942 resultados para Mechanical compression testing
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia de Materiais
Resumo:
The method used by YAGYU et al. for the subtype-specific polymerase chain reaction (PCR) amplification of the gp41 transmembrane region of the human immunodeficiency virus type-1 (HIV-1) env gene, was tested. HIV-1 proviral DNA from 100 infected individuals in Itajaí, South Brazil was used to analyze this method. Seventy individuals were determined according to this method as having PCR products at the expected size for subtypes B, C, D and F. Of these individuals, 26 (37.1%) were observed as having the expected amplification for subtype C, and 42 (60%) were observed as having the expected products for subtypes B and D. Of the subtype B and D amplicons, 16 (22.9%) were classified as subtype D, and 26 (37.1%) were classified as subtype B. Two individuals (2.9%) had amplicons that were observed after subtype F-specific amplification was performed. Sequencing and comparing the patient sequences to reference sequences confirmed the classification of sequences of subtypes C and B. However, sequences that were falsely determined as being D and F in the PCR assay were determined as being subtypes C and B, respectively, by sequence analysis. For those individuals from whom no amplified products were obtained, a low viral load that was indicated in their patient history may explain the difficulty in subtyping by PCR methods. This issue was demonstrated by the results of ANOVA when testing the effect of viral load on the success of PCR amplification. The alignment of the obtained sequences with HIV-1 reference sequences demonstrated that there is high intra-subtype diversity. This indicates that the subtype-specific primer binding sites were not conserved or representative of the subtypes that are observed in the Brazilian populations, and that they did not allow the correct classification of HIV-1 subtypes. Therefore, the proposed method by YAGYU et al. is not applicable for the classification of Brazilian HIV-1 subtypes.
Resumo:
A tecnologia de ligação por adesivos estruturais tem vindo a ser utilizada ao longo de várias décadas, permitindo solucionar diversos problemas associados a técnicas chamadas "tradicionais" de ligação, como a soldadura, a rebitagem ou a ligação aparafusada. Esta é uma alternativa viável para substituir as ligações mecânicas, devido a diversos fatores como o menor peso estrutural, menor custo de fabricação e capacidade de união de diferentes materiais. O crescente recurso a materiais compósitos em diversas indústrias, nomeadamente a aeronáutica e naval, levaram ao consequente aumento da aplicação de ligações adesivas, por serem indicadas como forma de união destes materiais, onde é de enaltecer a sua elevada resistência à fadiga. Uma junta adesiva está maioritariamente sujeita a esforços de corte e arrancamento e portanto o conhecimento dos módulos de elasticidade à tração (E) ou corte (G) do adesivo, e ainda as resistências máximas à tração e ao corte, não é suficiente quando se pretende prever o comportamento da mesma. Na verdade, torna-se necessário abranger na análise a plastificação progressiva verificada nas juntas adesivas antes da rotura, sendo necessário o conhecimento de parâmetros tais como a taxa crítica de libertação de energia de deformação à tração (GIc) e corte (GIIc). Este trabalho pretende estudar um adesivo estrutural recentemente lançado no mercado, carecendo portanto da sua caracterização, para facilitar a previsão da resistência de estruturas adesivas ligadas com o mesmo. São 4 os ensaios a realizar: ensaios à tração de provetes em bruto, ensaios ao corte com a geometria Thick Adherend Shear Test (TAST), ensaios Double-Cantilever Beam (DCB) e ensaios End-Notched Flexure (ENF). Com a realização dos ensaios referidos, serão determinadas as propriedades mecânicas e de fratura à tração e ao corte, e serão fornecidos os parâmetros para a previsão da resistência de juntas adesivas com este adesivo por uma variedade de métodos, desde métodos analíticos mais expeditos até aos métodos numéricos mais avançados existentes atualmente. Os resultados foram de encontro aos disponibilizados pelo fabricante, sempre que estes se encontravam disponíveis, obtendo-se discrepâncias bastante reduzidas nos diversos parâmetros determinados.
Resumo:
A contínua subida dos preços dos combustíveis fósseis tradicionais aliada à crescente pressão por parte de várias instituições mundiais para uma política “verde” no que diz respeito aos combustíveis, levam a um aumento da procura dos biocombustíveis e é neste contexto que surge o biodiesel como um dos principais intervenientes. O biodiesel pode ser definido como um derivado éster monoalquílico de ácidos gordos de cadeia longa proveniente de fontes renováveis como óleos vegetais ou gorduras animais e que apresenta características semelhantes ao diesel de petróleo, podendo ser utilizado sem qualquer problema em motores de ignição por compressão. Este trabalho apresenta como principal objetivo o estudo da aplicação da tecnologia de ultrassons na produção de biodiesel. Foi utilizado neste trabalho como matéria-prima um óleo doméstico usado. Este óleo foi previamente filtrado sendo depois analisado o seu índice de acidez para avaliar o seu teor em ácidos gordos livres. O valor obtido para o índice de acidez do óleo foi de 1,91 mg KOH/g, um valor relativamente baixo permitindo a sua utilização sem ser necessário um tratamento inicial via esterificação para diminuir a acidez do mesmo. Foram realizados três ensaios de reação independentes, o primeiro recorrendo ao método tradicional de produção de biodiesel através de transesterificação e recorrendo a agitação mecânica e aquecimento, o segundo utilizando uma sonda de ultrassons com a potência de 500 W e um terceiro ensaio de reação utilizando uma sonda de ultrassons de 2000 W. Em todas as reações foi utilizada uma proporção de 1:5 de óleo usado e metanol e 0,5 % (em relação á massa de óleo utilizada) de catalisador metilato de sódio. Todas as alíquotas recolhidas durante os ensaios foram analisadas através de cromatografia gasosa de modo a determinar o conteúdo em ésteres presente em cada uma delas. A reação convencional teve uma duração total de 150 minutos e decorreu a uma temperatura de 65ºC e a agitação constante de 500 rpm. Ao longo da reação foram retiradas alíquotas de cerca de 25 ml, que foram tratadas de imediato e posteriormente analisadas de modo a estudar-se o comportamento da reação ao longo do tempo. A percentagem de ésteres metílicos no biodiesel obtida ao fim de 90 minutos foi de 81,3%. Em seguida realizou-se uma reação utilizando uma sonda de ultrassons de 500 W de potência mergulhada num recipiente reacional devidamente isolado com uma rolha de cortiça de modo a minimizar as perdas de metanol por evaporação. O tempo total de reação foi de 90 minutos e foram-se retirando alíquotas de cerca de 25 ml para acompanhar o desenrolar da reação, tendo-se obtido uma percentagem de ésteres metílicos de 85,9% ao fim dos 90 minutos. Foi realizada por fim um terceiro ensaio de reação utilizando uma sonda de 2000 W com uma duração total de 90 minutos, tendo-se obtido resultados pouco satisfatórios (77,7%), provavelmente devido a algum problema operacional relacionado com a sonda de ultrassons utilizada ou devido a uma geometria do reator pouco eficiente. Os produtos resultantes da reação convencional e da reação utilizando a sonda de ultrassons de 500 W, assim como o óleo utilizado como matéria-prima foram caracterizados em termos de índice de acidez, densidade a 15ºC e viscosidade a 40ºC.
Resumo:
O veículo guiado automaticamente (AGV) adquirido pelo Departamento de Engenharia Mecânica (DEM) tem vindo a ficar obsoleto devido ao hardware, que nos dias de hoje começa a dar sinais de falhas bem como falta de peças de substituição, e ao software, sendo o PLC (Programmable Logic Controller) usado muito limitado quanto às suas funções de controlo, ficando as principais tarefas de controlo do AGV a cargo de placas eletrónicas de controlo. Para promover o controlo autónomo do AGV, foi decidido retirar toda a parte de hardware que detinha o controlo do mesmo e passou a ser um novo PLC, com maior capacidade de processamento, a executar todo o tipo de controlo necessário ao funcionamento do mesmo. O hardware considerado apenas incluí, de forma resumida, os motores responsáveis pelo movimento e direção, placa de controlo de potência dos motores, placa de interface entre as saídas digitais do PLC e as entradas da placa de controlo de potência dos motores e os demais sensores necessários à deteção de obstáculos, fins de curso da direção, sensores dos postos de trabalho e avisadores de emergência. Todo o controlo de movimento e direção bem como a seleção das ações a executar passou a ficar a cargo do software programado no PLC assim como a interação entre o sistema de supervisão instalado num posto de controlo e o PLC através de comunicação via rádio. O uso do PLC permitiu a flexibilidade de mudar facilmente a forma como as saídas digitais são usadas, ao contrário de um circuito eletrónico que necessita de uma completa remodelação, tempo de testes e implementação para efetuar a mesma função. O uso de um microcontrolador seria igualmente viável para a aplicação em causa, no entanto o uso do PLC tem a vantagem de ser robusto, mais rápido na velocidade de processamento, existência de software de interface de programação bastante intuitivo e de livre acesso, facilidade de alterar a programação localmente ou remotamente, via rádio, acesso a vários protocolos de comunicação robustos como Modbus, Canbus, Profinet, Modnet, etc., e acesso integrado de uma consola gráfica totalmente programável. iv É ainda possível a sua expansão com adição de módulos de entradas e saídas digitais e/ou analógicas permitindo expandir largamente o uso do AGV para outros fins. A solução está a ser amplamente testada e validada no Laboratório de Automação (LabA) do Departamento de Engenharia Mecânica do ISEP (Instituto Superior de Engenharia do Porto), permitindo a otimização dos sistemas de controlo de direção bem como a interatividade entre o PLC e o programa de interface/supervisão do posto de trabalho.
Resumo:
The objective of this study is to report on the colonization of palm trees by Rhodnius neglectus, its invasion in an urban area, in Araçatuba - São Paulo, and the control and surveillance measures that have been put in place. Domiciliary triatomine searches occurred in apartments upon the inhabitants' notification. The collected insects were identified and examined for natural infection and food sources with a precipitin test. To search the palm trees, tarps were used to cover the floor, and a “Munck” truck equipped with a tree-pruning device was utilized. Chemical control was performed with the utilization of a manual compression. In 2009, 81 specimens of Rhodnius neglectus were collected from the domiciles by the population. The precipitin test revealed a presence of human blood in 2.7% of the samples. Entomological studies were carried out in these domiciles and in those located within a radius of 200 meters. The search performed in the palm trees resulted in the capture of 882 specimens of triatomines, negative for tripanosomatids. Mechanical and chemical controls were carried out. New searches conducted in the palm trees in the same year resulted in the capture of six specimens. The mechanical and chemical controls of the palm trees, together with the population's work, proved to be effective, therefore preventing these insects' colonization of the city's domiciles.
Resumo:
The aim of this cross-sectional study was to determine the hepatitis B vaccination coverage among medical students at a public university in Rio de Janeiro, Brazil, and their compliance with the postvaccination serologic testing recommendations. Of the total of 858 students, 675 (78.7%) participated in the study. Among the participants, 48.9% (95% CI: 45.1% to 52.7%) were vaccinated against hepatitis B (received ≥ 3 doses of the vaccine), 31.6% were not (received 0, 1 or 2 doses), and 19.6% did not know their vaccination status. Hepatitis B vaccination coverage increased from 26.0% among first-year students to 70.6% among sixth-year students while the prevalence of unknown vaccination status decreased from 39.7% among first-year students to 2.4% among sixth-year students. The frequency of unvaccinated students ranged from 23.7% among fifth-year students to 34.4% among first-year students. Only 34.8% of the vaccinated students performed the anti-HBs testing after vaccination. Among these medical students, we found a low adherence to the hepatitis B vaccination and to the postvaccination serologic testing. A comprehensive hepatitis B immunization program should be offered to students at this medical school.
Resumo:
A pultrusão é uma técnica já sobejamente conhecida de produção de perfis de secção constante, tais como barras, cantoneiras, perfis estruturais ou tubos, em materiais compósitos de matriz polimérica. A necessidade de, em determinadas aplicações, utilizar perfis que proporcionem melhor isolamento térmico, melhor isolamento acústico ou possuam um momento de inércia ligeiramente superior, sem que o peso próprio seja significativamente afectado, levou à produção de perfis pultrudidos híbridos, com núcleos baseados em pré-formas ou na alimentação contínua de resíduos. Realizados os protótipos seguindo as metodologias acima descritas, urge verificar se as propriedades dos perfis híbridos correspondem às expectativas inicialmente neles depositadas, através de testes destrutivos e não-destrutivos. Assim, foram realizados testes à tracção, à compressão e à flexão, no intuito de verificar os ganhos conseguidos e poder analisar o valor-acrescentado trazido por estes novos perfis em termos estruturais. Estes valores, depois de devidamente validados, permitirão a sua inserção em bases de dados agregadas a programas de cálculo estrutural, que efectuam de forma automática o dimensionamento de estruturas baseadas em perfis desta natureza. Complementarmente, foram realizados testes de isolamento térmico e acústico, com vista a quantificar a melhoria conseguida nestas propriedades, extremamente importantes em determinados tipos de aplicações ligadas à construção civil e obras públicas.
Resumo:
Background: Allergic rhinitis and asthma (ARA) are chronic inflammatory diseases of the airways that often coexist in children. The only tool to assess the ARA control, the Control of Allergic Rhinitis and Asthma Test (CARAT) is to be used by adults. We aimed to develop the Pediatric version of Control of Allergic Rhinitis and Asthma Test (CARATkids) and to test its comprehensibility in children with 4 to 12 years of age. Methods: The questionnaire development included a literature review of pediatric questionnaires on asthma and/or rhinitis control and two consensus meetings of a multidisciplinary group. Cognitive testing was carried out in a cross-sectional qualitative study using cognitive interviews. Results: Four questionnaires to assess asthma and none to assess rhinitis control in children were identified. The multidisciplinary group produced a questionnaire version for children with 17 questions with illustrations and dichotomous (yes/no) response format. The version for caregivers had 4-points and dichotomous scales. Twenty-nine children, 4 to 12 years old, and their caregivers were interviewed. Only children over 6 years old could adequately answer the questionnaire. A few words/expressions were not fully understood by children of 6 to 8 years old. The drawings illustrating the questions were considered helpful by children and caregivers. Caregivers considered the questionnaire complete and clear and preferred dichotomous over the 4-points scales. The proportion of agreement between children and their caregivers was 61%. The words/expressions that were difficult to understand were amended. Conclusion: CARATkids, the first questionnaire to assess a child’s asthma and rhinitis control was developed and its content validity was assured. Cognitive testing showed that CARATKids is well-understood by children 6 to 12 years old. The questionnaire’s measurement properties can now be assessed in a validation study.
Resumo:
Dissertation presented to obtain the Ph.D degree in Biochemisry, Biotechnology
Resumo:
Ao longo destes últimos anos as ligações adesivas têm vindo a verificar um aumento progressivo em aplicações estruturais em detrimento das ligações mecânicas convencionais. Esta alteração de paradigma deve-se às vantagens que as juntas adesivas possuem relativamente aos outros métodos de ligação. A mecânica da fratura e os Modelos de Dano Coesivo (MDC) são critérios comuns para prever a resistência em juntas adesivas e usam como parâmetros fundamentais as taxas de libertação de energia. Pelo facto do ensaio 4-Point End Notched Flexure (4-ENF), aplicado em juntas adesivas, ainda estar pouco estudado é de grande relevância um estudo acerca da sua viabilidade para a determinação da taxa crítica de libertação de energia de deformação ao corte (GIIc). Esta dissertação tem como objetivo principal efetuar uma comparação entre os métodos End- Notched Flexure (ENF) e 4-ENF na determinação de GIIc em juntas adesivas. Para tal foram utilizados 3 adesivos: Araldite® AV138, Araldite® 2015 e SikaForce® 7752. O trabalho experimental passou pela conceção e fabrico de uma ferramenta para realização do ensaio 4-ENF, seguindo-se o fabrico e a preparação dos provetes para os ensaios. Pelo facto do ensaio 4-ENF ainda se encontrar pouco divulgado em juntas adesivas, e não se encontrar normalizado, uma parte importante do trabalho passou pela pesquisa e análise em trabalhos de investigação e artigos científicos. A análise dos resultados foi realizada por comparação direta dos valores de GIIc com os resultados obtidos no ensaio ENF, sendo realizada por série de adesivo, através da comparação das curvas P-δ e curvas-R. Como resultado verificou-se que o ensaio 4-ENF em ligações adesivas não é o mais versátil para a determinação do valor de GIIc, e que apenas um método de obtenção de GIIc é viável. Este método é baseado na medição do comprimento de fenda (a). Ficou evidenciado que o ensaio ENF, devido a ser um ensaio normalizado, por apresentar um setup mais simples e por apresentar uma maior disponibilidade de métodos para a determinação do valor de GIIc, é o mais recomendado. Conclui-se assim que o ensaio 4-ENF, embora sendo uma alternativa ao ensaio ENF, tem aplicação mais limitada.
Resumo:
This case report discusses an unusual presentation of ST-segment elevation myocardial infarction (STEMI) with normal coronary arteries and severe mechanical complications successfully treated with surgery. An 82-year-old man presented STEMI with angiographically normal coronary arteries and no major echocardiographic alterations at discharge. At the first month follow-up, he complained of fatigue and dyspnea, and contrast echocardiography complemented by cardiac magnetic resonance imaging revealed a large left ventricular apical aneurysm with a thrombus communicating by two jets of a turbulent flow to an aneurysmatic formation of the right ventricular apex. The patient underwent a Dor procedure, which was successful. Ventricular septal defects and ventricular aneurysms are rare but devastating complications of STEMI, with almost all patients presenting multivessel coronary artery disease. Interestingly in this case, the angiographic pattern was normal.
Resumo:
INTRODUCTION AND OBJECTIVES: Recurrent syncope has a significant impact on quality of life. The development of measurement scales to assess this impact that are easy to use in clinical settings is crucial. The objective of the present study is a preliminary validation of the Impact of Syncope on Quality of Life questionnaire for the Portuguese population. METHODS: The instrument underwent a process of translation, validation, analysis of cultural appropriateness and cognitive debriefing. A population of 39 patients with a history of recurrent syncope (>1 year) who underwent tilt testing, aged 52.1 ± 16.4 years (21-83), 43.5% male, most in active employment (n=18) or retired (n=13), constituted a convenience sample. The resulting Portuguese version is similar to the original, with 12 items in a single aggregate score, and underwent statistical validation, with assessment of reliability, validity and stability over time. RESULTS: With regard to reliability, the internal consistency of the scale is 0.9. Assessment of convergent and discriminant validity showed statistically significant results (p<0.01). Regarding stability over time, a test-retest of this instrument at six months after tilt testing with 22 patients of the sample who had not undergone any clinical intervention found no statistically significant changes in quality of life. CONCLUSIONS: The results indicate that this instrument is of value for assessing quality of life in patients with recurrent syncope in Portugal.
Resumo:
OBJECTIVE: Hereditary hemochromatosis (HH) is a disease caused by mutations in the Hfe gene characterised by systemic iron overload and associated with an increased prevalence of osteoarthritis (OA) but the role of iron overload in the development of OA is still undefined. To further understand the molecular mechanisms involved we have used a murine model of HH and studied the progression of experimental OA under mechanical stress. DESIGN: OA was surgically induced in the knee joints of 10-week-old C57BL6 (wild-type) mice and Hfe-KO mice. OA progression was assessed using histology, micro CT, gene expression and immunohistochemistry at 8 weeks after surgery. RESULTS: Hfe-KO mice showed a systemic iron overload and an increased iron accumulation in the knee synovial membrane following surgery. The histological OA score was significantly higher in the Hfe-KO mice at 8 weeks after surgery. Micro CT study of the proximal tibia revealed increased subchondral bone volume and increased trabecular thickness. Gene expression and immunohistochemical analysis showed a significant increase in the expression of matrix metallopeptidase 3 (MMP-3) in the joints of Hfe-KO mice compared with control mice at 8 weeks after surgery. CONCLUSIONS: HH was associated with an accelerated development of OA in mice. Our findings suggest that synovial iron overload has a definite role in the progression of HH-related OA