923 resultados para NONPOLARIZING BEAM SPLITTER


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proton therapy is a high precision technique in cancer radiation therapy which allows irradiating the tumor with minimal damage to the surrounding healthy tissues. Pencil beam scanning is the most advanced dose distribution technique and it is based on a variable energy beam of a few millimeters FWHM which is moved to cover the target volume. Due to spurious effects of the accelerator, of dose distribution system and to the unavoidable scattering inside the patient's body, the pencil beam is surrounded by a halo that produces a peripheral dose. To assess this issue, nuclear emulsion films interleaved with tissue equivalent material were used for the first time to characterize the beam in the halo region and to experimentally evaluate the corresponding dose. The high-precision tracking performance of the emulsion films allowed studying the angular distribution of the protons in the halo. Measurements with this technique were performed on the clinical beam of the Gantry1 at the Paul Scherrer Institute. Proton tracks were identified in the emulsion films and the track density was studied at several depths. The corresponding dose was assessed by Monte Carlo simulations and the dose profile was obtained as a function of the distance from the center of the beam spot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Tokai-to-Kamioka (T2K) neutrino experiment measures neutrino oscillations by using an almost pure muon neutrino beam produced at the J-PARC accelerator facility. The T2K muon monitor was installed to measure the direction and stability of the muon beam which is produced together with the muon neutrino beam. The systematic error in the muon beam direction measurement was estimated, using data and MC simulation, to be 0.28 mrad. During beam operation, the proton beam has been controlled using measurements from the muon monitor and the direction of the neutrino beam has been tuned to within 0.3 mrad with respect to the designed beam-axis. In order to understand the muon beam properties, measurement of the absolute muon yield at the muon monitor was conducted with an emulsion detector. The number of muon tracks was measured to be (4.06 ± 0.05) × 10⁴ cm⁻² normalized with 4 × 10¹¹protons on target with 250 kA horn operation. The result is in agreement with the prediction which is corrected based on hadron production data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of the AEgIS experiment is to measure the gravitational acceleration of antihydrogen – the simplest atom consisting entirely of antimatter – with the ultimate precision of 1%. We plan to verify the Weak Equivalence Principle (WEP), one of the fundamental laws of nature, with an antimatter beam. The experiment consists of a positron accumulator, an antiproton trap and a Stark accelerator in a solenoidal magnetic field to form and accelerate a pulsed beam of antihydrogen atoms towards a free-fall detector. The antihydrogen beam passes through a moir ́e deflectometer to measure the vertical displacement due to the gravitational force. A position and time sensitive hybrid detector registers the annihilation points of the antihydrogen atoms and their time-of-flight. The detection principle has been successfully tested with antiprotons and a miniature moir ́e deflectometer coupled to a nuclear emulsion detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radioactivity induced by a 15-MeV proton beam extracted into air was studied at the beam transport line of the 18-MeV cyclotron at the Bern University Hospital (Inselspital). The produced radioactivity was calculated and measured by means of proportional counters located at the main exhaust of the laboratory. These devices were designed for precise assessment of air contamination for radiation protection purposes. The main produced isotopes were 11C, 13N and 14O. Both measurements and calculations correspond to two different irradiation conditions. In the former, protons were allowed to travel for their full range in air. In the latter, they were stopped at the distance of 1.5 m by a beam dump. Radioactivity was measured continuously in the exhausted air starting from 2 min after the end of irradiation. For this reason, the short-lived 14O isotope gave a negligible contribution to the measured activity. Good agreement was found between the measurements and the calculations within the estimated uncertainties. Currents in the range of 120–370 nA were extracted in air for 10–30 s producing activities of 9–22 MBq of 11C and 13N. The total activities for 11C and 13N per beam current and irradiation time for the former and the latter irradiation conditions were measured to be (3.60 ± 0.48) × 10−3 MBq (nA s)−1 and (2.89 ± 0.37) × 10−3 MBq (nA s)−1, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Segmented ionization chambers represent a good solution to monitor the position, the intensity and the shape of ion beams in hadrontherapy. Pixel and strip chambers have been developed for both passive scattering and active scanning dose delivery systems. In particular, strip chambers are optimal for pencil beam scanning, allowing for spatial and time resolutions below 0.1 mm and 1 ms, respectively. The MATRIX pixel and the Strip Accurate Monitor for Beam Applications (SAMBA) detectors are described in this paper together with the results of several beam tests and industrial developments based on these prototypes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se describe un procedimiento para la consolidación de viguetas de forjado de madera con deterioro en las cabezas mediante perfiles de acero conectados a la madera desde la cara superior del forjado. La pieza de refuerzo es un perfil en U de acero S275 conformado en frío con pletinas soldadas insertadas en la madera y conectada mediante tirafondos. Se ensayaron 30 piezas a flexión obteniendo la rigidez y la capacidad de carga. Las probetas se dividieron en tres grupos. El primero compuesto por 10 piezas de madera laminada encolada de abeto con una sección de 180 x 200 mm y una longitud de 4.000 mm; el segundo consistía en 10 piezas de madera aserrada de pino silvestre con la misma sección y longitud y, el tercero, estaba formado por otras 10 piezas de madera del género Pinus con una sección de 130 x 150 mm y 3.000 mm de longitud, procedentes de un edificio de Madrid con 120 años de antigüedad. Cada grupo de 10 piezas se dividió a su vez en dos grupos de 5 piezas. El primer subgrupo estaba formado por las piezas completas de madera y constituía el grupo de referencia. Las piezas del segundo subgrupo tenían una longitud inferior que se salvaba con una extensión del refuerzo metálico. Los resultados indican que el sistema de refuerzo metálico permite resolver los problemas de falta de apoyo de la vigueta por deterioro de la madera que afecte en una longitud limitada (aproximadamente entre el 10 y el 20% de la longitud).