983 resultados para Low-pass filter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dependência energética das grandes economias mundiais, alertaram o mundo para a necessidade de mudar o comportamento relativo ao consumo de energia. O sector dos edifícios representa 40% dos consumos globais de energia na União Europeia, já no panorama nacional, o sector dos edifícios representa 28% dos consumos globais da energia, constituindo uma parte significativa no consumo global de energia, sendo portanto, essencial avaliar o desempenho energético dos edifícios, no sentido de promover a sua eficiência energética e beneficiar do grande potencial de economia de energia. Portugal à luz das linhas de orientação da União Europeia com o objectivo de instigar o aumento da eficiência energética nos edifícios, lançou o programa nacional para a eficiência energética nos Edifícios (P3E). Posteriormente, da transposição da Directiva 2002/91/CE para a ordem jurídica nacional surgiu o SCE, o RCCTE e o RSECE. Já em 2013, com a necessidade de transpor para a ordem da jurídica nacional a Directiva n.º 2010/31/EU, surge o Decreto-Lei n.º 118/2013, reunindo num só diploma o SCE, o REH e o RECS, promovendo uma revisão da legislação nacional, garantindo e promovendo a melhoria do desempenho energético dos edifícios. Através da presente dissertação, pretende-se avaliar o desempenho energético de uma pequena fracção de serviços existente tendo por base a metodologia regulamentar revogada do RSECE e a vigente metodologia regulamentar do RECS. Após apresentação dos dois regulamentos e da identificação das principais diferenças entre as duas metodologias regulamentares, procedeu-se ao enquadramento da fracção em estudo no âmbito de aplicação do RSECE e do RECS. Segundo os dois regulamentos a fracção não está sujeita a requisitos mínimos de qualidade térmica, nem a quaisquer requisitos energéticos e de eficiência dos sistemas técnicos, ao tratar-se de uma pequena fracção de serviços existente. Recorrendo ao software DesignBuilder, gerou-se o modelo da fracção em estudo, que através da simulação dinâmica multizona permitiu obter os consumos de energia anuais e a sua desagregação por utilização final. A partir dos consumos energia, determinaram-se os indicadores de eficiência energética de acordo com as duas metodologias, permitindo deste modo, proceder à classificação energética da fracção em estudo. De acordo com o RSECE a fracção em estudo obteve a classificação D, já segundo o RECS alcançou a classe C. Para aumentar a eficiência energética da fracção e consequentemente diminuir o consumo energético, foi proposto proceder à substituição das lâmpadas existentes por lâmpadas tubulares de tecnologia LED e à substituição do sistema de ventilação mecânico por um sistema de ventilação dimensionado para os novos valores de caudal de ar novo regulamentares. Com a implementação destas duas medidas a fracção em estudo melhoraria a sua classificação energética, exigindo um investimento baixo e apresentando um período de retorno de 1 ano e 5 meses. Segundo o RSECE passaria para a classe B, e aplicando a metodologia regulamentar do RECS alcançaria a classe B-.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to determine Schistosoma mansoni infection rates in Biomphalaria tenagophila and B. straminea, low stringency polymerase chain reaction (LS-PCR) technique was used as a complementary method to light exposure technique. LS-PCR has already been standardized in our laboratory to detect the trematode DNA in B. glabrata. Higher S. mansoni infection rates were detected using conventional method and LS-PCR. The parasite DNA profile was detected in both species after 7-day exposure to miracidia, using LS-PCR. This technique enables early detection of schistosomiasis transmission focuses, in endemic areas, before the beginning of cercariae shedding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Response to treatment with antimonial drugs varies considerably depending on the parasite strain involved, immune status of the patient and clinical form of the disease. Therapeutic regimens with this first line drug have been frequently modified both, in dose and duration of therapy. A regimen of 20 mg/kg/day of pentavalent antimony (Sb5+) during four weeks without an upper limit on the daily dose is currently recommended for mucosal disease ("espundia"). Side-effects with this dose are more marked in elderly patients, more commonly affected by this form of leishmaniasis. According to our experience, leishmaniasis in Rio de Janeiro responds well to antimony and, in cutaneous disease, high cure rates are obtained with 5 mg/kg/day of Sb5+ during 30 to 45-days. In this study a high rate of cure (91.4%) employing this dose was achieved in 36 patients with mild disease in this same geographic region. Side-effects were reduced and no antimony refractoriness was noted with subsequent use of larger dose in patients that failed to respond to initial schedule.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevalence of TT virus (TTV) infection was investigated by Polymerase Chain Reaction (PCR) in low- (blood donors and healthy children/adolescents) and high-risk (hemophiliacs) groups from São Paulo, Brazil. Primers based on the untranslated region (UTR) of the viral genome proved to be much more ubiquitous, leading to much higher frequencies for both groups ( > or = 81%) than the earlier N22-PCR directed to the open reading frame 1 (blood donors, 5.5%, and hemophiliacs, 42.3%). The UTR-PCR also revealed an interesting profile for healthy children/adolescents: very high prevalence at the early years and significant decrease in male teenagers. The N22-PCR, in turn, demonstrated higher frequency in hemophiliacs treated with fresh blood products (58%), than in those treated with virus-inactivated clotting factors (9.4%) and blood donors (5.5%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ergonomic interventions such as increased scheduled breaks or job rotation have been proposed to reduce upper limb muscle fatigue in repetitive low-load work. This review was performed to summarize and analyze the studies investigating the effect of job rotation and work-rest schemes, as well as, work pace, cycle time and duty cycle, on upper limb muscle fatigue. The effects of these work organization factors on subjective fatigue or discomfort were also analyzed. This review was based on relevant articles published in PubMed, Scopus and Web of Science. The studies included in this review were performed in humans and assessed muscle fatigue in upper limbs. 14 articles were included in the systematic review. Few studies were performed in a real work environment and the most common methods used to assess muscle fatigue were surface electromyography (EMG). No consistent results were found related to the effects of job rotation on muscle activity and subjective measurements of fatigue. Rest breaks had some positive effects, particularly in perceived discomfort. The increase in work pace reveals a higher muscular load in specific muscles. The duration of experiments and characteristics of participants appear to be the factors that most have influenced the results. Future research should be focused on the improvement of the experimental protocols and instrumentation, in order to the outcomes represent adequately the actual working conditions. Relevance to industry: Introducing more physical workload variation in low-load repetitive work is considered an effective ergonomic intervention against muscle fatigue and musculoskeletal disorders in industry. Results will be useful to identify the need of future research, which will eventually lead to the adoption of best industrial work practices according to the workers capabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The European Union Emissions Trading Scheme (EU ETS) is a cornerstone of the European Union's policy to combat climate change and its key tool for reducing industrial greenhouse gas emissions cost-effectively. The purpose of the present work is to evaluate the influence of CO2 opportunity cost on the Spanish wholesale electricity price. Our sample includes all Phase II of the EU ETS and the first year of Phase III implementation, from January 2008 to December 2013. A vector error correction model (VECM) is applied to estimate not only long-run equilibrium relations, but also short-run interactions between the electricity price and the fuel (natural gas and coal) and carbon prices. The four commodities prices are modeled as joint endogenous variables with air temperature and renewable energy as exogenous variables. We found a long-run relationship (cointegration) between electricity price, carbon price, and fuel prices. By estimating the dynamic pass-through of carbon price into electricity price for different periods of our sample, it is possible to observe the weakening of the link between carbon and electricity prices as a result from the collapse on CO2 prices, therefore compromising the efficacy of the system to reach proposed environmental goals. This conclusion is in line with the need to shape new policies within the framework of the EU ETS that prevent excessive low prices for carbon over extended periods of time.