998 resultados para Radiology technicians


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The first aim of this study was to assess the diagnostic performance of presepsin (sCD14-ST) in postmortem serum from femoral blood compared to procalcitonin (PCT) to detect sepsis-related fatalities. The second aim was to compare sCD14-ST levels found in postmortem serum to the values in pericardial fluid to investigate the usefulness of the latter as an alternative biological fluid. Two study groups were formed, a sepsis-related fatalities group and a control group. Radiology (unenhanced CT scans and postmortem angiographies), autopsies, histology, neuropathology, and toxicology as well as other postmortem biochemistry investigations were performed in all cases. Microbiological investigations on right cardiac blood were carried out exclusively in septic cases. The results of this study indicated that postmortem serum PCT and sCD14-ST levels, individually considered, allowed septic cases to be identified. Even though increases in both PCT and sCD14-ST concentrations were observed in the control cases, coherent PCT and sCD14-ST results in cases with suspected sepsis allowed the diagnosis to be confirmed. Conversely, no relevant correlation was identified between postmortem serum and pericardial fluid sCD14-ST levels in either the septic or control groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Late treatment of invasive candidiasis (IC) results in severe complications and high mortality. New tools are needed for early diagnosis. We conducted a retrospective study to assess the diagnostic utility of mannan antigenemia (Mn) and antimannan antibodies (anti-Mn) in neutropenic cancer patients at high risk for candidiasis. Twenty-eight patients with IC (based on European Organization for Research and Treatment of Cancer and Mycoses Study Group definitions) and 25 controls were studied. Mn and anti-Mn were positive (> or = 0.25 ng/mL and > or = 5 AU/mL, respectively) in 25/28 (89%) patients with candidiasis and in 4/25 (16%) controls: sensitivity, 89%; specificity, 84%; positive predictive value, 86%; negative predictive value, 88%. In patients with hepatosplenic lesions, assessing Mn/anti-Mn shortened the median time of diagnosis of candidiasis when compared with imaging (9 versus 25 days after fever onset as first sign of infection; P < 0.001). Candidiasis was diagnosed before neutrophil recovery in 78% and 11% of cases with Mn/anti-Mn and radiology, respectively (P < 0.001). Mn and anti-Mn may be useful for early noninvasive diagnosis of IC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quality assurance programmes are becoming a common practice in the field of mammography. At the present time several recommendations exist and different test objects are used to optimize this radiological procedure. The goal of this study was to check if geographically distant centres using different quality control procedures were comparable when using a common objective way of assessing image quality. The results show that consensus still needs to be found among radiologists to reach a satisfactory level of harmony between patient doses and image quality in Europe.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Retrograde or combined retrograde and antegrade recanalization should be considered when antegrade recanalization has failed in selected patients with critical limb ischemia (CLI). Retrograde recanalization is typically attempted through a patent segment of the popliteal artery or an infrapopliteal artery. The challenge arises, however, when there are no patent popliteal or infrapopliteal arteries suitable for retrograde access.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To describe the safety, complications, and liver regeneration associated with the left liver after embolization of the right portal vein (PV) in patients with hepatocellular carcinoma (HCC) developed in the setting of advanced liver fibrosis and cirrhosis. MATERIALS AND METHODS: Forty patients (31 men, nine women; mean age, 62 years) with HCC underwent PV embolization over a 4-year period. Embolization was performed from a left PV percutaneous access with use of n-butyl cyanoacrylate (NBCA) mixed with iodized oil. Computed tomography (CT) volumetry was performed before and 1 month after PV embolization to measure the left lobe volume as well as the functional liver ratio defined by the ratio between the left lobe and the total liver volume minus tumoral volume. PV pressure and liver enzyme levels were compared before and 1 month after the procedure and complications were registered. Factors potentially affecting regeneration (age, sex, diabetes, chemoembolization, functional liver ratio before PV embolization, and Knodell histologic score) were evaluated by one-way and stepwise regression analysis. RESULTS: PV embolization could be achieved successfully in all cases. Two patients had partial PV thrombosis on the 1-month follow-up CT and two patients developed transient ascites after PV embolization. The left lobe volume increase was 41% +/- 32% after PV embolization and the functional liver ratio increased from 28% +/- 10% to 36% +/- 10% (P < .0001). Hypertrophy of the left lobe was greater in patients with a low functional liver ratio before PV embolization and those with an F3 fibrosis score. Other factors had no influence on left lobe regeneration. CONCLUSION: PV embolization with use of NBCA is feasible in patients with advanced fibrosis and cirrhosis. Hypertrophy of the left lobe of the liver after PV embolization has a statistically significant correlation with lower functional liver ratio and lower degrees of fibrosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Retained T-tubes are rare complications after biliary surgery. The authors present three cases of retained T-tubes in patients with transplanted liver that could not be removed by a standard manual traction. The authors describe a new simple percutaneous method that allows removal of these T-tubes without complication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our objective was to establish the age-related 3D size of maxillary, sphenoid, and frontal sinuses. A total of 179 magnetic resonance imaging (MRI) of children under 17 years (76 females, 103 males) were included and sinuses were measured in the three axes. Maxillary sinuses measured at birth (mean+/-standard deviation) 7.3+/-2.7 mm length (or antero-posterior)/4.0+/-0.9 mm height (or cranio-caudal)/2.7+/-0.8 mm width (or transverse). At 16 years old, maxillary sinus measured 38.8+/-3.5 mm/36.3+/-6.2 mm/27.5+/-4.2 mm. Sphenoid sinus pneumatization starts in the third year of life after conversion from red to fatty marrow with mean values of 5.8+/-1.4 mm/8.0+/-2.3 mm/5.8+/-1.0 mm. Pneumatization progresses gradually to reach at 16 years 23.0+/-4.5 mm/22.6+/-5.8 mm/12.8+/-3.1 mm. Frontal sinuses present a wide variation in size and most of the time are not valuable with routine head MRI techniques. They are not aerated before the age of 6 years. Frontal sinuses dimensions at 16 years were 12.8+/-5.0 mm/21.9+/-8.4 mm/24.5+/-13.3 mm. A sinus volume index (SVI) of maxillary and sphenoid sinus was computed using a simplified ellipsoid volume formula, and a table with SVI according to age with percentile variations is proposed for easy clinical application. Percentile curves of maxillary and sphenoid sinuses are presented to provide a basis for objective determination of sinus size and volume during development. These data are applicable to other techniques such as conventional X-ray and CT scan.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the diagnostic value and image quality of CT with filtered back projection (FBP) compared with adaptive statistical iterative reconstructed images (ASIR) in body stuffers with ingested cocaine-filled packets.Methods and Materials: Twenty-nine body stuffers (mean age 31.9 years, 3 women) suspected for ingestion of cocaine-filled packets underwent routine-dose 64-row multidetector CT with FBP (120kV, pitch 1.375, 100-300 mA and automatic tube current modulation (auto mA), rotation time 0.7sec, collimation 2.5mm), secondarily reconstructed with 30 % and 60 % ASIR. In 13 (44.83%) out of the body stuffers cocaine-filled packets were detected, confirmed by exact analysis of the faecal content including verification of the number (range 1-25). Three radiologists independently and blindly evaluated anonymous CT examinations (29 FBP-CT and 68 ASIR-CT) for the presence and number of cocaine-filled packets indicating observers' confidence, and graded them for diagnostic quality, image noise, and sharpness. Sensitivity, specificity, area under the receiver operating curve (ROC) Az and interobserver agreement between the 3 radiologists for FBP-CT and ASIR-CT were calculated.Results: The increase of the percentage of ASIR significantly diminished the objective image noise (p<0.001). Overall sensitivity and specificity for the detection of the cocaine-filled packets were 87.72% and 76.15%, respectively. The difference of ROC area Az between the different reconstruction techniques was significant (p= 0.0101), that is 0.938 for FBP-CT, 0.916 for 30 % ASIR-CT, and 0.894 for 60 % ASIR-CT.Conclusion: Despite the evident image noise reduction obtained by ASIR, the diagnostic value for detecting cocaine-filled packets decreases, depending on the applied ASIR percentage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine the impact of the learning curve on the diagnostic performances of CT colonography. Two blinded teams, each having a radiologist and gastroenterologist, prospectively examined 50 patients using helical CT scan followed by colonoscopy. Intermediate data evaluation was performed after 24 data sets (group 1) and compared with data from 26 subsequent patients (group 2). Parameters evaluated included sensitivity, specificity, false-positive and false-negative findings, time of data acquisition and interpretation. Using colonoscopy as the gold standard, sensitivity for CT colonography was for lesions >5 mm 63% for both teams for group 1 patients; for group 2 patients sensitivity was 45% for team 1 and 64% for team 2. Specificity per patients was for patient group 1 42% for team 1 and 58% for team 2; for patient group 2 it was 79% for both teams ( p=0.04 for team 1; p=0.2 for team 2). Comparing group 1 with group 2, the number of false-positive findings decreased significantly ( p=0.02). Furthermore, the mean time of data evaluation decreased from 45 to 17 min ( p=0.002) and the mean time of data acquisition from 19 to 17 min. With increasing experience, specificity and the time required for data interpretation improved and false positives decreased. There was no significant change of sensitivity, false-negative findings and time of data acquisition. A minimum experience of the readers is required for data interpretation of CT colonography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the diagnostic performance of respiratory self-navigation for whole-heart coronary magnetic resonance (MR) angiography in a patient cohort referred for diagnostic cardiac MR imaging. MATERIALS AND METHODS: Written informed consent was obtained from all participants for this institutional review board-approved study. Self-navigated coronary MR angiography was performed after administration of a contrast agent in 78 patients (mean age, 48.5 years ± 20.7 [standard deviation]; 53 male patients) referred for cardiac MR imaging because of coronary artery disease (n = 40), cardiomyopathy (n = 14), congenital anomaly (n = 17), or "other" (n = 7). Examination duration was recorded, and the image quality for each coronary segment was assessed with consensus reading. Vessel sharpness, length, and diameter were measured. Quantitative values in proximal, middle, and distal segments were compared by using analysis of variance and t tests. A double-blinded comparison with the results of x-ray angiography was performed when such results were available. RESULTS: When patients with different indications for cardiac MR imaging were examined with self-navigated postcontrast coronary MR angiography, whole-heart data sets with 1.15-mm isotropic spatial resolution were acquired in an average of 7.38 minutes ± 1.85. The main and proximal coronary segments could be visualized in 92.3% of cases, while the middle and distal segments could be visualized in 84.0% and 55.8% of cases, respectively. Subjective scores and vessel sharpness were significantly higher in the proximal segments than in the middle and distal segments (P < .05). Anomalies of the coronary arteries could be confirmed or excluded in all cases. Per-vessel sensitivity and specificity for stenosis detection were 64.7% and 85.0%, respectively, in the 31 patients for whom reference standard x-ray coronary angiography results were available. CONCLUSION: The self-navigated coronary MR angiography sequence shows promise for coronary imaging. However, technical improvements are needed to improve image quality, especially in the more distal coronary segments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the diagnostic value of previously described MR features used for detecting suspected placental invasion according to observers' experience. MATERIALS AND METHODS: Our population included 25 pregnant women (mean age 35.16) investigated by prenatal MRI (1.5T, T1- and T2-weighted MR-sequences without i.v. contrast), among them 12 with histopathologically proven placental invasion and 13 women (52%) without placental invasion used as control group. Two senior and two junior radiologists blindly and independently reviewed MR-examinations in view of 6 previously defined MR-features indicating presence and degree of placental invasion (placenta increta, accreta or percreta). For each reader the sensibility, specificity, and receiver operating curve (ROC) were calculated. Interobserver agreements between senior and junior readers were determined. Stepwise logistic regression was performed including the 6 MR-features predictive of placental invasion. RESULTS: Demographics between both groups were statistically equivalent. Overall sensitivity and specificity for placental invasion was 90.9% and 75.0% for seniors and 81.8% and 61.8% for juniors, respectively. The best single MR-feature indicating placental invasion was T2-hypointense placental bands (r(2)=0.28), followed by focally interrupted myometrial border, infiltration of pelvic organs and tenting of the bladder (r(2)=0.36). Interobserver agreement for detecting placental invasion was 0.64 for seniors and 0.41 for juniors, thus substantial and moderate, respectively. Seniors detected placental invasion and depth of infiltration with significantly higher diagnostic certitude than juniors (p=0.0002 and p=0.0282, respectively). CONCLUSION: MRI can be a reliable and reproducible tool for the detection of suspected placental invasion, but the diagnostic value significantly depends on observers' experience.