935 resultados para Surgical flaps
Resumo:
Background: Surgical site infections (SSIs) after abdominal surgeries account for approximately 26% of all reported SSIs. The Center for Disease Control and Prevention (CDC) defines 3 types of SSIs: superficial incisional, deep incisional, and organ/space. Preventing SSIs has become a national focus. This dissertation assesses several associations with the individual types of SSI in patients that have undergone colon surgery. ^ Methods: Data for this dissertation was obtained from the American College of Surgeons' National Surgical Quality Improvement Program (NSQIP); major colon surgeries were identified in the database that occurred between the time period of 2007 and 2009. NSQIP data includes more than 50 preoperative and 30 intraoperative factors; 40 collected postoperative occurrences are based on a follow-up period of 30 days from surgery. Initially, four individual logistic regressions were modeled to compare the associations between risk factors and each of the SSI groups: superficial, deep, organ/space and a composite of any single SSI. A second analysis used polytomous regression to assess simultaneously the associations between risk factors and the different types of SSIs, as well as, formally test the different effect estimates of 13 common risk factors for SSIs. The final analysis explored the association between venous thromboembolism (VTEs) and the different types of SSIs and risk factors. ^ Results: A total of 59,365 colon surgeries were included in the study. Overall, 13% of colon cases developed a single type of SSI; 8% of these were superficial SSIs, 1.4% was deep SSIs, and 3.8% were organ/space SSIs. The first article identifies the unique set of risk factors associated with each of the 4 SSI models. Distinct risk factors for superficial SSIs included factors, such as alcohol, chronic obstructive pulmonary disease, dyspnea and diabetes. Organ/space SSIs were uniquely associated with disseminated cancer, preoperative dialysis, preoperative radiation treatment, bleeding disorder and prior surgery. Risk factors that were significant in all models had different effect estimates. The second article assesses 13 common SSI risk factors simultaneously across the 3 different types of SSIs using polytomous regression. Then each risk factor was formally tested for the effect heterogeneity exhibited. If the test was significant the final model would allow for the effect estimations for that risk factor to vary across each type of SSI; if the test was not significant, the effect estimate would remain constant across the types of SSIs using the aggregate SSI value. The third article explored the relationship of venous thromboembolism (VTE) and the individual types of SSIs and risk factors. The overall incidence of VTEs after the 59,365 colon cases was 2.4%. All 3 types of SSIs and several risk factors were independently associated with the development of VTEs. ^ Conclusions: Risk factors associated with each type of SSI were different in patients that have undergone colon surgery. Each model had a unique cluster of risk factors. Several risk factors, including increased BMI, duration of surgery, wound class, and laparoscopic approach, were significant across all 4 models but no statistical inferences can be made about their different effect estimates. These results suggest that aggregating SSIs may misattribute and hide true associations with risk factors. Using polytomous regression to assess multiple risk factors with the multiple types of SSI, this study was able to identify several risk factors that had significant effect heterogeneity across the 3 types of SSI challenging the use of aggregate SSI outcomes. The third article recognizes the strong association between VTEs and the 3 types of SSIs. Clinicians understand the difference between superficial, deep and organ/space SSIs. Our results indicate that they should be considered individually in future studies.^
Resumo:
The present work covers the first validation efforts of the EVA Tracking System for the assessment of minimally invasive surgery (MIS) psychomotor skills. Instrument movements were recorded for 42 surgeons (4 expert, 22 residents, 16 novice medical students) and analyzed for a box trainer peg transfer task. Construct validation was established for 7/9 motion analysis parameters (MAPs). Concurrent validation was determined for 8/9 MAPs against the TrEndo Tracking System. Finally, automatic determination of surgical proficiency based on the MAPs was sought by 3 different approaches to supervised classification (LDA, SVM, ANFIS), with accuracy results of 61.9%, 83.3% and 80.9% respectively. Results not only reflect on the validation of EVA for skills? assessment, but also on the relevance of motion analysis of instruments in the determination of surgical competence.
Resumo:
Analysis of minimally invasive surgical videos is a powerful tool to drive new solutions for achieving reproducible training programs, objective and transparent assessment systems and navigation tools to assist surgeons and improve patient safety. This paper presents how video analysis contributes to the development of new cognitive and motor training and assessment programs as well as new paradigms for image-guided surgery.
Resumo:
Analysis of minimally invasive surgical videos is a powerful tool to drive new solutions for achieving reproducible training programs, objective and transparent assessment systems and navigation tools to assist surgeons and improve patient safety. This paper presents how video analysis contributes to the development of new cognitive and motor training and assessment programs as well as new paradigms for image-guided surgery.
Resumo:
Residents learning nontechnical skills in Europe face two problems: (1) the difficulty to fit learning time in their overloaded schedules; and (2) the lack of standard pedagogical models for all countries. Online video-based repositories such as WeBSurg or WebOP provide ubiquitous access to surgical contents. However, their pedagogical facets have not been fully exploited and they are often seen as quick-reference repositories rather than full e-learning alternatives. We present a new pedagogically-supported Technology Enhanced Learning (TEL) solution, MISTELA, designed by surgeons, pedagogical experts and engineers. MISTELA aims at building a common European pedagogical model supported by ICT technologies and elearning. The solution proposes a pedagogical model based on a framework for pedagogically-informed design of e-learning platforms. It is composed of (1) an authoring tool for editing and augmenting videos; (2) a media asset management system; and (3) a virtual learning environment. Support of the European Association for Endoscopic Surgery (EAES) and validation of the solution, will help to determine its full potential.
Resumo:
Funding This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme.
Resumo:
Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Resumo:
The respiratory effects of dexmedetomidine were retrospectively examined in 33 postsurgical patients involved in a randomised, placebo-controlled trial after extubation in the intensive care unit (ICU). Morphine requirements were reduced by over 50% in patients receiving dexmedetomidine. There were no differences in respiratory rates, oxygen saturations, arterial pH and arterial partial carbon dioxide tension (PaCO2) between the groups. Interestingly the arterial partial oxygen tension (PaO2) : fractional inspired oxygen (FIO2) ratios were statistically significantly higher in the dexmedetomidine group. Dexmedetomidine provides important postsurgical analgesia and appears to have no clinically important adverse effects on respiration in the surgical patient who requires intensive care.
Resumo:
Objective: To evaluate the visual and refractive outcomes after phacoemulsification surgery in eyes with isolated lens coloboma. Design: Prospective, consecutive case series. Participants: Eighteen eyes with isolated lens coloboma of 13 patients were included in the study. Mean patient age was 13.9 ± 6.5 years. Methods: Patients underwent phacoemulsification surgery, with combined implantation of capsular tension ring (CTR) and intraocular lens. In colobomas of less than 120°, a CTR was used, whereas in colobomas of more than 120°, a Cionni-modified single eyelet CTR was used to achieve better capsular centration. The main outcome measures were uncorrected distance visual acuity, corrected distance visual acuity, refraction, and keratometry. Results: Mean logMAR uncorrected distance visual acuity and corrected distance visual acuity improved significantly from 1.53 ± 0.35 and 1.02 ± 0.47 before surgery to 0.67 ± 0.51 and 0.52 ± 0.49 at the last visit of the follow-up (p < 0.001). Mean refractive cylinder and spherical equivalent decreased significantly from –6.73 ± 1.73 and –6.72 ± 4.07 D preoperatively to –1.40 ± 1.39 and –0.83 ± 1.31 D at the end of the follow-up (p = 0.001 and p = 0.01, respectively). Mean keratometric astigmatism at preoperative and postoperative visits were 1.58 ± 0.97 and 1.65 ± 0.94 D, respectively (p = 0.70). Conclusions: Phacoemulsification with CTR and intraocular lens implantation is an effective and safe option for providing a refractive correction and a significant visual improvement in eyes with isolated lens coloboma.
Resumo:
Interacting with a computer system in the operating room (OR) can be a frustrating experience for a surgeon, who currently has to verbally delegate to an assistant every computer interaction task. This indirect mode of interaction is time consuming, error prone and can lead to poor usability of OR computer systems. This thesis describes the design and evaluation of a joystick-like device that allows direct surgeon control of the computer in the OR. The device was tested extensively in comparison to a mouse and delegated dictation with seven surgeons, eleven residents, and five graduate students. The device contains no electronic parts, is easy to use, is unobtrusive, has no physical connection to the computer and makes use of an existing tool in the OR. We performed a user study to determine its effectiveness in allowing a user to perform all the tasks they would be expected to perform on an OR computer system during a computer-assisted surgery. Dictation was found to be superior to the joystick in qualitative measures, but the joystick was preferred over dictation in user satisfaction responses. The mouse outperformed both joystick and dictation, but it is not a readily accepted modality in the OR.