992 resultados para Single pulse waveform


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we show that the orthorhombic phase of FeSi2 (stable at room temperature) displays a sizable anisotropy in the infrared spectra, with minor effects in the Raman data too. This fact is not trivial at all, since the crystal structure corresponds to a moderate distortion of the fluorite symmetry. Our analysis is carried out on small single crystals grown by flux transport, through polarization-resolved far-infrared reflectivity and Raman measurements. Their interpretation has been obtained by means of the simulated spectra with tight-binding molecular dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present our recent achievements in the growing and optical characterization of KYb(WO4)2 (hereafter KYbW) crystals and demonstrate laser operation in this stoichiometric material. Single crystals of KYbW with optimal crystalline quality have been grown by the top-seeded-solution growth slow-cooling method. The optical anisotropy of this monoclinic crystal has been characterized, locating the tensor of the optical indicatrix and measuring the dispersion of the principal values of the refractive indices as well as the thermo-optic coefficients. Sellmeier equations have been constructed valid in the visible and near-IR spectral range. Raman scattering has been used to determine the phonon energies of KYbW and a simple physical model is applied for classification of the lattice vibration modes. Spectroscopic studies (absorption and emission measurements at room and low temperature) have been carried out in the spectral region near 1 µm characteristic for the ytterbium transition. Energy positions of the Stark sublevels of the ground and the excited state manifolds have been determined and the vibronic substructure has been identified. The intrinsic lifetime of the upper laser level has been measured taking care to suppress the effect of reabsorption and the intrinsic quantum efficiency has been estimated. Lasing has been demonstrated near 1074 nm with 41% slope efficiency at room temperature using a 0.5 mm thin plate of KYbW. This laser material holds great promise for diode pumped high-power lasers, thin disk and waveguide designs as well as for ultrashort (ps/fs) pulse laser systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We obtained Ba3Yb(BO3)3 single crystals by the flux method with solutions of the BaB2O4Na2OYb2O3 system. The evolution of the cell parameters with temperature shows a slope change at temperatures near 873 K, which may indicate a phase transition that is not observed by changes appearing in the x-ray powder patterns or by differential thermal analysis (DTA). The evolution of the diffraction patterns with the temperature shows incongruent melting at temperatures higher than 1473 K. DTA indicates that there is incongruent melting and this process is irreversible. Ba3Yb(BO3)3 has a wide transparency window from 247 to 3900 nm. We recorded optical absorption and emission spectra at room and low temperature, and we determined the splitting of Yb3+ ions. We used the reciprocity method to calculate the maximum emission cross section of 0.28 10-20 cm2 at 966 nm. The calculated lifetime of Yb3+ in Ba3Yb(BO3)3 is trad = 2.62 ms, while the measured lifetime is t = 3.80 ms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single-valued solutions for the case of two-sided market games without product differentiation, also known as Böhm-Bawerk horse market games, are analyzed. The nucleolus is proved to coincide with the tau-value, and is thus the midpoint of the core. Moreover a characterization of this setof games in terms of the assignment matrix is provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[cat] En aquest treball caracteritzem les solucions puntuals de jocs cooperatius d'utilitat transferible que compleixen selecció del core i monotonia agregada. També mostrem que aquestes dues propietats són compatibles amb la individualitat racional, la propietat del jugador fals i la propietat de simetria. Finalment, caracteritzem les solucions puntuals que compleixen les cinc propietats a l'hora.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alloreactive T cells are thought to be a potentially rich source of high-avidity T cells with therapeutic potential since tolerance to self-Ags is restricted to self-MHC recognition. Given the particularly high frequency of alloreactive T cells in the peripheral immune system, we used numerous MHC class I multimers to directly visualize and isolate viral and tumor Ag-specific alloreactive CD8 T cells. In fact, all but one specificities screened were undetectable in ex vivo labeling. In this study, we report the occurrence of CD8 T cells specifically labeled with allo-HLA-A*0201/Melan-A/MART-1(26-35) multimers at frequencies that are in the range of 10(-4) CD8 T cells and are thus detectable ex vivo by flow cytometry. We report the thymic generation and shaping of tumor Ag-specific, alloreactive T cells as well as their fate once seeded in the periphery. We show that these cells resemble their counterparts in HLA-A*0201-positive individuals, based on their structural and functional attributes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The blood pressure, heart rate and humoral responses to single intravenous doses of the angiotensin converting enzyme inhibitor captopril were evaluated in 5 volunteers on a free salt intake. Each subject was given at one-week intervals a 1, 5 and 25 mg intravenous dose of captopril as well as the vehicle of captopril. The study was conducted in a single-blind fashion and the order of treatment phases was randomized. Captopril was found to inhibit the renin-angiotensin system in a dose-dependent fashion. A fall in circulating angiotensin II was observed with doses of 1 and 5 mg. Plasma angiotensin II was not detectable 15 min after the 25 mg dose. Acute inhibition of angiotensin converting enzyme with intravenous captopril had no effect on blood pressure and heart rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To evaluate the effect of a structured preoperative preparation on child and parent state anxiety, child behavioural change and parent satisfaction. BACKGROUND: It is estimated that around 50-70% of hospitalised children experience severe anxiety and distress prior to surgery. Children who are highly anxious and distressed preoperatively are likely to be distressed on awakening and have negative postoperative behaviour. Although education before surgery has been found to be useful mostly in North America, the effectiveness of preoperative preparation programme adapted to the Australian context remains to be tested. DESIGN: This single-blind randomised controlled study was conducted at a tertiary referral hospital for children in Western Australia. METHODS: Following ethics approval and parental consent, 73 children and one of their carers (usually a parent) were randomly assigned into two groups. The control group had standard practice with no specific preoperative education and the experimental group received a preoperative preparation, including a photo file, demonstration of equipment using a role-modelling approach and a tour. RESULTS: The preoperative preparation reduced parent state anxiety significantly (-2·32, CI -4·06 to -0·56, p = 0·009), but not child anxiety (-0·59, CI -1·23 to 0·06, p = 0·07). There was no significant difference in child postoperative behaviour or parent satisfaction between the groups. There was a significant two-point pain score reduction in the preoperative preparation group, when compared with the control group median 2 (IQR 5) and 4 (IQR 4), respectively (p = 0·001).¦CONCLUSIONS: Preoperative preparation was more efficient on parent than child. Although the preoperative preparation had limited effect on child anxiety, it permitted to decrease pain experience in the postoperative period.¦RELEVANCE TO CLINICAL PRACTICE: Parents should be actively involved in their child preoperative preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exact formulas for the effective eigenvalue characterizing the initial decay of intensity correlation functions are given in terms of stationary moments of the intensity. Spontaneous emission noise and nonwhite pump noise are considered. Our results are discussed in connection with earlier calculations, simulations, and experimental results for single-mode dye lasers, two-mode inhomogeneously broadened lasers, and two-mode dye ring lasers. The effective eigenvalue is seen to depend sensitively on noise characteristics and symmetry properties of the system. In particular, the effective eigenvalue associated with cross correlations of two-mode lasers is seen to vanish in the absence of pump noise as a consequence of detailed balance. In the presence of pump noise, the vanishing of this eigenvalue requires equal pump parameters for the two modes and statistical independence of spontaneous emission noise acting on each mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent measurements of electron escape from a nonequilibrium charged quantum dot are interpreted within a two-dimensional (2D) separable model. The confining potential is derived from 3D self-consistent Poisson-Thomas-Fermi calculations. It is found that the sequence of decay lifetimes provides a sensitive test of the confining potential and its dependence on electron occupation