997 resultados para OPTICAL TOMOGRAPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The following paper introduces the work conducted to create a relative virtual mouse based on the interpretation of head movements and face gesture through a low cost camera and the optical flow of the images. This virtual device is designed specifically as an alternative non-contact pointer for people with mobility impairments in the upper extremities and reduced head control. The proposed virtual device was compared with a conventional mouse, a touchpad and a digital joystick. Validation results show performances close to a digital joystick but far away from a conventional mouse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aim of this study was to evaluate the stability over time of the individually defined interval of intravitreal ranibizumab injection (IVR) for the treatment of recurrent macular edema (ME) in central retinal vein occlusion (CRVO). Patients and Methods: A case series of treatment naïve patients followed in the Jules Gonin Eye Hospital for macular edema due to central retinal vein occlusion is presented. Patients were treated monthly with IVR until complete absence of fluid on qualitative SD-OCT with a minimum of 5 monthly IVR. Thereafter, they were followed according to a modified treat and extend regimen (mTER). Results: Twelve eyes (12 patients) with ME due to CRVO were included. The mean follow-up period was 31.3 months. Analysis showed that best corrected visual acuity (BCVA), central macular thickness and qualitative spectral domain optical coherence tomography (SD-OCT) showed comparable results under monthly interval, after titration of an individualized interval and when performed in a series. 78 % of treating intervals were within ± 2 weeks of the first individually adjusted interval. The mean first defined interval was 4.3 weeks and the mean interval over time was 5.5 weeks (p = 0.003). There was a trend towards longer interval over time. Conclusion: The adjusted interval of retreatment of patients with ME due to CRVO showed a high stability with a trend toward longer duration over time. An mTER regimen seems to be valuable to follow patients with ME with good stabilization of VA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The purpose of this contribution is to report our functional results on the efficacy of intravitreal ranibizumab for submacular choroidal neovessels (CNV) in high myopia, and to compare the roles of optical coherence tomography (OCT), fluorescein angiography and visual acuity changes in the treatment decision prior to each injection. Patients and Methods: This is a retrospective study performed in Jules Gonin Eye Hospital. It included all patients with myopic CNV treated with intravitreal ranibizumab injections with a minimum follow-up of 24 months. After an induction dosing from 1 to 3 injections, the follow-up was based on a pro re nata regimen. Ophthalmic evaluation, best corrected visual acuity, and OCT were done at each visit, and fluorescein angiography at baseline and if neovascular activity was suspected. Retreatment criteria included metamorphopsia, visual loss of ≥ 5 ETDRS letters, any fluid on OCT and/or leakage on fluorescein angiography. Results: 24 eyes were included in the study. Mean follow-up was 49 months. Mean visual acuity improved significantly from 62.8 ± 13.8 letters at baseline to 72.8 ± 12.9 letters at last follow-up visit (p = 0.001). The mean number of injections was 2.2 in the first year and below 1 for the following years. The sensitivities of fluorescein angiography, SD OCT, and visual acuity loss ≥ 5 letters were 62.6 %, 51.4 %, and 40 %, respectively. The fluorescein angiography showed a significantly higher sensitivity in treatment decision than OCT (p = 0.007). Conclusion: Our study has shown that ranibizumab injections provide a significant long-term visual benefit in myopic CNV with a small number of injections. Fluorescein angiography has a preponderant role in the treatment decision of active myopic CNV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2×2×3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light confinement strategies in thin-film silicon solar cells play a crucial role in the performance of the devices. In this work, the possible use of Ag-coated stamped polymers as reflectors to be used in n-i-p solar cells is studied. Different random roughnesses (nanometer and micrometer size) have been transferred on poly(methylmethacrylate) (PMMA) by hot embossing. Morphological and optical analyses of masters, stamped polymers and reflectors have been carried out evidencing a positive surface transference on the polymer and the viability of a further application in solar cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optical and electrical recovery processes of the metastable state of the EL2 defect artificially created in n‐type GaAs by boron or oxygen implantation are analyzed at 80 K using optical isothermal transient spectroscopy. In both cases, we have found an inhibition of the electrical recovery and the existence of an optical recovery in the range 1.1-1.4 eV, competing with the photoquenching effect. The similar results obtained with both elements and the different behavior observed in comparison with the native EL2 defect has been related to the network damage produced by the implantation process. From the different behavior with the technological process, it can be deduced that the electrical and optical anomalies have a different origin. The electrical inhibition is due to the existence of an interaction between the EL2 defect and other implantation‐created defects. However, the optical recovery seems to be related to a change in the microscopic metastable state configuration involving the presence of vacancies

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ectopic ACTH Cushing's syndrome (EAS) is often caused by neuroendocrine tumors (NETs) of lungs, pancreas, thymus, and other less frequent locations. Localizing the source of ACTH can be challenging. A 64-year-old man presented with rapidly progressing fatigue, muscular weakness, and dyspnea. He was in poor condition and showed facial redness, proximal amyotrophy, and bruises. Laboratory disclosed hypokalemia, metabolic alkalosis, and markedly elevated ACTH and cortisol levels. Pituitary was normal on magnetic resonance imaging (MRI), and bilateral inferior petrosal sinus blood sampling with corticotropin-releasing hormone stimulation showed no significant central-to-periphery gradient of ACTH. Head and neck, thoracic and abdominal computerized tomography (CT), MRI, somatostatin receptor scintigraphy (SSRS), and (18)F-deoxyglucose-positron emission tomography (FDG-PET) failed to identify the primary tumor. (18)F-dihydroxyphenylalanine (F-DOPA)-PET/CT unveiled a 20-mm nodule in the jejunum and a metastatic lymph node. Segmental jejunum resection showed two adjacent NETs, measuring 2.0 and 0.5 cm with a peritoneal metastasis. The largest tumor expressed ACTH in 30% of cells. Following surgery, after a transient adrenal insufficiency, ACTH and cortisol levels returned to normal values and remain normal over a follow-up of 26 months. Small mid-gut NETs are difficult to localize on CT or MRI, and require metabolic imaging. Owing to low mitotic activity, NETs are generally poor candidates for FDG-PET, whereas SSRS shows poor sensitivity in EAS due to intrinsically low tumor concentration of type-2 somatostatin receptors (SST2) or to receptor down regulation by excess cortisol. However, F-DOPA-PET, which is related to amine precursor uptake by NETs, has been reported to have high positive predictive value for occult EAS despite low sensitivity, and constitutes a useful alternative to more conventional methods of tumor localization. LEARNING POINTS: Uncontrolled high cortisol levels in EAS can be lethal if untreated.Surgical excision is the keystone of NETs treatment, thus tumor localization is crucial.Most cases of EAS are caused by NETs, which are located mainly in the lungs. However, small gut NETs are elusive to conventional imaging and require metabolic imaging for detection.FDG-PET, based on tumor high metabolic rate, may not detect NETs that have low mitotic activity. SSRS may also fail, due to absent or low concentration of SST2, which may be down regulated by excess cortisol.F-DOPA-PET, based on amine-precursor uptake, can be a useful method to localize the occult source of ACTH in EAS when other methods have failed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 48-year-old man was examined 24 months after medial and surgical treatment of an isolated well-circumscribed right occipital lobe abscess. An asymptomatic residual left homonymous inferior scotoma was present. Fundus examination revealed temporal pallor of both optic discs, and optical coherence tomography (OCT) revealed mild temporal loss of retinal nerve fiber layer in both eyes. No relative afferent pupillary defect was present. Assessment of the retinal ganglion cell layer demonstrated homonymous thinning in a pattern corresponding to the homonymous visual field loss. There were no abnormalities of the lateral geniculate nuclei or optic tracts on review of the initial brain computed tomography and follow-up magnetic resonance imaging. We believe our patient showed evidence of transsynaptic retrograde degeneration after an isolated right occipital lobe lesion, and the homonymous neuronal loss was detected on OCT by assessing the retinal ganglion cell layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the visual acuity results of eyes with neovascular age-related macular degeneration and refractory fluid despite monthly treatment with ranibizumab, and to investigate differences between refractory subretinal fluid and intraretinal cystic changes. METHODS: Retrospective chart review of consecutive treatment-refractory neovascular age-related macular degeneration, defined as persistent intraretinal or subretinal fluid despite monthly ranibizumab injections during 12 months or more. Data were evaluated for baseline characteristics, type and location of the refractory fluid, mean visual acuity change, number of injections, and the time point of first complete disappearance of all fluid on spectral domain optical coherence tomography. RESULTS: Seventy-six eyes (74 patients, mean age, 76.8 years) were identified. The mean follow-up was 33.6 months (range, 12-73 months). The mean number of injections was 11.4 in the first year and 27.7 over follow-up. The refractory fluid was located subfoveally in 61.8%. In 27 eyes (35.5%), the fluid resolved after a mean of 21.8 months (range, 13-49 months). Mean visual acuity increased by 9.0, 7.9, and 7.9 letters by Month 12, Month 24, and Month 36, respectively. Subgroup analysis revealed a higher risk for fibrosis (odds ratio, 3.30) or atrophy (odds ratio, 3.34) in patients with refractory cysts as compared with refractory subretinal fluid. Furthermore, refractory cysts showed a higher risk for a 10-letter visual acuity loss (P = 0.018). CONCLUSION: Fluid refractory to monthly treatment with ranibizumab for neovascular age-related macular degeneration still allowed for well-maintained visual improvement, even in subfoveal location. Late fluid resolution may occur. However, refractory cysts were associated with poorer anatomical and functional outcome than subretinal fluid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical impedance tomography (EIT) is a non-invasive imaging technique that can measure cardiac-related intra-thoracic impedance changes. EIT-based cardiac output estimation relies on the assumption that the amplitude of the impedance change in the ventricular region is representative of stroke volume (SV). However, other factors such as heart motion can significantly affect this ventricular impedance change. In the present case study, a magnetic resonance imaging-based dynamic bio-impedance model fitting the morphology of a single male subject was built. Simulations were performed to evaluate the contribution of heart motion and its influence on EIT-based SV estimation. Myocardial deformation was found to be the main contributor to the ventricular impedance change (56%). However, motion-induced impedance changes showed a strong correlation (r = 0.978) with left ventricular volume. We explained this by the quasi-incompressibility of blood and myocardium. As a result, EIT achieved excellent accuracy in estimating a wide range of simulated SV values (error distribution of 0.57 ± 2.19 ml (1.02 ± 2.62%) and correlation of r = 0.996 after a two-point calibration was applied to convert impedance values to millilitres). As the model was based on one single subject, the strong correlation found between motion-induced changes and ventricular volume remains to be verified in larger datasets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Malignant hypertension is defined by marked systemic arterial hypertension with retinal haemorrhages, exudation or papilloedema. Due to the rarity of this disease and due to its non-specific symptoms and lesions, the diagnosis can be challenging. Patients and Methods We investigated the types of symptoms and ocular lesions observed with ocular fundus examination, ocular fundus photography, fluorescein angiography and optical coherence tomography in a small case series of 7 patients with malignant hypertension. Results: Median systolic blood pressure (BP) was 205 mmHg ± 21. Median diastolic BP was 150 mmHg ± 16. Decrease in visual acuity (6/7 patients) and scotoma (5/7) were the main symptoms and Elschnig spot, flamed shaped haemorrhage, serous retinal detachment, cotton wool spots and optic nerve oedema were the five most frequently observed lesions. A regression of lesions was observed after therapy of systemic hypertension. Conclusion: The association of multiple lesions strongly suggests malignant hypertension. However even in cases with only one lesion malignant hypertension should be kept in mind.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical resistivity tomography (ERT) is a well-established method for geophysical characterization and has shown potential for monitoring geologic CO2 sequestration, due to its sensitivity to electrical resistivity contrasts generated by liquid/gas saturation variability. In contrast to deterministic inversion approaches, probabilistic inversion provides the full posterior probability density function of the saturation field and accounts for the uncertainties inherent in the petrophysical parameters relating the resistivity to saturation. In this study, the data are from benchtop ERT experiments conducted during gas injection into a quasi-2D brine-saturated sand chamber with a packing that mimics a simple anticlinal geological reservoir. The saturation fields are estimated by Markov chain Monte Carlo inversion of the measured data and compared to independent saturation measurements from light transmission through the chamber. Different model parameterizations are evaluated in terms of the recovered saturation and petrophysical parameter values. The saturation field is parameterized (1) in Cartesian coordinates, (2) by means of its discrete cosine transform coefficients, and (3) by fixed saturation values in structural elements whose shape and location is assumed known or represented by an arbitrary Gaussian Bell structure. Results show that the estimated saturation fields are in overall agreement with saturations measured by light transmission, but differ strongly in terms of parameter estimates, parameter uncertainties and computational intensity. Discretization in the frequency domain (as in the discrete cosine transform parameterization) provides more accurate models at a lower computational cost compared to spatially discretized (Cartesian) models. A priori knowledge about the expected geologic structures allows for non-discretized model descriptions with markedly reduced degrees of freedom. Constraining the solutions to the known injected gas volume improved estimates of saturation and parameter values of the petrophysical relationship. (C) 2014 Elsevier B.V. All rights reserved.