949 resultados para LASER LINEWIDTH MEASUREMENT


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present an application of cavity-enhanced absorption spectroscopy with an off-axis alignment of the cavity formed by two spherical mirrors and with time integration of the cavity-output intensity for detection of nitrogen dioxide (NO2) and iodine monoxide (IO) radicals using a violet laser diode at lambda = 404.278 nm. A noise-equivalent (1sigma = root-mean-square variation of the signal) fractional absorption for one optical pass of 4.5x10(-8) was demonstrated with a mirror reflectivity of similar to0.99925, a cavity length of 0.22 m and a lock-in-amplifier time constant of 3 s. Noise-equivalent detection sensitivities towards nitrogen dioxide of 1.8x10(10) molecule cm(-3) and towards the IO radical of 3.3x10(9) molecule cm(-3) were achieved in flow tubes with an inner diameter of 4 cm for a lock-in-amplifier time constant of 3 s. Alkyl peroxy radicals were detected using chemical titration with excess nitric oxide (RO2 + NO --> RO + NO2). Measurement of oxygen-atom concentrations was accomplished by determining the depletion of NO2 in the reaction NO2 + O --> NO + O-2. Noise-equivalent concentrations of alkyl peroxy radicals and oxygen atoms were 3x10(10) molecule cm(-3) in the discharge-flow-tube experiments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ruminant husbandry is a major source of anthropogenic greenhouse gases (GHG). Filling knowledge gaps and providing expert recommendation are important for defining future research priorities, improving methodologies and establishing science-based GHG mitigation solutions to government and non-governmental organisations, advisory/extension networks, and the ruminant livestock sector. The objectives of this review is to summarize published literature to provide a detailed assessment of the methodologies currently in use for measuring enteric methane (CH4) emission from individual animals under specific conditions, and give recommendations regarding their application. The methods described include respiration chambers and enclosures, sulphur hexafluoride tracer (SF6) technique, and techniques based on short-term measurements of gas concentrations in samples of exhaled air. This includes automated head chambers (e.g. the GreenFeed system), the use of carbon dioxide (CO2) as a marker, and (handheld) laser CH4 detection. Each of the techniques are compared and assessed on their capability and limitations, followed by methodology recommendations. It is concluded that there is no ‘one size fits all’ method for measuring CH4 emission by individual animals. Ultimately, the decision as to which method to use should be based on the experimental objectives and resources available. However, the need for high throughput methodology e.g. for screening large numbers of animals for genomic studies, does not justify the use of methods that are inaccurate. All CH4 measurement techniques are subject to experimental variation and random errors. Many sources of variation must be considered when measuring CH4 concentration in exhaled air samples without a quantitative or at least regular collection rate, or use of a marker to indicate (or adjust) for the proportion of exhaled CH4 sampled. Consideration of the number and timing of measurements relative to diurnal patterns of CH4 emission and respiratory exchange are important, as well as consideration of feeding patterns and associated patterns of rumen fermentation rate and other aspects of animal behaviour. Regardless of the method chosen, appropriate calibrations and recovery tests are required for both method establishment and routine operation. Successful and correct use of methods requires careful attention to detail, rigour, and routine self-assessment of the quality of the data they provide.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our aim was to investigate the immediate effects of bilateral, 830 nm, low-level laser therapy (LLLT) on high-intensity exercise and biochemical markers of skeletal muscle recovery, in a randomised, double-blind, placebo-controlled, crossover trial set in a sports physiotherapy clinic. Twenty male athletes (nine professional volleyball players and eleven adolescent soccer players) participated. Active LLLT (830 nm wavelength, 100 mW, spot size 0.0028 cm(2), 3-4 J per point) or an identical placebo LLLT was delivered to five points in the rectus femoris muscle (bilaterally). The main outcome measures were the work performed in the Wingate test: 30 s of maximum cycling with a load of 7.5% of body weight, and the measurement of blood lactate (BL) and creatine kinase (CK) levels before and after exercise. There was no significant difference in the work performed during the Wingate test (P > 0.05) between subjects given active LLLT and those given placebo LLLT. For volleyball athletes, the change in CK levels from before to after the exercise test was significantly lower (P = 0.0133) for those given active LLLT (2.52 U l(-1) +/- 7.04 U l(-1)) than for those given placebo LLLT (28.49 U l(-1) +/- 22.62 U l(-1)). For the soccer athletes, the change in blood lactate levels from before exercise to 15 min after exercise was significantly lower (P < 0.01) in the group subjected to active LLLT (8.55 mmol l(-1) +/- 2.14 mmol l(-1)) than in the group subjected to placebo LLLT (10.52 mmol l(-1) +/- 1.82 mmol l(-1)). LLLT irradiation before the Wingate test seemed to inhibit an expected post-exercise increase in CK level and to accelerate post-exercise lactate removal without affecting test performance. These findings suggest that LLLT may be of benefit in accelerating post-exercise recovery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the design and development of a low cost three-dimensional laser imaging system for scanning suitable surfaces. A generic, low cost, off-the-shelf laser range finder is used to obtain the primary one dimensional distance measurement. The range finder’s laser beam is reflected by a twin-axis mirror assembly driven by stepper motors providing the system with two angular degrees of freedom, allowing 3-D measurements to be determined. A camera and image processing techniques are used to determine the measured 1-D range value from the generic range-finding device. A computer program then uses the obtained data to create a 3-D point cloud. An algorithm is then used to construct a 3-D wire frame mesh representing the scanned surface. The system has an angular resolution of 1.8° and the results obtained demonstrate the system to have an accuracy of approximately ± 2cm at a scanning distance of 1.0m.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research deals with processes leading to local strengthening effects in hot-rolled dual-phase (DP) steels. For this purpose, a method was investigated to achieve local strengthening, namely, local laser heat treatment (LHT). DP sheet steels were globally and homogenously deformed with different degrees of prestrains by cold rolling and subsequently locally heat treated by laser. Following this treatment with selected parameters, the microstructure of the surface and cross section of the heat-treated area as well as the mechanical properties were evaluated by light optical microscopy (LOM), scanning electron microscopy (SEM), as well as transmission electron microscopy (TEM), hardness measurement, and tensile testing. It can be stated that with partial heat treatment, local high strengthening can be produced. At lower heat treating temperatures, this effect could be attributed to bake hardening (BH). Increasing the prestrain as well as temperature results in improving the local properties. With increased heat treating temperature, the initial microstructure near the surface is affected. Partial strengthening of DP steels by laser can open up new fields of application for locally using the strengthening effect to only influence relevant areas of interest, thus providing the potential for saving energy and designed the component's behavior.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The stretch zone width (SZW) data for 15-5PH steel CTOD specimens fractured at -150 degrees C to + 23 degrees C temperature were measured based on focused images and 3D maps obtained by extended depth-of-field reconstruction from light microscopy (LM) image stacks. This LM-based method, with a larger lateral resolution, seems to be as effective for quantitative analysis of SZW as scanning electron microscopy (SEM) or confocal scanning laser microscopy (CSLM), permitting to clearly identify stretch zone boundaries. Despite the worst sharpness of focused images, a robust linear correlation was established to fracture toughness (KC) and SZW data for the 15-5PH steel tested specimens, measured at their center region. The method is an alternative to evaluate the boundaries of stretched zones, at a lower cost of implementation and training, since topographic data from elevation maps can be associated with reconstructed image, which summarizes the original contrast and brightness information. Finally, the extended depth-of-field method is presented here as a valuable tool for failure analysis, as a cheaper alternative to investigate rough surfaces or fracture, compared to scanning electron or confocal light microscopes. Microsc. Res. Tech. 75:11551158, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to evaluate laser fluorescence (LF) for monitoring the initial stage of subsurface de- and remineralization (<150 mu m depth). Ninety-six sound blocks of bovine enamel, selected according to surface hardness (SH) and LF were used in two experimental studies, in vitro and in situ. In vitro, blocks were exposed to a demineralizing solution, then remineralized by pH cycling for 6 days. In situ, 10 volunteers wore acrylic palatal appliances, each containing 4 dental enamel blocks that were demineralized for 14 days by exposure to 20% sucrose solution. Following this treatment, blocks were submitted to remineralization for 1 week with fluoride dentifrice (1,100 mu g F/g). In both experiments, SH and LH were measured after demineralization and after remineralization. Further, enamel blocks were selected after the demineralization/remineralization steps for measurement of cross-sectional hardness and integrated loss of subsurface hardness (Delta KHN). SH and Delta KHN showed significant differences among the phases in each study. LF values for sound, demineralized and remineralized enamel were: 5.2 +/- 1.1, 8.1 +/- 1.2 and 5.6 +/- 0.8, respectively, in the in vitro study, and 5.3 +/- 0.3, 16.5 +/- 4.7 and 6.5 +/- 2.5, respectively, in the in situ study, values for demineralized enamel being significantly higher than for sound and remineralized enamel in both studies. However, LF was correlated with Delta KHN only in situ. LF was capable of monitoring de- and remineralization in early lesions in situ, when bacteria are presumably present in the caries lesion body, but is not correlated with mineral changes in bacteria-free systems. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To investigate the healing of bone defects in male rats treated with salmon calcitonin, low-level laser therapy (LLLT), or both. Background: Healing of bone defects still represents a challenge to health professionals in several areas. In this article, the effect of calcitonin in combination with LLLT on bone repair was studied. Densitometry was used as a valuable tool for the measurement of bone regeneration. Methods: Sixty male Wistar rats underwent bilateral castration surgery before the creation of a surgical bone defect. The animals were randomly divided into four groups: control, treated with calcitonin (Ca), treated with LLLT (La), and treated with calcitonin and LLLT (CaLa). Groups Ca and CaLa received 2 IU/kg of synthetic salmon calcitonin intra-muscularly three times a week. Groups La and CaLa received laser therapy using a gallium-aluminum-arsenide laser (10mW, 20 J/cm(2), wavelength 830 nm). Control animals were submitted to sham irradiation. The animals were sacrificed 7, 14, and 21 days after surgery, and bone defects were analyzed using densitometry. Results: The CaLa group had a higher degree of bone regeneration 14 and 21 days after surgery. Conclusions: The La and CaLa had significantly higher bone mineral density than the control and Ca groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method for improving the accuracy of surface shape measurement by multiwavelength holography is presented. In our holographic setup, a Bi12TiO20 photorefractive crystal was the holographic recording medium, and a multimode diode laser emitting in the red region was the light source in a two-wave mixing scheme. on employing such lasers the resulting holographic image appears covered with interference fringes corresponding to the object relief, and the interferogram spatial frequency is proportional to the diode laser's free spectral range (FSR). Our method consists in increasing the effective free spectral range of the laser by positioning a Fabry-Perot etalon at the laser output for mode selection. As larger effective values of the laser FSR were achieved, higher-spatial-frequency interferograms were obtained and therefore more sensitive and accurate measurements were performed. The quantitative evaluation of the interferograms was made through the phase-stepping technique, and the phase map unwrapping was carried out through the cellular-automata method. For a given surface, shape measurements with different interferogram spatial frequencies were performed and compared with respect to measurement noise and visual inspection. (c) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Profilometry by electronic speckle pattern interferometry with multimode diode lasers is both theoretically and experimentally studied. The multiwavelength character of the laser emission provides speckled images covered with interference fringes corresponding to the surface relief in single-exposure processes. For fringe pattern evaluation, variations of the phase-stepping technique are investigated for phase mapping as a function of the number of laser modes. Expressions for two, three, and four modes in four and eight stepping are presented, and the performances of those techniques are compared in the experiments through the surface shaping of a flat bar. The surface analysis of a peach points out the possibility of applying the technique in the quality control of food production and agricultural research. (c) 2007 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To establish safety parameters, we in vitro studied the increase in intrapulpal temperature caused by the use of a cw CO2 laser. A thermistor was implanted in the inner part of the pulpal chamber of 25 human lower third molars to measure the intrapulpal temperature produced by laser powers between 2-10 W and exposure times of 0.5-25.0 s. The Pearson linear correlation factor applied to the measured values showed there is a direct relationship between the independent variable and the applied power. A variance analysis produced the linear regression equation: T=1.10+(0.127)E where T is the temperature and E the energy. The results showed that, with a power of 4 W and maximum exposure time of 2.5 s (10 J) and a power density of 12738.85 W cm-2, there will be no damaging reactions affecting the pulpal tissues.