956 resultados para Structures in Reinforced Concrete


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-06

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shear strengthening is required when an RC beam is found deficient in shear, or when its shear capacity falls below its flexural capacity after flexural strengthening. A recent technique for the shear strengthening of RC beams is to provide additional FRP web reinforcement, commonly in the form of bonded external FRP strips/sheets. Over the last few years, several experimental studies have been conducted on this new strengthening technique, which has established its effectiveness. While experimental methods of investigation are extremely useful in obtaining information about the composite behaviour of FRP and reinforced concrete, the use of numerical models such as the one presented in this paper helps in developing a good understanding of the behaviour at lower costs. In the study presented in this paper, ANSYS finite element program is used to examine the response of beams strengthened in shear by FRPs. The FE model is calibrated against test results performed at the University of Kentucky. Once validated, the model is used to examine the influence of fibre orientation, compressive strength of concrete, area of tensile and compressive reinforcements, and amount and distance between stirrups on the strength and ductility of FRP strengthened beam.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The flat plate system is currently widely used in construction. It permits architectural flexibility, more clear space, less building height, easier formwork, and shorter construction time. However, there remains the problem of brittle punching failure due to the transfer of shearing forces and unbalanced moments at the flat plate-column connection. It is the purpose of this paper to investigate the effects of various interdependent factors that govern the punching shear resistance and behaviour of the flat plate-column connection, as well as their inclusion in current Codes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to investigate the feasibility of detecting and locating damage in large frame structures where visual inspection would be difficult or impossible. This method is based on a vibration technique for non-destructively assessing the integrity of structures by using measurements of changes in the natural frequencies. Such measurements can be made at a single point in the structure. The method requires that initially a comprehensive theoretical vibration analysis of the structure is undertaken and from it predictions are made of changes in dynamic characteristics that will occur if each member of the structure is damaged in turn. The natural frequencies of the undamaged structure are measured, and then routinely remeasured at intervals . If a change in the natural frequencies is detected a statistical method. is used to make the best match between the measured changes in frequency and the family of theoretical predictions. This predicts the most likely damage site. The theoretical analysis was based on the finite element method. Many structures were extensively studied and a computer model was used to simulate the effect of the extent and location of the damage on natural frequencies. Only one such analysis is required for each structure to be investigated. The experimental study was conducted on small structures In the laboratory. Frequency changes were found from inertance measurements on various plane and space frames. The computational requirements of the location analysis are small and a desk-top micro computer was used. Results of this work showed that the method was successful in detecting and locating damage in the test structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several of OPC paste and concrete specimens, with different mix proportions, were cast against CPF and impermeable formwork (IF) and the profiles of pore structure, microhardness and scratch hardness of the cover zone were established. The chloride ingress and the depth of carbonation of the surface zone of concrete cast against CPF and IF were investigated. The main mechanisms controlling the ECR processes and the factors affecting such treatment were critically reviewed. Subsequently, as a means of restoring passivation of steel embedded in carbonated concrete, such HCP specimens were subjected to ECR. The influence of ECR on the chemistry of the pore solution and the microstructure of the surface and the steel/cement past interface zones were also studied. The main findings of this investigation were as follows: (a) The thickness of the microstructure gradient of cover concrete is significantly decreased with increasing period of water curing but is relatively unaffected by curing temperature, w/e ratio and the use of cement replacement materials. (b) The scratch hardness technique was shown to be potentially useful for characterising the microstructure and microhardness gradients of the surface zone. (c) A relationship between the microstructure gradient and mass transport properties of the surface zone was established. (d) The use of CPF resulted in a significant reduction in porosity of both the cement paste matrix and the aggregate/cement paste transition zone, and a marked improvement in the resistance of the surface zone to carbonation and the ingress of chloride ions. (e) The ECR treatment resulted in a marked densification of the pore structure and in changes to the pore solution chemistry and the cement phases of near-surface and steel/cement paste transition zones. This effect was more pronounced with current density, period of treatment and particularly with the use of sodium phosphate as an electrolyte.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a novel in-fibre twist sensor utilising strong polarisation dependent coupling behaviour of fiber Bragg grating with 81° tilted structure. The demonstrated twist sensor has shown high torsion sensitivity and capability of direction recognition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The first investigation of this study is concerned with the reasonableness of the assumptions related to diffusion of water vapour in concrete and with the development of a diffusivity equation for heated concrete. It has been demonstrated that diffusion of water vapour does occur in concrete at all temperatures and that the type of diffusion is concrete is Knudsen diffusion. Neglecting diffusion leads to underestimating the pressure. It results in a maximum pore pressure of less than 1 MPa. It has also been shown that the assumption that diffusion in concrete is molecular is unreasonable even when the tortuosity is considered. Molecular diffusivity leads to overestimating the pressure. It results in a maximum pore pressure of 2.7 MPa of which the vapour pressure is 1.5 MPa while the air pressure is 1.2 MPa. Also, the first diffusivity equation, appropriately named 'concrete diffusivity', has been developed specifically for concrete that determines the effective diffusivity of any gas in concrete at any temperature. In thick walls and columns exposed to fire, concrete diffusivity leads to a maximum pore pressures of 1.5 and 2.2 MPa (along diagonals), respectively, that are almost entirely due to water vapour pressure. Also, spalling is exacerbated, and thus higher pressures may occur, in thin heated sections, since there is less of a cool reservoir towards which vapour can migrate. Furthermore, the reduction of the cool reservoir is affected not only by the thickness, but also by the time of exposure to fire and by the type of exposure, i.e. whether the concrete member is exposed to fire from one or more sides. The second investigation is concerned with examining the effects of thickness and exposure time and type. It has been demonstrated that the build up of pore pressure is low in thick members, since there is a substantial cool zone towards which water vapour can migrate. Thus, if surface and/or explosive spalling occur on a thick member, then such spalling must be due to high thermal stresses, but corner spalling is likely to be pore pressure spalling. However, depending on the exposure time and type, the pore pressures can be more than twice those occurring in thick members and thought to be the maximum that can occur so far, and thus the enhanced propensity of pore pressure spalling occurring on thin sections heated on opposite sides has been conclusively demonstrated to be due to the lack of a cool zone towards which moisture can migrate. Expressions were developed for the determination of the maximum pore pressures that can occur in different concrete walls and columns exposed to fire and of the corresponding times of exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis examines experimentally and theoretically the behaviour and ultimate strength of rectangular reinforced concrete members under combined torsion, shear and bending. The experimental investigation consists of the test results of 38 longitudinally and transversely reinforced concrete beams subjected to combined loads, ten beams of which were tested under pure torsion and self-weight. The behaviour of each test beam from application of the first increment of load until failure is presented. The effects of concrete strength, spacing of the stirrups, the amount of longitudinal steel and the breadth of the section on the ultimate torsional capacity are investigated. Based on the skew-bending mechanism, compatibility, and linear stress-strain relationship for the concrete and the steel, simple rational equations are derived for the three principal modes of failure for the following four types of failure observed in the tests: TYPE I Yielding the reinforcement, at failure, before crushing the concrete. TYPE II Yielding of the web steel only, at failure, before crushing the concrete. TYPE III Yielding of the longitudinal steel only, at failure, before crushing the concrete. TYPE IV Crushing of the concrete, at failure, before yielding of any of the reinforcement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the work presented in this thesis is to produce a direct method to design structures subject to deflection constraints at the working loads. The work carried out can be divided into four main parts. In the first part, a direct design procedure for plane steel frames subjected to sway limitations is proposed. The stiffness equations are modified so that the sway in each storey is equal to some specified values. The modified equations are then solved by iteration to calculate the cross-sectional properties of the columns as well as the other joint displacements. The beam sections are selected initially and then altered in an effort to reduce the total material cost of the frame. A linear extrapolation technique is used to reduce this cost. In this design, stability functions are used so that the effect of axial loads in the members are taken into consideration. The final reduced cost design is checked for strength requirements and the members are altered accordingly. In the second part, the design method is applied to the design of reinforced concrete frames in which the sway in the columns play an active part in the design criteria. The second moment of area of each column is obtained by solving the modified stiffness equations and then used to calculate the mlnlmum column depth required. Again the frame has to be checked for all the ultimate limit state load cases. In the third part, the method is generalised to design pin-jointed space frames for deflection limitatlions. In these the member areas are calculated so that the deflection at a specified joint is equal to its specified value. In the final part, the Lagrange multiplier technique is employed to obtain an optimum design for plane rigidly jointed steel frames. The iteration technique is used here to solve the modified stiffness equations as well as derivative equations obtained in accordance to the requirements of the optimisation method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a novel in-fibre twist sensor utilising strong polarisation dependent coupling behaviour of fiber Bragg grating with 81° tilted structure. The demonstrated twist sensor has shown high torsion sensitivity and capability of direction recognition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In 1934, Arthur Lindo Patterson showed that a map of interatomic vectors is obtainable from measured X-ray diffraction data without phase information. Such maps were interpretable for simple crystal structures, but proliferation and overlapping of peaks caused confusion as the number of atoms increased. Since the peak height of a vector between two particular atoms is related to the product of their atomic numbers, a complicated structure could effectively be reduced to a simple one by including just a few heavy atoms (of high atomic number) since their interatomic vectors would stand out from the general clutter. Once located, these atoms provide approximate phases for Fourier syntheses that reveal the locations of additional atoms. Surveys of small-molecule structures in the Cambridge Structural Database during the periods 1936-1969, when Patterson methods were commonly used, and 1980-2013, dominated by direct methods, demonstrate large differences in the abundance of certain elements. The moderately heavy elements K, Rb, As and Br are the heaviest elements in the structure more than 3 times as often in the early period than in the recent period. Examples are given of three triumphs of the heavy atom method and two initial failures that had to be overcome. © 2014 © 2014 Taylor & Francis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A wide range of non-destructive testing (NDT) methods for the monitoring the health of concrete structure has been studied for several years. The recent rapid evolution of wireless sensor network (WSN) technologies has resulted in the development of sensing elements that can be embedded in concrete, to monitor the health of infrastructure, collect and report valuable related data. The monitoring system can potentially decrease the high installation time and reduce maintenance cost associated with wired monitoring systems. The monitoring sensors need to operate for a long period of time, but sensors batteries have a finite life span. Hence, novel wireless powering methods must be devised. The optimization of wireless power transfer via Strongly Coupled Magnetic Resonance (SCMR) to sensors embedded in concrete is studied here. First, we analytically derive the optimal geometric parameters for transmission of power in the air. This specifically leads to the identification of the local and global optimization parameters and conditions, it was validated through electromagnetic simulations. Second, the optimum conditions were employed in the model for propagation of energy through plain and reinforced concrete at different humidity conditions, and frequencies with extended Debye's model. This analysis leads to the conclusion that SCMR can be used to efficiently power sensors in plain and reinforced concrete at different humidity levels and depth, also validated through electromagnetic simulations. The optimization of wireless power transmission via SMCR to Wearable and Implantable Medical Device (WIMD) are also explored. The optimum conditions from the analytics were used in the model for propagation of energy through different human tissues. This analysis shows that SCMR can be used to efficiently transfer power to sensors in human tissue without overheating through electromagnetic simulations, as excessive power might result in overheating of the tissue. Standard SCMR is sensitive to misalignment; both 2-loops and 3-loops SCMR with misalignment-insensitive performances are presented. The power transfer efficiencies above 50% was achieved over the complete misalignment range of 0°-90° and dramatically better than typical SCMR with efficiencies less than 10% in extreme misalignment topologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Light confinement and controlling an optical field has numerous applications in the field of telecommunications for optical signals processing. When the wavelength of the electromagnetic field is on the order of the period of a photonic microstructure, the field undergoes reflection, refraction, and coherent scattering. This produces photonic bandgaps, forbidden frequency regions or spectral stop bands where light cannot exist. Dielectric perturbations that break the perfect periodicity of these structures produce what is analogous to an impurity state in the bandgap of a semiconductor. The defect modes that exist at discrete frequencies within the photonic bandgap are spatially localized about the cavity-defects in the photonic crystal. In this thesis the properties of two tight-binding approximations (TBAs) are investigated in one-dimensional and two-dimensional coupled-cavity photonic crystal structures We require an efficient and simple approach that ensures the continuity of the electromagnetic field across dielectric interfaces in complex structures. In this thesis we develop \textrm{E} -- and \textrm{D} --TBAs to calculate the modes in finite 1D and 2D two-defect coupled-cavity photonic crystal structures. In the \textrm{E} -- and \textrm{D} --TBAs we expand the coupled-cavity \overrightarrow{E} --modes in terms of the individual \overrightarrow{E} -- and \overrightarrow{D} --modes, respectively. We investigate the dependence of the defect modes, their frequencies and quality factors on the relative placement of the defects in the photonic crystal structures. We then elucidate the differences between the two TBA formulations, and describe the conditions under which these formulations may be more robust when encountering a dielectric perturbation. Our 1D analysis showed that the 1D modes were sensitive to the structure geometry. The antisymmetric \textrm{D} mode amplitudes show that the \textrm{D} --TBA did not capture the correct (tangential \overrightarrow{E} --field) boundary conditions. However, the \textrm{D} --TBA did not yield significantly poorer results compared to the \textrm{E} --TBA. Our 2D analysis reveals that the \textrm{E} -- and \textrm{D} --TBAs produced nearly identical mode profiles for every structure. Plots of the relative difference between the \textrm{E} and \textrm{D} mode amplitudes show that the \textrm{D} --TBA did capture the correct (normal \overrightarrow{E} --field) boundary conditions. We found that the 2D TBA CC mode calculations were 125-150 times faster than an FDTD calculation for the same two-defect PCS. Notwithstanding this efficiency, the appropriateness of either TBA was found to depend on the geometry of the structure and the mode(s), i.e. whether or not the mode has a large normal or tangential component.