mul-tidisciplinary team of seven experts from the fields of speech therapist, neonatol-ogy, pediatrics, and neurology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As advanced Cloud services are becoming mainstream, the contribution of data centers in the overall power consumption of modern cities is growing dramatically. The average consumption of a single data center is equivalent to the energy consumption of 25.000 households. Modeling the power consumption for these infrastructures is crucial to anticipate the effects of aggressive optimization policies, but accurate and fast power modeling is a complex challenge for high-end servers not yet satisfied by analytical approaches. This work proposes an automatic method, based on Multi-Objective Particle Swarm Optimization, for the identification of power models of enterprise servers in Cloud data centers. Our approach, as opposed to previous procedures, does not only consider the workload consolidation for deriving the power model, but also incorporates other non traditional factors like the static power consumption and its dependence with temperature. Our experimental results shows that we reach slightly better models than classical approaches, but simul- taneously simplifying the power model structure and thus the numbers of sensors needed, which is very promising for a short-term energy prediction. This work, validated with real Cloud applications, broadens the possibilities to derive efficient energy saving techniques for Cloud facilities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Una estructura vibra con la suma de sus infinitos modos de vibración, definidos por sus parámetros modales (frecuencias naturales, formas modales y coeficientes de amortiguamiento). Estos parámetros se pueden identificar a través del Análisis Modal Operacional (OMA). Así, un equipo de investigación de la Universidad Politécnica de Madrid ha identificado las propiedades modales de un edificio de hormigón armado en Madrid con el método Identificación de los sub-espacios estocásticos (SSI). Para completar el estudio dinámico de este edificio, se ha desarrollado un modelo de elementos finitos (FE) de este edificio de 19 plantas. Este modelo se ha calibrado a partir de su comportamiento dinámico obtenido experimentalmente a través del OMA. Los objetivos de esta tesis son; (i) identificar la estructura con varios métodos de SSI y el uso de diferentes ventanas de tiempo de tal manera que se cuantifican incertidumbres de los parámetros modales debidos al proceso de estimación, (ii) desarrollar FEM de este edificio y calibrar este modelo a partir de su comportamiento dinámico, y (iii) valorar la bondad del modelo. Los parámetros modales utilizados en esta calibración han sido; espesor de las losas, densidades de los materiales, módulos de elasticidad, dimensiones de las columnas y las condiciones de contorno de la cimentación. Se ha visto que el modelo actualizado representa el comportamiento dinámico de la estructura con una buena precisión. Por lo tanto, este modelo puede utilizarse dentro de un sistema de monitorización estructural (SHM) y para la detección de daños. En el futuro, podrá estudiar la influencia de los agentes medioambientales, tales como la temperatura o el viento, en los parámetros modales. A structure vibrates according to the sum of its vibration modes, defined by their modal parameters (natural frequencies, damping ratios and modal shapes). These parameters can be identified through Operational Modal Analysis (OMA). Thus, a research team of the Technical University of Madrid has identified the modal properties of a reinforced-concrete-frame building in Madrid using the Stochastic Subspace Identification (SSI) method and a time domain technique for the OMA. To complete the dynamic study of this building, a finite element model (FE) of this 19-floor building has been developed throughout this thesis. This model has been updated from its dynamic behavior identified by the OMA. The objectives of this thesis are to; (i) identify the structure with several SSI methods and using different time blocks in such a way that uncertainties due to the modal parameter estimation are quantified, (ii) develop a FEM of this building and tune this model from its dynamic behavior, and (iii) Assess the quality of the model, the modal parameters used in this updating process have been; thickness of slabs, material densities, modulus of elasticity, column dimensions and foundation boundary conditions. It has been shown that the final updated model represents the structure with a very good accuracy. Thus, this model might be used within a structural health monitoring framework (SHM). The study of the influence of changing environmental factors (such as temperature or wind) on the model parameters might be considered as a future work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main goal of the cofounded by the European Commission LIFE Project, New4Old (LIFE10 ENV/ES/439), is to define the most appropriate method and the best available practice in social housing rehabilitation with energy and environmental sustainability criteria, as well as to apply innovative technologies in the fight against climate change through an efficient use of resources and energy. The institutions involved in the Project are the Technological Centre AITEMIN, Madrid Polytechnic University (UPM), Portugal Technological Centre for Ceramics and Glass (CTCV) and the Zaragoza City Housing Society (SMZV). The demonstrator project consists in the energy rehabilitation of a rental social housing building located in Zaragoza?s historic quarter, according to the conclusions and strategies developed for the LIFE project. In actions taken in households of this nature passive design strategies are essential due to the limited income of owners, who often cannot afford energy bills. Therefore, the proposed actions will help improve the building?s passive performance and reach a higher thermal comfort, without increasing the economic cost linked to energy consumption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of fiber inclusion, feed form, and energy concentration of the diet on the growth performance of pullets from hatching to 5 wk age were studied in 2 experiments. In Experiment 1, there was a control diet based on cereals and soybean meal, and 6 extra diets that included 2 or 4% of cereal straw, sugar beet pulp (SBP), or sunflower hulls (SFHs) at the expense (wt/wt) of the whole control diet. From hatching to 5 wk age fiber inclusion increased (P < 0.05) ADG and ADFI, and improved (P < 0.05) energy efficiency (EnE; kcal AMEn/g ADG), but body weight (BW) uniformity was not affected. Pullets fed SFH tended to have higher ADG than pullets fed SBP (P = 0.072) with pullets fed straw being intermediate. The feed conversion ratio (FCR) was better (P < 0.05) with 2% than with 4% fiber inclusion. In Experiment 2, 10 diets were arranged as a 2×5 factorial with 2 feed forms (mash vs. crumbles) and 5 levels of AMEn (2,850, 2,900, 2,950, 3,000, and 3,050 kcal/kg). Pullets fed crumbles were heavier and had better FCR than pullets fed mash (P < 0.001). An increase in the energy content of the crumble diets reduced ADFI and improved FCR linearly, but no effects were detected with the mash diets (P < 0.01 and P < 0.05 for the interactions). Feeding crumbles tended to improve BW uniformity at 5 wk age (P = 0.077) but no effects were detected with increases in energy concentration of the diet. In summary, the inclusion of moderate amounts of fiber in the diet improves pullet performance from hatching to 5 wk age. The response of pullets to increases in energy content of the diet depends on feed form with a decrease in feed intake when fed crumbles but no changes when fed mash. Feeding crumbles might be preferred to feeding mash in pullets from hatching to 5 wk age.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of feed form and energy concentration of the diet on growth performance and the development of the gastrointestinal tract (GIT) was studied in brown-egg laying pullets. Diets formed a 2 x 5 factorial with 2 feed forms (mash vs. crumbles) and 5 levels of energy differing in 50 kcal AMEn/kg. For the entire study (0 to 17 wk of age) feeding crumbles increased ADFI (52.9 vs. 49.7 g; P < 0.001) and ADG (12.7 vs. 11.6 g; P < 0.001) and improved feed conversion ratio (FCR; 4.18 vs. 4.27; P < 0.001). An increase in the energy content of the diet decreased ADFI linearly (P < 0.001) and improved FCR quadratically (P < 0.01) but energy intake (kcal AMEn/d) was not affected. BW uniformity was higher (P < 0.05) in pullets fed crumbles than in those fed mash but was not affected (P > 0.05) by energy content of the diet. At 5, 10, and 17 wk of age, the relative weight (RW, % BW) of the GIT and the gizzard, and gizzard digesta content were lower (P < 0.05 to P < 0.001) and gizzard pH was higher (P < 0.05 to P < 0.001) in pullets fed crumbles than in pullets fed mash. Energy concentration of the diet did not affect any of the GIT variables studied. In summary, feeding crumbles improved pullet performance and reduced the RW of the GIT and gizzard, and increased gizzard pH at all ages. An increase in the energy content of the diet improved FCR from 0 to 17 wk of age. The use of crumbles and the increase in the AMEn content of the diet might be used adventageously when the objetive is to increase the BW of the pullets. However, crumbles affected the development and weight of the organs of the GIT, which might have negative effects on feed intake and egg production at the beginning of the egg laying cycle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El cambio climático y sus efectos requieren con urgencia el desarrollo de estrategias capaces no solo de mitigar pero también permitir la adaptación de los sistemas afectados por este fenómeno a los cambios que están provocando a nivel mundial. Olas de calor más largas y frecuentes, inundaciones, y graves sequías aumentan la vulnerabilidad de la población, especialmente en asentamientos urbanos. Este fenómeno y sus soluciones potenciales han sido ampliamente estudiados en las últimas décadas desde diferentes perspectivas y escalas que analizan desde el fenómeno regional de isla de calor al aumento de la intensidad energética necesaria en los edificios para mantener las condiciones de confort en los escenarios de calentamiento que se predicen. Su comprensión requiere el entendimiento de este fenómeno y un profundo análisis de las estrategias que pueden corregirlo y adaptarse a él. En la búsqueda de soluciones a este problema, las estrategias que incorporan sistemas naturales tales como las cubiertas ajardinadas, las fachadas vegetadas y bosques urbanos, se presentan como opciones de diseño capaces de proporcionan múltiples servicios al ecosistema urbano y de regular y hacer frente a los efectos del cambio climático. Entre los servicios que aportan estos sistemas naturales se incluyen la gestión de agua de tormentas, el control del efecto isla de calor, la mejora de la calidad del aire y del agua, el aumento de la diversidad, y como consecuencia de todo lo anterior, la reducción de la huella ecológica de las ciudades. En la última década, se han desarrollado múltiples estudios para evaluar y cuantificar los servicios al ecosistema proporcionados por las infraestructuras verdes, y específicamente las cubiertas ajardinadas, sin embargo, determinados servicios como la capacidad de la regulación del microclima urbano no ha sido apenas estudiados. La mayor parte de la literatura en este campo la componen estudios relacionados con la capacidad de las cubiertas ajardinadas de reducir el efecto de la isla de calor, en una escala local, o acerca de la reducción de la demanda energética de refrigeración debida a la instalación de cubiertas ajardinadas en la escala de edificio. La escala intermedia entre estos dos ámbitos, la calle, desde su ámbito habitable cercano al suelo hasta el límite superior del cañón urbano que configura, no han sido objeto detallado de estudio por lo que es esta escala el objeto de esta tesis doctoral. Esta investigación tiene como objeto contribuir en este campo y aportar un mayor entendimiento a través de la cuantificación del impacto de las cubiertas ajardinadas sobre la temperatura y humedad en el cañón urbano en la escala de calle y con un especial foco en el nivel peatonal. El primer paso de esta investigación ha sido la definición del objeto de estudio a través del análisis y revisión de trabajos tanto teóricos como empíricos que investigan los efectos de cubiertas ajardinadas en el entorno construido, entendidas como una herramienta para la adaptación y mitigación del impacto del cambio climático en las ciudades. La literatura analizada, revela el gran potencial de los sistemas vegetales como herramientas para el diseño pasivo puesto que no solo son capaces de mejorar las condiciones climáticas y microclimaticas en las ciudades reduciendo su demanda energética, sino también la necesidad de mayor análisis en la escala de calle donde confluyen el clima, las superficies urbanas y materiales y vegetación. Este análisis requiere una metodología donde se integren la respuesta térmica de edificios, las variaciones en los patrones de viento y radiación, y la interacción con la vegetación, por lo que un análisis cuantitativo puede ayudar a definir las estrategias más efectivas para lograr espacios urbanos más habitables. En este contexto, el objetivo principal de esta investigación ha sido la evaluación cuantitativa del impacto de la cubierta ajardinada en el microclima urbano a escala de barrio en condiciones de verano en los climas mediterráneos continentales. Para el logro de este objetivo, se ha seguido un proceso que persigue identificar los modelos y herramientas de cálculo capaces de capturar el efecto de la cubierta ajardinada sobre el microclima, identificar los parámetros que potencian o limitan este efecto, y cuantificar las variaciones que microclima creado en el cañón urbano produce en el consumo de energía de los edificios que rodean éste espacio. La hipótesis principal detrás de esta investigación y donde los objetivos anteriores se basan es el siguiente: "una cubierta ajardinada instalada en edificios de mediana altura favorece el establecimiento de microclimas a nivel peatonal y reduce las temperaturas en el entorno urbano donde se encuentra”. Con el fin de verificar la hipótesis anterior y alcanzar los objetivos propuestos se ha seguido la siguiente metodología: • definición del alcance y limitaciones del análisis • Selección de las herramientas y modelos de análisis • análisis teórico de los parámetros que afectan el efecto de las cubiertas ajardinadas • análisis experimental; • modelización energética • conclusiones y futuras líneas de trabajo Dada la complejidad de los fenómenos que intervienen en la generación de unas determinadas condiciones microclimáticas, se ha limitado el objeto de este estudio a las variables de temperatura y humedad, y sólo se han tenido en cuenta los componentes bióticos y abióticos del sistema, que incluyen la morfología, características superficiales del entorno estudiado, así como los elementos vegetales. Los componentes antrópicos no se han incluido en este análisis. La búsqueda de herramientas adecuadas para cumplir con los objetivos de este análisis ha concluido en la selección de ENVI-met v4 como el software más adecuado para esta investigación por su capacidad para representar los complejos fenómenos que caracterizan el microclima en cañones urbanos, en una escala temporal diaria y con unas escala local de vecindario. Esta herramienta supera el desafío que plantean los requisitos informáticos de un cálculo completo basado en elementos finitos realizados a través de herramientas de dinámica de fluidos computacional (CFD) que requieren una capacidad de cálculo computacional y tiempo privativos y en una escala dimensional y temporal limitada a esta capacidad computacional lo que no responde a los objetivos de esta investigación. ENVI-met 4 se basa es un modelo tridimensional del micro clima diseñado para simular las interacciones superficie-planta-aire en entornos urbanos. Basado en las ecuaciones fundamentales del equilibrio que representan, la conservación de masa, energía y momento. ENVI-met es un software predictivo, y como primer paso ha requerido la definición de las condiciones iniciales de contorno que se utilizan como punto de partida por el software para generar su propio perfil de temperatura y humedad diaria basada en la localización de la construcción, geometría, vegetación y las superficies de características físicas del entorno. La geometría de base utilizada para este primer análisis se ha basado en una estructura típica en cuanto al trazado urbano situada en Madrid que se ha simulado con una cubierta tradicional y una cubierta ajardinada en sus edificios. La estructura urbana seleccionada para este análisis comparativo es una red ortogonal con las calles principales orientadas este-oeste. El edificio típico que compone el vecindario se ha definido como “business as usual” (BAU) y se ha definido con una cubierta de baldosa de hormigón estándar, con un albedo 0.3, paredes con albedo 0.2 (construcción de muro de ladrillo típico) y cerramientos adiabáticos para evitar las posibles interferencias causadas por el intercambio térmico con el ambiente interior del edificio en los resultados del análisis. Para el caso de la cubierta ajardinada, se mantiene la misma geometría y características del edificio con excepción de la cobertura superficial de la azotea. Las baldosas de hormigón se han modificado con una cubierta ajardinada extensiva cubierta con plantas xerófilas, típicas en el clima de Madrid y caracterizado por su índice de densidad foliar, el “leaf area density” (LAD), que es la superficie total de superficie de hojas por unidad de volumen (m2/m3). El análisis se centra en los cañones urbanos entendidos como el espacio de calle comprendido entre los límites geométricos de la calle, verticales y horizontales, y el nivel superior de la cota urbana nivel de cubiertas. Los escenarios analizados se basan en la variación de la los principales parámetros que según la literatura analizada condicionan las variaciones microclimáticas en el ámbito urbano afectado por la vegetación, la velocidad del viento y el LAD de la azotea. Los resultados han sido registrados bajo condiciones de exposición solar diferentes. Las simulaciones fueron realizadas por los patrones de viento típico de verano, que para Madrid se caracterizan por vientos de componente suroeste que van desde 3 a 0 m/s. las simulaciones fueron realizadas para unas condiciones climáticas de referencia de 3, 2, 1 y 0 m/s a nivel superior del cañón urbano, como condición de contorno para el análisis. Los resultados calculados a 1,4 metros por encima del nivel del suelo, en el espacio habitado, mostraron que el efecto de la cubierta ajardinada era menor en condiciones de contorno con velocidades de viento más altas aunque en ningún caso el efecto de la cubierta verde sobre la temperatura del aire superó reducciones de temperatura de aire superiores a 1 º C. La humedad relativa no presentó variaciones significativas al comparar los diferentes escenarios. Las simulaciones realizadas para vientos con velocidad baja, entre 0 y 1 m/s mostraron que por debajo de 0.5 m/s la turbulencia del modelo aumentó drásticamente y se convirtió en el modelo inestable e incapaz de producir resultados fiables. Esto es debido al modelo de turbulencia en el software que no es válido para velocidades de viento bajas, lo que limita la capacidad de ENVI-met 4 para realizar simulaciones en estas condiciones de viento y es una de las principales conclusiones de este análisis en cuanto a la herramienta de simulación. También se comprobó el efecto de las densidades de la densidad de hoja (LAD) de los componentes vegetales en el modelo en la capa de aire inmediatamente superior a la cubierta, a 0,5 m sobre este nivel. Se compararon tres alternativas de densidad de hoja con la cubierta de baldosa de hormigón: el techo verde con LAD 0.3 (hierba típica o sedum), LAD 1.5 (plantas mixtas típicas) y LAD 2.5 (masa del árbol). Los resultados mostraron diferencias de temperatura muy relevante entre las diferentes alternativas de LAD analizadas. Los resultados muestran variaciones de temperatura que oscilan entre 3 y 5 º C al comparar el estándar de la azotea concreta con albedo 0, 3 con el techo con vegetación y vegetación densa, mostrando la importancia del LAD en la cuantificación de los efectos de las cubiertas vegetales en microclima circundante, lo que coincide con los datos reportados en la literatura existente y con los estudios empíricos analizados. Los resultados de los análisis teóricos han llegado a las siguientes conclusiones iniciales relacionadas con la herramienta de simulación y los resultados del modelo: En relación con la herramienta ENVI-met, se han observado limitaciones para el análisis. En primer lugar, la estructura rígida de la geometría, las bases de datos y el tamaño de la cuadrícula, limitan la escala y resolución de los análisis no permitiendo el desarrollo de grandes zonas urbanas. Por otro lado la estructura de ENVI-met permite el desarrollo de este tipo de simulación tan complejo dentro de tiempos razonables de cálculo y requerimientos computacionales convencionales. Otra limitación es el modelo de turbulencia del software, que no modela correctamente velocidades de viento bajas (entre 0 y 1 m/s), por debajo de 0,5 m/s el modelo da errores y no es estable, los resultados a estas velocidades no son fiables porque las turbulencias generadas por el modelo hacen imposible la extracción de patrones claros de viento y temperatura que permitan la comparación entre los escenarios de cubierta de hormigón y ajardinada. Además de las limitaciones anteriores, las bases de datos y parámetros de entrada en la versión pública del software están limitados y la complejidad de generar nuevos sistemas adaptándolos al edificio o modelo urbano que se quiera reproducir no es factible salvo en la versión profesional del software. Aparte de las limitaciones anteriores, los patrones de viento y perfiles de temperatura generados por ENVI-met concuerdan con análisis previos en los que se identificaban patrones de variación de viento y temperaturas en cañones urbanos con patrones de viento, relación de aspecto y dimensiones similares a los analizados en esta investigación. Por lo tanto, el software ha demostrado una buena capacidad para reproducir los patrones de viento en los cañones de la calle y capturar el efecto de enfriamiento producido por la cubierta verde en el cañón. En relación con el modelo, el resultado revela la influencia del viento, la radiación y el LAD en la temperatura del aire en cañones urbanos con relación de aspecto comprendida entre 0,5 y 1. Siendo el efecto de la cubierta verde más notable en cañones urbanos sombreados con relación de aspecto 1 y velocidades de viento en el nivel de “canopy” (por encima de la cubierta) de 1 m/s. En ningún caso las reducciones en la temperatura del aire excedieron 1 º C, y las variaciones en la humedad relativa no excedieron 1% entre los escenarios estudiados. Una vez que se han identificado los parámetros relevantes, que fueron principalmente la velocidad del viento y el LAD, se realizó un análisis experimental para comprobar los resultados obtenidos por el modelo. Para éste propósito se identificó una cubierta ajardinada de grandes dimensiones capaz de representar la escala urbana que es el objeto del estudio. El edificio usado para este fin fue el parking de la terminal 4 del aeropuerto internacional de Madrid. Aunque esto no es un área urbana estándar, la escala y la configuración del espacio alrededor del edificio fueron considerados aceptables para el análisis por su similitud con el contexto urbano objeto de estudio. El edificio tiene 800 x 200 m, y una altura 15 m. Está rodeado de vías de acceso pavimentadas con aceras conformando un cañón urbano limitado por el edificio del parking, la calle y el edificio de la terminal T4. El aparcamiento está cerrado con fachadas que configuran un espacio urbano de tipo cañón, con una relación de aspecto menor que 0,5. Esta geometría presenta patrones de viento y velocidad dentro del cañón que difieren ligeramente de los generados en el estudio teórico y se acercan más a los valores a nivel de canopo sobre la cubierta del edificio, pero que no han afectado a la tendencia general de los resultados obtenidos. El edificio cuenta con la cubierta ajardinada más grande en Europa, 12 Ha cubiertas por con una mezcla de hierbas y sedum y con un valor estimado de LAD de 1,5. Los edificios están rodeados por áreas plantadas en las aceras y árboles de sombra en las fachadas del edificio principal. El efecto de la cubierta ajardinada se evaluó mediante el control de temperaturas y humedad relativa en el cañón en un día típico de verano. La selección del día se hizo teniendo en cuenta las predicciones meteorológicas para que fuesen lo más semejantes a las condiciones óptimas para capturar el efecto de la cubierta vegetal sobre el microclima urbano identificadas en el modelo teórico. El 09 de julio de 2014 fue seleccionado para la campaña de medición porque las predicciones mostraban 1 m/s velocidad del viento y cielos despejados, condiciones muy similares a las condiciones climáticas bajo las que el efecto de la cubierta ajardinada era más notorio en el modelo teórico. Las mediciones se registraron cada hora entre las 9:00 y las 19:00 en 09 de julio de 2014. Temperatura, humedad relativa y velocidad del viento se registraron en 5 niveles diferentes, a 1.5, 4.5, 7.5, 11.5 y 16 m por encima del suelo y a 0,5 m de distancia de la fachada del edificio. Las mediciones fueron tomadas en tres escenarios diferentes, con exposición soleada, exposición la sombra y exposición influenciada por los árboles cercanos y suelo húmedo. Temperatura, humedad relativa y velocidad del viento se registraron con un equipo TESTO 410-2 con una resolución de 0,1 ºC para temperatura, 0,1 m/s en la velocidad del viento y el 0,1% de humedad relativa. Se registraron las temperaturas de la superficie de los edificios circundantes para evaluar su efecto sobre los registros usando una cámara infrarroja FLIR E4, con resolución de temperatura 0,15ºC. Distancia mínima a la superficie de 0,5 m y rango de las mediciones de Tª de - 20 º C y 250 º C. Los perfiles de temperatura extraídos de la medición in situ mostraron la influencia de la exposición solar en las variaciones de temperatura a lo largo del día, así como la influencia del calor irradiado por las superficies que habían sido expuestas a la radiación solar así como la influencia de las áreas de jardín alrededor del edificio. Después de que las medidas fueran tomadas, se llevaron a cabo las siguientes simulaciones para evaluar el impacto de la cubierta ajardinada en el microclima: a. estándar de la azotea: edificio T4 asumiendo un techo de tejas de hormigón con albedo 0.3. b. b. cubierta vegetal : T4 edificio asumiendo una extensa cubierta verde con valor bajo del LAD (0.5)-techo de sedum simple. c. c. cubierta vegetal: T4 edificio asumiendo una extensa cubierta verde con alta joven valor 1.5-mezcla de plantas d. d. cubierta ajardinada más vegetación nivel calle: el edificio T4 con LAD 1.5, incluyendo los árboles existentes a nivel de calle. Este escenario representa las condiciones actuales del edificio medido. El viento de referencia a nivel de cubierta se fijó en 1 m/s, coincidente con el registro de velocidad de viento en ese nivel durante la campaña de medición. Esta velocidad del viento se mantuvo constante durante toda la campaña. Bajo las condiciones anteriores, los resultados de los modelos muestran un efecto moderado de azoteas verdes en el microclima circundante que van desde 1 º a 2 º C, pero una contribución mayor cuando se combina con vegetación a nivel peatonal. En este caso las reducciones de temperatura alcanzan hasta 4 ºC. La humedad relativa sin embargo, no presenta apenas variación entre los escenarios con y sin cubierta ajardinada. Las temperaturas medidas in situ se compararon con resultados del modelo, mostrando una gran similitud en los perfiles definidos en ambos casos. Esto demuestra la buena capacidad de ENVI-met para reproducir el efecto de la cubierta ajardinada sobre el microclima y por tanto para el fin de esta investigación. Las diferencias más grandes se registraron en las áreas cercanas a las zonas superiores de las fachadas que estaban más expuestas a la radiación del sol y también el nivel del suelo, por la influencia de los pavimentos. Estas diferencias se pudieron causar por las características de los cerramientos en el modelo que estaban limitados por los datos disponibles en la base de datos de software, y que se diferencian con los del edificio real. Una observación importante derivada de este estudio es la contribución del suelo húmedo en el efecto de la cubierta ajardinada en la temperatura del aire. En el escenario de la cubierta ajardinada con los arboles existentes a pie de calle, el efecto del suelo húmedo contribuye a aumentar las reducciones de temperatura hasta 4.5ºC, potenciando el efecto combinado de la cubierta ajardinada y la vegetación a pie de calle. Se realizó un análisis final después de extraer el perfil horario de temperaturas en el cañón urbano influenciado por el efecto de las cubiertas ajardinadas y los árboles. Con esos perfiles modificados de temperatura y humedad se desarrolló un modelo energético en el edificio asumiendo un edificio cerrado y climatizado, con uso de oficinas, una temperatura de consigna de acuerdo al RITE de 26 ºC, y con los sistemas por defecto que establece el software para el cálculo de la demanda energética y que responden a ASHRAE 90.1. El software seleccionado para la simulación fue Design Builder, por su capacidad para generar simulaciones horarias y por ser una de las herramientas de simulación energética más reconocidas en el mercado. Los perfiles modificados de temperatura y humedad se insertaron en el año climático tipo y se condujo la simulación horaria para el día definido, el 9 de Julio. Para la simulación se dejaron por defecto los valores de conductancia térmica de los cerramientos y la eficiencia de los equipos de acuerdo a los valores que fija el estándar ASHRAE para la zona climática de Madrid, que es la 4. El resultado mostraba reducciones en el consumo de un día pico de hasta un 14% de reducción en las horas punta. La principal conclusión de éste estudio es la confirmación del potencial de las cubiertas ajardinadas como una estrategia para reducir la temperatura del aire y consumo de energía en los edificios, aunque este efecto puede ser limitado por la influencia de los vientos, la radiación y la especie seleccionada para el ajardinamiento, en especial de su LAD. Así mismo, en combinación con los bosques urbanos su efecto se potencia e incluso más si hay pavimentos húmedos o suelos porosos incluidos en la morfología del cañón urbano, convirtiéndose en una estrategia potencial para adaptar los ecosistemas urbanos el efecto aumento de temperatura derivado del cambio climático. En cuanto a la herramienta, ENVI-met se considera una buena opción para éste tipo de análisis dada su capacidad para reproducir de un modo muy cercano a la realidad el efecto de las cubiertas. Aparte de ser una herramienta validada en estudios anteriores, en el caso experimental se ha comprobado por medio de la comparación de las mediciones con los resultados del modelo. A su vez, los resultados y patrones de vientos generados en los cañones urbanos coinciden con otros estudios similares, concluyendo por tanto que es un software adecuado para el objeto de esta tesis doctoral. Como líneas de investigación futura, sería necesario entender el efecto de la cubierta ajardinada en el microclima urbano en diferentes zonas climáticas, así como un mayor estudio de otras variables que no se han observado en este análisis, como la temperatura media radiante y los indicadores de confort. Así mismo, la evaluación de otros parámetros que afectan el microclima urbano tales como variables geométricas y propiedades superficiales debería ser analizada en profundidad para tener un resultado que cubra todas las variables que afectan el microclima en el cañón urbano. ABSTRACT Climate Change is posing an urgency in the development of strategies able not only to mitigate but also adapt to the effects that this global problem is evidencing around the world. Heat waves, flooding and severe draughts increase the vulnerability of population, and this is especially critical in urban settlements. This has been extensively studied over the past decades, addressed from different perspectives and ranging from the regional heat island analysis to the building scale. Its understanding requires physical and dimensional analysis of this broad phenomenon and a deep analysis of the factors and the strategies which can offset it. In the search of solutions to this problem, green infrastructure elements such as green roofs, walls and urban forests arise as strategies able provide multiple regulating ecosystem services to the urban environment able to cope with climate change effects. This includes storm water management, heat island effect control, and improvement of air and water quality. Over the last decade, multiple studies have been developed to evaluate and quantify the ecosystem services provided by green roofs, however, specific regulating services addressing urban microclimate and their impact on the urban dwellers have not been widely quantified. This research tries to contribute to fill this gap and analyzes the effects of green roofs and urban forests on urban microclimate at pedestrian level, quantifying its potential for regulating ambient temperature in hot season in Mediterranean –continental climates. The study is divided into a sequence of analysis where the critical factors affecting the performance of the green roof system on the microclimate are identified and the effects of the green roof is tested in a real case study. The first step has been the definition of the object of study, through the analysis and review of theoretical and empirical papers that investigate the effects of covers landscaped in the built environment, in the context of its use as a tool for adaptation and mitigation of the impact of climate change on cities and urban development. This literature review, reveals the great potential of the plant systems as a tool for passive design capable of improving the climatic and microclimatic conditions in the cities, as well as its positive impact on the energy performance of buildings, but also the need for further analysis at the street scale where climate, urban surfaces and materials, and vegetation converge. This analysis requires a methodology where the thermal buildings response, the variations in the patterns of wind and the interaction of the vegetation are integrated, so a quantitative analysis can help to define the most effective strategies to achieve liveable urban spaces and collaterally, , the improvement of the surrounding buildings energy performance. In this specific scale research is needed and should be customized to every climate, urban condition and nature based strategy. In this context, the main objective for this research was the quantitative assessment of the Green roof impact on the urban microclimate at a neighbourhood scale in summer conditions in Mediterranean- continental climates. For the achievement of this main objective, the following secondary objectives have been set: • Identify the numerical models and calculation tools able to capture the effect of the roof garden on the microclimate. • Identify the enhancing or limiting parameter affecting this effect. • Quantification of the impact of the microclimate created on the energy consumption of buildings surrounding the street canyon analysed. The main hypothesis behind this research and where the above objectives are funded on is as follows: "An extensive roof installed in medium height buildings favours the establishment of microclimates at the pedestrian level and reduces the temperatures in the urban environment where they are located." For the purpose of verifying the above hypothesis and achieving the proposed objectives the following methodology has been followed: - Definition of hypothesis and objectives - Definition of the scope and limitations - Theoretical analysis of parameters affecting gren roof performance - Experimental analysis; - Energy modelling analyisis - Conclusions and future lines of work The search for suitable tools and models for meeting the objectives of this analysis has led to ENVI-met v4 as the most suitable software for this research. ENVI met is a three-dimensional micro-climate model designed to simulate the surface-plant-air interactions in urban environments. Based in the fundamental equations representing, mass, energy and momentum conservation, the software has the capacity of representing the complex phenomena characterizing the microclimate in urban canyons, overcoming the challenge posed by the computing requirements of a full calculus based on finite elements done via traditional computational fluid dynamics tools. Once the analysis tool has been defined, a first set of analysis has been developed to identify the main parameters affecting the green roof influence on the microclimate. In this analysis, two different scenarios are compared. A neighborhood with standard concrete tile roof and the same configuration substituting the concrete tile by an extensive green roof. Once the scenarios have been modeled, different iterations have been run to identify the influence of different wind patterns, solar exposure and roof vegetation type on the microclimate, since those are the most relevant variables affecting urban microclimates. These analysis have been run to check the conditions under which the effects of green roofs get significance. Since ENVI-met V4 is a predictive software, the first step has been the definition of the initial weather conditions which are then used as starting point by the software, which generates its own daily temperature and humidity profile based on the location of the building, geometry, vegetation and the surfaces physical characteristics. The base geometry used for this first analysis has been based on a typical urban layout structure located in Madrid, an orthogonal net with the main streets oriented East-West to ease the analysis of solar radiation in the different points of the model. This layout represents a typical urban neighborhood, with street canyons keeping an aspect ratio between 0.5 and 1 and high sky view factor to ensure correct sun access to the streets and buildings and work with typical wind flow patterns. Finally, the roof vegetation has been defined in terms of foliage density known as Leaf Area Density (LAD) and defined as the total one-sided leaf area per unit of layer volume. This index is the most relevant vegetation characteristic for the purpose of calculating the effect of vegetation on wind and solar radiation as well as the energy consumed during its metabolic processes. The building as usual (BAU) configuring the urban layout has been defined with standard concrete tile roofs, considering 0.3 albedo. Walls have been set with albedo 0.2 (typical brick wall construction) and adiabatic to avoid interference caused by thermal interchanges with the building indoor environment. For the proposed case, the same geometry and building characteristics have been kept. The only change is the roof surface coverage. The gravel on the roof has been changed with an extensive green roof covered with drought tolerant plants, typical in Madrid climate, and characterized by their LAD. The different scenarios analysed are based in the variation of the wind speed and the LAD of the roof. The results have been recorded under different sun exposure conditions. Simulations were run for the typical summer wind patterns, that for Madrid are characterized by South-west winds ranging from 3 to 0 m/s. Simulations were run for 3, 2, 1 and 0 m/s at urban canopy level. Results taken at 1.4 m above the ground showed that the green roof effect was lower with higher wind speeds and in any case the effect of the green roof on the air temperatures exceeded air temperature reductions higher than 1ºC. Relative humidity presented no variations when comparing the different scenarios. For the analysis at 0m/s, ENVI-met generated error and no results were obtained. Different simulations showed that under 0.5 m/s turbulence increased dramatically and the model became unstable and unable to produce reliable results. This is due to the turbulence model embedded in the software which is not valid for low wind speeds (below 1 m/s). The effect of the different foliage densities was also tested in the model. Three different alternatives were compared against the concrete roof: green roof with LAD 0.3 ( typical grass or sedum), 1.5 (typical mixed plants) and 2.5 (tree mass). The results showed very relevant temperature differences between the different LAD alternatives analyzed. Results show temperature variations ranging between 3 and 5 ºC when comparing the standard concrete roof with albedo 0, 3 with the vegetated roof and vegetated mass, showing the relevance of the LAD on the effects of green roofs on microclimate. This matches the data reported in existing literature and empirical studies and confirms the relevance of the LAD in the roof effect on the surrounding microclimate. The results of the theoretical analysis have reached the following initial conclusions related to both, the simulation tool and the model results: • In relation to the tool ENVI-met, some limitations for the analysis have been observed. In first place, the rigid structure of the geometry, the data bases and the grid size, limit the scale and resolution of the analysis not allowing the development of large urban areas. On the other hand the ENVI-met structure enables the development of this type of complex simulation within reasonable times and computational requirements for the purpose of this analysis. Additionally, the model is unable to run simulations at wind speeds lower than 0.5 m/s, and even at this speed, the results are not reliable because the turbulences generated by the model that made impossible to extract clear temperature differences between the concrete and green roof scenarios. Besides the above limitations, the wind patterns and temperature profiles generated by ENVImet are in agreement with previous analysis identifying wind patterns in urban canyons with similar characteristics and aspect ratio. Therefore the software has shown a good capacity for reproducing the wind effects in the street canyons and seems to capture the cooling effect produced by the green roof. • In relation to the model, the results reveals the influence of wind, radiation and LAD on air temperature in urban canyons with aspect ratio comprised between 0.5 and 1. Being the effect of the green roof more noticeable in shaded urban canyons with aspect ratio 1 and wind speeds of 1 m/s. In no case the reductions in air temperature exceeded 1ºC. Once the relevant parameters have been identified, mainly wind speed and LAD, an experimental analysis was conducted to test the results obtained by the model. For this purpose a large green roof was identified, able to represent the urban scale which is the object of the studio. The building identified for this purpose was the terminal 4, parking building of the international Madrid Airport. Even though this is not a standard urban area, the scale and configuration of the space around the building were deemed as acceptable for the analysis. The building is an 800x200 m, 15 m height parking building, surrounded by access paved paths and the terminal building. The parking is enclosed with facades that configure an urban canyon-like space, although the aspect ratio is lower than 0.5 and the wind patterns might differ from the theoretical model run. The building features the largest green roof in Europe, a 12 Ha extensive green roof populated with a mix of herbs and sedum with a LAD of 1.5. The buildings are surrounded by planted areas at the sidewalk and trees shading the main building facades. Green roof performance was evaluated by monitoring temperatures and relative humidity in the canyon in a typical summer day. The day selection was done taking into account meteorological predictions so the weather conditions on the measurement day were as close as possible as the optimal conditions identified in terms of green roof effects on the urban canyon. July 9th 2014 was selected for the measurement campaign because the predictions showed 1 m/s wind speed and sunny sky, which were very similar to the weather conditions where the effect of the green roof was most noticeable in the theory model. Measurements were registered hourly from 9:00am to 19:00 on July 9th 2014. Temperature, relative humidity and wind speed were recorded at 5 different levels, at 1.5, 4.5, 7.5, 11.5 and 16 m above ground and at 0.5 m distance from the building façade. Measurements were taken in three different scenarios, sunny exposure, shaded exposure, and shaded exposure influenced by nearby trees and moist soil. Temperature, relative humidity and wind speed were registered using a TESTO 410-2 anemometer, with 0.1ºC resolution for temperature, 0.1 m/s resolution for wind speed and 0.1 % for relative humidity. Surface temperatures were registered using an infrared camera FLIR E4, with temperature resolution 0.15ºC. Minimal distance to surface of 0.5 m and Tª measurements range from -20ºC and 250ºC. The temperature profiles measured on the site showed the influence of solar exposure on the temperature variations along the day, as well as the influence of the heat irradiated by the building surfaces which had been exposed to the sun radiation and those influenced by the moist soft areas around the building. After the measurements were taken, the following simulations were conducted to evaluate the impact of the green roof on the microclimate: a. Standard roof: T4 building assuming a concrete tile roof with albedo 0.3. b. Green roof: T4 building assuming an extensive green roof with low LAD value (0.5)-Simple Sedum roof. c. Green roof: T4 building assuming an extensive green roof with high LAD value 1.5- Lucerne and grasses d. Green roof plus street level vegetation: T4 Building, LAD 1.5 (Lucerne), including the existing trees at street level. This scenario represents the current conditions of the building. The urban canopy wind was set as 1 m/s, the wind speed register at that level during the measurement campaign. This wind speed remained constant over the whole campaign. Under the above conditions, the results of the models show a moderate effect of green roofs on the surrounding microclimate ranging from 1ºC to 2ºC, but a larger contribution when combining it with vegetation at pedestrian level, where 4ºC temperature reductions are reached. Relative humidity remained constant. Measured temperatures and relative humidity were compared to model results, showing a close match in the profiles defined in both cases and the good capacity of ENVI met to capture the impact of the green roof in this analysis. The largest differences were registered in the areas close to the top areas of the facades which were more exposed to sun radiation and also near to the soil level. These differences might be caused by differences between the materials properties included in the model (which were limited by the data available in the software database) and those in the real building. An important observation derived from this study is the contribution of moist soil to the green roof effect on air temperatures. In the green roof scenario with surrounding trees, the effect of the moist soil contributes to raise the temperature reductions at 4.5ºC. A final analysis was conducted after extracting the hourly temperature profile in the street canyon influenced by the effect of green roofs and trees. An energy model was run on the building assuming it was a conventional enclosed building. Energy demand reductions were registered in the building reaching up to 14% reductions at the peak hour. The main conclusion of this study is the potential of the green roofs as a strategy for reducing air temperatures and energy consumption in the buildings, although this effect can be limited by the influence of high speed winds. This effect can be enhanced its combination with urban forests and even more if soft moist pavements are included in the urban canyon morphology, becoming a potential strategy for adapting urban ecosystems to the increasing temperature effect derived from climate change.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La presente Tesis Doctoral evalúa la contribución de una fachada activa, constituida por acristalamientos con circulación de agua, en el rendimiento energético del edificio. Con especial énfasis en la baja afección sobre su imagen, su integración ha de favorecer la calificación del edificio con el futuro estándar de Edificio de consumo de Energía Casi Nulo (EECN). El propósito consiste en cuantificar su aportación a limitar la demanda de climatización, como solución de fachada transparente acorde a las normas de la energía del 2020. En el primer capítulo se introduce el planteamiento del problema. En el segundo capítulo se desarrollan la hipótesis y el objetivo fundamental de la investigación. Para tal fin, en el tercer capítulo, se revisa el estado del arte de la tecnología y de la investigación científica, mediante el análisis de la literatura de referencia. Se comparan patentes, prototipos, sistemas comerciales asimilables, investigaciones en curso en Universidades, y proyectos de investigación y desarrollo, sobre envolventes que incorporan acristalamientos con circulación de agua. El método experimental, expuesto en el cuarto capítulo, acomete el diseño, la fabricación y la monitorización de un prototipo expuesto, durante ciclos de ensayos, a las condiciones climáticas de Madrid. Esta fase ha permitido adquirir información precisa sobre el rendimiento del acristalamiento en cada orientación de incidencia solar, en las distintas estaciones del año. En paralelo, se aborda el desarrollo de modelos teóricos que, mediante su asimilación a soluciones multicapa caracterizadas en las herramientas de simulación EnergyPlus y IDA-ICE (IDA Indoor Climate and Energy), reproducen el efecto experimental. En el quinto capítulo se discuten los resultados experimentales y teóricos, y se analiza la respuesta del acristalamiento asociado a un determinado volumen y temperatura del agua. Se calcula la eficiencia en la captación de la radiación y, mediante la comparativa con un acristalamiento convencional, se determina la reducción de las ganancias solares y las pérdidas de energía. Se comparan el rendimiento del acristalamiento, obtenido experimentalmente, con el ofrecido por paneles solares fototérmicos disponibles en el mercado. Mediante la traslación de los resultados experimentales a casos de células de tamaño habitable, se cuantifica la afección del acristalamiento sobre el consumo en refrigeración y calefacción. Diferenciando cada caso por su composición constructiva y orientación, se extraen conclusiones sobre la reducción del gasto en climatización, en condiciones de bienestar. Posteriormente, se evalúa el ahorro de su incorporación en un recinto existente, de construcción ligera, localizado en la Escuela de Arquitectura de la Universidad Politécnica de Madrid (UPM). Mediante el planteamiento de escenarios de rehabilitación energética, se estima su compatibilidad con un sistema de climatización mediante bomba de calor y extracción geotérmica. Se describe el funcionamiento del sistema, desde la perspectiva de la operación conjunta de los acristalamientos activos e intercambio geotérmico, en nuestro clima. Mediante la parametrización de sus funciones, se estima el beneficio adicional de su integración, a partir de la mejora del rendimiento de la bomba de calor COP (Coefficient of Performance) en calefacción, y de la eficiencia EER (Energy Efficiency Ratio) en refrigeración. En el recinto de la ETSAM, se ha analizado la contribución de la fachada activa en su calificación como Edificio de Energía Casi Nula, y estudiado la rentabilidad económica del sistema. En el sexto capítulo se exponen las conclusiones de la investigación. A la fecha, el sistema supone alta inversión inicial, no obstante, genera elevada eficiencia con bajo impacto arquitectónico, reduciéndose los costes operativos, y el dimensionado de los sistemas de producción, de mayor afección sobre el edificio. Mediante la envolvente activa con suministro geotérmico no se condena la superficie de cubierta, no se ocupa volumen útil por la presencia de equipos emisores, y no se reduce la superficie o altura útil a base de reforzar los aislamientos. Tras su discusión, se considera una alternativa de valor en procesos de diseño y construcción de Edificios de Energía Casi Nulo. Se proponen líneas de futuras investigación cuyo propósito sea el conocimiento de la tecnología de los acristalamientos activos. En el último capítulo se presentan las actividades de difusión de la investigación. Adicionalmente se ha proporcionado una mejora tecnológica a las fachadas activas existentes, que ha derivado en la solicitud de una patente, actualmente en tramitación. ABSTRACT This Thesis evaluates the contribution of an active water flow glazing façade on the energy performance of buildings. Special emphasis is made on the low visual impact on its image, and the active glazing implementation has to encourage the qualification of the building with the future standard of Nearly Zero Energy Building (nZEB). The purpose is to quantify the façade system contribution to limit air conditioning demand, resulting in a transparent façade solution according to the 2020 energy legislation. An initial approach to the problem is presented in first chapter. The second chapter develops the hypothesis and the main objective of the research. To achieve this purpose, the third chapter reviews the state of the art of the technology and scientific research, through the analysis of reference literature. Patents, prototypes, assimilable commercial systems, ongoing research in other universities, and finally research and development projects incorporating active fluid flow glazing are compared. The experimental method, presented in fourth chapter, undertakes the design, manufacture and monitoring of a water flow glazing prototype exposed during test cycles to weather conditions in Madrid. This phase allowed the acquisition of accurate information on the performance of water flow glazing on each orientation of solar incidence, during different seasons. In parallel, the development of theoretical models is addressed which, through the assimilation to multilayer solutions characterized in the simulation tools EnergyPlus and IDA-Indoor Climate and Energy, reproduce the experimental effect. Fifth chapter discusses experimental and theoretical results focused to the analysis of the active glazing behavior, associated with a specific volume and water flow temperature. The efficiency on harvesting incident solar radiation is calculated, and, by comparison with a conventional glazing, the reduction of solar gains and energy losses are determined. The experimental performance of fluid flow glazing against the one offered by photothermal solar panels available on the market are compared. By translating the experimental and theoretical results to cases of full-size cells, the reduction in cooling and heating consumption achieved by active fluid glazing is quantified. The reduction of energy costs to achieve comfort conditions is calculated, differentiating each case by its whole construction composition and orientation. Subsequently, the saving of the implementation of the system on an existing lightweight construction enclosure, located in the School of Architecture at the Polytechnic University of Madrid (UPM), is then calculated. The compatibility between the active fluid flow glazing and a heat pump with geothermal heat supply system is estimated through the approach of different energy renovation scenarios. The overall system operation is described, from the perspective of active glazing and geothermal heat exchange combined operation, in our climate. By parameterization of its functions, the added benefit of its integration it is discussed, particularly from the improvement of the heat pump performance COP (Coefficient of Performance) in heating and efficiency EER (Energy Efficiency Ratio) in cooling. In the case study of the enclosure in the School of Architecture, the contribution of the active glazing façade in qualifying the enclosure as nearly Zero Energy Building has been analyzed, and the feasibility and profitability of the system are studied. The sixth chapter sets the conclusions of the investigation. To date, the system may require high initial investment; however, high efficiency with low architectural impact is generated. Operational costs are highly reduced as well as the size and complexity of the energy production systems, which normally have huge visual impact on buildings. By the active façade with geothermal supply, the deck area it is not condemned. Useful volume is not consumed by the presence of air-conditioning equipment. Useful surface and room height are not reduced by insulation reinforcement. After discussion, water flow glazing is considered a potential value alternative in nZEB design and construction processes. Finally, this chapter proposes future research lines aiming to increase the knowledge of active water flow glazing technology. The last chapter presents research dissemination activities. Additionally, a technological improvement to existing active facades has been developed, which has resulted in a patent application, currently in handling process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of fiber inclusion, feed form, and energy concentration of the diet on the growth performance of pullets from hatching to 5 wk age were studied in 2 experiments. In Experiment 1, there was a control diet based on cereals and soybean meal, and 6 extra diets that included 2 or 4% of cereal straw, sugar beet pulp (SBP), or sunflower hulls (SFHs) at the expense (wt/wt) of the whole control diet. From hatching to 5 wk age fiber inclusion increased (P < 0.05) ADG and ADFI, and improved (P < 0.05) energy efficiency (EnE; kcal AMEn/g ADG), but body weight (BW) uniformity was not affected. Pullets fed SFH tended to have higher ADG than pullets fed SBP (P = 0.072) with pullets fed straw being intermediate. The feed conversion ratio (FCR) was better (P < 0.05) with 2% than with 4% fiber inclusion. In Experiment 2, 10 diets were arranged as a 2×5 factorial with 2 feed forms (mash vs. crumbles) and 5 levels of AMEn (2,850, 2,900, 2,950, 3,000, and 3,050 kcal/kg). Pullets fed crumbles were heavier and had better FCR than pullets fed mash (P < 0.001). An increase in the energy content of the crumble diets reduced ADFI and improved FCR linearly, but no effects were detected with the mash diets (P < 0.01 and P < 0.05 for the interactions). Feeding crumbles tended to improve BW uniformity at 5 wk age (P = 0.077) but no effects were detected with increases in energy concentration of the diet. In summary, the inclusion of moderate amounts of fiber in the diet improves pullet performance from hatching to 5 wk age. The response of pullets to increases in energy content of the diet depends on feed form with a decrease in feed intake when fed crumbles but no changes when fed mash. Feeding crumbles might be preferred to feeding mash in pullets from hatching to 5 wk age.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The aim of this study is to present face, content, and constructs validity of the endoscopic orthogonal video system (EndoViS) training system and determines its efficiency as a training and objective assessment tool of the surgeons’ psychomotor skills. Methods Thirty-five surgeons and medical students participated in this study: 11 medical students, 19 residents, and 5 experts. All participants performed four basic skill tasks using conventional laparoscopic instruments and EndoViS training system. Subsequently, participants filled out a questionnaire regarding the design, realism, overall functionality, and its capabilities to train hand–eye coordination and depth perception, rated on a 5-point Likert scale. Motion data of the instruments were obtained by means of two webcams built into a laparoscopic physical trainer. To identify the surgical instruments in the images, colored markers were placed in each instrument. Thirteen motion-related metrics were used to assess laparoscopic performance of the participants. Statistical analysis of performance was made between novice, intermediate, and expert groups. Internal consistency of all metrics was analyzed with Cronbach’s α test. Results Overall scores about features of the EndoViS system were positives. Participants agreed with the usefulness of tasks and the training capacities of EndoViS system (score >4). Results presented significant differences in the execution of three skill tasks performed by participants. Seven metrics showed construct validity for assessment of performance with high consistency levels. Conclusions EndoViS training system has been successfully validated. Results showed that EndoViS was able to differentiate between participants of varying laparoscopic experience. This simulator is a useful and effective tool to objectively assess laparoscopic psychomotor skills of the surgeons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sequence divergence acts as a potent barrier to homologous recombination; much of this barrier derives from an antirecombination activity exerted by mismatch repair proteins. An inverted repeat assay system with recombination substrates ranging in identity from 74% to 100% has been used to define the relationship between sequence divergence and the rate of mitotic crossing-over in yeast. To elucidate the role of the mismatch repair machinery in regulating recombination between mismatched substrates, we performed experiments in both wild-type and mismatch repair defective strains. We find that a single mismatch is sufficient to inhibit recombination between otherwise identical sequences, and that this inhibition is dependent on the mismatch repair system. Additional mismatches have a cumulative negative effect on the recombination rate. With sequence divergence of up to approximately 10%, the inhibitory effect of mismatches results mainly from antirecombination activity of the mismatch repair system. With greater levels of divergence, recombination is inefficient even in the absence of mismatch repair activity. In both wild-type and mismatch repair defective strains, an approximate log-linear relationship is observed between the recombination rate and the level of sequence divergence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The multidimensional free energy surface for a small fast folding helical protein is explored based on first-principle calculations. The model represents the 46-residue segment from fragment B of staphylococcal protein A. The relationship between collapse and tertiary structure formation, and the order of collapse and secondary structure formation, are investigated. We find that the initial collapse process gives rise to a transition state with about 30% of the native tertiary structure and 50–70% of the native helix content. We also observe two distinct distributions of native helix in this collapsed state (Rg ≈ 12 Å), one with about 20% of the native helical hydrogen bonds, the other with near 70%. The former corresponds to a local minimum. The barrier from this metastable state to the native state is about 2 kBT. In the latter case, folding is essentially a downhill process involving topological assembly. In addition, the order of formation of secondary structure among the three helices is examined. We observe cooperative formation of the secondary structure in helix I and helix II. Secondary structure in helix III starts to form following the formation of certain secondary structure in both helix I and helix II. Comparisons of our results with those from theory and experiment are made.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The twin-domain model [Liu, L. F. & Wang, J. C. (1987) Proc. Natl. Acad. Sci. USA 84, 7024–7027] suggests that closely spaced, divergent, superhelically sensitive promoters can affect the transcriptional activity of one another by transcriptionally induced negative DNA supercoiling generated in the divergent promoter region. This gene arrangement is observed for many LysR-type-regulated operons in bacteria. We have examined the effects of divergent transcription in the prototypic LysR-type system, the ilvYC operon of Escherichia coli. Double-reporter constructs with the lacZ gene under transcriptional control of the ilvC promoter and the galK gene under control of the divergent ilvY promoter were used to demonstrate that a down-promoter mutation in the ilvY promoter severely decreases in vivo transcription from the ilvC promoter. However, a down-promoter mutation in the ilvC promoter only slightly affects transcription from the ilvY promoter. In vitro transcription assays with DNA topoisomers showed that transcription from the ilvC promoter increases over the entire range of physiological superhelical densities, whereas transcription initiation from the ilvY promoter exhibits a broad optimum at a midphysiological superhelical density. Evidence that this promoter coupling is DNA supercoiling-dependent is provided by the observation that a novobiocin-induced decrease in global negative superhelicity results in an increase in ilvY promoter activity and a decrease in ilvC promoter activity predicted by the in vitro data. We suggest that this transcriptional coupling is important for coordinating basal level expression of the ilvYC operon with the nutritional and environmental conditions of cell growth.