977 resultados para Radiation Oncology


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accepted paradigm for radiation effects is that direct DNA damage via energy deposition is required to trigger the downstream biological consequences. The radiation-induced bystander effect is the ability of directly irradiated cells to interact with their nonirradiated neighbors, which can then show responses similar to those of the targeted cells. p53 binding protein 1 (53BP1) forms foci at DNA double-strand break sites and is an important sensor of DNA damage. This study used an ionizing radiation microbeam approach that allowed us to irradiate specifically the nucleus or cytoplasm of a cell and quantify response in irradiated and bystander cells by studying ionizing radiation-induced foci (IRIF) formation of 53BP1 protein. Our results show that targeting only the cytoplasm of a cell is capable of eliciting 53BP1 foci in both hit and bystander cells, independently of the dose or the number of cells targeted. Therefore, direct DNA damage is not required to trigger 53BP1 IRIF. The use of common reactive oxygen species and reactive nitrogen species (RNS) inhibitors prevent the formation of 53BP1 foci in hit and bystander cells. Treatment with filipin to disrupt membrane-dependent signaling does not prevent the cytoplasmic irradiation-induced 53BP1 foci in the irradiated cells, but it does prevent signaling to bystander cells. Active mitochondrial function is required for these responses because pseudo-rho(0) cells, which lack mitochondrial DNA, could not produce a bystander signal, although they could respond to a signal from normal rho(+) cells.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution.Materials and methods: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stem, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated.Results: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170o from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation.Conclusions: For patients with parotid gland tumours, reduction in the radiation dose to critical normal tissues was demonstrated with 3DCRT compared with conventional RT. IMRT produced a further reduction in the dose to the cochlea and oral cavity. With nine and seven fields, the dose to the contra-lateral parotid gland was increased, but this was avoided by optimisation of the beam directions. The benefits of IMRT were maintained with three or four fields when the beam angles were optimised, but were also achieved using a four-field class solution. Clinical trials are required to confirm the clinical benefits of these improved dose distributions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Driving high-level transgene expression in a tumour-specific manner remains a key requirement in the development of cancer gene therapy. We have previously demonstrated the strong anticancer effects of generating abnormally high levels of intracellular NO• following the overexpression of the inducible nitric oxide synthase (iNOS) gene. Much of this work has focused on utilizing exogenously activated promoters, which have been primarily induced using X-ray radiation. Here we further examine the potential of the pE9 promoter, comprising a combination of nine CArG radio-responsive elements, to drive the iNOS transgene. Effects of X-ray irradiation on promoter activity were compared in vitro under normoxic conditions and various degrees of hypoxia. The pE9 promoter generated high-level transgene expression, comparable with that achieved using the constitutively driven cytomegalovirus promoter. Furthermore, the radio-resistance of radiation-induced fibrosarcoma-1 (RIF-1) mouse sarcoma cells exposed to 0.1 and 0.01% O2 was effectively eliminated following transfection with the pE9/iNOS construct. Significant inhibition of tumour growth was also observed in vivo following direct intratumoural injection of the pE9/iNOS construct compared to empty vector alone (P<0.001) or to a single radiation dose of 10?Gy (P<0.01). The combination of both therapies resulted in a significant 4.25 day growth delay compared to the gene therapy treatment alone (P<0.001). In summary, we have demonstrated the potential of the pE9/iNOS construct for reducing radio-resistance conferred by tumour cell hypoxia in vitro and in vivo, with greater tumour growth delay observed following the treatment with the gene therapy construct as compared with radiotherapy alone.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some critical avionic systems require cooling air via vents on the side of the aircraft, thus creating leakage points for high-intensity electromagnetic radiation. This paper presents a novel application of high-intensity radiated field (HIRF) shielding using a rectangular waveguide array, while maintaining cooling airflow requirements. Signal attenuation versus frequency and depth of the array has been calculated using closed-form equations. The simulation and measurement results are in good agreement with the calculated values. (C) 2004 Wiley Periodicals, Inc.