987 resultados para Liquid infusion techniques


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucose control is the cornerstone of Diabetes Mellitus (DM) treatment. Although self-regulation using capillary glycemia (SRCG) still remains the best procedure in clinical practice, continuous glucose monitoring systems (CGM) offer the possibility of continuous and dynamic assessment of interstitial glucose concentration. CGM systems have the potential to improve glycemic control while decreasing the incidence of hypoglycemia but the efficiency, compared with SRCG, is still debated. CGM systems have the greatest potential value in patients with hypoglycemic unawareness and in controlling daily fluctuations in blood glucose. The implementation of continuous monitoring in the standard clinical setting has not yet been established but a new generation of open and close loop subcutaneous insulin infusion devices are emerging making insulin treatment and glycemic control more reliable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Salt sensitivity of blood pressure is associated with an elevated risk of developing hypertension (HTN) and is an independent risk factor for cardiovascular disease. The prevalence of HTN increases after menopause. The aim of this study was to investigate prospectively whether the loss of ovarian hormones increases the occurrence of salt sensitivity among healthy premenopausal women. We enrolled 40 normotensive, nondiabetic women (age 47.2+/-3.5), undergoing hysterectomy-oophorectomy for nonneoplastic processes and not on hormone replacement, to determine the effect of changes in sodium intake on blood pressure the day before and subsequently 4 months after surgical menopause. Salt loading was achieved using a 2-L normal saline infusion and salt depletion produced by 40 mg of intravenous furosemide. A decrease >10 mm Hg in systolic blood pressure between salt loading and salt depletion was used to define salt sensitivity. Before and after menopause, salt-sensitive women exhibited higher waist/hip and waist/thigh ratios (P<0.01). Although all of the women remained normotensive, the prevalence of salt sensitivity was significantly higher after surgical menopause (21 women; 52.5%) than before (9 women; 22.5%; P=0.01), because 12 (38.7%) salt-resistant women developed salt sensitivity after menopause. In summary, we demonstrated that the prevalence of salt sensitivity doubled as early as 4 months after surgical menopause, without an associated increase in blood pressure. Epidemiological studies indicate that development of HTN may not occur until 5 to 10 years after menopause. The loss of ovarian hormones may unmask a population of women prone to salt sensitivity who, with aging, would be at higher risk for the subsequent development of HTN and cardiovascular disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study is part of an ongoing collaborative effort between the medical and the signal processing communities to promote research on applying standard Automatic Speech Recognition (ASR) techniques for the automatic diagnosis of patients with severe obstructive sleep apnoea (OSA). Early detection of severe apnoea cases is important so that patients can receive early treatment. Effective ASR-based detection could dramatically cut medical testing time. Working with a carefully designed speech database of healthy and apnoea subjects, we describe an acoustic search for distinctive apnoea voice characteristics. We also study abnormal nasalization in OSA patients by modelling vowels in nasal and nonnasal phonetic contexts using Gaussian Mixture Model (GMM) pattern recognition on speech spectra. Finally, we present experimental findings regarding the discriminative power of GMMs applied to severe apnoea detection. We have achieved an 81% correct classification rate, which is very promising and underpins the interest in this line of inquiry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: All kinds of blood manipulations aim to increase the total hemoglobin mass (tHb-mass). To establish tHb-mass as an effective screening parameter for detecting blood doping, the knowledge of its normal variation over time is necessary. The aim of the present study, therefore, was to determine the intraindividual variance of tHb-mass in elite athletes during a training year emphasizing off, training, and race seasons at sea level. METHODS: tHb-mass and hemoglobin concentration ([Hb]) were determined in 24 endurance athletes five times during a year and were compared with a control group (n = 6). An analysis of covariance was used to test the effects of training phases, age, gender, competition level, body mass, and training volume. Three error models, based on 1) a total percentage error of measurement, 2) the combination of a typical percentage error (TE) of analytical origin with an absolute SD of biological origin, and 3) between-subject and within-subject variance components as obtained by an analysis of variance, were tested. RESULTS: In addition to the expected influence of performance status, the main results were that the effects of training volume (P = 0.20) and training phases (P = 0.81) on tHb-mass were not significant. We found that within-subject variations mainly have an analytical origin (TE approximately 1.4%) and a very small SD (7.5 g) of biological origin. CONCLUSION: tHb-mass shows very low individual oscillations during a training year (<6%), and these oscillations are below the expected changes in tHb-mass due to Herythropoetin (EPO) application or blood infusion (approximately 10%). The high stability of tHb-mass over a period of 1 year suggests that it should be included in an athlete's biological passport and analyzed by recently developed probabilistic inference techniques that define subject-based reference ranges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To test the ability of a novel phase-shifting medium (PSM) to provide sustained distension of the uterine cavity and produce saline infusion sonography (SIS)-like images in a simplified contrast ultrasound procedure. DESIGN: Prospective pilot feasibility trial of a new diagnostic procedure, contrast ultrasound. SETTING: Clinical reproductive endocrine and infertility unit of regional teaching hospital. PATIENT(S): Twenty-six asymptomatic infertile women (group I) and 27 women presenting with dysfunctional uterine bleeding (DUB) who were scheduled for exploratory surgery (group II). INTERVENTION(S): All women who were temporarily on oral contraceptive first had a regular pelvic ultrasound followed by the intrauterine instillation of up to 3 mL PSM, using a regular insemination catheter, after which all instruments were removed and a regular ultrasound was performed again. RESULT(S): In all 53 women, intrauterine instillation of 1-3 mL PSM resulted in a 3-7 mm uterine distension, sufficient to produce SIS-like images of the uterine cavity that lasted 7-10 min. Contrast ultrasound revealed an endometrial polyp in 3 asymptomatic women of group I. In group II. 12 of 14 women (86%) whose vaginal ultrasound were positive or dubious had positive findings with contrast ultrasound; 9 of 12 patients whose vaginal ultrasounds were negative also had positive contrast ultrasound findings. All the positive and negative findings of contrast ultrasound made in group II were confirmed anatomically (sensitivity and specificity of 100%), whereas the correlation for standard vaginal ultrasound was markedly lower at 57.1% and 85.7%, respectively. Most patients (46 of 53) reported no discomfort during or after the procedure, and 7 women described the procedure as mildly uncomfortable. CONCLUSION(S): Contrast ultrasound, a novel simple diagnostic procedure conducted after intrauterine instillation of 1-3 mL PSM using a simple plastic catheter, delivered SIS-quality images in asymptomatic (group I) and symptomatic (group II) patients while retaining the simplicity of standard ultrasound. We therefore foresee broad application of contrast ultrasound for sensitive and specific assessment for uterine pathologies in the physician's office.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the current study was to compare two rapid methods, the BBL Mycobacteria Growth Indicator Tube (MGIT TM) and Biotec FASTPlaque TB TM (FPTB) assays, with the conventional Löwenstein-Jensen (LJ) media assay to diagnose mycobacterial infections from paucibacillary clinical specimens. For evaluation of the clinical utility of the BBL MGIT TM and FPTB assays, respiratory tract specimens (n = 208), with scanty bacilli or clinically evident, smear negative cases and non-respiratory tract specimens (n = 119) were analyzed and the performance of each assay was compared with LJ media. MGIT and FPTB demonstrated a greater sensitivity (95.92% and 87.68%), specificity (94.59% and 98.78%), positive predictive value (94.91% and 99.16%) and negative predictive value (96.56% and 90.92%), respectively, compared to LJ culture for both respiratory tract and non-respiratory tract specimens. However, the FPTB assay was unable to detect nontuberculous mycobacteria and few Mycobacterium tuberculosis complex cases from paucibacillary clinical specimens. It is likely that the analytical sensitivity of FPTB is moderately low and may not be useful for the direct detection of tuberculosis in paucibacillary specimens. The current study concluded that MGIT was a dependable, highly efficient system for recovery of M. tuberculosis complexes and nontuberculous mycobacteria from both respiratory and non-respiratory tract specimens in combination with LJ media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This population study, which evaluated two parasitological methods for the diagnosis of schistosomiasis mansoni, was performed in a low-transmission area in Pedra Preta, Montes Claros, Minas Gerais, Brazil. A total of 201 inhabitants of the rural area participated in this research. Four stool samples were obtained from all participants and analysed using the Kato-Katz method (18 slides) and a commercial test, the TF-Test®, which was performed quantitatively. The data were analysed to determine prevalence, the sensitivity of the diagnostic methods, the worm burden and the definition of the "gold standard", which was obtained by totalling the results of all samples examined using the Kato-Katz technique and the TF-Test®. The results showed that the prevalence obtained from the examination of one Kato-Katz slide (the methodology adopted by the Brazilian control programme) was 8% compared to 35.8% from the "gold standard", which was a 4.5-fold difference. This result indicates that the prevalence of schistosomiasis in so-called low-transmission areas is significantly underestimated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advances in clinical virology for detecting respiratory viruses have been focused on nucleic acids amplification techniques, which have converted in the reference method for the diagnosis of acute respiratory infections of viral aetiology. Improvements of current commercial molecular assays to reduce hands-on-time rely on two strategies, a stepwise automation (semi-automation) and the complete automation of the whole procedure. Contributions to the former strategy have been the use of automated nucleic acids extractors, multiplex PCR, real-time PCR and/or DNA arrays for detection of amplicons. Commercial fully-automated molecular systems are now available for the detection of respiratory viruses. Some of them could convert in point-of-care methods substituting antigen tests for detection of respiratory syncytial virus and influenza A and B viruses. This article describes laboratory methods for detection of respiratory viruses. A cost-effective and rational diagnostic algorithm is proposed, considering technical aspects of the available assays, infrastructure possibilities of each laboratory and clinic-epidemiologic factors of the infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nucleic acid amplification techniques are commonly used currently to diagnose viral diseases and manage patients with this kind of illnesses. These techniques have had a rapid but unconventional route of development during the last 30 years, with the discovery and introduction of several assays in clinical diagnosis. The increase in the number of commercially available methods has facilitated the use of this technology in the majority of laboratories worldwide. This technology has reduced the use of some other techniques such as viral culture based methods and serological assays in the clinical virology laboratory. Moreover, nucleic acid amplification techniques are now the methods of reference and also the most useful assays for the diagnosis in several diseases. The introduction of these techniques and their automation provides new opportunities for the clinical laboratory to affect patient care. The main objectives in performing nucleic acid tests in this field are to provide timely results useful for high-quality patient care at a reasonable cost, because rapid results are associated with improvements in patients care. The use of amplification techniques such as polymerase chain reaction, real-time polymerase chain reaction or nucleic acid sequence-based amplification for virus detection, genotyping and quantification have some advantages like high sensitivity and reproducibility, as well as a broad dynamic range. This review is an up-to-date of the main nucleic acid techniques and their clinical applications, and special challenges and opportunities that these techniques currently provide for the clinical virology laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A methodology of exploratory data analysis investigating the phenomenon of orographic precipitation enhancement is proposed. The precipitation observations obtained from three Swiss Doppler weather radars are analysed for the major precipitation event of August 2005 in the Alps. Image processing techniques are used to detect significant precipitation cells/pixels from radar images while filtering out spurious effects due to ground clutter. The contribution of topography to precipitation patterns is described by an extensive set of topographical descriptors computed from the digital elevation model at multiple spatial scales. Additionally, the motion vector field is derived from subsequent radar images and integrated into a set of topographic features to highlight the slopes exposed to main flows. Following the exploratory data analysis with a recent algorithm of spectral clustering, it is shown that orographic precipitation cells are generated under specific flow and topographic conditions. Repeatability of precipitation patterns in particular spatial locations is found to be linked to specific local terrain shapes, e.g. at the top of hills and on the upwind side of the mountains. This methodology and our empirical findings for the Alpine region provide a basis for building computational data-driven models of orographic enhancement and triggering of precipitation. Copyright (C) 2011 Royal Meteorological Society .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El programa experimental s’ha portat a terme dins el marc de les activitats del projecte TRUEFOOD, finançat per la UE per als anys 2007-2010. L’objectiu principal d’aquesta activitat ha estat l’avaluació dels continguts en àcid ascòrbic (vitamina C), polifenols totals, àcids fenòlics i flavonoides en mostres de tomàquet i enciam, produïts sota diferents condicions de camp (producció ecològica i convencional). Per aconseguir els resultats s’han utilitzat mètodes analítics basats en tècniques de cromatografia líquida d’alta eficàcia (HPLC) i d’ultra-alta eficàcia (UHPLC) acoblades a sistemes de detecció de diode array (DAD) i espectrometria de masses (MSn). Per a l’àcid ascòrbic, s’ha desenvolupat un mètode ràpid que ha permès la determinació d’aquest compost en diferents matrius vegetals amb el mínim pretractament de les mostres, utilitzant una fase estacionària HILIC (Fluorinated Stationary Phase). Els mètodes desenvolupats d’anàlisi de compostos fenòlics han permès realitzar les anàlisi de forma ràpida, a fi de processar el màxim nombre de mostres per a obtenir resultats representatius. S’ha realitzat una completa caracterització dels extractes de tomàquet i enciam, ampliant el coneixement descrit en la bibliografia sobre la seva composició fenòlica. En el cas de l’enciam, s’ha identificat quatre compostos fenòlics que mai abans han estat descrits i quantificats en aquesta hortalissa. La definició, amb precisió, dels continguts en vitamina C i compostos fenòlics en les mostres analitzades ha permès comparar els efectes de diferents tècniques de cultiu sobre les característiques nutricionals dels vegetals objecte de l’estudi. Els mètodes d’anàlisi desenvolupats i els resultats derivats del projecte seran publicats properament en revistes científiques de reconegut prestigi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A transportable Raman spectrometer was tested for the detection of illicit drugs seized during border controls. In a first step, the analysis methodology was optimized using reference substances such as diacetylmorphine (heroin), cocaine and amphetamine (as powder or liquid forms). Adequate focalisation distance and times of analysis, influence of daylight and artificial light sources, repeatability and limits of detection were studied. In a second step the applications and limitations of the technique to detect the illicit substances in different mixtures and containers was evaluated. Transportable Raman spectroscopy was found to be adequate for a rapid screen of liquids and powders for the detection and identification of controlled substances. Additionally, it had the advantage over other portable techniques, such as ion mobility spectrometry, of being non-destructive and capable of rapid analysis of large quantities of substances through containers such as plastic bags and glass bottles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Niterói, state of Rio de Janeiro, dengue virus type 4 (DENV-4) was isolated for the first time in March 2011. We analysed the laboratory findings of the first cases and evaluated the use of molecular techniques for the detection of DENV-4 in Aedes aegypti that were field-caught. Conventional reverse transcriptase-polymerase chain reaction (RT-PCR) and SimplexaTM Dengue real-time RT-PCR confirmed DENV-4 infection in all cases. Additionally, DENV-4 was confirmed in a female Ae. aegypti with 1.08 x 10³ copies/mL of virus, as determined by quantitative real-time RT-PCR. This is the first time the SimplexaTM Dengue real-time assay has been used for the classification of cases of infection and for entomological investigations. The use of these molecular techniques was shown to be important for the surveillance of dengue in humans and vectors.