760 resultados para MECHANICAL OVERLOAD


Relevância:

20.00% 20.00%

Publicador:

Resumo:

New titanium alloys have been developed with the aim of utilizing materials with better properties for application as biomaterials, and Ti-Zr system alloys are among the more promising of these. In this paper, the influence of zirconium concentrations on the structure, microstructure, and selected mechanical properties of Ti-Zr alloys is analyzed. After melting and swaging, the samples were characterized through chemical analysis, density measurements, X-ray diffraction, optical microscopy, Vickers microhardness, and elasticity modulus. In-vitro cytotoxicity tests were performed on cultured osteogenic cells. The results showed the formation essentially of the α′ phase (with hcp structure) and microhardness values greater than cp-Ti. The elasticity modulus of the alloys was sensitive to the zirconium concentrations while remaining within the range of values of conventional titanium alloys. The alloys presented no cytotoxic effects on osteoblastic cells in the studied conditions. © 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Várias plantas podem provocar algum tipo de injúria mecânica. Entre elas as que causam traumatismo da pele ou mucosas, e as que causam alterações do sistema digestório, incluindo obstrução esofágica, sobrecarga ruminal e obstrução intestinal. Neste trabalho são revisadas algumas plantas que causam essas alterações e é descrito um surto de injúria mecânica causada por Stipa spp. (flechilha) em ovinos no Uruguai. Os animais, principalmente os cordeiros, apresentavam grande quantidade dos frutos de flechilha incrustadas na lã e alguns desses se introduziam na pele, panículo adiposo e músculo cutâneo do tronco causando dermatite e paniculite multifocal difusa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho objetivou adaptar um procedimento mecânico para o isolamento de folículos pré-antrais a partir de ovários de Cebus apella. Para isso, foi testado o efeito do intervalo de cortes seriados do tissue chopper sobre o número de folículos pré-antrais isolados a partir de ovários (n=6) de três fêmeas de C. apella, duas pré-púberes e uma adulta. Os ovários foram divididos em quatro partes iguais e fragmentados com auxílio de um tissue chopper, ajustado para a realização de secções seriadas a intervalos de 250, 500, 750 e 1000µm, respectivamente. Os folículos isolados foram contados em câmara de Neubauer e classificados em primordiais, primários e secundários. O número (média ± EP) de folículos pré-antrais isolados de 1/4 de ovário variou de 68.330+17.590, no intervalo de corte de 1.000µm, a 300.830+111.460, no intervalo de corte de 500µm, o de melhores resultados. O diâmetro médio dos folículos pré-antrais isolados variou de 11,6µm a 27, 8µm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mechanical harvesting is an important stage in the production process of soybeans and, in this process; the loss of a significant number of grains is common. Despite the existence of mechanisms to monitor these losses, it is still essential to use sampling methods to quantify them. Assuming that the size of the sample area affects the reliability and variability between samples in quantifying losses, this paper aimed to analyze the variability and feasibility of using different sizes of sample area (1, 2 and 3 m²) in quantifying losses in the mechanical harvesting of soybeans. Were sampled 36 sites and the cutting losses, losses by other mechanisms of the combine and total losses were evaluated, as well as the water content in seeds, straw distribution and crop productivity. Data were subjected to statistical analysis (descriptive statistics and analysis of variance) and Statistical Control Process (SCP). The coefficients of variation were similar for the three frames available. Combine losses showed stable behavior, whereas cutting losses and total losses showed unstable behavior. The frame size did not affect the quantification and variability of losses in the mechanical harvesting of soybeans, thus a frame of 1 m² can be used for determining losses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the effects of swimming training (ST) on femoral mechanical and structural properties in ovariectomized female rats. Female Wistar rats [age = 20 weeks; body weight (BW) = 271,42 +/- 17,6 g] were subjected to ovariectomy (OVX) or laparotomy (SHAM) and allocated to one of the following groups: swimming OVX (SO, n=12), control OVX (CO, n=12), swimming SHAM (SS, n=12) and control SHAM (CS, n=12). Fifteen days after surgery SO and SS groups were subjected to a ST (60 min/day, 5 days/week, overload of 3% of BW) for 10 weeks. Alkalin phosfatase was reduced in OVX as compared to SHAM (18,87 pg/mL vs. 53,93 pg/mL, respectively), but not altered by ST. Animals SHAM showed more cancellous bone than OVX (255,50 +/- 38,27 vs 288,75 +/- 39,63 points, respectively). Exercised animals exhibited more cancellous bone than controls (292,00 +/- 33,54 vs 251,54 +/- 38,99 points, respectively) in this region and in the grater trochanter (281,50 +/- 34,42 vs 237,23 +/- 53,03 points; respectively). Bone mineral density and cortical bone in the femur midshaft were not altered either by OVX or ST. The maximum force and thoughness of the femoral neck and midshaft were not affected either by OVX or ST. It was concluded that ST benefits cancellous bone mass in the femoral proximal region (i.e. femoral neck and greater trochanter), independently of ovariectomy, which did not reflect in improved mechanical properties either in the femoral neck or midshaft.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study aimed to evaluate the survival probability of four narrow-diameter implant systems when subjected to fatigue loading. Materials and Methods: Seventy-two narrow-diameter implants to be restored with single-unit crowns were divided into four groups (n = 18): Astra Tech (3.5-mm diameter), with a standard connection (ASC); BioHorizon (3.4-mm diameter), with a standard connection (BSC); Intra-Lock (3.4-mm diameter), with a standard multilobular connection (ISC); and Intra-Lock (3.4-diameter), with a modified square connection (IMC). The corresponding abutments were screwed onto the implants, and standardized metal crowns (maxillary central incisors) were cemented and subjected to step-stress accelerated life testing in water. Use-level probability Weibull curves and reliability for 100,000 cycles at 150 and 200 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used to access the failure modes. Results: The calculated survival probability for 100,000 cycles at 150 N was approximately 93% in group ASC, 98% in group BSC, 94% in group ISC, and 99% in group IMC. At 200 N, the survival rate was estimated to be approximately < 0.1% for ASC, 77% for BSC, 34% for ISC, and 93% for IMC. Abutment screw fracture was the main failure mode for all groups. Conclusions: Although the probability of survival was not significantly different among systems at a load of 150 N, a significant decrease was observed at 200 N for all groups except IMC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The physical properties of novel thermoplastic random copolyesters [-(CH2)(n)-COO-/-(CH2)(n)-COO-](x) made of long (n=12) and medium (n=8) chain length -hydroxyfatty esters [HO-(CH2)(n)-COOCH3] derived from bio-based vegetable oil feedstock are described. Poly(-hydroxy tridecanoate/-hydroxy nonanoate) P(-Me13-/-Me9-) random copolyesters (M-n=11,000-18,500 g/mol) with varying molar ratios were examined by TGA, DSC, DMA and tensile analysis, and WAXD. For the whole range of P(-Me13-/-Me9-) compositions, the WAXD data indicated an orthorhombic polyethylene-like crystal packing. Their melting characteristics, determined by DSC, varied with composition suggesting an isomorphic cocrystallization behavior. TGA of the P(-Me13-/-Me9-)s indicated improved thermal stability determined by their molar compositions. The glass transition temperature, investigated by DMA, was also found to vary with composition. The crystallinities of P(-Me13-/-Me9-)s however, were unaffected by the composition. The stiffness (Young's modulus) of these materials was found to be related to their degrees of crystallinity. (c) 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2014, 131, 40492.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)