755 resultados para Lenses


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To assess the relative clinical success of orthokeratology contact lenses (OK) and distance single-vision spectacles (SV) in children in terms of incidences of adverse events and discontinuations over a 2-year period. Methods. Sixty-one subjects 6 to 12 years of age with myopia of - 0.75 to - 4.00DS and astigmatism =1.00DC were prospectively allocated OK or SV correction. Subjects were followed at 6-month intervals and advised to report to the clinic immediately should adverse events occur. Adverse events were categorized into serious, significant, and non-significant. Discontinuation was defined as cessation of lens wear for the remainder of the study. Results. Thirty-one children were corrected with OK and 30 with SV. A higher incidence of adverse events was found with OK compared with SV (p < 0.001). Nine OK subjects experienced 16 adverse events (7 significant and 9 non-significant). No adverse events were found in the SV group. Most adverse events were found between 6 and 12 months of lens wear, with 11 solely attributable to OK wear. Significantly more discontinuations were found with SV in comparison with OK (p < 0.05). Conclusions. The relatively low incidence of adverse events and discontinuations with OK is conducive for the correction of myopia in children with OK contact lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To examine which baseline measurements constitute predictive factors for axial length growth over 2 years in children wearing orthokeratology contact lenses (OK) and single-vision spectacles (SV). METHODS: Sixty-one children were prospectively assigned to wear either OK (n = 31) or SV (n = 30) for 2 years. The primary outcome measure (dependent variable) was axial length change at 2 years relative to baseline. Other measurements (independent variables) were age, age of myopia onset, gender, myopia progression 2 years before baseline and baseline myopia, anterior chamber depth, corneal power and shape (p value), and iris and pupil diameters as well as parental refraction. The contribution of all independent variables to the 2-year change in axial length was assessed using univariate and multivariate regression analyses. RESULTS: After univariate analyses, smaller increases in axial length were found in the OK group compared to the SV group in children who were older, had earlier onset of myopia, were female, had lower rate of myopia progression before baseline, had less myopia at baseline, had longer anterior chamber depth, had greater corneal power, had more prolate corneal shape, had larger iris diameter, had larger pupil sizes, and had lower levels of parental myopia (all p < 0.05). In multivariate analyses, older age and greater corneal power were associated with smaller increases in axial length in the OK group (both p < 0.05), whereas in SV wearers, smaller iris diameter was associated with smaller increases in axial length (p = 0.021). CONCLUSIONS: Orthokeratology is a successful treatment option in controlling axial elongation compared to SV in children of older age, had earlier onset of myopia, were female, had lower rate of myopia progression before baseline, had lower myopia at baseline, had longer anterior chamber depth, had greater corneal power, had more prolate corneal shape, had larger iris and pupil diameters, and had lower levels of parental myopia. © American Academy of Optometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As technology and medical devices improve, there is much interest in when and how astigmatism should be corrected with refractive surgery. Astigmatism can be corrected by most forms of refractive surgery, such as using excimer lasers algorithms to ablate the cornea to compensate for the magnitude of refractive error in different meridians. Correction of astigmatism at the time of cataract surgery is well developed and can be achieved through incision placement, relaxing incisions and toric intraocular lens (IOL) implantation. This was less of an issue in the past when there was a lower expectation to be spectacle independent after cataract surgery, in which case the residual refractive error, including astigmatism, could be compensated for with spectacle lenses. The issue of whether presurgical astigmatism should be corrected can be considered separately depending on whether a patient has residual accommodation, and the type of refractive surgery under consideration. We have previously reported on the visual impact of full correction of astigmatism, rather than just correcting the mean spherical equivalent. Correction of astigmatism as low as 1.00 dioptres significantly improves objective and subjective measures of functional vision in prepresbyopes at distance and near.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultraviolet (UV) radiation potentially damages the skin, the immune system, and structures of the eye. A useful UV sun protection for the skin has been established. Since a remarkable body of evidence shows an association between UV radiation and damage to structures of the eye, eye protection is important, but a reliable and practical tool to assess and compare the UV-protective properties of lenses has been lacking. Among the general lay public, misconceptions on eye-sun protection have been identified. For example, sun protection is mainly ascribed to sunglasses, but less so to clear lenses. Skin malignancies in the periorbital region are frequent, but usual topical skin protection does not include the lids. Recent research utilized exact dosimetry and demonstrated relevant differences in UV burden to the eye and skin at a given ambient irradiation. Chronic UV effects on the cornea and lens are cumulative, so effective UV protection of the eyes is important for all age groups and should be used systematically. Protection of children's eyes is especially important, because UV transmittance is higher at a very young age, allowing higher levels of UV radiation to reach the crystalline lens and even the retina. Sunglasses as well as clear lenses (plano and prescription) effectively reduce transmittance of UV radiation. However, an important share of the UV burden to the eye is explained by back reflection of radiation from lenses to the eye. UV radiation incident from an angle of 135°-150° behind a lens wearer is reflected from the back side of lenses. The usual antireflective coatings considerably increase reflection of UV radiation. To provide reliable labeling of the protective potential of lenses, an eye-sun protection factor (E-SPF®) has been developed. It integrates UV transmission as well as UV reflectance of lenses. The E-SPF® compares well with established skin-sun protection factors and provides clear messages to eye health care providers and to lay consumers. © 2014 Behar-Cohen et al, This work is published by Dove Medical Press Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess refractive and biometric changes 1 week after discontinuation of lens wear in subjects who had been wearing orthokeratology (OK) contact lenses for 2 years. METHODS: Twenty-nine subjects aged 6 to 12 years and with myopia of -0.75 to -4.00 diopters (D) and astigmatism of ≤1.00 D participated in the study. Measurements of axial length and anterior chamber depth (Zeiss IOLMaster), corneal power and shape, and cycloplegic refraction were taken 1 week after discontinuation and compared with those at baseline and after 24 months of lens wear. RESULTS: A hyperopic shift was found at 24 months relative to baseline in spherical equivalent refractive error (+1.86±1.01 D), followed by a myopic shift at 1 week relative to 24 months (-1.93±0.92 D) (both P<0.001). Longer axial lengths were found at 24 months and 1 week in comparison to baseline (0.47±0.18 and 0.51±0.18 mm, respectively) (both P<0.001). The increase in axial length at 1 week relative to 24 months was statistically significant (0.04±0.06 mm; P=0.006). Anterior chamber depth did not change significantly over time (P=0.31). Significant differences were found between 24 months and 1 week relative to baseline and between 1-week and 24-month visits in mean corneal power (-1.68±0.80, -0.44±0.32, and 1.23±0.70 D, respectively) (all P≤0.001). Refractive change at 1 week in comparison to 24 months strongly correlated with changes in corneal power (r=-0.88; P<0.001) but not with axial length changes (r=-0.09; P=0.66). Corneal shape changed significantly between the baseline and 1-week visits (0.15±0.10 D; P<0.001). Corneal shape changed from a prolate to a more oblate corneal shape at the 24-month and 1-week visits in comparison to baseline (both P≤0.02) but did not change significantly between 24 months and 1 week (P=0.06). CONCLUSIONS: The effects of long-term OK on ocular biometry and refraction are still present after 1-week discontinuation of lens wear. Refractive change after discontinuation of long-term OK is primarily attributed to the recovery of corneal shape and not to an increase in the axial length.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. We investigated structural differences in the fatty acid profiles of lipids extracted from ex vivo contact lenses by using gas chromatography mass spectrometry (GCMS). Two lens materials (balafilcon A or lotrafilcon A) were worn on a daily or continuous wear schedule for 30 and 7 days. Methods. Lipids from subject-worn lenses were extracted using 1:1 chloroform: methanol and transmethylated using 5% sulfuric acid in methanol. Fatty acid methyl esters (FAMEs) were collected using hexane and water, and analyzed by GCMS (Varian 3800 GC, Saturn 2000 MS). Results. The gas chromatograms of lens extracts that were worn on a continuous wear schedule showed two predominant peaks, C16:0 and C18:0, both of which are saturated fatty acids. This was the case for balafilcon A and lotrafilcon A lenses. However, the gas chromatograms of lens extracts that were worn on a daily wear schedule showed saturated (C16:0, C18:0) and unsaturated (C16:1 and C18:1) fatty acids. Conclusions. Unsaturated fatty acids are degraded during sleep in contact lenses. Degradation occurred independently of lens material or subject-to-subject variability in lipid deposition. The consequences of lipid degradation are the production of oxidative products, which may be linked to contact lens discomfort. © 2014 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To assess the impact of light scatter, similar to that introduced by cataract on retinal vessel blood oxygen saturation measurements using poly-bead solutions of varying concentrations. Eight healthy, young, non-smoking individuals were enrolled for this study. All subjects underwent digital blood pressure measurements, assessment of non-contact intraocular pressure, pupil dilation and retinal vessel oximetry using dual wavelength photography (Oximetry Module, Imedos Systems, Germany). To simulate light scatter, cells comprising a plastic collar and two plano lenses were filled with solutions of differing concentrations (0.001, 0.002 and 0.004%) of polystyrene microspheres (Polysciences Inc., USA). The adopted light scatter model showed an artifactual increase in venous optical density ratio (p=0.036), with the 0.004% condition producing significantly higher venous optical density ratio values when compared to images without a cell in place. Spectrophotometric analysis, and thus retinal vessel oximetry of the retinal vessels, is altered by artificial light scatter. © 2013 Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To determine whether eyes implanted with the Lenstec KH-3500 "accommodative" intraocular lenses (IOLs) have improved subjective and objective focusing performance compared to a standard monofocal IOLs. Methods: 28 participants were implanted monocularly with a KH-3500 " accommodative" IOL and 20 controls with a Softec1 IOL. Outcome measures of refraction, visual acuity, subjective amplitude of accommodation, objective accommodative stimulus response curve, aberrometry, and Scheimpflug imaging were taken at ∼3 weeks and repeated after 6 months. Results: Best corrected acuity with the KH-3500 was 0.06 (SD 0.13) logMAR at distance and 0.58 (0.20) logMAR at near. Accommodation was 0.39 (0.53) D measured objectively and 3.1 (1.6) D subjectively. Higher order aberrations were 0.87 (0.85) μm and lower order were 0.24 (0.39) μm. Posterior subcapsular light scatter was 0.95% (1.37%) greater than IOL clarity. In comparison, all control group measures were similar except objective (0.17 (0.13) D; p = 0.032) and subjective (2.0 (0.9) D; p = 0.009) amplitude of accommodation. Six months following surgery, posterior subcapsular scatter had increased (p<0.01) in the KH-3500 implanted subjects and near word acuity had decreased (p<0.05). Conclusions: The objective accommodating effects of the KH-3500 IOL appear to be limited, although the subjective and objective accommodative range is significantly increased compared to control subjects implanted with conventional IOLs. However, this "accommodative" ability of the lens appears to have decreased by 6 months post-surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The central goal of this research is to explore the approach of the Islamic banking industry in defining and implementing religious compliance at regulatory, institutional, and individual level within the Islamic Banking and Finance (IBF) industry. It also examines the discrepancies, ambiguities and paradoxes that are exhibited in the individual and institutional behaviour in relation to the infusion and enactment of religious exigencies into compliance processes in IBF. Through the combined lenses of institutional work and a sensemaking perspective, this research portrays the practice of infusion of Islamic law in Islamic banks as being ambiguous and drifting down to the institutional and actor levels. In instances of both well-codified and non-codified regulatory frameworks for Shariah compliance, institutional rules ambiguity, rules interpretation and enactment ambiguities were found to be prevalent. The individual IBF professionals performed retrospective and prospective actions to adjust the role and rules boundaries both in the case of a Muslim and a non-Muslim country. The sensitizing concept of religious compliance is the primary theoretical contribution of this research and provides a tool to understand the nature of what constitutes Shariah compliance and the dynamics of its implementation. It helps to explain the empirical consequences of the lack of a clear definition of Shariah compliance in the regulatory frameworks and standards available for the industry. It also addresses the calls to have a clear reference on what constitute Shariah compliance in IBF as proposed in previous studies (Hayat, Butter, & Kock, 2013; Maurer, 2003, 2012; Pitluck, 2012). The methodological and theoretical perspective of this research are unique in the use of multi-level analysis and approaches that blend micro and macro perspectives of the research field, to illuminate and provide a more complete picture of religious compliance infusion and enactment in IBF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To report differences in the incidence of adverse events and discontinuations found in a group of neophyte contact wearers using two different silicone hydrogel contact lenses on a daily- and continuous-wear basis during an 18-month period. METHODS. Sixty-one subjects were initially examined, and 53 were eligible to participate in the study. Eligible subjects were randomly assigned to wear one of two silicone hydrogel materials: lotrafilcon A or balafilcon A lenses on a daily- or continuous-wear basis. After an initial screening, subjects were monitored weekly for the first month and then after 3, 6, 12, and 18 months. The incidence of adverse events, including corneal infiltrative events, superior epithelial arcuate lesions, and contact lens-induced papillary conjunctivitis, and discontinuations in each of the four contact lens groups were recorded. RESULTS. Twenty-two adverse events were found. A higher incidence of adverse events was found in subjects wearing lotrafilcon A lenses than in those wearing balafilcon A lenses (χ = 4.40, P=0.04). There were fewer adverse events in subjects wearing lenses on a daily-wear basis than in those wearing lenses on a continuous-wear basis (χ = 5.98, P=0.01). Eight subjects discontinued from the study as a result of recurrent corneal infiltrative events (one), vision problems (two), excessive ocular discomfort (one), relocation (one), noncompliance with the study protocol (one), and being lost to follow-up (two). No significant differences were found in the number of discontinuations between the two lens types (χ = 0.66, P=0.42) and wearing regimens (χ = 0.08, P=0.78). CONCLUSIONS. Lotrafilcon A lenses were associated with a higher incidence of adverse events than balafilcon A lenses were, and this difference is attributed to the difference in the incidence of corneal infiltrative events. Subjects wearing lenses on a daily-wear basis had fewer adverse events than did subjects wearing lenses on a continuous-wear basis. Both lens types and wearing regimens showed a similar incidence of discontinuations. © 2007 Lippincott Williams & Wilkins, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The induced lenses in the Yb:YAG rods and disks end-pumped by a Gaussian beam were analyzed both analytically and numerically. The thermally assisted mechanisms of the lens formation were considered to include: the conventional volume thermal index changes ("dn/dT"), the bulging of end faces, the photoelastic effect, and the bending (for a disk). The heat conduction equations (with an axial heat flux for a disk and a radial heat flux for a rod), and quasi-static thermoelastic equations (in the plane-stress approximation with free boundary conditions) were solved to find the thermal lens power. The population rate equation with saturation (by amplified spontaneous emission or an external wave) was examined to find the electronic lens power in the active elements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Welcome to the latest issue of Contact Lens and Anterior Eye. In this issue, Kuldeep Razaida provides a fascinating look at fitting prosthetic lenses to patients in India. I had the good fortune of visiting his clinic in August 2006 at the LV Prasad Eye Institute in Hyderabad, India and was humbled by the vast expertise within the one building. The institute started in 1987 and is the brainchild of the infamous Professor Rao. I think there are few such places in the world where the clinicians work so passionately in treating such interesting patients (for details regarding the LV Prasad Eye Institute see www.lvpei.org). I was in Hyderabad courtesy of IACLE (see issue 29:5 for an editorial by Judith Morris and Sonja Cronje about IACLE) and was able to share ideas with contact lens educators from across the world (for more information on IACLE see www.iacle.org). The issue contains some regular contact lens type papers too; with our aging population readers will be particularly interested in a paper by Mike Freeman and Neil Charman looking at modified monovision with diffractive bifocal lenses. There is an article looking at visual problems with video display terminal use and a study looking at the effects of surface treatment of silicone hydrogel contact lenses. There is an interesting piece from Dr Aisling Mann of Aston University looking at tear protein analysis; this article contains one CET point too for readers who complete the attached multiple choice questions before the relevant deadline. Also, congratulations to the BCLA members who successfully undertook the Fellowship of the BCLA at this year's BCLA conference in Manchester. If you are interested in undertaking the Fellowship please look at the details on the BCLA web page (http://www.bcla.org.uk/fellowship.asp). Amongst the case reports in this issue of CLAE you will notice one from Andrew Elder-Smith, this particular case report was presented as part of his successful Fellowship submission in 2006 and was thought to be of particular good quality by the examiners who asked Andrew to kindly submit it for publication to Contact Lens and Anterior Eye as an example for potential candidates. Finally, it is my sad duty to report the death of Howard Gee earlier this year, a past council member of the BCLA. Our thoughts and prayers are with his family and friends.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Defocus curves are used to evaluate the subjective range of clear vision of presbyopic corrections such as in eyes implanted with accommodating intraocular lenses (IOLs). This study determines whether letter sequences and/or lens presentation order ought to be randomised when measuring defocus curves. Methods: Defocus curves (range +2.00DS to -2.00DS) were measured on 18 pre-presbyopic subjects (mean age 24.1 ± 4.2 years) for six combinations of sequential or randomised positive or negative lens progression and non-randomised or randomised letter sequences. The letters were presented on a computerised logMAR chart at 6 m. Results: Overall there was a statistically significant difference between the six combinations (ANOVA, p < 0.05) attributable to the combination of non-randomised letters with non-randomised lens progression from negative to positive defocus (p < 0.01). There was no statistically significant difference in defocus curve measurements if both letters and lens order were randomised compared to if only one of these variables was randomised (p > 0.05). Non-randomised letters, with a sequential lens progression from negative to positive, was significantly different to all other combinations when compared individually (Student's T-test, p < 0.003 on all comparisons), and was confirmed as the sole source of the overall significant difference. There was no statistically significant difference if both lens presentation order and letter sequences were randomised compared to if only one or the other of these variables was randomised. Conclusion: Non-randomised letters and non-randomised lens progression on their own did not affect the subjective amplitude of accommodation as measured by defocus curves, although their combination should be avoided. © 2007 British Contact Lens Association.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. The purpose of this study was to evaluate the longitudinal changes in ocular physiology, tear film characteristics, and symptomatology experienced by neophyte silicone hydrogel (SiH) contact lens wearers in a daily-wear compared with a continuous-wear modality and with the different commercially available lenses over an 18-month period. Methods. Forty-five neophyte subjects were enrolled in the study and randomly assigned to wear one of two SiH materials: lotrafilcon A or balafilcon A lenses on either a daily- (LDW; BDW) or continuous-wear (LCW; BCW) basis. Additionally, a group of noncontact lens-wearing subjects (control group) was also recruited and followed over the same study period. Objective and subjective grading of ocular physiology were carried out together with tear meniscus height (TMH) and noninvasive tear breakup time (NITBUT). Subjects also subjectively rated symptoms and judgments with lens wear. After initial screening, subsequent measurements were taken after 1, 3, 6, 12, and 18 months. Results. Subjective and objective grading of ocular physiology revealed a small increase in bulbar, limbal, and palpebral hyperemia as well as corneal staining over time with both lens materials and regimes of wear (p < 0.05). No significant changes in NITBUT or TMH were found (p > 0.05). Subjective symptoms and judgment were not material- or modality-specific. Conclusions. Daily and continuous wear of SiH contact lenses induced small but statistically significant changes in ocular physiology and symptomatology. Clinical measures of tear film characteristics were unaffected by lens wear. Both materials and regimes of wear showed similar clinical performance. Long-term SiH contact lens wear is shown to be a successful option for patients. Copyright © 2006 American Academy of Optometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The American Academy of Optometry (AAO) had their annual meeting in San Diego in December 2005 and the BCLA and CLAE were well represented there. The BCLA does have a reasonable number of non-UK based members and hopefully in the future will attract more. This will certainly be beneficial to the society as a whole and may draw more delegates to the BCLA annual conference. To increase awareness of the BCLA at the AAO a special evening seminar was arranged where BCLA president Dr. James Wolffsohn gave his presidential address. Dr. Wolffsohn has given the presidential address in the UK, Ireland, Hong Kong and Japan – making it the most travelled presidential address for the BCLA to date. Aside from the BCLA activity at the AAO there were numerous lectures of interest to all, truly a “something for everyone” meeting. All the sessions were multi-track (often up to 10 things occurring at the same time) and the biggest dilemma was often deciding what to attend and more importantly what you will miss! Nearly 200 new AAO Fellows were inducted at the Gala Dinner from many countries including 3 new fellows from the UK (this year they all just happened to be from Aston University!). It is certainly one of the highlights of the AAO to see fellows from different schools of training from around the world fulfilling the same criteria and being duly rewarded for their commitment to the profession. BCLA members will be aware that 2006 sees the introduction of the new fellowship scheme of the BCLA and by the time you read this the first set of fellowship examinations will have taken place. For more details of the FBCLA scheme see the BCLA web site http://www.bcla.org.uk. Since many of CLAE's editorial panel were at the AAO an informal meeting and dinner was arranged for them where ideas were exchanged about the future of the journal. It is envisaged that the panel will meet twice a year – the next meeting will be at the BCLA conference. The biggest excitement by far was the fact that CLAE is now Medline/PubMed indexed. You may ask why is this significant to CLAE? PubMed is the free web-based service from the US National Library of Medicine. It holds over 15 million biomedical citations and abstracts from the Medline database. Medline is the largest component of PubMed and covers over 4800 journals published in more than 70 countries. The impact of this is that CLAE is starting to attract more submissions as researchers and authors are not worried that their work will not be hidden from other colleagues in the field but rather the work is available to view on the World Wide Web. CLAE is one of a very small number of contact lens journals that is indexed this way. Amongst the other CL journals listed you will note that the International Contact Lens Clinic has now merged with CLAE and the journal CLAO has been renamed Eye and Contact Lenses – making the list of indexed CL journals even smaller than it appears. The on-line submission and reviewing system introduced in 2005 has also made it easier for authors to submit their work and easier for reviewers to check the content. This ease of use has lead to quicker times from submission to publication. Looking back at the articles published in CLAE in 2005 reveals some interesting facts. The majority of the material still tends to be from UK groups related to the field of Optometry, although we hope that in the future we will attract more work from non-UK groups and also from non-Optometric areas such as refractive surgery or anterior eye pathology. Interestingly in 2005 the most downloaded article from CLAE was “Wavefront technology: Past, present and future” by Professor W. Neil Charman, who was also the recipient of the Charles F. Prentice award at the AAO – one of the highest awards honours that the AAO can bestow. Professor Charman was also the keynote speaker at the BCLA's first Pioneer's Day meeting in 2004. In 2006, readers of CLAE will notice more changes, firstly we are moving to 5 issues per year. It is hoped that in the future, depending on increased submissions, a move to 6 issues may be feasible. Secondly, CLAE will aim to have one article per issue that carries CL CET points. You will see in this issue there is an article from Professor Mark Wilcox (who was a keynote speaker at the BCLA conference in 2005). In future articles that carry CET points will be either reviews from BCLA conference keynote speakers, members of the editorial panel or material from other invited persons that will be of interest to the readership of CLAE. Finally, in 2006, you will notice a change to the Editorial Panel, some of the distinguished panel felt that it was good time to step down and new members have been invited to join the remaining panel. The panel represent some of the most eminent names in the fields of contact lenses and/or anterior eye and have varying backgrounds and interests from many of the prominent institutions around the world. One of the tasks that the Editorial Panel undertake is to seek out possible submissions to the journal, either from conferences they attend (posters and papers that they will see and hear) and from their own research teams. However, on behalf of CLAE I would like to extend that invitation to seek original articles to all readers – if you hear a talk and think it could make a suitable publication to CLAE please ask the presenters to submit the work via the on-line submission system. If you found the work interesting then the chances are so will others. CLAE invites submissions that are original research, full length articles, short case reports, full review articles, technical reports and letters to the editor. The on-line submission web page is http://www.ees.elsevier.com/clae/.