941 resultados para Singular optics
Resumo:
PURPOSE - To present the results of same-day topography-guided photorefractive keratectomy (TG-PRK) and corneal collagen cross-linking (CXL) after intrastromal corneal ring (ISCR) implantation in patients with keratoconus. METHODS - Thirty-three patients (41 eyes) aged between 19 and 45 years were included in this prospective study. All patients underwent a femtosecond laser-enabled (Intralase FS; Abbott Medical Optics, Inc.) placement of intracorneal ring segments (Kerarings; Mediphacos, Brazil). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and keratometry readings remained stable for 6 months. Same-day PRK and CXL was subsequently performed in all patients. RESULTS - After 12 months of completion of the procedure, mean UDVA in log of minimal angle of resolution was significantly improved (0.74±0.54-0.10±0.16); CDVA did not improve significantly but 85% of eyes maintained or gained multiple lines of CDVA; mean refraction spherical equivalent improved (from -3.03±1.98 to -0.04±0.99 D), all keratometry readings were significantly reduced, from preoperative values, but coma did not vary significantly from preoperative values. Central corneal thickness and corneal thickness at the thinnest point were significantly (P<0.0001) reduced from 519.76±29.33 and 501.87±31.50 preoperatively to 464.71±36.79 and 436.55±47.42 postoperatively, respectively. Safety and efficacy indices were 0.97 and 0.88, respectively. From 6 months up until more than 1 year of follow-up, further significant improvement was observed only for UDVA (P<0.0001). CONCLUSIONS - Same-day combined TG-PRK and CXL after ISCR implantation is a safe and effective option for improving visual acuity and visual function, and it halts the progression of the keratoconus. The improvements recorded after 6 months of follow-up were maintained or improved upon 1 year after the procedure.
Resumo:
In this paper we excite bound long range stripe plasmon modes with a highly focused laser beam. We demonstrate highly confined plasmons propagating along a 50 μm long silver stripe 750 nm wide and 30 nm thick. Two excitation techniques were studied: focusing the laser spot onto the waveguide end and focusing the laser spot onto a silver grating. By comparing the intensity of the out-coupling photons at the end of the stripe for both grating and end excitation we are able to show that gratings provide an increase of a factor of two in the output intensity and thus out-coupling of plasmons excited by this technique are easier to detect. Authors expect that the outcome of this paper will prove beneficial for the development of passive nano-optical devices based on stripe waveguides, by providing insight into the different excitation techniques available and the advantages of each technique.
Resumo:
Purpose There have been only a limited number of studies examining the accommodative response that occurs when the two eyes are provided with disparate accommodative stimuli, and the results from these studies to date have been equivocal. In this study, we therefore aimed to examine the capacity of the visual system to aniso-accommodate by objectively measuring the interocular difference in the accommodation response between fellow dominant and non-dominant eyes under controlled monocular and binocular viewing conditions during short-term exposure to aniso-accommodative stimuli. Methods The accommodative response of each eye of sixteen young isometropic adults (mean age 22 ± 2 years) with normal binocular vision was measured using an open-field autorefractor during a range of testing conditions; monocularly (accommodative demands ranging from 1.32 to 4.55 D) and binocularly while altering the accommodation demand for each eye (aniso-accommodative stimuli ranging from 0.24 to 2.05 D). Results Under monocular viewing conditions, the dominant and non-dominant eyes displayed a highly symmetric accommodative response; mean interocular difference in spherical equivalent 0.01 ± 0.06 D (relative) and 0.22 ± 0.06 D (absolute) (p>0.05). During binocular viewing, the dominant eye displayed a greater accommodative response (0.11 ± 0.34 D relative and 0.24 ± 0.26 D absolute) irrespective of whether the demand of the dominant or non-dominant eye was altered (p = 0.01). Astigmatic power vectors J0 and J45 did not vary between eyes or with increasing accommodation demands under monocular or binocular viewing conditions (p>0.05). Conclusion The dominant and non-dominant eyes of young isometropic individuals display a similar consensual lag of accommodation under both monocular and binocular viewing conditions, with the dominant eye showing a small but significantly greater (by 0.12 to 0.25 D) accommodative response. Evidence of short-term aniso-accommodation in response to asymmetric accommodation demands was not observed.
Resumo:
Piezoelectric polymers based on polyvinylidene fluoride (PVDF) are of interest as smart materials for novel space-based telescope applications. Dimensional adjustments of adaptive thin polymer films are achieved via controlled charge deposition. Predicting their long-term performance requires a detailed understanding of the piezoelectric property changes that develop during space environmental exposure. The overall materials performance is governed by a combination of chemical and physical degradation processes occurring in low Earth orbit as established by our past laboratory-based materials performance experiments (see report SAND 2005-6846). Molecular changes are primarily induced via radiative damage, and physical damage from temperature and atomic oxygen exposure is evident as depoling, loss of orientation and surface erosion. The current project extension has allowed us to design and fabricate small experimental units to be exposed to low Earth orbit environments as part of the Materials International Space Station Experiments program. The space exposure of these piezoelectric polymers will verify the observed trends and their degradation pathways, and provide feedback on using piezoelectric polymer films in space. This will be the first time that PVDF-based adaptive polymer films will be operated and exposed to combined atomic oxygen, solar UV and temperature variations in an actual space environment. The experiments are designed to be fully autonomous, involving cyclic application of excitation voltages, sensitive film position sensors and remote data logging. This mission will provide critically needed feedback on the long-term performance and degradation of such materials, and ultimately the feasibility of large adaptive and low weight optical systems utilizing these polymers in space.
Resumo:
Purpose Optical blur and ageing are known to affect driving performance but their effects on drivers' eye movements are poorly understood. This study examined the effects of optical blur and age on eye movement patterns and performance on the DriveSafe slide recognition test which is purported to predict fitness to drive. Methods Twenty young (27.1 ± 4.6 years) and 20 older (73.3 ± 5.7 years) visually normal drivers performed the DriveSafe under two visual conditions: best-corrected vision and with +2.00 DS blur. The DriveSafe is a Visual Recognition Slide Test that consists of brief presentations of static, real-world driving scenes containing different road users (pedestrians, bicycles and vehicles). Participants reported the types, relative positions and direction of travel of the road users in each image; the score was the number of correctly reported items (maximum score of 128). Eye movements were recorded while participants performed the DriveSafe test using a Tobii TX300 eye tracking system. Results There was a significant main effect of blur on DriveSafe scores (best-corrected: 114.9 vs blur: 93.2; p < 0.001). There was also a significant age and blur interaction on the DriveSafe scores (p < 0.001) such that the young drivers were more negatively affected by blur than the older drivers (reductions of 22% and 13% respectively; p < 0.001): with best-corrected vision, the young drivers performed better than the older drivers (DriveSafe scores: 118.4 vs 111.5; p = 0.001), while with blur, the young drivers performed worse than the older drivers (88.6 vs 95.9; p = 0.009). For the eye movement patterns, blur significantly reduced the number of fixations on road users (best-corrected: 5.1 vs blur: 4.5; p < 0.001), fixation duration on road users (2.0 s vs 1.8 s; p < 0.001) and saccade amplitudes (7.4° vs 6.7°; p < 0.001). A main effect of age on eye movements was also found where older drivers made smaller saccades than the young drivers (6.7° vs 7.4°; p < 0.001). Conclusions Blur reduced DriveSafe scores for both age groups and this effect was greater for the young drivers. The decrease in number of fixations and fixation duration on road users, as well as the reduction in saccade amplitudes under the blurred condition, highlight the difficulty experienced in performing the task in the presence of optical blur, which suggests that uncorrected refractive errors may have a detrimental impact on aspects of driving performance.
Resumo:
Arts culture organisations and funding authorities increasingly need to evaluate the impact of festivals, events and performances. Economic impacts are often privileged over 'soft data' about community experience and engagement. This new book offers a timely and scholarly demonstration of how cultural value and impact can be evaluated. It offers an innovative approach whereby the relationship developed between the researchers/evaluator and the commissioning arts and cultural producer provides an opportunity to rethink the traditional process of reporting back on value and impact through the singular entity of funds acquittal. Using three commissioned evaluations undertaken at an Australian university as an extended case study, the book investigates the two positions most often adopted by researchers/evaluators - embedded and collaborative, or external and distanced - and argues the merits and deficiencies of the two approaches. Offering an examination of how arts evaluation 'works' in theory and practice and more importantly, why it is needed now and in the future to demonstrate the reach and cultural gains from arts and cultural projects, this will be essential reading for students in arts management, professionals working in arts and cultural organisations, scholars working in association with creative industries and cultural development.
Resumo:
Fiber Bragg Grating (FBG) accelerometers using transverse forces with an inertial object placed at the middle of the FBG have a high sensitivity but low resonant frequency. The resonant frequency 26 Hz and sensitivity at 6 Hz 1.29 nm/g were reported based on a 50mm-long FBG accelerometer. We demonstrate that the first FBG accelerometer based on a transversely rotating stick, which can, at the same or even larger size, keep the high sensitivity and significantly increase the low resonant frequency. In our experiments, a 77.5mm-long FBG accelerometer has achieved a similar sensitivity but 65% higher resonant frequency. This novel structure not only significantly widens the potential applications of FBG accelerometers by increasing their resonant frequencies but also provides a new route to design other accelerometers, e.g. micro accelerometers.
Resumo:
In this paper we image the highly confined long range plasmons of a nanoscale metal stripe waveguide using quantum emitters. Plasmons were excited using a highly focused 633 nm laser beam and a specially designed grating structure to provide stronger incoupling to the desired mode. A homogeneous thin layer of quantum dots was used to image the near field intensity of the propagating plasmons on the waveguide. We observed that the photoluminescence is quenched when the QD to metal surface distance is less than 10 nm. The optimised spacer layer thickness for the stripe waveguides was found to be around 20 nm. Authors believe that the findings of this paper prove beneficial for the development of plasmonic devices utilising stripe waveguides.
Resumo:
From the onset of the first microscopic visualization of single fluorescent molecules in living cells at the beginning of this century, to the present, almost routine application of single molecule microscopy, the method has well-proven its ability to contribute unmatched detailed insight into the heterogeneous and dynamic molecular world life is composed of. Except for investigations on bacteria and yeast, almost the entire story of success is based on studies on adherent mammalian 2D cell cultures. However, despite this continuous progress, the technique was not able to keep pace with the move of the cell biology community to adapt 3D cell culture models for basic research, regenerative medicine, or drug development and screening. In this review, we will summarize the progress, which only recently allowed for the application of single molecule microscopy to 3D cell systems and give an overview of the technical advances that led to it. While initially posing a challenge, we finally conclude that relevant 3D cell models will become an integral part of the on-going success of single molecule microscopy.
Resumo:
PURPOSE To estimate refractive indices used by the Lenstar biometer to translate measured optical path lengths into geometrical path lengths within the eye. METHODS Axial lengths of model eyes were determined using the IOLMaster and Lenstar biometers; comparing those lengths gave an overall eye refractive index estimate for the Lenstar. Using the Lenstar Graphical User Interface, we noticed that boundaries between media could be manipulated and opposite changes in optical path lengths on either side of the boundary could be introduced. Those ratios were combined with the overall eye refractive index to estimate separate refractive indices. Furthermore, Haag-Streit provided us with a template to obtain 'air thicknesses' to compare with geometrical distances. RESULTS The axial length estimates obtained using the IOLMaster and the Lenstar agreed to within 0.01 mm. Estimates of group refractive indices used in the Lenstar were 1.340, 1.341, 1.415, and 1.354 for cornea, aqueous, lens, and overall eye, respectively. Those refractive indices did not match those of schematic eyes, but were close in the cases of aqueous and lens. Linear equations relating air thicknesses to geometrical thicknesses were consistent with our findings. CONCLUSION The Lenstar uses different refractive indices for different ocular media. Some of the refractive indices, such as that for the cornea, are not physiological; therefore, it is likely that the calibrations in the instrument correspond to instrument-specific corrections and are not the real optical path lengths.
Resumo:
A recent suggestion by a reviewer of a manuscript that the use of the word ‘hypermetropia’ was incorrect and that it should be replaced by ‘hyperopia’ caused us to look again at the literature of the subject to see if this criticism was justified. The background is an interesting one...
Resumo:
With the use of tensor analysis and the method of singular surfaces, an infinite system of equations can be derived to study the propagation of curved shocks of arbitrary strength in gas dynamics. The first three of these have been explicitly given here. This system is further reduced to one involving scalars only. The choice of dependent variables in the infinite system is quite important, it leads to coefficients free from singularities for all values of the shock strength.
Resumo:
This paper addresses the problem of singularity-free path planning for the six-degree-of-freedom parallel manipulator known as the Stewart platform manipulator. Unlike serial manipulators, the Stewart platform possesses singular configurations within the workspace where the manipulator is uncontrollable. An algorithm has been developed to construct continuous paths within the workspace of the manipulator by avoiding singularities and ill-conditioning. Given two end-poses of the manipulator, the algorithm finds out safe (well-conditioned) via points and plans a continuous path from the initial pose to the final one. When the two end-poses belong to different branches and no singularity-free path is possible, the algorithm indicates the impossibility of a valid path. A numerical example has also been presented as illustration of the path planning strategy.
Resumo:
A defect-selective photothermal imaging system for the diagnostics of optical coatings is demonstrated. The instrument has been optimized for pump and probe parameters, detector performance, and signal processing algorithm. The imager is capable of mapping purely optical or thermal defects efficiently in coatings of low damage threshold and low absorbance. Detailed mapping of minor inhomogeneities at low pump power has been achieved through the simultaneous action of a low-noise fiber optic photothermal beam defection sensor and a common-mode-rejection demodulation (CMRD) technique. The linearity and sensitivity of the sensor have been examined theoretically and experimentally, and the signal to noise ratio improvement factor is found to be about 110 compared to a conventional bicell photodiode. The scanner is so designed that mapping of static or shock sensitive samples is possible. In the case of a sample with absolute absorptance of 3.8 x 10(-4), a change in absorptance of about 0.005 x 10(-4) has been detected without ambiguity, ensuring a contrast parameter of 760. This is about 1085% improvement over the conventional approach containing a bicell photodiode, at the same pump power. The merits of the system have been demonstrated by mapping two intentionally created damage sites in a MgF2 coating on fused silica at different excitation powers. Amplitude and phase maps were recorded for thermally thin and thick cases, and the results are compared to demonstrate a case which, in conventional imaging, would lead to a deceptive conclusion regarding the type and location of the damage. Also, a residual damage profile created by long term irradiation with high pump power density has been depicted.
Resumo:
This paper presents the proper computational approach for the estimation of strain energy release rates by modified crack closure integral (MCCI). In particular, in the estimation of consistent nodal force vectors used in the MCCI expressions for quarter-point singular elements (wherein all the nodal force vectors participate in computation of strain energy release rates by MCCI). The numerical example of a centre crack tension specimen under uniform loading is presented to illustrate the approach.