897 resultados para Heterozygosity-fitness correlation
Resumo:
Background: A better physical fitness may have survival advantages in adults. Aim: To analyze the relationship between cardiorespiratory fitness and cardiovascular risk factors among obese subjects aged 58 years and older. Material and Methods: Cardiorespiratory fitness using the six-minute walk test, body composition by dual-energy x-ray absorptiometry and blood pressure were measured in a non-representative sample of 76 obese Portuguese subjects aged 58 to 87 years (55 women). Participants were stratified in tertiles of walking capacity according to the six-minute walk test. Results: Six minutes walk test results were negatively correlated with percentage body fat (r = -0.28; p = 0.012) and systolic blood pressure (r = -0.23; p = 0.045). Participants located in the lowest tertile for the six minutes walk test had an odds ratio of 4.34 (95% confidence intervals: 1.02-18.43) for elevated blood pressure. Conclusions: A lower six minutes walk test result is associated with a higher risk for high blood pressure. (Rev Med Chile 2012; 140: 1164-1169).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: It was reported that autonomic nervous system function is altered in subjects with chronic obstructive pulmonary disease (COPD). We evaluated short-and long-term fractal exponents of heart rate variability (HRV) in COPD subjects.Patients and methods: We analyzed data from 30 volunteers, who were divided into two groups according to spirometric values: COPD (n = 15) and control (n = 15). For analysis of HRV indices, HRV was recorded beat by beat with the volunteers in the supine position for 30 minutes. We analyzed the linear indices in the time (SDNN [standard deviation of normal to normal] and RMSSD [root-mean square of differences]) and frequency domains (low frequency [LF], high frequency [HF], and LF/HF), and the short-and long-term fractal exponents were obtained by detrended fluctuation analysis. We considered P < 0.05 to be a significant difference.Results: COPD patients presented reduced levels of all linear exponents and decreased short-term fractal exponent (alpha-1: 0.899 +/- 0.18 versus 1.025 +/- 0.09, P = 0.026). There was no significant difference between COPD and control groups in alpha-2 and alpha-1/alpha-2 ratio.Conclusion: COPD subjects present reduced short-term fractal correlation properties of HRV, which indicates that this index can be used for risk stratification, assessment of systemic disease manifestations, and therapeutic procedures to monitor those patients.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Sleep-deprived rats exhibit defensive fighting as well as explosive flights very similar to the wild-running of audiogenic seizures. In order to determine why sleep deprivation is a common factor that facilitates both panic and convulsive manifestations, the present study was undertaken to investigate whether rats that display sleep deprivation-induced fighting (SDIF) are the same as those that are susceptible to audiogenic wild-running (WR). Twenty-eight male adult Wistar rats were divided into two groups assigned to two e-sleep deprivation for 5 days and had their SDIF evaluated in social experimental schemes. In the first, 18 subjects were submitted to REM grouping. After 1 week for recovery, their susceptibility to WR was tested in an acoustic stimulation trial ( 104 dB, 200 Hz, 60 S). Rats that did not present WR received a lactate infusion and were tested again by acoustic stimulation 40 min later. In the second experimental scheme, 10 subjects were initially evaluated for WR susceptibility and the number of SDIF was recorded in social grouping after I week. Three categories of WR-susceptibility were determined: WR-sensitive rats, intermediate WR-sensitive rats and WR-insensitive rats. T'he number of SDIF in each category was significantly different and there was a high positive correlation (r=0.89; Spearman test) between the number of SDIF and the level of WR-susceptibility. We conclude that the reasons why sleep deprivation exerts facilitatory effects on both panic and convulsive manifestations are due to overlappings of neural pathways responsible for both behavioral patterns and for the property of sleep deprivation to increase neuronal excitability. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
The restriction of physical fitness is directly related with hypertension and sleep disorders, while the respiratory muscle strength is associated with hypertension, but the literature is scarce regarding its relationship with sleep disorders and particularly with excessive daytime sleepiness. Objectives: To compare physical fitness and strength of respiratory muscles between people with hypertension with excessive daytime sleepiness (EDS) and non EDS people, those who do not feel excessive daytime sleepiness, in addition to relate aerobics resistance and functional mobility of patients. Methods: An observational, analytical and transversal study, evaluated 32 elderly with hypertension, divided into two groups (EDS and non EDS), in which the following topics were measured; respiratory muscular strength, functional fitness, level of physical activity, level of excessive daytime sleepiness, quality of sleep and intensity of the patients snoring. Results: There was a significant difference in the level of EDS (P=0,00) and quality of sleep (p=0,03), however, the data related to snoring intensity (p=0,18), maximum inspiratory pressure PImax (p=0,39) and maximum expiratory pressure PEmax (p=0,98) did not show any difference. Also, no significant difference was observed concerning physical fitness, presenting p=0,08 for the sitting and getting up test on the chair in 30 ; p=0,54 for the extension and flexing of the elbow test in 30 ; p=0,38 for the walking test 6 ; p=0,38 for the parking gear test 2 , p=0,08 for the sitting and reaching test; p=0,42 for the scratching the back test; p=0,49 for the getting up and walking test; and p=0,62 for the global rate of activity limitation. There was moderate positive correlation between 6MWT and 2MST, r=0,54 (p=0,01) and negative moderate correlation between 6MWT and TUG, r=-0,61 (p=0,000) and between 2MST and TUG, r=-0,60 (p=0,000). Conclusion: The presence of EDS in the hypertension people studied, showed a bad quality of sleep, however this sleepiness did not influence the strength of the respiratory muscles. The physical fitness came out diminished in all hypertension people, regardless of the presence or non presence of sleep disturbance; and there is a close relationship between cardiovascular resistance and physical mobility, since when there is less cardiovascular resistance, there is precarious physical mobility and vice-versa
Resumo:
Introduction: The ability to walk is impaired in obese by anthropometric factors (BMI and height), musculoskeletal pain and level of inactivity. Little is known about the influence of body adiposity and the acute response of the cardiovascular system during whole the 6-minute walk test (6mWT). Objective: To evaluate the effect of anthropometric measures (BMI and WHR waist-to-hip ratio), the effort heart and inactivity in ability to walk the morbidly obese. Materials and Methods: a total 36 morbidly obese (36.23 + 11.82 years old, BMI 49.16 kg/m2) were recruited from outpatient department of treatment of obesity and bariatric surgery in University Hospital Onofre Lopes and anthropometric measurements of obesity (BMI and WHR), pulmonary function, pattern habitual physical activity (Baecke Questionnaire) and walking capacity (6mWT). The patient was checking to measure: heart rate (HR), breathing frequency (BF), peripheral oxygen saturation, level of perceived exertion, systemic arterial pressure and duplo-produto (DP), moreover the average speed development and total distance walking. The data were analysed between gender and pattern of body adiposity, measuring the behavior minute by minute of walking. The Pearson and Spearmam correlation coefficients were calculated, and stepwise multiple Regression examined the predictors of walking capacity. All analyses were performed en software Statistic 6.0. Results: 20 obese patients had abdominal adiposity (WHR = 1.01), waist circumference was 135.8 cm in women (25) and 139.8 cm in men (10). Walked to the end of 6mWT 412.43 m, with no differences between gender and adiposity. The total distance walked by obesity alone was explained by BMI (45%), HR in the sixth minute (43%), the Baecke (24%) and fatigue (-23%). 88.6% of obese (31) performed the test above 60% of maximal HR, while the peak HR achieved at 5-minute of 6mWT. Systemic arterial pressure and DP rised after walking, but with no differences between gender and adiposity. Conclusion: The walk of obese didn´t suffers influence of gender or the pattern of body adiposity. The final distance walked is attributed to excess body weight, stress heart, the feeling of effort required by physical activity and level of sedentary to obese. With a minute of walking, the obeses achieved a range of intensity cardiovascular trainning
Resumo:
Very intense visible green photoluminescence (PL) was observed at room temperature in structurally ordered-disordered BaZrO3 powders. Ab initio calculations, ultraviolet-visible absorption spectroscopy, electron paramagnetic resonance, and PL were performed. Theoretical and experimental results showed that local defects in the cubic structure caused by [ZrO5 center dot V-O(z)] complex clusters, where V-O(z) = V-O(x), V-O(center dot), and V-O(center dot center dot), play an important role in the formation of hole-electron pairs, giving rise to a charge gradient in the structure which is responsible for PL emission. (c) 2008 American Institute of Physics.
Resumo:
Diamond-like carbon (DLC) films were grown from radiofrequency plasmas of acetylene-argon mixtures, at different excitation powers, P. The effects of this parameter on the plasma potential, electron density, electron temperature, and plasma activity were investigated using a Langmuir probe. The mean electron temperature increased from about 0.5 to about 7.0 eV while the mean electron density decreased from about 1.2x10(9) to about 0.2x10(9) cm(-3) as P was increased from 25 to 150 W. Both the plasma potential and the plasma activity were found to increase with increasing P. Through actinometric optical emission spectrometry, the relative concentrations of CH, [CH], and H, [H], in the discharge were mapped as a function of the applied power. A rise in [H] and a fall in [CH] with increasing P were observed and are discussed in relation to the plasma characteristics and the subimplantation model. The optical properties of the films were calculated from ultraviolet-visible spectroscopic data; the surface resistivity was measured by the two-point probe method. The optical gap, E(G), and the surface resistivity, rho(s), fall with increasing P. E(G) and rho(s) are in the ranges of about 2.0-1.3 eV and 10(14)-10(16) Omega/square, respectively. The plasma power also influences the film self-bias, V(b), via a linear dependence, and the effect of V(b) on ion bombardment during growth is addressed together with variation in the relative densities of sp(2) and sp(3) bonds in the films as determined by Raman spectroscopy.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The general assumption under which the (X) over bar chart is designed is that the process mean has a constant in-control value. However, there are situations in which the process mean wanders. When it wanders according to a first-order autoregressive (AR (1)) model, a complex approach involving Markov chains and integral equation methods is used to evaluate the properties of the (X) over bar chart. In this paper, we propose the use of a pure Markov chain approach to study the performance of the (X) over bar chart. The performance of the chat (X) over bar with variable parameters and the (X) over bar with double sampling are compared. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]