937 resultados para HPLC-UV-PAD


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and reproducible method was developed for the assay of lomefloxacin in tablets. The excipients in the commercial tablet preparation did not interfere with the assay. Beer's law is obeyed in the range 2.0-9.0 μg.mL-1 at λmax 280 nm. The molar absorptivity was calculated. Six triplicate analyses of solutions containing six different concentrations of the examined drug were carried out and gave a mean correlation coefficient 0.9997. The proposed method was applied to the determination of the examined drug in coated tablet and the results demonstrated that the method is equally accurate, precise and reproducible as the official methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eremanthus seidelii MacLeish & Schumacher has a restricted occurrence to the Brazilian cerrado surrounding the Furnas (MG) reservoir, in environments that have been seriously damaged by human activity. The present phytochemical investigation reveals that the sesquiterpene lactones (SL) 4β,5-dihydro-2′,3′-dihydroxy-15-desoxy-goyazensolide (1) and 4β,5-dihydro-1′,2′-epoxy-eremantholide-C (2) are the major secondary metabolites in E. seidelii leaves, and an HPLC method was developed for their quantitative analysis. HPLC analysis showed no significant seasonal variation in the concentrations of both SL. No qualitative differences were found in the SL patterns of all individuals sampled. However, there is a different SL quantitative pattern among the plants analyzed, pointing to the existence of three quantitative chemotypes of this species, with differences possibly originating from the activity of the enzymes that cyclize the goyazensolide type SL (1) to a eremantholide type SL (2). ©2005 Sociedade Brasileira de Química.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Until mid 2006, SCIAMACHY data processors for the operational retrieval of nitrogen dioxide (NO2) column data were based on the historical version 2 of the GOME Data Processor (GDP). On top of known problems inherent to GDP 2, ground-based validations of SCIAMACHY NO2 data revealed issues specific to SCIAMACHY, like a large cloud-dependent offset occurring at Northern latitudes. In 2006, the GDOAS prototype algorithm of the improved GDP version 4 was transferred to the off-line SCIAMACHY Ground Processor (SGP) version 3.0. In parallel, the calibration of SCIAMACHY radiometric data was upgraded. Before operational switch-on of SGP 3.0 and public release of upgraded SCIAMACHY NO2 data, we have investigated the accuracy of the algorithm transfer: (a) by checking the consistency of SGP 3.0 with prototype algorithms; and (b) by comparing SGP 3.0 NO2 data with ground-based observations reported by the WMO/GAW NDACC network of UV-visible DOAS/SAOZ spectrometers. This delta-validation study concludes that SGP 3.0 is a significant improvement with respect to the previous processor IPF 5.04. For three particular SCIAMACHY states, the study reveals unexplained features in the slant columns and air mass factors, although the quantitative impact on SGP 3.0 vertical columns is not significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to establish reference values for hemoglobins (Hb) using HPLC, in samples containing normal Hb (AA), sickle cell trait without alpha-thalassemia (AS), sickle cell trait with alpha-thalassemia (ASH), sickle cell anemia (SS), and Hb SC disease (SC). The blood samples were analyzed by electrophoresis, HPLC and molecular procedures. The Hb A2 mean was 4.30 ± 0.44% in AS, 4.18 ± 0.42% in ASH, 3.90 ± 1.14% in SS, and 4.39 ± 0.35% in SC. They were similar, but above the normal range. Between the AS and ASH groups, only the amount of Hb S was higher in the AS group. The Hb S mean in the AS group was 38.54 ± 3.01% and in the ASH it was 36.54 ± 3.76%. In the qualitative analysis, using FastMap, distinct groups were seen: AA and SS located at opposite extremes, AS and ASH with overlapping values and intermediate distribution, SC between heterozygotes and the SS group. Hb S was confirmed by allele-specific polymerase chain reaction. The Hb values established will be available for use as a reference for the Brazilian population, drawing attention to the increased levels of Hb A2, which should be considered with caution to prevent incorrect diagnoses. ©FUNPEC-RP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 2-month-old dog was presented with injuries involving both hind paws. Only the 5th digit and its digital pad were present on the right paw. Following a full-thickness skin graft, the 5th digital pad was transferred distal to the metatarsal bones. The transferred pad permitted weight-bearing on the limb.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooperative energy-transfer upconversion luminescence in Tb 3+/Yb 3+-codoped PbGeO 3-PbF 2-CdF 2 vitroceramic and its precursor glass under resonant and off-resonance infrared excitation, is investigated. Bright UV-visible emission signals around 384, 415, 438 nm, and 473-490, 545, 587, and 623 nm, identified as due to the 5D 3( 5G 6 → 7F J(J=6,5,4) and 5D 4 → 7F J(J=6,5,4,3) transitions, respectively, were readily observed. The results indicate that cooperative energy-transfer between ytterbium and terbium ions followed by excited-state absorption are the dominant upconversion excitation mechanisms herein involved. The comparison of the upconversion process in a vitroceramic sample and its glassy precursor revealed that the former present much higher upconversion efficiency. The dependence of the upconversion emission upon pump power, temperature, and doping content is also examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hemoglobinopathies were included in the Brazilian Neonatal Screening Program on June 6, 2001. Automated high-performance liquid chromatography (HPLC) was indicated as one of the diagnostic methods. The amount of information generated by these systems is immense, and the behavior of groups cannot always be observed in individual analyses. Three-dimensional (3-D) visualization techniques can be applied to extract this information, for extracting patterns, trends or relations from the results stored in databases. We applied the 3-D visualization tool to analyze patterns in the results of hemoglobinopathy based on neonatal diagnosis by HPLC. The laboratory results of 2520 newborn analyses carried out in 2001 and 2002 were used. The Fast, F1, F and A peaks, which were detected by the analytical system, were chosen as attributes for mapping. To establish a behavior pattern, the results were classified into groups according to hemoglobin phenotype: normal (N = 2169), variant (N = 73) and thalassemia (N = 279). 3-D visualization was made with the FastMap DB tool; there were two distribution patterns in the normal group, due to variation in the amplitude of the values obtained by HPLC for the F1 window. It allowed separation of the samples with normal Hb from those with alpha thalassemia, based on a significant difference (P > 0.05) between the mean values of the Fast and A peaks, demonstrating the need for better evaluation of chromatograms; this method could be used to help diagnose alpha thalassemia in newborns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The intension of this paper was to review and discuss some of the current quantitative analytical procedures which are used for quality control of pharmaceutical products. The selected papers were organized according to the analytical technique employed. Several techniques like ultraviolet/visible spectrophotometry, fluorimetry, titrimetry, electroanalytical techniques, chromatographic methods (thin-layer chromatography, gas chromatography and high-performance liquid chromatography), capillary electrophoresis and vibrational spectroscopies are the main techniques that have been used for the quantitative analysis of pharmaceutical compounds. In conclusion, although simple techniques such as UV/VIS spectrophotometry and TLC are still extensively employed, HPLC is the most popular instrumental technique used for the analysis of pharmaceuticals. Besides, a review of recent works in the area of pharmaceutical analysis showed a trend in the application of techniques increasingly rapid such as ultra performance liquid chromatography and the use of sensitive and specific detectors as mass spectrometers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Triamcinolone (TRI), a drug widely used in the treatment of ocular inflammatory diseases, is practically insoluble in water, which limits its use in eye drops. Cyclodextrins (CDs) have been used to increase the solubility or dissolution rate of drugs. The purpose of the present study was to validate a UV-Vis spectrophotometric method for quantitative analysis of TRI in inclusion complexes with beta-cyclodextrin (B-CD) associated with triethanolamine (TEA) (ternary complex). The proposed analytical method was validated with respect to the parameters established by the Brazilian regulatory National Agency of Sanitary Monitoring (ANVISA). The analytical measurements of absorbance were made at 242nm, at room temperature, in a 1-cm path-length cuvette. The precision and accuracy studies were performed at five concentration levels (4, 8, 12, 18 and 20μg.mL -1). The B-CD associated with TEA did not provoke any alteration in the photochemical behavior of TRI. The results for the measured analytical parameters showed the success of the method. The standard curve was linear (r2 > 0.999) in the concentration range from 2 to 24 μg.mL -1. The method achieved good precision levels in the inter-day (relative standard deviation-RSD <3.4%) and reproducibility (RSD <3.8%) tests. The accuracy was about 80% and the pH changes introduced in the robustness study did not reveal any relevant interference at any of the studied concentrations. The experimental results demonstrate a simple, rapid and affordable UV-Vis spectrophotometric method that could be applied to the quantitation of TRI in this ternary complex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recovery of phenolic compounds of Eugenia pyriformis using different solvents was investigated in this study. The compounds were identified and quantified by reverse-phase high-performance liquid chromatography coupled with ultraviolet-visible diode-array detector (RP-HPLC-DAD/UV-vis). Absolute methanol was the most effective extraction agent of phenolic acids and flavonols (588.31 mg/Kg) from Eugenia pyriformis, although similar results (p ≤ 0.05) were observed using methanol/water (1:1 ratio). Our results clearly showed that higher contents of phenolic compounds were not obtained either with the most or the least polar solvents used. Several phenolic compounds were identified in the samples whereas gallic acid and quercetin were the major compounds recovered. © 2012 Association of Food Scientists & Technologists (India).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glycomacropeptide is a glycosilated fraction of bovine kappa-casein that remains soluble when milk is clotted by rennin. Determinations of milk sialic acid content are useful because its concentration reflects the amount of free GMP of milk. In normal milk these amounts are very low, 12 to 16 times lower than in sweet whey. Therefore, its determination may be applied to verify possible frauds with whey addictions, since it works as a fingerprint. With the description of a new spectrophotometric method for determination of free GMP (ANSM) occurred a simplification of procedures, being faster than others (HPLC method), without loss of accuracy. However, due to variations of glycosilation in kappa-casein between animals, during the lactation period, due to mastitis and yet due to proteolysis on milk, it was necessary to know these variations to interpret correctly the analytical results. It was analyzed 1,703 samples of producer's raw milk and 1,189 samples of processed milk (HTST and UHT). The results showed that normal milk from herd (producer's milk) have only small amounts of free GMP, with A470nm = 0.232±0.088 or 3.89±1.25 mg of sialic acid/L. The upper limit of this distribution was A = 0.496; thus every bigger value may represent a problem, being outside of normal distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A HPLC-ESI-IT-MSn method, based on high-performance liquid chromatography coupled to electrospray negative ionization multistage ion trap mass spectrometry, was developed for rapid identification of 24 flavonoid and naphthopyranone compounds. The methanol extracts of the capitulae and scapes of P. chiquitensis exhibited mutagenic activity in the Salmonella/microsome assay, against strain TA97a. © 2013 by the authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gastrotoxicity is a major problem for long-term therapy with non-steroidal anti-inflammatory drugs (NSAIDs). DICCIC (1-(2,6-dichlorophenyl)indolin-2-one) is a new diclofenac prodrug, which has proven anti-inflammatory activity without gastroulcerogenic effect. The aim of this work was to compare the pharmacokinetic profiles of diclofenac from DICCIC (7.6 mg/kg equivalent to 8.1 mg/kg diclofenac) and diclofenac (8.1 mg/kg) administration in Wistar rats weighing 250-300 g (n=20). The doses were calculated by interspecific allometric scaling based on the 2 mg/kg from diary human dose of diclofenac. Blood samples were collected in heparinized tubes via the femoral artery through the implanted catheter. The plasma was separated and quantitation was made in a HPLC system with a UV-Vis detector. The confidence limits of the bioanalytical method were appropriate for its application in a preclinical pharmacokinetic study. The AUC of diclofenac from DICCIC (53.7± 5.8 ug/mL.min) was significantly less (Mann Whitney test, p<0.05) than that of diclofenac from diclofenac administration (885.9 ± 124,8 ug/mL.min). Terminal half-life of diclofenac from DICCIC (50.1 ± 17.2 min) was significantly less (Mann Whitney test, p<0.05) than that of diclofenac from diclofenac administration (247.4 ± 100.9 min). Still the parameters clearance and distribution volume were calculated for diclofenac from diclofenac, whose results were 9.2 ±1.2 mL/min.kg and 3.3 ±1.2 L/kg, respectively. The results of DICCIC from DICCIC administration were 108.9 ± 19.6 mL/min.kg and 7.8 ± 2.4 L/kg for clearance and distribution volume, respectively. The pharmacokinetic profile demonstrated that there was an increase in diclofenac elimination and a lower exposure to diclofenac with administration of DICCIC compared to diclofenac. © 2013 Bentham Science Publishers.