876 resultados para Maximal Aerobic Speed


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gurjao, ALD, Goncalves, R, de Moura, RF, and Gobbi, S. Acute effect of static stretching on rate of force development and maximal voluntary contraction in older women. J Strength Cond Res 23(7): 2149-2154, 2009-The purpose of this study was to investigate, in older women, the acute effect of static stretching (SS) on both muscle activation and force output. Twenty-three older women (64.6 +/- 7.1 yr) participated in the study. The maximal voluntary contraction (MVC), rate of force development (RFD) (50, 100, 150, and 200 ms relative to onset of muscular contraction), and peak RFD (PRFD) (the steepest slope of the curve during the first 200 ms) were tested under 2 randomly separate conditions: SS and control (C). Electromyographic (EMG) activity of the vastus medialis (VM), vastus lateralis (VL), and biceps femoris (BF) muscles also was assessed. The MVC was significantly lower (p < 0.05) in the 3 trials of SS when compared with the C condition (control: 925.0 +/- 50.9 N; trial 1 : 854.3 +/- 55.3 N; trial 2 : 863.1 +/- 52.2 N; and trial 3 : 877.5 +/- 49.9 N). PRFD showed a significant decrease only for the first 2 trials of SS when compared with the C condition (control: 2672.3 +/- 259.1 N/s; trial 1 : 2296.6 +/- 300.7 N/s; and trial 2 : 2197.9 +/- 246.3 N/s). However, no difference was found for RFD (50, 100, 150, and 200 ms relative to onset of muscular contraction). The EMG activity for VM, VL, and BF was not significantly different between the C and SS conditions. In conclusion, the older women's capacity to produce muscular force decreased after their performance of SS exercises. The mechanisms responsible for this effect do not appear to be related to muscle activation. Thus, if flexibility is to be trained, it is recommended that SS does not occur just before the performance of activities that require high levels of muscular force.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: O objetivo deste estudo foi analisar os efeitos da corrida contínua prolongada realizada na intensidade correspondente ao início do acúmulo do lactato no sangue (OBLA) sobre o torque máximo dos extensores do joelho analisado em diferentes tipos de contração e velocidade de movimento em indivíduos ativos. MÉTODO: Oito indivíduos do gênero masculino (23,4 ± 2,1 anos; 75,8 ± 8,7 kg; 171,1 ± 4,5 cm) participaram deste estudo. Primeiramente, os sujeitos realizaram um teste incremental até a exaustão voluntária para determinar a velocidade correspondente ao OBLA. Posteriormente, os sujeitos retornaram ao laboratório em duas ocasiões, separadas por pelo menos sete dias, para realizar 5 contrações isocinéticas máximas para os extensores do joelho em duas velocidades angulares (60 e 180º.s-1) sob as condições excêntrica (PTE) e concêntrica (PTC). Uma sessão foi realizada após um período de aquecimento padronizado (5 min a 50%VO2max). A outra sessão foi realizada após uma corrida contínua no OBLA até a exaustão voluntária. Essas sessões foram executadas em ordem randômica. RESULTADOS: Houve redução significante do PTC somente a 60º.s-1 (259,0 ± 46,4 e 244,0 ± 41,4 N.m). Entretanto, a redução do PTE foi significante a 60º.s-1 (337,3 ± 43,2 e 321,7 ± 60,0 N.m) e 180º.s-1 (346,1 ± 38,0 e 319,7 ± 43,6 N.m). As reduções relativas da força após o exercício de corrida foram significantemente diferentes entre os tipos de contração somente a 180º.s-1. CONCLUSÃO: Podemos concluir que, em indivíduos ativos, a redução no torque máximo após uma corrida contínua prolongada no OBLA pode ser dependente do tipo de contração e da velocidade angular.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We quantified the oxygen uptake rates ((V) over dot O-2) and time spent, during the constriction, inspection, and ingestion of prey of different relative sizes, by the prey-constricting boid snake Boa constrictor amarali. Time spent in prey constriction varied from 7.6 to 16.3 min, and (V) over dot O-2 during prey constriction increased 6.8-fold above resting values. This was the most energy expensive predation phase but neither time spent nor metabolic rate during this phase were correlated with prey size. Similarly, prey size did not affect the (V) over dot O-2 or duration of prey inspection. Prey ingestion time, on the other hand, increased linearly with prey size although (V) over dot O-2 during this phase, which increased 4.9-fold above resting levels, was not affected by prey size. The increase in mechanical difficulty of ingesting larger prey, therefore, was associated with longer ingestion times rather than proportional increases in the level of metabolic effort. The data indicate that prey constriction and ingestion are largely sustained by glycolysis and the intervening phase of prey inspection may allow recovery between these two predatory phases with high metabolic demands. The total amount of energy spent by B. c. amarali to constrict, inspect, and ingest prey of sizes varying from 5 to 40% of snake body mass varied inversely from 0.21 to 0.11% of the energy assimilated from the prey, respectively. Thus, prey size was not limited by the energetic cost of predation. on the contrary, snakes feeding on larger prey were rewarded with larger energetic returns, in accordance with explanations of the evolution of snake feeding specializations. (C) 2002 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by oneway ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C ( 0.56) for Group 1, 0.84 degrees C (0.55) for Group II, and 3.00 degrees C (1.34) for Group III. There were no statistically significant differences (p > 0.05) between Groups I and II, but both of them differed significantly from Group III (p < 0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of cutting initiation location and cutting speed on the bond strength between resin cement and feldspathic ceramic.Materials and Methods: Thirty-six blocks (6.4 x 6.4 x 4.8 mm) of ceramic (Vita VM7) were produced. The ceramic surfaces were etched with 10% hydrofluoric acid gel for 60 s and then silanized. Each ceramic block was placed in a silicon mold with the treated surface exposed. A resin cement (Variolink II) was injected into the mold over the treated surface and polymerized. The resin cement-ceramic blocks were divided into two groups according to experimental conditions: a) cutting initiation location - resin cement, ceramic and interface; and b) cutting speed - 10,000, 15,000, and 20,000 rpm. The blocks were sectioned to achieve non-trimmed bar specimens. The microtensile test was performed in a universal testing machine (1 mm/min). The failure modes were examined using an optical light microscope and SEM. Bond strength results were analyzed using one-way ANOVA and Tukey's test (alpha = 0.05).Results: Significant influences of cutting speed and initiation location on bond strength (p < 0.05) were observed. The highest mean was achieved for specimens cut at 15,000 rpm at the interface (15.12 +/- 5.36 MPa). The lowest means were obtained for specimens cut at the highest cutting speed in resin cement (8.50 +/- 3.27 MPa), and cut at the lowest cutting speed in ceramic (8.60 +/- 2.65MPa). All groups showed mainly mixed failure (75% to 100%).Conclusion: The cutting speed and initiation location are important factors that should be considered during specimen preparation for microtensile bond strength testing, as both may influence the bond strength results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. The use of ultrasonic tips has become an alternative for cavity preparation. However, there are concerns about this type of device, particularly with respect to intrapulpal temperatures and cavity preparation time.Purpose. The purpose of this study was to analyze pulpal temperature increases generated by an ultrasonic cavity preparation with chemical vapor deposition (CVD) tips, in comparison to preparation with a high-speed handpiece with a diamond rotary cutting instrument. The time required to complete the cavity preparation with each system was also evaluated.Material and methods. Thermocouples were positioned in the pulp chamber of 20 extracted human third molars. Slot-type cavities (3 x 3 x 2 mm) were prepared on the buccal and the lingual surfaces of each tooth. The test groups were: high-speed cavity preparation with diamond rotary cutting instruments (n = 20) and ultrasonic cavity preparation with CVD points (n = 20). During cavity preparation, the increases In pulpal temperature, and the time required for the preparation, were recorded and analyzed by Student's t test for paired samples (alpha = .05).Results. The average pulpal temperature increases were 4.3 degrees C for the high-speed preparation and 3.8 degrees C for the ultrasonic preparation, which were statistically similar (P = .052). However, significant differences were found (P < .001) for the time expended (3.3 minutes for the high-speed bur and 13.77 minutes for the ultrasound device).Conclusions. The intrapulpal temperatures produced during cavity preparation by ultrasonic tips versus high-speed bur preparation were similar. However, the use of the ultrasonic device required 4 times longer for the completion of a cavity preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By exploring the relationship between the propagation of electromagnetic waves in a gravitational field and the light propagation in a refractive medium, it is shown that, in the presence of a positive cosmological constant, the velocity of light will be smaller than its special relativity value. Then, restricting again to the domain of validity of geometrical optics, the same result is obtained in the context of wave optics. It is argued that this phenomenon and the anisotropy in the velocity of light in a gravitational field are produced by the same mechanism.