999 resultados para Macrophyte Monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research of power-line communications has been concentrated on home automation, broadband indoor communications and broadband data transfer in a low voltage distribution network between home andtransformer station. There has not been carried out much research work that is focused on the high frequency characteristics of industrial low voltage distribution networks. The industrial low voltage distribution network may be utilised as a communication channel to data transfer required by the on-line condition monitoring of electric motors. The advantage of using power-line data transfer is that it does not require the installing of new cables. In the first part of this work, the characteristics of industrial low voltage distribution network components and the pilot distribution network are measured and modelled with respect topower-line communications frequencies up to 30 MHz. The distributed inductances, capacitances and attenuation of MCMK type low voltage power cables are measured in the frequency band 100 kHz - 30 MHz and an attenuation formula for the cables is formed based on the measurements. The input impedances of electric motors (15-250 kW) are measured using several signal couplings and measurement based input impedance model for electric motor with a slotted stator is formed. The model is designed for the frequency band 10 kHz - 30 MHz. Next, the effect of DC (direct current) voltage link inverter on power line data transfer is briefly analysed. Finally, a pilot distribution network is formed and signal attenuation in communication channels in the pilot environment is measured. The results are compared with the simulations that are carried out utilising the developed models and measured parameters for cables and motors. In the second part of this work, a narrowband power-line data transfer system is developed for the data transfer ofon-line condition monitoring of electric motors. It is developed using standardintegrated circuits. The system is tested in the pilot environment and the applicability of the system for the data transfer required by the on-line condition monitoring of electric motors is analysed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of industrial crystallization is to obtain a crystalline product which has the desired crystal size distribution, mean crystal size, crystal shape, purity, polymorphic and pseudopolymorphic form. Effective control of the product quality requires an understanding of the thermodynamics of the crystallizing system and the effects of operation parameters on the crystalline product properties. Therefore, obtaining reliable in-line information about crystal properties and supersaturation, which is the driving force of crystallization, would be very advantageous. Advanced techniques, such asRaman spectroscopy, attenuated total reflection Fourier transform infrared (ATR FTIR) spectroscopy, and in-line imaging techniques, offer great potential for obtaining reliable information during crystallization, and thus giving a better understanding of the fundamental mechanisms (nucleation and crystal growth) involved. In the present work, the relative stability of anhydrate and dihydrate carbamazepine in mixed solvents containing water and ethanol were investigated. The kinetics of the solvent mediated phase transformation of the anhydrate to hydrate in the mixed solvents was studied using an in-line Raman immersion probe. The effects of the operation parameters in terms of solvent composition, temperature and the use of certain additives on the phase transformation kineticswere explored. Comparison of the off-line measured solute concentration and the solid-phase composition measured by in-line Raman spectroscopy allowedthe identification of the fundamental processes during the phase transformation. The effects of thermodynamic and kinetic factors on the anhydrate/hydrate phase of carbamazepine crystals during cooling crystallization were also investigated. The effect of certain additives on the batch cooling crystallization of potassium dihydrogen phosphate (KDP) wasinvestigated. The crystal growth rate of a certain crystal face was determined from images taken with an in-line video microscope. An in-line image processing method was developed to characterize the size and shape of thecrystals. An ATR FTIR and a laser reflection particle size analyzer were used to study the effects of cooling modes and seeding parameters onthe final crystal size distribution of an organic compound C15. Based on the obtained results, an operation condition was proposed which gives improved product property in terms of increased mean crystal size and narrowersize distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans le cadre de la planification de l'entraînement d'un athlète, l'affûtage précompétitif consiste à réduire les charges d'entraînement et éliminer le stress des séances précédentes afin d'optimiser les performances futures. Il existe des outils pour analyser les changements physiologiques qui se manifestent dans l'organisme des sportifs pendant cette période et qui sont responsables du gain de performance. L'analyse des indices corporels par bioimpédancemétrie pourrait constituer un outil simple et non invasif pour monitorer les performances et l'entraînement des sportifs d'élites. Méthodologie : Treize nageurs élites ont été analysés sur trois affûtages (T1, N=7 ; T2, N=6 et T3, N=8) qui précèdent trois objectifs nationaux majeurs. Un bioimpédancemètre multifréquence, le Z-Métrix, a été utilisé pour mesurer les indices avant et après l'affûtage. Sur le même principe, les performances des sujets ont été comparées entre la compétition qui suit l'affûtage et une compétition précédente sans affûtage. Pour compléter l'analyse, la charge d'entraînement pendant l'affûtage a été quantifiée puis comparée à la charge qui précède. L'évolution des indices corporels pourra donc être mise en relation avec les différences de performance et la variation de la charge d'entraînement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow structures above vegetation canopies have received much attention within terrestrial and aquatic literature. This research has led to a good process understanding of mean and turbulent canopy flow structure. However, much of this research has focused on rigid or semi-rigid vegetation with relatively simple morphology. Aquatic macrophytes differ from this form, exhibiting more complex morphologies, predominantly horizontal posture in the flow and a different force balance. While some recent studies have investigated such canopies, there is still the need to examine the relevance and applicability of general canopy layer theory to these types of vegetation. Here, we report on a range of numerical experiments, using both semi-rigid and highly flexible canopies. The results for the semi-rigid canopies support existing canopy layer theory. However, for the highly flexible vegetation, the flow pattern is much more complex and suggests that a new canopy model may be required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our efforts are directed towards the understanding of the coscheduling mechanism in a NOW system when a parallel job is executed jointly with local workloads, balancing parallel performance against the local interactive response. Explicit and implicit coscheduling techniques in a PVM-Linux NOW (or cluster) have been implemented. Furthermore, dynamic coscheduling remains an open question when parallel jobs are executed in a non-dedicated Cluster. A basis model for dynamic coscheduling in Cluster systems is presented in this paper. Also, one dynamic coscheduling algorithm for this model is proposed. The applicability of this algorithm has been proved and its performance analyzed by simulation. Finally, a new tool (named Monito) for monitoring the different queues of messages in such an environments is presented. The main aim of implementing this facility is to provide a mean of capturing the bottlenecks and overheads of the communication system in a PVM-Linux cluster.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A variety of technologies have been developed to assist decision-making during the management of patients with acute brain injury who require intensive care. A large body of research has been generated describing these various technologies. The Neurocritical Care Society (NCS) in collaboration with the European Society of Intensive Care Medicine (ESICM), the Society for Critical Care Medicine (SCCM), and the Latin America Brain Injury Consortium (LABIC) organized an international, multidisciplinary consensus conference to perform a systematic review of the published literature to help develop evidence-based practice recommendations on bedside physiologic monitoring. This supplement contains a Consensus Summary Statement with recommendations and individual topic reviews on physiologic processes important in the care of acute brain injury. In this article we provide the evidentiary tables for select topics including systemic hemodynamics, intracranial pressure, brain and systemic oxygenation, EEG, brain metabolism, biomarkers, processes of care and monitoring in emerging economies to provide the clinician ready access to evidence that supports recommendations about neuromonitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Careful patient monitoring using a variety of techniques including clinical and laboratory evaluation, bedside physiological monitoring with continuous or non-continuous techniques and imaging is fundamental to the care of patients who require neurocritical care. How best to perform and use bedside monitoring is still being elucidated. To create a basic platform for care and a foundation for further research the Neurocritical Care Society in collaboration with the European Society of Intensive Care Medicine, the Society for Critical Care Medicine and the Latin America Brain Injury Consortium organized an international, multidisciplinary consensus conference to develop recommendations about physiologic bedside monitoring. This supplement contains a Consensus Summary Statement with recommendations and individual topic reviews as a background to the recommendations. In this article, we highlight the recommendations and provide additional conclusions as an aid to the reader and to facilitate bedside care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Spanish Government has established post-market environmental monitoring (PMEM) as mandatory for genetically modified (GM) crop varieties cultivated in Spain. In order to comply with this regulation, effects of Bt maize varieties derived from the event MON810 on the predatory fauna were monitored for two years in northeast and central Spain. The study was carried out with a randomized block design in maize fields of 3-4 ha on which the abundance of plant-dwelling predators and the activity-density of soil-dwelling predators in Bt vs. non-Bt near-isogenic varieties were compared. To this end, the plots were sampled by visual inspection of a certain number of plants and pitfall traps 6 or 7 times throughout two seasons. No significant differences in predator densities on plants were found between Bt and non-Bt varieties. In the pitfall traps, significant differences between the two types of maize were found only in Staphylinidae, in which trap catches in non-Bt maize were higher than in Bt maize in central Spain. Based on the statistical power of the assays, surrogate arthropods for PMEM purposes are proposed; Orius spp. and Araneae for visual sampling and Carabidae, Araneae, and Staphylinidae for pitfall trapping. The other predator groups recorded in the study, Nabis sp. and Coccinellidae in visual sampling and Dermaptera in pitfall trapping, gave very poor power results. To help to establish a standardized protocol for PMEM of genetically modified crops, the effect-detecting capacity with a power of 0.8 of each predator group is given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maintenance of adequate oxygenation is a mainstay of intensive care, however, recommendations on the safety, accuracy, and the potential clinical utility of invasive and non-invasive tools to monitor brain and systemic oxygenation in neurocritical care are lacking. A literature search was conducted for English language articles describing bedside brain and systemic oxygen monitoring in neurocritical care patients from 1980 to August 2013. Imaging techniques e.g., PET are not considered. A total of 281 studies were included, the majority described patients with traumatic brain injury (TBI). All tools for oxygen monitoring are safe. Parenchymal brain oxygen (PbtO2) monitoring is accurate to detect brain hypoxia, and it is recommended to titrate individual targets of cerebral perfusion pressure (CPP), ventilator parameters (PaCO2, PaO2), and transfusion, and to manage intracranial hypertension, in combination with ICP monitoring. SjvO2 is less accurate than PbtO2. Given limited data, NIRS is not recommended at present for adult patients who require neurocritical care. Systemic monitoring of oxygen (PaO2, SaO2, SpO2) and CO2 (PaCO2, end-tidal CO2) is recommended in patients who require neurocritical care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this project was to gather all the counters which are used on HSPA performance monitoring. The main purpose was to create a compact packet of HSPA performance counters and radio network monitoring which Ericsson's employees can then use in their daily work. The study includes a short introduction to the architecture of the 3G-radio access network. The HSPA technology and HSPA performance are presented including a functional description of performance counters and KPIs, which are used for performance management and monitoring. The theory part of the study also covers an overview of performance management in OSS-RC. The final part of the study covers an overview of the performance management tools, in-troducing how the counters are represented in these interfaces. MOShell and OSS-RC are tools used in this study. Tools were selected because the MOShell is Ericsson's inter-nal management tool and OSS-RC is a tool designed for customers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study aimed to survey current practices in European epilepsy monitoring units (EMUs) with emphasis on safety issues. METHODS: A 37-item questionnaire investigating characteristics and organization of EMUs, including measures for prevention and management of seizure-related serious adverse events (SAEs), was distributed to all identified European EMUs plus one located in Israel (N=150). RESULTS: Forty-eight (32%) EMUs, located in 18 countries, completed the questionnaire. Epilepsy monitoring unit beds are 1-2 in 43%, 3-4 in 34%, and 5-6 in 19% of EMUs; staff physicians are 1-2 in 32%, 3-4 in 34%, and 5-6 in 19% of EMUs. Personnel operating in EMUs include epileptologists (in 69% of EMUs), clinical neurophysiologists trained in epilepsy (in 46% of EMUs), child neurologists (in 35% of EMUs), neurology and clinical neurophysiology residents (in 46% and in 8% of EMUs, respectively), and neurologists not trained in epilepsy (in 27% of EMUs). In 20% of EMUs, patients' observation is only intermittent or during the daytime and primarily carried out by neurophysiology technicians and/or nurses (in 71% of EMUs) or by patients' relatives (in 40% of EMUs). Automatic detection systems for seizures are used in 15%, for body movements in 8%, for oxygen desaturation in 33%, and for ECG abnormalities in 17% of EMUs. Protocols for management of acute seizures are lacking in 27%, of status epilepticus in 21%, and of postictal psychoses in 87% of EMUs. Injury prevention consists of bed protections in 96% of EMUs, whereas antisuffocation pillows are employed in 21%, and environmental protections in monitoring rooms and in bathrooms are implemented in 38% and in 25% of EMUs, respectively. The most common SAEs were status epilepticus reported by 79%, injuries by 73%, and postictal psychoses by 67% of EMUs. CONCLUSIONS: All EMUs have faced different types of SAEs. Wide variation in practice patterns and lack of protocols and of precautions to ensure patients' safety might promote the occurrence and severity of SAEs. Our findings highlight the need for standardized and shared protocols for an effective and safe management of patients in EMUs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Multimodal monitoring (MMM) is routinely applied in neurointensive care. Unfortunately, there is no robust evidence on which MMM-derived physiologic variables are the most clinically relevant, how and when they should be monitored, and whether MMM impacts outcome. The complexity is even higher because once the data are continuously collected, interpretation and integration of these complex physiologic events into targeted individualized care is still embryonic. RECENT FINDINGS: Recent clinical investigation mainly focused on intracranial pressure, perfusion of the brain, and oxygen availability along with electrophysiology. Moreover, a series of articles reviewing the available evidence on all the MMM tools, giving practical recommendations for bedside MMM, has been published, along with other consensus documents on the role of neuromonitoring and electroencephalography in this setting. SUMMARY: MMM allows comprehensive exploration of the complex pathophysiology of acute brain damage and, depending on the different configuration of the pathological condition we are treating, the application of targeted individualized care. Unfortunately, we still lack robust evidence on how to better integrate MMM-derived information at the bedside to improve patient management. Advanced informatics is promising and may provide us a supportive tool to interpret physiologic events and guide pathophysiological-based therapeutic decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The control of the right application of medical protocols is a key issue in hospital environments. For the automated monitoring of medical protocols, we need a domain-independent language for their representation and a fully, or semi, autonomous system that understands the protocols and supervises their application. In this paper we describe a specification language and a multi-agent system architecture for monitoring medical protocols. We model medical services in hospital environments as specialized domain agents and interpret a medical protocol as a negotiation process between agents. A medical service can be involved in multiple medical protocols, and so specialized domain agents are independent of negotiation processes and autonomous system agents perform monitoring tasks. We present the detailed architecture of the system agents and of an important domain agent, the database broker agent, that is responsible of obtaining relevant information about the clinical history of patients. We also describe how we tackle the problems of privacy, integrity and authentication during the process of exchanging information between agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In acute respiratory failure, arterial blood gas analysis (ABG) is used to diagnose hypercapnia. Once non-invasive ventilation (NIV) is initiated, ABG should at least be repeated within 1 h to assess PaCO2 response to treatment in order to help detect NIV failure. The main aim of this study was to assess whether measuring end-tidal CO2 (EtCO2) with a dedicated naso-buccal sensor during NIV could predict PaCO2 variation and/or PaCO2 absolute values. The additional aim was to assess whether active or passive prolonged expiratory maneuvers could improve the agreement between expiratory CO2 and PaCO2. METHODS: This is a prospective study in adult patients suffering from acute hypercapnic respiratory failure (PaCO2 ≥ 45 mmHg) treated with NIV. EtCO2 and expiratory CO2 values during active and passive expiratory maneuvers were measured using a dedicated naso-buccal sensor and compared to concomitant PaCO2 values. The agreement between two consecutive values of EtCO2 (delta EtCO2) and two consecutive values of PaCO2 (delta PaCO2) and between PaCO2 and concomitant expiratory CO2 values was assessed using the Bland and Altman method adjusted for the effects of repeated measurements. RESULTS: Fifty-four datasets from a population of 11 patients (8 COPD and 3 non-COPD patients), were included in the analysis. PaCO2 values ranged from 39 to 80 mmHg, and EtCO2 from 12 to 68 mmHg. In the observed agreement between delta EtCO2 and deltaPaCO2, bias was -0.3 mmHg, and limits of agreement were -17.8 and 17.2 mmHg. In agreement between PaCO2 and EtCO2, bias was 14.7 mmHg, and limits of agreement were -6.6 and 36.1 mmHg. Adding active and passive expiration maneuvers did not improve PaCO2 prediction. CONCLUSIONS: During NIV delivered for acute hypercapnic respiratory failure, measuring EtCO2 using a dedicating naso-buccal sensor was inaccurate to predict both PaCO2 and PaCO2 variations over time. Active and passive expiration maneuvers did not improve PaCO2 prediction. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01489150.