953 resultados para RADIO-FREQUENCY ABLATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In more scientific terms, NET Station contributed to: - discuss in theoretical terms the role radio still play in contemporary societies; - examine how audiences are using sound resources on the Web; - draw up a new theoretical framework for the study of the reconfiguration of radio language on the Internet;acknowledge that people are not abandoning radio as a medium; the survey applied by the team demonstrated that there is a complementariness between traditional radio and radio on the Internet; - understand that people expect more interactivity, more opportunities to participate in content production and more diversity of contents. These results were shared with editors responsible for Portuguese radio and might influence the offer made available by these radio corporations from now on; - demonstrate that the Internet is underexplored in terms of sound and acoustic communication; - promote the production of new sound narratives to be available on the Internet;

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To demonstrate the feasibility and safety of simultaneous catheterization and mapping of the 4 pulmonary veins for ablation of atrial fibrillation. METHODS: Ten patients, 8 with paroxysmal atrial fibrillation and 2 with persistent atrial fibrillation, refractory to at least 2 antiarrhythmic drugs and without structural cardiopathy, were consecutively studied. Through the transseptal insertion of 2 long sheaths, 4 pulmonary veins were simultaneously catheterized with octapolar microcatheters. After identification of arrhythmogenic foci radiofrequency was applied under angiographic or ultrasonographic control. RESULTS: During 17 procedures, 40 pulmonary veins were mapped, 16 of which had local ectopic activity, related or not with the triggering of atrial fibrillation paroxysms. At the end of each procedure, suppression of arrhythmias was obtained in 8 patients, and elimination of pulmonary vein potentials was accomplished in 4. During the clinical follow-up of 9.6±3 months, 7 patients remained in sinus rhythm, 5 of whom were using antiarrhythmic drugs that had previously been ineffective. None of the patients had pulmonary hypertension or evidence of stenosis in the pulmonary veins. CONCLUSION: Selective and simultaneous catheterization of the 4 pulmonary veins with microcatheters for simultaneous recording of their electrical activity is a feasible and safe procedure that may help ablation of atrial fibrillation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Using P-wave signal-averaged electrocardiography, we assessed the patterns of atrial electrical activation in patients with idiopathic atrial fibrillation as compared with patterns in patients with atrial fibrillation associated with structural heart disease. METHODS: Eighty patients with recurrent paroxysmal atrial fibrillation were divided into 3 groups as follows: group I - 40 patients with atrial fibrillation associated with non-rheumatic heart disease; group II - 25 patients with rheumatic atrial fibrillation; and group III - 15 patients with idiopathic atrial fibrillation. All patients underwent P-wave signal-averaged electrocardiography for frequency-domain analysis using spectrotemporal mapping and statistical techniques for detecting and quantifying intraatrial conduction disturbances. RESULTS: We observed an important fragmentation in atrial electrical conduction in 27% of the patients in group I, 64% of the patients in group II, and 67% of the patients in group III (p=0.003). CONCLUSION: Idiopathic atrial fibrillation has important intraatrial conduction disturbances. These alterations are similar to those observed in individuals with rheumatic atrial fibrillation, suggesting the existence of some degree of structural involvement of the atrial myocardium that cannot be detected with conventional electrocardiography and echocardiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify useful clinical characteristics for selecting patients eligible for mapping and ablation of atrial fibrillation. METHODS: We studied 9 patients with atrial fibrillation, without structural heart disease, associated with: 1) antiarrhythmic drugs, 2) symptoms of low cardiac output, and 3) intention to treat. Seven patients had paroxysmal atrial fibrillation and 2 had recurrent atrial fibrillation. RESULTS: In the 6 patients who underwent mapping (all had paroxysmal atrial fibrillation), catheter ablation was successfully carried out in superior pulmonary veins in 5 patients (the first 3 in the left superior pulmonary vein and the last 2 in the right superior pulmonary vein). One patient experienced a recurrence of atrial fibrillation after 10 days. We observed that patients who had short episodes of atrial fibrillation on 24-hour Holter monitoring before the procedure were those in whom mapping the focus of tachycardia was possible. Tachycardia was successfully suppressed in 4 of 6 patients. The cause of failure was due to the impossibility of maintaining sinus rhythm long enough for efficient mapping. CONCLUSION: Patients experiencing short episodes of atrial fibrillation during 24-hour Holter monitoring were the most eligible for mapping and ablation, with a final success rate of 66%, versus the global success rate of 44%. Patients with persistent atrial fibrillation were not good candidates for focal ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The case of a 16-year-old patient with atrioventricular tachycardia caused by a single left anterolateral accessory pathway is reported. When the patient underwent radiofrequency ablation, a lesion on the mitral annulus lateral wall produced changes in the retrograde atrial activation pattern determined by that pathway; changes ranged from a delay in depolarization of the annulus posterior portions to full left atrium counterclockwise activation. Such phenomena were probably caused by a block in the isthmus between the annulus and the lower left pulmonary vein ostium. This case illustrates the importance of the mitral-pulmonary isthmus in the process of left atrium activation, an alert to changes induced by its unintentional block during accessory pathway ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Analyze the dromotropic disturbances (vector-electrocardiographic), and the possible anatomic causes, provoked by selective alcohol injection in the septal branch, for percutaneous treatment, of obstructive hypertrophic cardiomyopathy. METHODS: Ten patients with a mean age of 52.7 years underwent percutaneous septal ablation (PTSA) from october 1998; all in functional class III/IV). Twelve-lead electrocardiogram was performed prior to and during PTSA, and later electrocardiogram and vectorcardiogram according to Frank's method. The patients were followed up for 32 months. RESULTS: On electrocardiogram (ECG) prior to PTSA all patients had sinus rhythm and left atrial enlargement, 8 left ventricular hypertrophy of systolic pattern. On ECG immediately after PTSA, 8 had complete right bundle-branch block; 1 transient total atrioventricular block; 1 alternating transient bundle-branch block either right or hemiblock. On late ECG 8 had complete right bundle-branch block confirmed by vectorcardiogram, type 1 or Grishman. CONCLUSION: Septal fibrosis following alcohol injection caused a predominance of complete right bundle-branch block, different from surgery of myotomy/myectomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine whether recording of the activation potential may be used as an isolated criterion to guide catheter ablation of atriofascicular Mahaim fibers. METHODS: We studied 6 patients (5 females, mean age of 26±7.3 years) with paroxysmal tachycardias with a wide QRS complex, whose electrophysiological study diagnosed atriofascicular Mahaim fibers. Mapping and catheter ablation were performed in sinus rhythm, guided only by the recording of the activation potential of the fiber. RESULTS: Efficacy in ablation was achieved in all patients. The fibers were located in the right lateral region of the tricuspid ring in 3 patients, right posterolateral region in 2, and right anterolateral region in 1. A mean of 5.3±3 radiofrequency applications was performed. The mean fluoroscopy time was 46.6±25 minutes, and the mean duration of the procedure was 178.6±108 minutes. No complication occurred. In a mean 20-month follow-up, all patients were asymptomatic and receiving no antiarrhythmic drugs. CONCLUSION: Catheter ablation of Mahaim fibers may be performed with good safety and efficacy by mapping the activation potential of the tricuspid ring in sinus rhythm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the level of satisfaction with body weight and the self-perception of the weight/height ratio and to verify the influence of the frequency of present and past physical activity on these variables. METHODS: Using questionnaires or interviews, we obtained height data, reported and desired weight, self-perception of the weight/height ratio, and the frequency of current physical activity in 844 adults (489 women). Of these, evaluated the frequency of physical activity during high school of 193 individuals,and we measured their height and weight. RESULTS: Less than 2/3 of the individuals had body mass index between 20 and 24.9 kg/m2. A tendency existed to overestimate height by less than 1 cm and to underestimate weight by less than 1kg. Desired weight was less than that reported (p<0.001), and only 20% were satisfied with their current weight. Only 42% of men and 25% of women exercised regularly. No association was found between the frequency of physical activity and the variables height, weight, and body mass index, and the level of satisfaction with current weight. CONCLUSION: Height and weight reported seem to be valid for epidemological studies, and great dissatisfaction with body weight and a distorted self-perception of height/weight ratio exists, especially in women, regardless of the frequency of physical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the frequency of hypertension in chagasic patients, as well as its clinical behavior and cardiologic findings. METHODS: We carried out a retrospective study with 225 patients with chronic Chagas' disease and hypertension (104 males), mean age of 55.1 ± 11.8. These patients were being followed up in the outpatient care clinics from 1984 to 2000. The study assessed the clinical, electrocardiographic, and radiological viewpoints. RESULTS: Of the 225 hypertensive patients (prevalence = 33.3%), 78 (34.7%) had mild hypertension, 108 (48%) had moderate hypertension, and 39 (17.3%) had severe hypertension. The association of left anterosuperior divisional block and right bundle-branch block occurred in 39 cases (17.3%), and enlargement of the cardiac area on radiological examination occurred in 93 (44.9%) of the 207 cases studied. The undetermined form of Chagas' disease was the most prevalent, 30.2% of the cases, followed by the form associated with conduction disorders in 27.1%, and the isolated form of conduction disorders in 21.3%. CONCLUSION: Chagasic patients had a frequency of hypertension similar to that of the general population, and the clinical profile of the hypertensive chagasic patients seemed not to differ a lot from that of the chagasic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El proyecto tiene como principal objetivo lograr mejorar el enlace entre el tag y el Reader, en un sistema RFID (Radio Frecuency IDentification). El mismo será abordado desde dos ópticas de trabajo; La primera, es lograr el mismo alcance de los sistemas actuales, reduciendo la potencia aportada por el Reader. En esta situación su principal aplicación será en los implantes en seres vivos, disminuyendo la radiación electromagnética en los mismos. La segunda, es lograr aumentar la distancia del alcance del enlace, sin aumentar la potencia del Reader.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El proyecto comprende el diseño, implementación, medición y evaluación de un dispositivo de comunicaciones digitales inalámbrica. Este dispositivo podrá ser utilizado como soporte de distintas aplicaciones, como automatización de viviendas, automatización de edificios inteligentes, control y seguimiento de vehículos, control y monitoreo de animales, instrumental médico y otras. La construcción de un transmisor y un receptor de datos por radiofrecuencia, en un único circuito integrado, plantea distintas etapas y para concretarlas se trazaron los siguientes objetivos: • Diseño, implementación y medición de circuitos de transmisión de datos con integrados existentes. • Estudio de las tecnologías y software disponibles para el diseño de los circuitos que constituyen el proyecto. Diseño, simulación, implementación y medición de circuitos realizados con dispositivos discretos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente proyecto comprende el diseño, simulación, construcción y puesta en funcionamiento de una red inalámbrica. La plataforma de comunicaciones desarrollada en un proyecto anterior se complementa ahora con la implementación de una red inalámbrica, lo cual va a permitir que los módulos de comunicaciones- tres o más -puedan interactuar entre sí. La realización del proyecto surge de la necesidad de contar con una red inalámbrica que permita cubrir grandes distancias y transmitir a una central los datos de los sensores. La principal característica de cada módulo de comunicaciones es que trabajan como repetidores de las demás, permitiendo comunicar a todos y tener bajo consumo. La implementación de una red inalámbrica mencionada en el párrafo anterior está comprometida como parte del Proyecto PAV2003-0076. En dicho proyecto, el equipo va a continuar con la investigación en circuitos y dispositivos de Alta Frecuencia, para ser aplicados en sistemas de telecomunicaciones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La etapa del proyecto para este año consiste en la aplicación concreta de los conocimientos adquiridos. La principal aplicación es la implementación del sistema en la Clínica Reina Fabiola, en el servicio médico que se definirá con las autoridades de la misma. Se continuará trabajando en el diseño de la antena y en la etapa de RF en el Chip Pasivo, que se está desarrollado en conjunto con el equipo de Microelectrónica y en la etapa del transmisor “Reader”. Además se continúa con la investigación en circuitos y dispositivos de Alta Frecuencia, para ser aplicados en sistemas de telecomunicaciones y generar conocimientos para ser transferidos a las distintas cátedras relacionadas con el proyecto. Se establecieron las pautas con la Facultad de Ciencias Agropecuarias para desarrollar una aplicación de trazabilidad de ganado utilizando chips pasivos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Un sistema inalámbrico en UHF puede ser utilizado tanto para la identificación de productos como para la adquisición de datos. Si se encuadra en la identificación se está refiriendo a sistemas “RFID” y si se encuadra en la adquisición de datos se está en presencia de una “Red de Sensores Inalámbrica”. El presente proyecto pretende desarrollar una plataforma de discusión permanente sobre estas tecnología que permita la optimización de los diferentes estamentos de la red. El proyecto tiene como objetivo general mejorar las prestaciones del vinculo entre los distintos elementos en un sistema RFID (Radio Frecuency Identification) o WSN (Wireless Sensor Network). En tal sentido, se propone en una primer línea de investigación, el desarrollo de un modelo que caracterice una red inalámbrica de sensores en UHF, permitiendo luego simularla bajo distintas condiciones. El objetivo es tener una herramienta con la cual se pueda estudiar y simular el comportamiento de una red con varios nodos. Una segunda línea de trabajo aborda el problema del test para sistemas RFID y WSN, con énfasis en nodos activos y pasivos diseñados con circuitos analógicos y digitales configurables y componentes comerciales. Así, se propone el desarrollo de estrategias de test de bajo consumo y alto desempeño focalizadas en las secciones analógicas, de conversión y digitales configurables del nodo. Los trabajos específicos planteados para responder a los objetivos que se pretenden son: La caracterización y modelado del enlace inalámbrico en UHF; La caracterización y modelado del transceptor en sus distintas etapas; La caracterización y modelado de la red con los distintos nodos; El estudio de nuevos diseños de antenas; El estudio de distintas adaptaciones de la etapa de RF con la antena; El estudio de alternativas de distintas modulaciones de las señales a transmitir; Proponer estrategias de simulación y/o emulación de fallas para sistemas analógicos y digitales que permita la evaluación de las estrategias de test y de los mecanismos de recuperación ante fallas; Evaluar el funcionamiento en laboratorio y en campo de los nodos y el lector