806 resultados para Intraocular Lens Implantation
Resumo:
The clinical value of early exercise stress testing (EST) after coronary stenting to predict long-term clinical outcomes is unknown. Of 1,000 unselected patients who underwent coronary stenting, 446 random patients underwent early EST the day after intervention. Clinical long-term outcomes (41 +/- 20 months) were correlated with normal (n = 314 [70%]) or positive (n = 102 [23%]) EST results. Patients with inconclusive test results (n = 30 [7%]) were excluded from the analysis. Overall mortality was significantly higher in patients with positive EST results (9.3% vs 3.9%, p = 0.04). Major adverse cardiac events and cardiac mortality also tended to be higher in patients with positive stress test results (45.4% vs 35.4%, p = 0.08, and 4.1% vs 1.1%, p = 0.05, respectively). Patients with the combination of positive stress test results and incomplete revascularization appeared to be the group at highest risk for major adverse cardiac events (47.1% vs 33.3% for patients with normal stress test results and complete revascularization, p = NS). Negative stress test results reduced (odds ratio 0.329, 95% confidence interval 0.120 to 0.905, p = 0.031) and a lower ejection fraction increased (odds ratio 0.942, 95% confidence interval 0.897 to 0.989, p = 0.017) the risk for death. In conclusion, an early stress test after coronary stenting provides important prognostic information. Positive stress test results, especially in combination with incomplete revascularization, are associated with higher mortality, a trend toward more repeat revascularization procedures, and higher risk for major adverse cardiac events.
Resumo:
Rotational atherectomy has been regaining interest over the last couple of years after it almost has disappeared from most interventional catheterization laboratories for several years due to failure to prove its original concept of improving long term results of percutaneous coronary interventions (PCI) as was repeatedly shown in studies in the 1990s. Its revival coupled the introduction of drug-eluting stents (DES); these devices have led to treating much more complex lesions and high-risk patients by PCI. However, real-world experience suggested that off-label use of DES is associated with a higher rate of early and late stent thrombosis. Therefore, more attention is now being paid to the initial implantation technique of DES including aggressive lesion preparation to facilitate stent delivery and expansion. The limited studies with rot-ablation and DES showed promising results with no long term safety concerns. In these studies, a subtle observation was made suggesting that rot-ablation prior to DES implantation in such lesions may have an add-on effect on long term outcome compared to DES alone. An ongoing multicenter study is investigating such effect among complex calcified coronary lesions. Even if this additive benefit does not prove true, rot-ablation remains an efficient tool for preparing certain lesions to facilitate effective and safe DES implantation. Therefore, interventional training programs should focus on this difficult technique to bridge the gap of experience which resulted from neglecting it for several years. In this regard, dedicated courses at experienced sites as well as medical simulation may be appropriate.
Resumo:
AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.
Resumo:
PURPOSE: We report the clinical, morphological, and ultrastructural findings of 13 consecutively explanted opacified Hydroview(R) (hydrogel) intraocular lenses (IOLs). Our purpose was to provide a comprehensive account on the possible factors involved in late postoperative opacification of these IOLs. PATIENTS AND METHODS: Thirteen consecutive opacified hydrogel IOLs (Hydroview H 60 M, Bausch ; Lomb) were explanted due to the significant visual impairment they caused. The IOLs underwent macroscopical examination, transmission electron microscopy (TEM), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and electrophoresis for protein detection. Three unused control Hydroview IOLs served for comparison. RESULTS: Macroscopical examination showed a diffuse or localized grey-whitish opacification within the IOL optic. TEM confirmed the presence of lesions inside the optic in all the explanted IOLs and revealed 3 patterns of deep deposits: a) diffuse, thick, granular, electron-dense ones; b) small, thin, lattice-like ones, with prominent electron-lucent areas; and c) elongated electron-dense formations surrounded by electron-lucent halos. SEM showed surface deposits on four IOLs. EDS revealed oxygen and carbon in all IOLs and documented calcium, phosphorus, silicon and/or iron in the deposits. Two of the patients with iron in their IOLs had eye surgery prior to their phacoemulsification. Iron correlated well with the second TEM pattern of deep lesions, whereas calcium with the third TEM pattern. No protein bands were detected on electrophoresis. Control lenses did not show any ultrastructural or chemical abnormality. CONCLUSIONS: The present study supports the presence of chemical alterations inside the polymer of the optic in late postoperative opacification of Hydroview IOLs. This opacification does not follow a unique pathway but may present under different ultrastructular patterns depending on the responsible factors. Mechanical stress during surgery may initiate a sequence of events where ions such as calcium, phosphorus, silicon, and/or iron, participate in a biochemical cascade that leads to gradual alteration of the polymer network. Intraocular inflammation due to previous operation may be a factor inducing opacification through increase of iron-binding capacity in the aqueous humour. Calcification accounts only partially for the opacification noted in this type of IOL.
Resumo:
The exponential increase in cardioverter-defibrillator implantations has resulted in a need for safe implantations that do not require long waiting periods. We report intraoperative and follow-up results in 48 patients with ventricular tachyarrhythmias who underwent cardioverter-defibrillator implantation in the catheterization laboratory. Twenty-six (54%) patients had their first cardioverter-defibrillator implant (group 1), and 22 (46%) patients underwent pulse-generator replacement (group 2). In all patients, cardioverter-defibrillator implant or pulse-generator replacement was performed with the patient under general anesthesia. In 25 (96%) of 26 patients in group 1, cardioverter-defibrillator implantation was possible with a mean defibrillation threshold of 13 +/- 8 J. One patient had a defibrillation threshold of > 25 J, and therefore cardioverter-defibrillator implant was not achieved. This patient underwent epicardial device implantation 1 day later. Another patient in group 1 had vessel rupture (vena subclavia) intraoperatively. During a mean follow-up of 2 +/- 1 months, two patients died from congestive heart failure 2 and 4 months after device implantation. An infection occurred in one patient in group 2, 3 months after generator replacement. In conclusion, these data show that in the majority of patients cardioverter-defibrillator implantation in the catheterization laboratory is safe and has a low complication rate and therefore can generally be recommended.
Resumo:
OBJECTIVES: This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND: The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS: The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronary artery disease who underwent AMS implantation. Angiography and intravascular ultrasound (IVUS) were conducted immediately after AMS deployment and at 4 months. Eight patients who did not require repeat revascularization at 4 months underwent late angiographic and IVUS follow-up from 12 to 28 months. RESULTS: The AMS was well-expanded upon deployment without immediate recoil. The major contributors for restenosis as detected by IVUS at 4 months were: decrease of external elastic membrane volume (42%), extra-stent neointima (13%), and intra-stent neointima (45%). From 4 months to late follow-up, paired IVUS analysis demonstrated complete stent degradation with durability of the 4-month IVUS indexes. The neointima was reduced by 3.6 +/- 5.2 mm(3), with an increase in the stent cross sectional area of 0.5 +/- 1.0 mm(2) (p = NS). The median in-stent minimal lumen diameter was increased from 1.87 to 2.17 mm at long-term follow-up. The median angiographic late loss was reduced from 0.62 to 0.40 mm by quantitative coronary angiography from 4 months to late follow-up. CONCLUSIONS: Intravascular ultrasound imaging supports the safety profile of AMS with degradation at 4 months and maintains durability of the results without any early or late adverse findings. Slower degradation is warranted to provide sufficient radial force to improve long-term patency rates of the AMS.
Resumo:
BACKGROUND: The association between aortic valve disease and coronary atherosclerosis is common. In the recent era of percutaneous aortic valve replacement (PAVR), there is little experience with coronary artery intervention after valve implantation. CASE REPORT: To our knowledge, this is the first case of successful percutaneous coronary intervention after implantation of a CoreValve percutaneous aortic valve. We report a case of a 79-year-old female patient who underwent successful coronary artery intervention few months after a CoreValve's percutaneous implantation for severe aortic valve stenosis. Verifying the position of the used wires (crossing from inside the self expanding frame) is of utmost importance before proceeding to coronary intervention. In this case, crossing the aortic valve, coronary angiography, and multivessel stenting were successfully performed. CONCLUSION: Percutaneous coronary intervention in patients with previous CoreValve is feasible and safe.
Resumo:
AIMS: It is unclear whether transcatheter aortic valve implantation (TAVI) addresses an unmet clinical need for those currently rejected for surgical aortic valve replacement (SAVR) and whether there is a subgroup of high-risk patients benefiting more from TAVI compared to SAVR. In this two-centre, prospective cohort study, we compared baseline characteristics and 30-day mortality between TAVI and SAVR in consecutive patients undergoing invasive treatment for aortic stenosis. METHODS AND RESULTS: We pre-specified different adjustment methods to examine the effect of TAVI as compared with SAVR on overall 30-day mortality: crude univariable logistic regression analysis, multivariable analysis adjusted for baseline characteristics, analysis adjusted for propensity scores, propensity score matched analysis, and weighted analysis using the inverse probability of treatment (IPT) as weights. A total of 1,122 patients were included in the study: 114 undergoing TAVI and 1,008 patients undergoing SAVR. The crude mortality rate was greater in the TAVI group (9.6% vs. 2.3%) yielding an odds ratio [OR] of 4.57 (95%-CI 2.17-9.65). Compared to patients undergoing SAVR, patients with TAVI were older, more likely to be in NYHA class III and IV, and had a considerably higher logistic EuroSCORE and more comorbid conditions. Adjusted OR depended on the method used to control for confounding and ranged from 0.60 (0.11-3.36) to 7.57 (0.91-63.0). We examined the distribution of propensity scores and found scores to overlap sufficiently only in a narrow range. In patients with sufficient overlap of propensity scores, adjusted OR ranged from 0.35 (0.04-2.72) to 3.17 (0.31 to 31.9). In patients with insufficient overlap, we consistently found increased odds of death associated with TAVI compared with SAVR irrespective of the method used to control confounding, with adjusted OR ranging from 5.88 (0.67-51.8) to 25.7 (0.88-750). Approximately one third of patients undergoing TAVI were found to be potentially eligible for a randomised comparison of TAVI versus SAVR. CONCLUSIONS: Both measured and unmeasured confounding limit the conclusions that can be drawn from observational comparisons of TAVI versus SAVR. Our study indicates that TAVI could be associated with either substantial benefits or harms. Randomised comparisons of TAVI versus SAVR are warranted.
Resumo:
So far, implantation is a poorly understood process, which involves several paradoxical cell-biological mechanisms. First, 50% of the embryo is paternal and immunologically foreign material, and second, both the endometrium and embryo are covered by epithelial tissue to prevent cellular fusion. The adhesion and invasion of the blastocyst require an accurate coordination of embryonic and endometrial physiology and the modulation of maternal immune tolerance. Endometrial function plays an important role in assisted reproduction. Pathologies such as fibroids, hydrosalpinges, endometriosis and the polycystic ovary syndrome have a significant negative impact on implantation but can be treated in most cases. Therapeutic strategies to improve endometrial and embryonic function in recurrent implantation disorders are however still controversially discussed.