990 resultados para Red edge emission
Resumo:
Performance standards for Positron emission tomography (PET) were developed to be able to compare systems from different generations and manufacturers. This resulted in the NEMA methodology in North America and the IEC in Europe. In practices, the NEMA NU 2- 2001 is the method of choice today. These standardized methods allow assessment of the physical performance of new commercial dedicated PET/CT tomographs. The point spread in image formation is one of the factors that blur the image. The phenomenon is often called the partial volume effect. Several methods for correcting for partial volume are under research but no real agreement exists on how to solve it. The influence of the effect varies in different clinical settings and it is likely that new methods are needed to solve this problem. Most of the clinical PET work is done in the field of oncology. The whole body PET combined with a CT is the standard investigation today in oncology. Despite the progress in PET imaging technique visualization, especially quantification of small lesions is a challenge. In addition to partial volume, the movement of the object is a significant source of error. The main causes of movement are respiratory and cardiac motions. Most of the new commercial scanners are in addition to cardiac gating, also capable of respiratory gating and this technique has been used in patients with cancer of the thoracic region and patients being studied for the planning of radiation therapy. For routine cardiac applications such as assessment of viability and perfusion only cardiac gating has been used. However, the new targets such as plaque or molecular imaging of new therapies require better control of the cardiac motion also caused by respiratory motion. To overcome these problems in cardiac work, a dual gating approach has been proposed. In this study we investigated the physical performance of a new whole body PET/CT scanner with NEMA standard, compared methods for partial volume correction in PET studies of the brain and developed and tested a new robust method for dual cardiac-respiratory gated PET with phantom, animal and human data. Results from performance measurements showed the feasibility of the new scanner design in 2D and 3D whole body studies. Partial volume was corrected, but there is no best method among those tested as the correction also depends on the radiotracer and its distribution. New methods need to be developed for proper correction. The dual gating algorithm generated is shown to handle dual-gated data, preserving quantification and clearly eliminating the majority of contraction and respiration movement
Resumo:
Objective: The aim of this study was to investigate the use of sentinel lymph node biopsy (SLNB) and whole body positron emission tomography (PET), with emphasis on surgical treatment and prognosis, in the detection of clinically occult metastases in patients with clinically localized cutaneous melanoma. Patients and methods: The study population consisted of 1255 patients with clinical stage I–II cutaneous melanoma, operated at Turku University Hospital between 1983 and 2007. 334 patients underwent SLNB and they were compared to 921 retrospective patients. A subgroup of 30 symptom-free patients with high risk melanoma underwent prospectively whole body PET 6–24 months postoperatively. Results: Overall, the disease-specific survival rate was 84.4 % at five years. Sex, Breslow thickness, age and nodal status were independent prognostic factors for survival. SLNB revealed occult nodal metastases in 17 % of the patients. There was no significant difference in disease-specific overall survival between SLNB patients and controls, but the nodal disease-free time was significantly longer suggesting better local control after SLNB and subsequent completion lymph node dissection. The followup time was different between the study cohorts and initial surgery was performed during different time periods. SLNB detected micrometastases in seven of 155 patients (4.5 %) with thin T1 primary melanoma and in four of 25 patients (16 %) with head and neck melanoma. In six of 30 asymptomatic patients with high risk melanoma (20 %), whole body PET detected occult distant metastases. Conclusion: Both SLNB and whole body PET were reliable methods to detect clinically occult metastases in patients with cutaneous melanoma. This upstaging altered the treatment in each case.
Resumo:
El proyecto "RPS: Red social para entusiastas de Raspberry Pi", se desarrollará en el ámbito temático de desarrollo de aplicaciones móviles con HTML5. La idea principal de este proyecto se centra en dar visibilidad a la comunidad de Raspberry Pi, mediante una aplicación móvil destinada a compartir las experiencias de sus usuarios de una forma sencilla y atractiva.
Resumo:
El éxito del comercio electrónico, el manejo de nuevas plataformas para llevar a cabo campañas de marketing online, la aparición de influenciadores como los blogs y las redes sociales o los nuevos formatos de publicidad de moda en la red son algunos de los puntos que se analizarán en esta disertación.
Resumo:
A physical model for the simulation of x-ray emission spectra from samples irradiated with kilovolt electron beams is proposed. Inner shell ionization by electron impact is described by means of total cross sections evaluated from an optical-data model. A double differential cross section is proposed for bremsstrahlung emission, which reproduces the radiative stopping powers derived from the partial wave calculations of Kissel, Quarles and Pratt [At. Data Nucl. Data Tables 28, 381 (1983)]. These ionization and radiative cross sections have been introduced into a general-purpose Monte Carlo code, which performs simulation of coupled electron and photon transport for arbitrary materials. To improve the efficiency of the simulation, interaction forcing, a variance reduction technique, has been applied for both ionizing collisions and radiative events. The reliability of simulated x-ray spectra is analyzed by comparing simulation results with electron probe measurements.
Resumo:
Eu3+ luminescence and EXAFS (Extended X-ray Absorption Fine Structure) results are presented for organic-inorganic hybrid gel hosts composed of a siliceous network to which small chains of oxyethylene units are covalently grafted by means of urea bridges. Coordination numbers for Eu3+ ions range from 12.8 to 9.7 with increasing Eu3+ concentration while the Eu3+-first neighbours mean distance is found to be constant at 2.48-2.49 Å in the same concentration range. Emission spectra display a broad band in the green/blue spectral region superposed to narrow lines appearing in the yellow/red region in such a way that for the eyes emission appears white. The broad band is assigned to intrinsic NH groups emission and also to electron-hole recombination in the nanosised siliceous domains. The narrow lines are assigned to intra-4f6, 5D0->7F0-4 Eu3+ transitions and from the energy position of the 7F0-4 levels a mean distance could be calculated for the Eu3+-first neighbours. The calculated results are in good agreement with the experimental ones obtained from EXAFS analysis.
Resumo:
Presentación de los barrios de blogs: cómo son, cómo se relacionan, cómo se propaga la información a través de éstos y cómo saber cuáles son los más interesantes.
Resumo:
Ultra-trace amounts of Cu(II) were separated and preconcentrated by solid phase extraction on octadecyl-bonded silica membrane disks modified with a new Schiff,s base (Bis- (2-Hydroxyacetophenone) -2,2-dimethyl-1,3-propanediimine) (SBTD) followed by elution and inductively coupled plasma atomic emission spectrometric detection. The method was applied as a separation and detection method for copper(II) in environmental and biological samples. Extraction efficiency and the influence of sample matrix, flow rate, pH, and type and minimum amount of stripping acid were investigated. The concentration factor and detection limit of the proposed method are 500 and 12.5 pg mL-1, respectively.
Resumo:
En els últims anys la comunicació ha evolucionat a causa de la digitalització de la societat i l'aparició de múltiples plataformes socials. Per això, aquesta investigació busca analitzar com ha canviat l'entorn comunicatiu, fins a quins nivells ha afectat això a les marques i als consumidors prenent com a punt central d'aquest projecte la transmedialitat, les seves característiques i les seves funcions. A més, analitzarem tots aquests canvis aplicant els coneixements teòrics a la campanya Red Bull Stratos, que per a molts va marcar un abans i un després en la història del màrqueting de continguts.
Resumo:
Emission trading with greenhouse gases and green certificates are part if the climate policy the main target of which is reduce greenhouse gas emissions. The carbon dioxide and fine particle emissions of energy production in Helsinki Metropolitan area are calculated in this study. The analysis is made mainly by district heating point of view and the changes of the district heating network are assessed. Carbon dioxide emissions would be a bit higher, if the district heating network is expanded, but then the fine particle emissions would be much lower. Carbon dioxide emissions are roughly 10 % higher, if the district heating network is expanded at same rate as it has in past five years in the year 2030. The expansion of district heating network would decrease the fine particle emissions about 40 %. The cost of the expansion is allocated to be reduction cost of the fine particle emissions, which is considerably higher than the traditional reduction methods costs. The possible new nuclear plant would reduce the emissions considerably and the costs of the nuclear plant would be relatively low comparing the other energy production methods.
Resumo:
Context. The interaction of microquasar jets with their environment can produce non-thermal radiation as in the case of extragalactic outflows impacting on their surroundings. Significant observational evidence of jet/medium interaction in galactic microquasars has been collected in the past few years, although little theoretical work has been done regarding the resulting non-thermal emission. Aims. In this work, we investigate the non-thermal emission produced in the interaction between microquasar jets and their environment, and the physical conditions for its production. Methods. We developed an analytical model based on those successfully applied to extragalactic sources. The jet is taken to be a supersonic and mildly relativistic hydrodynamical outflow. We focus on the jet/shocked medium structure in its adiabatic phase, and assume that it grows in a self-similar way. We calculate the fluxes and spectra of the radiation produced via synchrotron, inverse Compton, and relativistic bremsstrahlung processes by electrons accelerated in strong shocks. A hydrodynamical simulation is also performed to investigate further the jet interaction with the environment and check the physical parameters used in the analytical model. Results. For reasonable values of the magnetic field, and using typical values of the external matter density, the non-thermal particles could produce significant amounts of radiation at different wavelengths, although they do not cool primarily radiatively, but by adiabatic losses. The physical conditions of the analytical jet/medium interaction model are consistent with those found in the hydrodynamical simulation. Conclusions. Microquasar jet termination regions could be detectable at radio wavelengths for current instruments sensitive to ~arcminute scales. At X-ray energies, the expected luminosities are moderate, although the emitter is more compact than the radio one. The source may be detectable by XMM-Newton or Chandra, with 1-10 arcsec of angular resolution. The radiation at gamma-ray energies may be within the detection limits of the next generation of satellite and ground-based instruments.
Resumo:
We present new optical and infrared photometric observations and high resolution H α spectra of the periodic radio star LSI+61◦303. The optical photometric data set covers the time interval 1985-1993 and amounts to about a hundred nights. A period of ∼26 days is found in the V band. The infrared data also present evidence for a similar periodicity, but with higher amplitude of variation ((0.m 2). The spectroscopic observations include 16 intermediate and high dispersion spectra of LSI+61◦303 collected between January 1989 and February 1993. The H α emission line profile and its variations are analyzed. Several emission line parameters -- among them the H α EW and the width of the H α red hump -- change strongly at or close to radio maximum, and may exhibit periodic variability. We also observe a significant change in the peak separation. The H α profile of LSI+61◦303 does not seem peculiar for a Be star. However, several of the observed variations of the H α profile can probably be associated with the presence of the compact, secondary star.
Resumo:
Chromium(III) at the ng L-1 level was extracted using partially silylated MCM-41 modified by a tetraazamacrocyclic compound (TAMC) and determined by inductively coupled plasma optical emision spectrometry (ICP OES). The extraction time and efficiency, pH and flow rate, type and minimum amount of stripping acid, and break- through volume were investigated. The method's enrichment factor and detection limit are 300 and 45.5 pg mL-1, respectively. The maximum capacity of the 10 mg of modified silylated MCM-41 was found to be 400.5±4.7 µg for Cr(III). The method was applied to the determination of Cr(III) and Cr(VI) in the wastewater of the chromium electroplating industry and in environmental and biological samples (black tea, hot and black pepper).
Resumo:
Tutkimuksen tausta ja tavoitteet: Viimeaikaisesta perinteisten kuvantamismenetelmien kehityksestä huolimatta sekä haima- että neuroendokriinisten (NE) kasvaimien diagnostiikka on haastavaa. Uudentyyppinen kuvantamismenetelmä, fuusio positroniemissiotomografia-tietokonetomografia (PET/TT), on lupaava näiden kasvainten erotusdiagnostiikassa ja levinneisyyden arvioinnissa. Huolimatta alustavista lupaavista tutkimustuloksista, PET/TT:n rooli on toistaiseksi vielä epäselvä sekä haima- että NE-kasvaimissa eikä se näin ollen ole vakiintunut kliiniseen hoitokäytäntöön. Väitöskirjatyön tavoitteena oli selvittää PET/TT -menetelmän käyttökelpoisuutta haima- ja NE-kasvaimien diagnostiikassa. Kahden ensimmäisen osatyön prospektiivisessa tutkimuksessa potilaat, joilla epäiltiin haimakasvainta, kuvannettiin PET/TT:llä käyttäen merkkiaineena fluorideoxyglukoosia (18F-FDG) kasvaimen aineenvaihdunnan arvioimiseksi ja kasvaimen verenvirtausta arviointiin käyttäen merkkiaineena radiovettä (15O-H2O). Kolmen muun osatyön tavoitteena oli selvittää dihydroxyfenylalaniini (18F-DOPA) PET -menetelmää erilaisten NE-kasvaimien diagnostiikassa ja levinneisyyden arvioinnissa. Tulokset: Haimakasvaimien ensivaiheen diagnostiikassa 18F-FDG-PET/TT:llä oli korkeampi diagnostinen tarkkuus verrattuna titokoneleike- (TT) ja magneettikuvantamiseen (MK) (89% vs. 76% ja 79%). Etenkin pahanlaatuiseksi epäillyn sappitiehytahtauman erotusdiagnostiikassa 18F-FDG-PET/TT:n positiivinen ennustearvo (92%) oli korkea. Haimasyövän levinneisyyden arvioinnissa 18F-FDG-PET/TT:n herkkyys oli huono (30%) paikallisen taudin osoittamisessa. Sen sijaan etäpesäkkeiden osoittamisessa 18F-FDG-PET/TT oli merkittävästi herkempi menetelmä verrattuna TT ja magneettikuvantamiseen (88% vs. 38%). Verrattaessa erilaisten haimakasvaimien ja normaalin haimakudoksen aineenvaihduntaa ja verenvirtausta, aineenvaihdunta/verenvirtaus suhde oli merkittävästi korkeampi pahanlaatuisissa haimakasvaimissa (P<0.05). Lisäksi kasvaimen korkea aineenvaihdunta/verenvirtaus suhde viittasi huonompaan taudin ennusteeseen. 18F-DOPA-PET löysi seitsemän kahdeksasta insulinoomasta ja oli positiivinen myös kahdella potilaalla, joilla todettiin haiman saarakesoluhyperplasia. Perustuen alustaviin tuloksiin, rutiinikäytössä oleva karbidopa esilääke ennen 18F-DOPA-PET kuvantamista peitti insulinooma löydöksen kahdella potilaalla kolmesta. NE-kasvaiminen diagnostiikassa 82 potilaan aineisto osoitti 18F-DOPA PET kuvantamisen tarkkuudeksi 90%. Etenkin feokromosytoomien ensivaiheen diagnostiikassa ja NE-kasvaimen uusiutumaa epäiltäessä menetelmän tarkkuus oli korkea. Kokonaisuudessaan 59%:lla aineiston potilaista 18F-DOPA-PET kuvantamisella oli vaikutusta kliinisiin hoitoratkaisuihin. Johtopäätökset: PET/TT käyttäen merkkiaineena 18F-FDG:tä ja radiovettä osoittautui käyttökelpoiseksi menetelmäksi haimakasvaimien erotusdiagnostiikassa. Lisäksi 18F-FDG-PET/TT oli hyödyllinen haimasyövän etäpesäkkeiden arvioinnissa. Tutkimus osoitti myös 18F-DOPA-PET kuvantamisen olevan luotettava menetelmä insulinoomien ja muiden vatsan alueen NE-kasvaimien ensivaiheen diagnostiikassa sekä levinneisyyden arvioinnissa, etenkin muiden kuvantamislöydösten ollessa ristiriitaisia. PET kuvantamisella oli merkittävä vaikutus potilaiden kliiniseen hoitokäytäntöön sekä haima- että NE-kasvaimissa.
Resumo:
El cuento de Caperucita Roja1 ha sobrevivido a través de los años gracias a su rico simbolismo por las imágenes de gran alcance que contiene. La joven niña con la capa roja que se encuentra con un lobo disfrazado de abuela es algo que golpea profundamente al receptor. El tema se ha estudiado desde numerosos puntos de vista; destaca el psicoanalista Bruno Bettelheim,2 que señala la caperuza que lleva la protagonista como símbolo de su entrada en la pubertad, asociando el color rojo con el ciclo menstrual. No todos los críticos están de acuerdo con este aspecto, aunque bastantes autores relacionan el cuento con el despertar de la sexualidad,la adolescencia y todo lo que conlleva. Perrault tampoco descuida tener en cuenta su advertencia de los riesgos en la etapa, sobre todo para las niñas románticas, en la moraleja final del relato.