978 resultados para Prevention tool
Resumo:
Control banding (CB) can be a useful tool for managing the potential risks of nanomaterials. The here proposed CB, which should be part of an overall risk control strategy, groups materials by hazard and emission potential. The resulting decision matrix proposes control bands adapted to the risk potential levels and helps define an action plan. If this plan is not practical and financially feasible, a full risk assessment is launched. The hazard banding combines key concepts of nanomaterial toxicology: translocation across biological barriers, fibrous nature, solubility, and reactivity. Already existing classifications specific to the nanomaterial can be used "as is." Otherwise, the toxicity of bulk or analogous substances gives an initial hazard band, which is increased if the substance is not easily soluble or if it has a higher reactivity than the substance. The emission potential bands are defined by the nanomaterials' physical form and process characteristics. Quantities, frequencies, and existing control measures are taken into account during the definition of the action plan. Control strategies range from room ventilation to full containment with expert advice. This CB approach, once validated, can be easily embedded in risk management systems. It allows integrating new toxicity data and needs no exposure data. [Authors]
Resumo:
SUMMARY: We present a tool designed for visualization of large-scale genetic and genomic data exemplified by results from genome-wide association studies. This software provides an integrated framework to facilitate the interpretation of SNP association studies in genomic context. Gene annotations can be retrieved from Ensembl, linkage disequilibrium data downloaded from HapMap and custom data imported in BED or WIG format. AssociationViewer integrates functionalities that enable the aggregation or intersection of data tracks. It implements an efficient cache system and allows the display of several, very large-scale genomic datasets. AVAILABILITY: The Java code for AssociationViewer is distributed under the GNU General Public Licence and has been tested on Microsoft Windows XP, MacOSX and GNU/Linux operating systems. It is available from the SourceForge repository. This also includes Java webstart, documentation and example datafiles.
Substance flow analysis as a tool for mitigating the impact of pharmaceuticals on the aquatic system
Resumo:
Hormone replacement therapy (HRT) is an established approach for the treatment and the prevention of osteoporosis. Many studies with bone mineral density as primary outcome have shown significant efficacy. Observational studies have indicated a significant reduction of hip fracture risk in cohorts of women who maintained HRT therapy. The Women's Health Initiative is the first prospective randomised controlled study which showed a positive effect of HRT in terms of reduction of vertebral and hip fractures risk. Unfortunately, this study has been interrupted after 5.2 years because of the unsupportable increase of risk of cardiovascular disease and breast cancer. Compliance with HRT, however, is typically poor because of the potential side effects and possible increased risk of breast or endometrial cancer. Nevertheless, there is now evidence that lower doses of estrogens in elderly women may prevent bone loss while minimizing the side effects seen with higher doses. Combination therapies using low doses estrogen should probably be reserved for patients who continue to fracture on single therapy. Selective estrogen receptor modulators (SERMs) are very interesting drugs. The goal of these agents is to maximize the beneficial effect of estrogen on bone and to minimize or antagonize the deleterious effects on the breast and endometrium. Raloxifene, approved for the prevention and the treatment of osteoporosis, has been shown to reduce the risks of vertebral fracture in large clinical trials. However, they don't reduce non vertebral fractures. Tibolone is a synthetic steroid that increased bone mineral density at lumbar spine and femoral neck. But no trial has been performed with fractures as end point.
Resumo:
Coloring book for the prevention of abduction made by Division of Criminal Investigation
Resumo:
We present a method for using long-term organotypic slice co-cultures of the entorhino-hippocampal formation to analyze the axon-regenerative properties of a determined compound. The culture method is based on the membrane interphase method, which is easy to perform and is generally reproducible. The degree of axonal regeneration after treatment in lesioned cultures can be seen directly using green fluorescent protein (GFP) transgenic mice or by axon tracing and histological methods. Possible changes in cell morphology after pharmacological treatment can be determined easily by focal in vitro electroporation. The well-preserved cytoarchitectonics in the co-culture facilitate the analysis of identified cells or regenerating axons. The protocol takes up to a month.
Resumo:
Report on the Local Public Health Services Grant administered by the Bureau of Local Public Health Services, a division of Health Promotion and Chronic Disease Prevention of the Iowa Department of Public Health for the period July 1, 2006 through June 30, 2008
Resumo:
Several diseases can be prevented either by primary prevention, such as immunisation or behavioural counselling, or secondary prevention such as screening. The new clinical recommendations include screening of abdominal aortic aneurysm among male smokers and ex-smokers aged between 65 and 75 years and the extension of breast cancer screening by mammography for women aged between 40 and 49 years, as well as screening for diabetes among patients with hypertension or dyslipidemia.
Resumo:
OBJECTIVES: Because early etiologic identification is critical to select appropriate specific status epilepticus (SE) management, we aim to validate a clinical tool we developed that uses history and readily available investigations to guide prompt etiologic assessment. METHODS: This prospective multicenter study included all adult patients treated for SE of all but anoxic causes from four academic centers. The proposed tool is designed as a checklist covering frequent precipitating factors for SE. The study team completed the checklist at the time the patient was identified by electroencephalography (EEG) request. Only information available in the emergency department or at the time of in-hospital SE identification was used. Concordance between the etiology indicated by the tool and the determined etiology at hospital discharge was analyzed, together with interrater agreement. RESULTS: Two hundred twelve patients were included. Concordance between the etiology hypothesis generated using the tool and the finally determined etiology was 88.7% (95% confidence interval (CI) 86.4-89.8) (κ = 0.88). Interrater agreement was 83.3% (95% CI 80.4-96) (κ = 0.81). SIGNIFICANCE: This tool is valid and reliable for identification early the etiology of an SE. Physicians managing patients in SE may benefit from using it to identify promptly the underlying etiology, thus facilitating selection of the appropriate treatment.
Resumo:
Cet article présente les résultats de la revue systématique: Jacquerioz FA, Croft AM. Drugs for preventing malaria in travellers. Cochrane Database Syst Rev. 2009 Oct 7;(4):CD006491. PMID: 19821371.
Resumo:
Recent findings suggest an association between exposure to cleaning products and respiratory dysfunctions including asthma. However, little information is available about quantitative airborne exposures of professional cleaners to volatile organic compounds deriving from cleaning products. During the first phases of the study, a systematic review of cleaning products was performed. Safety data sheets were reviewed to assess the most frequently added volatile organic compounds. It was found that professional cleaning products are complex mixtures of different components (compounds in cleaning products: 3.5 ± 2.8), and more than 130 chemical substances listed in the safety data sheets were identified in 105 products. The main groups of chemicals were fragrances, glycol ethers, surfactants, solvents; and to a lesser extent phosphates, salts, detergents, pH-stabilizers, acids, and bases. Up to 75% of products contained irritant (Xi), 64% harmful (Xn) and 28% corrosive (C) labeled substances. Hazards for eyes (59%), skin (50%) and by ingestion (60%) were the most reported. Monoethanolamine, a strong irritant and known to be involved in sensitizing mechanisms as well as allergic reactions, is frequently added to cleaning products. Monoethanolamine determination in air has traditionally been difficult and air sampling and analysis methods available were little adapted for personal occupational air concentration assessments. A convenient method was developed with air sampling on impregnated glass fiber filters followed by one step desorption, gas chromatography and nitrogen phosphorous selective detection. An exposure assessment was conducted in the cleaning sector, to determine airborne concentrations of monoethanolamine, glycol ethers, and benzyl alcohol during different cleaning tasks performed by professional cleaning workers in different companies, and to determine background air concentrations of formaldehyde, a known indoor air contaminant. The occupational exposure study was carried out in 12 cleaning companies, and personal air samples were collected for monoethanolamine (n=68), glycol ethers (n=79), benzyl alcohol (n=15) and formaldehyde (n=45). All but ethylene glycol mono-n-butyl ether air concentrations measured were far below (<1/10) of the Swiss eight hours occupational exposure limits, except for butoxypropanol and benzyl alcohol, where no occupational exposure limits were available. Although only detected once, ethylene glycol mono-n-butyl ether air concentrations (n=4) were high (49.5 mg/m3 to 58.7 mg/m3), hovering at the Swiss occupational exposure limit (49 mg/m3). Background air concentrations showed no presence of monoethanolamine, while the glycol ethers were often present, and formaldehyde was universally detected. Exposures were influenced by the amount of monoethanolamine in the cleaning product, cross ventilation and spraying. The collected data was used to test an already existing exposure modeling tool during the last phases of the study. The exposure estimation of the so called Bayesian tool converged with the measured range of exposure the more air concentrations of measured exposure were added. This was best described by an inverse 2nd order equation. The results suggest that the Bayesian tool is not adapted to predict low exposures. The Bayesian tool should be tested also with other datasets describing higher exposures. Low exposures to different chemical sensitizers and irritants should be further investigated to better understand the development of respiratory disorders in cleaning workers. Prevention measures should especially focus on incorrect use of cleaning products, to avoid high air concentrations at the exposure limits. - De récentes études montrent l'existence d'un lien entre l'exposition aux produits de nettoyages et les maladies respiratoires telles que l'asthme. En revanche, encore peu d'informations sont disponibles concernant la quantité d'exposition des professionnels du secteur du nettoyage aux composants organiques volatiles provenant des produits qu'ils utilisent. Pendant la première phase de cette étude, un recueil systématique des produits professionnels utilisés dans le secteur du nettoyage a été effectué. Les fiches de données de sécurité de ces produits ont ensuite été analysées, afin de répertorier les composés organiques volatiles les plus souvent utilisés. Il a été mis en évidence que les produits de nettoyage professionnels sont des mélanges complexes de composants chimiques (composants chimiques dans les produits de nettoyage : 3.5 ± 2.8). Ainsi, plus de 130 substances listées dans les fiches de données de sécurité ont été retrouvées dans les 105 produits répertoriés. Les principales classes de substances chimiques identifiées étaient les parfums, les éthers de glycol, les agents de surface et les solvants; dans une moindre mesure, les phosphates, les sels, les détergents, les régulateurs de pH, les acides et les bases ont été identifiés. Plus de 75% des produits répertoriés contenaient des substances décrites comme irritantes (Xi), 64% nuisibles (Xn) et 28% corrosives (C). Les risques pour les yeux (59%), la peau (50%) et par ingestion (60%) était les plus mentionnés. La monoéthanolamine, un fort irritant connu pour être impliqué dans les mécanismes de sensibilisation tels que les réactions allergiques, est fréquemment ajouté aux produits de nettoyage. L'analyse de la monoéthanolamine dans l'air a été habituellement difficile et les échantillons d'air ainsi que les méthodes d'analyse déjà disponibles étaient peu adaptées à l'évaluation de la concentration individuelle d'air aux postes de travail. Une nouvelle méthode plus efficace a donc été développée en captant les échantillons d'air sur des filtres de fibre de verre imprégnés, suivi par une étape de désorption, puis une Chromatographie des gaz et enfin une détection sélective des composants d'azote. Une évaluation de l'exposition des professionnels a été réalisée dans le secteur du nettoyage afin de déterminer la concentration atmosphérique en monoéthanolamine, en éthers de glycol et en alcool benzylique au cours des différentes tâches de nettoyage effectuées par les professionnels du nettoyage dans différentes entreprises, ainsi que pour déterminer les concentrations atmosphériques de fond en formaldéhyde, un polluant de l'air intérieur bien connu. L'étude de l'exposition professionnelle a été effectuée dans 12 compagnies de nettoyage et les échantillons d'air individuels ont été collectés pour l'éthanolamine (n=68), les éthers de glycol (n=79), l'alcool benzylique (n=15) et le formaldéhyde (n=45). Toutes les substances mesurées dans l'air, excepté le 2-butoxyéthanol, étaient en-dessous (<1/10) de la valeur moyenne d'exposition aux postes de travail en Suisse (8 heures), excepté pour le butoxypropanol et l'alcool benzylique, pour lesquels aucune valeur limite d'exposition n'était disponible. Bien que détecté qu'une seule fois, les concentrations d'air de 2-butoxyéthanol (n=4) étaient élevées (49,5 mg/m3 à 58,7 mg/m3), se situant au-dessus de la frontière des valeurs limites d'exposition aux postes de travail en Suisse (49 mg/m3). Les concentrations d'air de fond n'ont montré aucune présence de monoéthanolamine, alors que les éthers de glycol étaient souvent présents et les formaldéhydes quasiment toujours détectés. L'exposition des professionnels a été influencée par la quantité de monoéthanolamine présente dans les produits de nettoyage utilisés, par la ventilation extérieure et par l'emploie de sprays. Durant la dernière phase de l'étude, les informations collectées ont été utilisées pour tester un outil de modélisation de l'exposition déjà existant, l'outil de Bayesian. L'estimation de l'exposition de cet outil convergeait avec l'exposition mesurée. Cela a été le mieux décrit par une équation du second degré inversée. Les résultats suggèrent que l'outil de Bayesian n'est pas adapté pour mettre en évidence les taux d'expositions faibles. Cet outil devrait également être testé avec d'autres ensembles de données décrivant des taux d'expositions plus élevés. L'exposition répétée à des substances chimiques ayant des propriétés irritatives et sensibilisantes devrait être investiguée d'avantage, afin de mieux comprendre l'apparition de maladies respiratoires chez les professionnels du nettoyage. Des mesures de prévention devraient tout particulièrement être orientées sur l'utilisation correcte des produits de nettoyage, afin d'éviter les concentrations d'air élevées se situant à la valeur limite d'exposition acceptée.