784 resultados para Sri Lankan Tamils


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sustained driving in older age has implications for quality of life and mental health. Studies have shown that despite the recognised importance of driving in maintaining health and social engagement, many women give up driving prematurely or adopt self-imposed restrictive driving practices. Emotional responses to driving have been implicated in these decisions. This research examined the effect of risk perception and feelings of vulnerability on women’s driving behaviour across the lifespan. It also developed and tested a modified theory of planned behaviour intervention to positively affect driving habits. The first two studies (N=395) used quantitative analysis to model driving behaviours affected by risk perception and feelings of vulnerability, and established that feelings of vulnerability do indeed affect women’s driving behaviour, specifically resulting in increases in driving avoidance and the adoption of maladaptive driving styles. Further, that self-regulation, conceptualised as avoidance, is used by drivers across the lifespan. Qualitative analysis of focus group data (N=48) in the third study provided a deeper understanding of the variations in coping behaviours adopted by sub-groups of drivers and extended the definition of self-regulation to incorporate adaptive coping strategies. The next study (N=64) reported the construction and preliminary validation of the novel self-regulation index (SRI) to measure wider self-regulation behaviours using an objective measure of driving behaviour, a simulated driving task. The understanding gained from the formative research was used in the final study, an extended theory of planned behaviour intervention to promote wider self-regulation behaviour, measured using the previously validated self-regulation index. The intervention achieved moderate success with changes in affective attitude and normative beliefs as well as self-reported behaviour. The results offer promise for self-regulation, incorporating a spectrum of planning and coping behaviours, to be used as a mechanism to assist drivers in achieving their personal mobility goals whilst promoting safe driving.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is the first study to provide comprehensive analyses of the relative performance of both socially responsible investment (SRI) and Islamic mutual funds. The analysis proceeds in two stages. In the first, the performance of the two categories of funds is measured using partial frontier methods. In the second stage, we use quantile regression techniques.By combining two variants of the Free Disposal Hull (FDH) methods (order-m and order-?) in the first stage of analysis and quantile regression in the second stage, we provide detailed analyses of the impact of different covariates across methods and across different quantiles. In spite of the differences in the screening criteria and portfolio management of both types of funds, variation in the performance is only found for some of the quantiles of the conditional distribution of mutual fund performance. We established that for the most inefficient funds the superior performance of SRI funds is significant. In contrast, for the best mutual funds this evidence vanished and even Islamic funds perform better than SRI.These results show the benefits of performing the analysis using quantile regression.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We demonstrate a liquid level sensor based on the surrounding medium refractive index (SRI) sensing using of an excessively tilted fibre Bragg grating (ETFBG). The sensor has low thermal cross sensitivity and high SRI responsivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A compact scheme for simultaneous temperature and surrounding refractive index (SRI) measurement using two long-period gratings (LPGs) of different periods inscribed side-by-side in a single piece of a double-cladding fibre is presented. One of the LPGs is sensitive to both SRI and temperature, whilst the second is sensitive to temperature only.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a compact scheme for simultaneous temperature and surrounding refractive index (SRI) measurement using two long period gratings (LPGs) of different periods inscribed side-by-side in a single piece of a double-cladding fibre. One of the LPGs is sensitive to both SRI and temperature changes whilst the second is SRI-insensitive but shows spectral shift with temperature changes. In addition, we show that a resonance peak of the SRI-insensitive LPG can be designed to appear in the EDFA wavelength region with potential use for gain flattening applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is the first study to provide comprehensive analyses of the relative performance of both socially responsible investment (SRI) and Islamic mutual funds. The analysis proceeds in two stages. In the first, the performance of the two categories of funds is measured using partial frontier methods. In the second stage, we use quantile regression techniques. By combining two variants of the Free Disposal Hull (FDH) methods (order- m and order- α) in the first stage of analysis and quantile regression in the second stage, we provide detailed analyses of the impact of different covariates across methods and across different quantiles. In spite of the differences in the screening criteria and portfolio management of both types of funds, variation in the performance is only found for some of the quantiles of the conditional distribution of mutual fund performance. We established that for the most inefficient funds the superior performance of SRI funds is significant. In contrast, for the best mutual funds this evidence vanished and even Islamic funds perform better than SRI. These results show the benefits of performing the analysis using quantile regression. © 2013 Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analyse the performance persistence of Islamic and Socially Responsible Investment (SRI) mutual funds. We adopt a multi-stage strategy in which, in the first stage, partial frontiers’ approaches are considered to measure the performance of the different funds in the sample. In the second stage, the results yielded by the partial frontiers are plugged into different investment strategies based on a recursive estimation methodology whose persistence performance is evaluated in the third stage of the analysis. Results indicate that, for both types of funds, performance persistence actually exists, but only for the worst and, most notably, best funds. This result is robust not only across methods (and different choices of tuning parameters within each method) but also across both SRI and Islamic funds—although in the case of the latter persistence was stronger for the best funds. The persistence of SRI and Islamic funds represents an important result for investors and the market, since it provides information on both which funds to invest in and which funds to avoid. Last but not least, the use of the aforementioned techniques in the context of mutual funds could also be of interest for the non-conclusive literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inhaled human insulin (Exubera®) is a rapid-acting regular human insulin administered by oral inhalation before meals. It provides a non-invasive alternative to multiple subcutaneous injections for the treatment of hyperglycemia in adult patients with type 1 and type 2 diabetes. Compared with subcutaneous rapid-acting insulin analogs, Exubera provides equivalent HbA1c control. As a monotherapy or in combination with oral agents, Exubera also provides greater glycemic control than oral agents alone, at least in patients with high levels of HbA1c. Exubera demonstrates improved patient satisfaction compared with subcutaneous insulin or oral agents alone. When offered as a treatment option together with standard treatments in uncontrolled patients naive to insulin, Exubera increases acceptance of insulin therapy three-fold compared with patients offered standard regimens only. Exubera is well tolerated in comparison to subcutaneous insulin, with a similar incidence of mild to moderate hypoglycemia. Although cough is a common adverse effect early in therapy, this leads to treatment discontinuations in less than 1% of patients. Despite an increased incidence of insulin antibodies compared with subcutaneous administration, and a consistent but minor impact on pulmonary function, long-term safety data of up to 4 years continue to support the safety profile of Exubera.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The turning point of the refractive index (RI) sensitivity based on the multimode microfiber (MMMF) in-line Mach–Zehnder interferometer (MZI) is observed. By tracking the resonant wavelength shift of the MZI generated between the HE11 and HE12 modes in the MMMF, the surrounding RI (SRI) could be detected. Theoretical analysis demonstrates that the RI sensitivity will reach ±∞ on either side of the turning point due to the group effective RI difference (퐺) approaching zero. Significantly, the positive sensitivity exists in a very wide fiber diameter range, while the negative sensitivity can be achieved in a narrow diameter range of only 0.3 μm. Meanwhile, the experimental sensitivities and variation trend at different diameters exhibit high consistency with the theoretical results. High RI sensitivity of 10777.8 nm/RIU (RI unit) at the fiber diameter of 4.6 μm and the RI around 1.3334 is realized. The discovery of the sensitivity turning points has great significance on trace detection due to the possibility of ultrahigh RI sensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis presents a detailed numerical analysis, fabrication method and experimental investigation on 45º tilted fiber gratings (45º-TFGs) and excessively tilted fiber gratings (Ex-TFGs), and their applications in fiber laser and sensing systems. The one of the most significant contributions of the work reported in this thesis is that the 45º-TFGs with high polarization extinction ratio (PER) have been fabricated in single mode telecom and polarization maintaining (PM) fibers with spectral response covering three prominent optic communication and central wavelength ranges at 1060nm, 1310nm and 1550nm. The most achieved PERs for the 45º-TFGs are up to and greater than 35-50dB, which have reached and even exceeded many commercial in-fiber polarizers. It has been proposed that the 45º-TFGs of high PER can be used as ideal in-fiber polarizers for a wide range of fiber systems and applications. In addition, in-depth detailed theoretical models and analysis have been developed and systematic experimental evaluation has been conducted producing results in excellent agreement with theoretical modeling. Another important outcome of the research work is the proposal and demonstration of all fiber Lyot filters (AFLFs) implemented by utilizing two (for a single stage type) and more (for multi-stage) 45º-TFGs in PM fiber cavity structure. The detailed theoretical analysis and modelling of such AFLFs have also been carried out giving design guidance for the practical implementation. The unique function advantages of 45º-TFG based AFLFs have been revealed, showing high finesse multi-wavelength transmission of single polarization and wide range of tuneability. The temperature tuning results of AFLFs have shown that the AFLFs have 60 times higher thermal sensitivity than the normal FBGs, thus permitting thermal tuning rate of ~8nm/10ºC. By using an intra-cavity AFLF, an all fiber soliton mode locking laser with almost total suppression of siliton sidebands, single polarization output and single/multi-wavelength switchable operation has been demonstrated. The final significant contribution is the theoretical analysis and experimental verification on the design, fabrication and sensing application of Ex-TFGs. The Ex-TFG sensitivity model to the surrounding medium refractive index (SRI) has been developed for the first time, and the factors that affect the thermal and SRI sensitivity in relation to the wavelength range, tilt angle, and the size of cladding have been investigated. As a practical SRI sensor, an 81º-TFG UV-inscribed in the fiber with small (40μm) cladding radius has shown an SRI sensitivity up to 1180nm/RIU in the index of 1.345 range. Finally, to ensure single polarization detection in such an SRI sensor, a hybrid configuration by UV-inscribing a 45º-TFG and an 81º-TFG closely on the same piece of fiber has been demonstrated as a more advanced SRI sensing system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

* The work is partially supported by the grant of National Academy of Science of Ukraine for the support of scientific researches by young scientists No 24-7/05, " Розробка Desktop Grid-системи і оптимізація її продуктивності ”.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose and demonstrate an optical liquid level sensor based on the surrounding medium refractive index (SRI) sensing using an excessively tilted fibre grating (ETFG). When the ETFG submerged in water, two sets of cladding modes are coupled, corresponding to air- and water-surrounded grating structures, respectively. The coupling strengths of the two sets of cladding modes evolve with the submerging length of the grating, providing a mechanism to measure the liquid level. Comparing with long-period fibre grating based liquid level sensor, the ETFG sensor has a much higher SRI responsivity for liquids with refractive index around 1.33 and a lower thermal cross sensitivity. © 2013 Published by Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have proposed and demonstrated a fibre laser system using a microchannel as a cavity loss tuning element for surrounding medium refractive index (SRI) sensing. A ~6µm width microchannel was created by femtosecond (fs) laser inscription assisted chemical etching in the cavity fibre, which offers a direct access to the external liquids. When the SRI changes, the microchannel behaves as a loss tuning element, hence modulating the laser cavity loss and output power. The results indicate that the presented laser sensing system has a linear response to the SRI with a sensitivity in the order of 10-5. Using higher pump power and more sensitive photodetector, the SRI sensitivity could be further enhanced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have theoretically and experimentally investigated the dual-peak feature of tilted fiber gratings with excessively tilted structure (named as Ex-TFGs). We have explained the dual-peak feature by solving eigenvalue equations for TM0m and TE0m of a circular waveguide, in which the TE (transverse electric) and TM (transverse magnetic) core modes are coupled into TE and TM cladding modes, respectively. Meanwhile, in the experiment, we have verified that one of the dual peaks at the shorter wavelength is due to the TM mode coupling whereas the other one at the longer wavelength arises from TE mode coupling when a linearly polarized light launched into the Ex-TFG. We have also investigated the peak separation of TE and TM cladding mode for different surrounding medium refractive indexes (SRI), revealed that the dual peaks separation is decreasing as increasing of SRI, which agrees very well with the theoretical analysis results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, a graphene oxide-coated long period fibre grating (GO-LPG) is proposed for chemical sensing application. Graphene oxide (GO) has been deposited on the surface of long period grating to form a sensing layer which significantly enhances the interaction between LPG propagating light and the surrounding-medium. The sensing mechanism of GO-LPG relies on the change of grating resonance intensity against surrounding-medium refractive index (SRI). The proposed GO-LPG has been used to measure the concentrations of sugar aqueous solutions. The refractive index sensitivities with 99.5 dB/RIU in low refractive index region (1.33-1.35) and 320.6 dB/RIU in high index region (1.42-1.44) have been achieved, showing an enhancement by a factor of 3.2 and 6.8 for low and high index regions, respectively. The proposed GO-LPG can be further extended to the development of optical biochemical sensor with advantages of high sensitivity, real-time and label-free sensing.