906 resultados para Solar refrigeration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this analysis, using available hourly and daily radiometric data performed at Botucatu, Brazil, several empirical models relating ultraviolet (UV), photosynthetically active (PAR) and near infrared (NIR) solar global components with solar global radiation (G) are established. These models are developed and discussed through clearness index K(T) (ratio of the global-to-extraterrestrial solar radiation). Results obtained reveal that the proposed empirical models predict hourly and daily values accurately. Finally. the overall analysis carried Out demonstrates that the sky conditions are more important in developing correlation models between the UV component and the global solar radiation. The linear regression models derived to estimate PAR and NIR components may be obtained without sky condition considerations within a maximum variation of 8%. In the case of UV, not taking into consideration the sky condition may cause a discrepancy of up to 18% for hourly values and 15% for daily values. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to estimate the deforestation consequences on the actual solar energy budget of the Central Amazon Region, two ecosystems of different characteristics were compared. The present conditions of the region were represented by a typical 'terra firme' forest cover located at INPA's Ducke Forest Reserve, where the measurements necessary to evaluate its solar energy balance were carried out. The second ecosystem, simulating a deforested area, was represented by an area about 1.0 ha without natural vegetation and situated in the same Reserve. In this area lysimeters were placed, two of them filled with yellow latosol and two others with quartzose sand soil. Both soils are representative soils in the region. Their water balances were taken into account as well as the other parameters necessary to compute the solar energy balances. The results showed that water loss by evaporation was about 41.8% of the total precipitation in the yellow latosol lysimeters and about 26.4% for the quartzose sand ones. For the forest cover it was estimated an evapotranspiration of 67.9% of the rainfall amount. In relation to solar energy balance calculated for the forest cover, it was found that 83.1% of the total energy incoming to this ecosystem was used by the evapotranspiration process, while the remaining of 16.9% can be taken as sensible heat. For bare soils, 55.1% and 31.8% of the total energy were used as latent heat by yellow latosol and quartzose sand soils, respectively. So, the remaining amounts of 44.9% and 68.2% were related to sensible heat and available to atmospheric air heating of these ecosystems. Such results suggest that a large deforestation of the Amazon Region would have direct consequences on their water and solar radiation balances, with an expected change on the actual climatic conditions of the region. © 1993.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A semi-analytical approach is proposed to study the rotational motion of an artificial satellite under the influence of the torque due to the solar radiation pressure and taking into account the influence of Earth's shadow. The Earth's shadow is introduced in the equations for the rotational motion as a function depending on the longitude of the Sun, on the ecliptic's obliquity and on the orbital parameters of the satellite. By mapping and computing this function, we can get the periods in which the satellite is not illuminated and the torque due to the solar radiation pressure is zero. When the satellite is illuminated, a known analytical solution is used to predict the satellite's attitude. This analytical solution is expressed in terms of Andoyer's variables and depends on the physical and geometrical properties of the satellite and on the direction of the Sun radiation flux. By simulating a hypothetical circular cylindrical type satellite, an example is exhibited and the results agree quite well when compared with a numerical integration. © 1997 COSPAR. Published by Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this research uas to evaluate the effect of five pre-planting refrigeration periods previously to the cloves planting (0,10,20, 30 and 40 days at a temperature of 4.0 ± 1° C and three garlic cultivars ('Chines', 'Contestado' and 'Quiteria') uere used. According to the obtained results it was observed that the best preplanting refrigeration period was dependent upon the cultivar behavior. For the 'Chines' well adapted to the region, there was no effect of the pre-planting refrigeration period up to 30 days after treatment on the plant height, bulb weight, and total bulb production. 'Contestado' the best pre-planting refrigeration period was 40 days however, there was no statistical difference among 30 and 40, days for the 'Quiteria'. For both cultivars pre-planting refrigeration periods under 20 days, there was no clove's formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seasonal variations in the diurnal evolution of the global, diffuse and direct solar radiation at the surface, the clearness index, diffuse fraction and direct fraction are described in detail for the City of Sao Paulo, Brazil. The description is based on measurements of global and diffuse solar radiation carried out over 5.25 years. The diffuse component was measured with a shadow-band device. The annual evolution of the amplitude of the diurnal cycle of all radiometric parameters indicates a seasonal pattern with two distinct periods: autumn-winter and spring-summer. About 10% of the observed period was characterized by clear sky days. This seasonal variation is determined by a larger incidence of clear sky days in the autumn-winter period. Reductions of up to 10% in hourly and daily values of global radiation were observed in conjunction with an increase in particulate matter concentration on clear sky days. The pollution effect may be responsible for the discrepancy, of 16%, found between local and more regional estimates of global solar radiation in Sao Paulo. The diurnal evolution of hourly values of monthly-averaged global and diffuse solar radiation were successfully estimated by the empirical expressions derived here. Daily values of monthly-averaged global solar radiation were satisfactorily estimated using the Angstrom expression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The photo-Fenton process using potassium ferrioxalate as a mediator was investigated for the photodegradation of dichloracetic acid (DCA) and 2,4-dichlorophenol (DCP) in aqueous medium using solar light as source of irradiation. The influence of the solution depth, the light intensity and the effect of stirring the solution during irradiation process were evaluated using DCA as a model compound. A negligible influence of stirring the solution was observed when the concentration of ferrioxalate (FeOx) was 0.8 mM and solution depth was 4.5 or 14 cm. The optimum FeOx concentration determined for solution depths between 4.5 and 14 cm was 0.8 mM considering total organic carbon (TOC) removal during DCA irradiation. The high efficiency of the photo-Fenton process was demonstrated on summer days, when only 10 min of exposition (around noon) were sufficient to completely destroy the organic carbon of a 1.0 mM DCA solution in the presence of 0.8 mM FeOx and 6.0 mM H2O2 using a solution depth of 4.5 cm. It was observed that the photodegradation efficiency increases linearly with the solar light intensity up to values around 15 Wm-2 but this linear relationship does not hold above this value showing a square root dependence. The photodegradation of a solution of DCP/FeOx showed a lower TOC removal rate than that observed for DCA/FeOx, achieving ∼90% after 35 min irradiation under 19 Wm-2, while under this light intensity, the same TOC removal of DCA/FeOx was achieved in only 10 min irradiation. © 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was aimed to extend the postharvest conservation of 'Tommy Atkins' mango fruits harvested in break maturity stage. Fruits were submitted at the following treatments: hot water treatment (55°C for 5 minutes) and benomyl 1,000 mg.L-1; irradiation with 0,8 or 1,0 kGy; irradiation associated at carnaúba wax; and control. The fruits were stored at 10°C and 85 - 90%RH during 21 days, and then removed to ambient temperature (25,7±0,7°C and 87,1±2,2%RH). Through the storage time, the evolution of fresh weight, color, rottenness, total soluble solids (TSS), total titratable acidity (TTA), and TSS/TTA ratio were measured. 'Tommy Atkins' mango fruits can have shelf life notably increased, when they were submitted to hot water treatment (55°C for 5 minutes) or γ radiation (0,8 and 1,0 kGy), associated with carnaúba wax application, before cold storage. These treatments increased the fruit resistance at refrigerated storage, and improved shelflife after transferring to ambient temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of combining the photocatalytic processes using TiO 2 and the photo-Fenton reaction with Fe3+ or ferrioxalate as a source of Fe2+ was investigated in the degradation of 4-chlorophenol (4CP) and dichloroacetic acid (DCA) using solar irradiation. Multivariate analysis was used to evaluate the role of three variables: iron, H2O2 and TiO2 concentrations. The results show that TiO2 plays a minor role when compared to iron and H2O2 in the solar degradation of 4CP and DCA in the studied conditions. However, its presence can improve TOC removal when H2O2 is totally consumed. Iron and peroxide play major roles, especially when Fe(NO3)3 used in the degradation of 4CP. No significant synergistic effect was observed by the addition of TiO 2 in this process. On the other hand, synergistic effects were observed between FeOx and TiO2 and between H 2O2 and TiO2 in the degradation of DCA. © IWA Publishing 2004.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current technological development made by the absorption refrigeration system is an economic and ambient alternative in comparison to the vapor cycle, possessing an advantage that uses thermal energy that is less noble. Chillers of absorption are used widely in the air conditioned industries, because they can be set in motion through hot water vapors that burn natural gas, solar energy, biomasses amongst others instead of electricity. These systems allow it to reduce the tips of electric demand and balance the rocking of energy demand. This work has had a main objective to simulate a absorption refrigeration cycle with lithium-water bromide solution using biogas of sanitary landfill, and mixtures of this with natural gas. These results shown to the energy viability of the system burning biogas and its mixtures with natural gas in the generator, when compared with equipments that uses traditional fuels (natural gas, oil diesel, amongst others), for operation the commercial chillers with 15 kW of the refrigeration capacity and temperature of the water in the entrance of 14°C and the exit of 7°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Incluye bibliografía

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports on the changes of performance of solid-state cells dye-sensitized solar cells with the variation of concentration of spiro-OMeTAD between 5% and 25% in the fabrication of the cell. Variations of charge recombination and capacitance correlate with the improvement of current-potential characteristics at increasing spiro-OMeTAD content, which is explained by reduction of transport resistance for hole transport, the increase of charge separation in the dye molecules, and importantly, with the increase of the β-factor in the recombination resistance, that causes a reduction of the diode ideality factor. © 2010 Materials Research Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The upcoming solar maximum, which is expected to reach its peak around May 2013, occurs at a time when our reliance on high-precision GNSS has reached unprecedented proportions. The perturbations of the ionosphere caused by increased solar activity pose a major threat to these applications. This is particularly true in equatorial regions where high exposure to solar-induced disturbances is coupled with explosive growth of precise GNSS applications. Along with the various types of solar-induced ionospheric disturbances, strong scintillations are amongst the most challenging, causing phase measurement errors up to full losses of lock for several satellites. Brazil, which heavily relies on high-precision GNSS, is one of the most affected regions due notably to the proximity to the southern crest of the ionospheric equatorial anomaly and to the South Atlantic Magnetic Anomaly. In the framework of the CIGALA project, we developed the PolaRxS™, a GNSS receiver dedicated to the monitoring of ionospheric scintillation indices not only in the GPS L1 band but for all operational and upcoming constellations and frequency bands. A network of these receivers was deployed across the whole Brazilian territory in order to first investigate and secondly to mitigate the impact of scintillation on the different signals, ensuring high precision GNSS availability and integrity in the area. This paper reports on the validation of the PolaRxS™ receiver as an ionospheric scintillation monitor and the first results of the analysis of the data collected with the CIGALA network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a climatic and statistical analysis of global, direct horizontal and diffuse radiation from a database of solar radiation measured from 1996 to 2006 in the city of Botucatu, SP, Brazil. Variation intervals of hourly and daily irradiation, annual mean 〈H̄G〉, 〈H̄bh〉 and 〈H̄d〉 irradiation, monthly mean 〈H̄G〉, 〈H̄ bh〉 and 〈H̄d〉 irradiation and monthly mean 〈K̄t〉, 〈K̄bh〉 and 〈K̄d〉 fractions were determined. Results showed that values of hourly and daily annual mean irradiation were as follows: 〈H̄G〉=1.49MJ/m2 and 〈H̄ G〉=17.74MJ/m2; 〈H̄bh〉=0. 90MJ/m2 and 〈H̄bh〉=10.33MJ/m2 and 〈H̄d〉=0.57 MJ/m2 and 〈H̄d〉=7.09MJ/m2, respectively. Variation intervals of hourly monthly mean irradiation were as follows: 〈H̄G〉 ranged from 1.65MJ/m2 in March to 1.16MJ/m2 in June; 〈H̄bh〉 ranged from 1.06MJ/m2 in April to 0.79MJ/m2 in June, and 〈H̄d〉 ranged from 0.70MJ/m2 in January to 0.37MJ/m2 in June and July. Similarly, daily 〈H̄ G〉 irradiation ranged from 21.35MJ/m2 in November to 12.94MJ/m2 in June; 〈H̄bh〉 ranged from 11.83MJ/m2 in April to 8.49MJ/m2 in June, and 〈H̄d〉 ranged from 10.29MJ/m2 in December to 4.38MJ/m2 in June. Variation intervals of hourly monthly mean fractions were as follows: 〈K̄t〉 ranged from 43.5% in January to 54.2% in April; 〈K̄bh〉 ranged from 33.6% in January to 58.0% in April and 〈K̄d〉 ranged from 66.4% in January to 42.0% in April. In the same way, daily 〈K̄ t〉 fractions ranged from 45.5% in January to 59.8% in August; 〈K̄bh〉 ranged from 38.9% in January to 62.0% in August and 〈K̄d〉 ranged from 61.1% in January to 37.7% in July.