886 resultados para Grafting.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Assessment of postoperative quality of life in patients over 80 years after cardiac surgery including coronary artery bypass grafting (CABG), aortic valve replacement (AVR) and combined procedures. METHODS: Quality of life of n=136 patients over 80 years at operation (82.3+/-2.1 years), undergoing isolated CABG in 61 patients (45%), isolated AVR in 34 patients (25%) and a combination of CABG and AVR in 41 patients (30%) between January 1999 and December 2003 was reviewed. Preoperatively 66.2% presented in NYHA-class III/IV or CCS-class III/IV. Mean ejection fraction (EF) was 59.5%+/-14.0 (range 25-90%). Quality of life assessment was performed via a Seattle Angina Questionnaire. Follow-up was 100% complete for a total of 890 days (69-1853 days). RESULTS: Five-year survival was 70% for the CABG group, 75% for the AVR group and 65% for the CABG/AVR group. Quality of life was remarkable in all of the three groups after surgery. Overall 97 patients (81%) were not or little disabled in their daily activity. One hundred and twelve patients (93%) were free or considerably less symptomatic. Seventy-eight patients or 65% reported to be very satisfied with their current quality of life and 112 patients (93%) felt very reassured to have continuous full access to medical treatment despite of their advanced age. CONCLUSIONS: A remarkable quality of life and important improvement in the functional status after cardiac surgery in patients over 80 paired with a satisfactory medium-term survival justify early intervention for heart disease in this age group. Therefore, referral practice for patients over 80 years for heart surgery should be handled liberally.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Integrins are a family of transmembrane adhesion receptors that might transduce signals from the extracellular matrix into the inside of cells after ligand binding. In order to investigate whether beta3 integrins expressed in tumor cells might mediate such outside-in signaling, human MDA-MB-231 breast cancer cells that were stably transfected with either beta3 integrin or mock-transfected were investigated in a matrigel degradation assay and a grafting experiment was performed on the developing chicken chorioallantoic membrane (CAM). After cultivation on matrigel for time periods between one and five days, more matrigel was digested in the wells in which beta3 integrin expressing cells were incubated than in wells of mock-transfected cells. Furthermore, extracts of beta3 integrin expressing cells contained higher levels of MMP-2 protein as determined by immunoblotting and more MMP-2 associated gelatinase activity as detected by zymography than extracts of mock-transfected cells. Matrigel degradation and gelatinase activity as well as MMP-2 expression were elevated when beta3 integrin expressing cells were incubated in the presence of the RGD peptide (mimicking an integrin ligand). After grafting on 10 day-old embryonic chicken CAM for three to five days, beta3 integrin expressing cells assembled in spheroids showed higher rates of spreading on the CAM surface and CAM invasion as well as a significant MMP-2 up-regulation compared to mock-transfected cells. The results from the in vivo and in vitro experiments allow the conclusion that the presence of beta3 integrin in MDA-MB-231 breast cancer cells induced an increased MMP-2 expression and activity that might contribute to the enhanced invasive potential observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reconstruction of the anterior skull base and fronto-orbital framework following extensive tumor resection is both challenging and controversial. Dural defects are covered with multiple sheets of fascia lata that provide sufficient support and avoid herniation. Plating along the skull base is contraindicated. After resection of orbital walls, grafting is necessary if the periosteum or parts of the periorbital tissue had to be removed, to avoid enophthalmus or strabism. Free bone grafts exposed to the sinonasal or pharyngeal cavity are vulnerable to infection or necrosis: therefore, covering the grafts with vascularized tissue, such as the Bichat fat-pad or pedicled temporalis flaps, should reduce these complications. Alloplastic materials are indispensable in cranial defects, whereas microsurgical free tissue transfer is indicated in cases of orbital exenteration and skin defects. The authors review their experience and follow-up of 122 skull base reconstructions following extensive subcranial tumor resection. Most significant complications were pneumocranium in 4.9%, CSF leaks in 3.2%, and partial bone resorption in 8.1%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulmonary embolism is very rarely reported early after cardiac surgery, most probably due to full heparinisation during cardiopulmonary bypass. We report a 66-year-old man without thromboembolic history who presented three days after a coronary artery bypass grafting procedure with acute dyspnoea and haemodynamic instability. A CT scan confirmed paracentral bilateral pulmonary embolism requiring an urgent and successful embolectomy. Review of the literature confirms that pulmonary embolism may occur in up to 3% of post-cardiopulmonary bypass patients. The possibility of pulmonary embolism must be taken into consideration in post-cardiopulmonary bypass patients with acute onset of chest pain and respiratory insufficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The standard heart-lung machine is a major trigger of systemic inflammatory response and the morbidity attributed to conventional extracorporeal circulation (CECC) is still significant. Reduction of blood-artificial surface contact and reduction of priming volume are principal aims in minimized extracorporeal circulation (MECC) cardiopulmonary bypass systems. The aim of this paper is to give an overview of the literature and to present our experience with the MECC-smart suction system. METHODS AND RESULTS: At our institution, 1799 patients underwent isolated coronary artery bypass grafting (CABG) surgery, 1372 with a MECC-smart suction system and 427 with CECC. All in-hospital data were assessed and the results were compared between the 2 groups. Patient characteristics and the distribution of EuroSCORE risk profile in our collective were similar between both groups. Average age in the MECC collective was 67.5 +/- 11.4 years and average EuroSCORE was 5.0 +/- 1.5. Average number of distal anastomoses was similar to the average number encountered in patients undergoing CABG surgery with CECC (3.3 +/- 1.0 for MECC versus 3.2 +/- 1.1 for CECC; P = ns). Myocardial protection is superior in MECC patients with lower postoperative maximal cTnI values (11.0 +/- 10.8 micromol/L for MECC versus 24.7 +/- 25.3 micromol/L for CECC; P < .05). Postoperative recovery was faster in patients operated on with the MECC-smart suction system and discharge from the hospital was earlier than for CECC patients (7.4 +/- 1.9 days for MECC versus 8.8 +/- 3.8 days for CECC; P < .05). CONCLUSIONS: The MECC-smart suction system is a safe perfusion technique for CABG surgery. In patients operated on with this system, the clinical outcome seems to be better than in patients operated on with CECC. This promising and less damaging perfusion technology has the potential to replace CECC systems in CABG surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The stability of 2 fixation techniques for the tuberosities in patients with 3- or 4-part proximal humerus fractures treated with hemiarthroplasties was compared. DESIGN: Retrospective review of a nonrandomized sequential series of patients. SETTING: Level I university orthopaedic surgery department. PATIENTS: A consecutive series of 58 patients (average age, 64 years) from 1990 to 1999 with 3- and 4-part fractures of the proximal humerus. INTERVENTION: In group 1, 31 patients were treated with either a Neer or Aequalis shoulder prosthesis using nonabsorbable sutures and no bone graft for the reattachment of the tuberosities. In group 2, 27 patients were treated with either an Aequalis or Epoca shoulder prosthesis and a combination of cable fixation and bone grafting. MAIN OUTCOME MEASUREMENTS: At follow-up (average, 32 months), radiographs were taken to confirm tuberosity fixation or degree of displacement or resorption. Functional outcome was assessed by the Constant-Murley Score. RESULTS: Significantly more dislocated tuberosities were found radiographically in group 1 (10 of 13 in total, P = 0.011), and significantly more tuberosities were resorbed in group 1 (9 of 12 in total, P = 0.012). Significant differences in functional results among healed versus failed tuberosity fixation were observed for activity of daily living (P = 0.05), range of motion (P = 0.002), strength (P = 0.01), the total score (P = 0.008), and the passive rotation amplitude (P = 0.04). CONCLUSION: In hemiarthroplasties for proximal humeral fractures, the reattachment of the tuberosities with cable wire and bone grafting gives consistently better radiographic and functional results than with suture fixation alone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To compare the histological features of bone filled with Bio-Oss, Ostim-Paste or PerioGlas placed in defects in the rabbit tibiae by evaluating bone tissue composition and the integration of titanium implants placed in the grafted bone. MATERIAL AND METHODS: Two cylindrical bone defects, about 4 mm in diameter and 6 mm in depth, were created in the tibiae of 10 rabbits. The defects were filled with either Bio-Oss, PerioGlas, Ostim-Paste or left untreated, and covered with a collagen membrane. Six weeks later, one titanium sandblasted and acid-etched (SLA) implant was inserted at the centre of each previously created defect. The animals were sacrificed after 6 weeks of healing. RESULTS: Implants placed in bone previously grafted with Bio-Oss, PerioGlas or Ostim-Paste obtained a larger extent of osseointegration, although not statistically significant, than implants placed in non-grafted bone. The three grafting materials seemed to perform in a similar way concerning their contribution towards implant osseointegration. All grafting materials appeared to be osteoconductive, thus leading to the formation of bridges of mineralized bone extending from the cortical plate towards the implants surface through the graft scaffold. CONCLUSIONS: Grafting with the above-mentioned biomaterials did not add any advantage to the osseointegration of titanium SLA implants in a self-contained defect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: To evaluate the healing outcome of soft tissue dehiscence coverage at implant sites. MATERIAL AND METHODS: Ten patients with one mucosal recession defect at an implant site and a contralateral unrestored clinical crown without recession were recruited. The soft tissue recessions were surgically covered using a coronally advanced flap in combination with a free connective tissue graft. Healing was studied at 1, 3 and 6 months post-operatively. RESULTS: Soft tissue dehiscences were covered with a coronal overcompensation of the flap margin up to 1.2 mm after the procedure. After 1 month, the coverage shrank to a mean of 75%, after 3 months to 70% and after 6 months to 66%. CONCLUSIONS: The implant sites revealed a substantial, clinically significant improvement following coronal mucosal displacement in combination with connective tissue grafting, but in none of the sites, a could complete implant soft tissue dehiscence coverage be achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Diabetes mellitus (DM) and renal insufficiency (RI) were shown to be associated with an obstructive lesion pattern favouring distal lower limb arterial segments in patients with peripheral arterial disease (PAD). We hypothesized that presence of DM is associated with pronounced involvement of the tibioperoneal arteries, whereas RI predominantly affects the pedal arch. PATIENTS AND METHODS: A consecutive series of PAD patients (mean age 75 +/- 10 years, 40 women) with RI alone (n = 15), RI and DM (n = 25), DM alone (n = 25) and without RI or DM (n = 25) underwent diagnostic angiography. We analyzed the obstructive burden of different segments of the infrageniculate arterial tree using the Bollinger score as well as accessibility of pedal arteries for bypass surgery. RESULTS: In patients with DM and in patients with RI the mean total obstructive burden was higher in pedal as compared to tibioperoneal arteries (9.79 +/- 4.60 vs. 6.99 +/- 3.45, p = 0.03;10.50 +/- 5.53 vs. 6.88 +/- 4.12, p = 0.05, respectively). However, rates of patency of at least one pedal artery were significantly lower in patients with RI and RI/DM as compared to controls (47% and 48% vs. 80%, respectively; p = 0.007), whereas patency was comparable between patients with diabetes alone and controls (72% vs. 80%, ns). Rates of viability of pedal arteries as an attachment site for distal bypass was 80%, 68%, 47% and 44% in controls, patients with DM alone, RI alone and RI/DM, respectively (p = 0.0042). CONCLUSIONS: In contrast to previous anecdotal observations, both DM and RI are associated with a high atherosclerotic burden of the pedal arch in the present angiographic series. The presence of RI, however, is associated with a lower patency of the pedal arch as compared to the presence of DM alone, and more than fifty percent patients are unsuitable for distal bypass grafting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Flow mismatch between the supplying artery and the myocardial perfusion region has been observed in patients with internal thoracic artery grafts. Thus coronary flow changes of arterial (internal thoracic artery grafts) and saphenous (saphenous vein grafts) bypass grafts were studied early and late after coronary artery bypass grafting. METHODS: Thirty patients undergoing elective bypass surgery (internal thoracic artery and saphenous vein grafts) were studied intraoperatively and (17 patients) 3 to 10 months postoperatively. Coronary flow was measured intraoperatively with the transit-time Doppler scanning technique. Postoperatively, flow velocity and coronary flow reserve were determined with the Doppler flow wire technique. Quantitative angiographic analysis was used to determine vessel size for calculation of absolute flow. RESULTS: Intraoperatively, internal thoracic artery graft flow was significantly lower than saphenous vein graft flow (31 +/- 8 vs 58 +/- 29 mL/min, P < .01). Postoperatively, internal thoracic artery graft flow increased significantly to 42 +/- 24 mL/min at 3 months and to 56 +/- 30 mL/min (P < .02 vs intraoperative value) at 10 months, respectively. However, saphenous vein graft flow remained unchanged over time (58 +/- 29 to 50 +/- 27 mL/min at 3 months and 46 +/- 27 mL/min at 10 months). Coronary flow reserve was abnormally low intraoperatively in the internal thoracic artery (1.3 +/- 0.3) and saphenous vein (1.6 +/- 0.5) grafts but increased significantly to normal values in both types of graft at follow-up. CONCLUSIONS: Bypass flow of the internal thoracic artery graft is significantly reduced intraoperatively when compared with that of the saphenous vein graft. However, 3 and 10 months after the operation, flow of the internal thoracic artery graft increases significantly and is similar to saphenous vein graft flow. This finding can be explained by an early flow mismatch of the native internal thoracic artery in the presence of a large perfusion territory. During follow-up, there is vascular remodeling of the internal thoracic artery, probably because of endothelium-mediated mechanisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This retrospective study analyzed the pool of patients referred for treatment with dental implants over a 3-year period in a referral specialty clinic. Materials and Methods: All patients receiving dental implants between 2002 and 2004 in the Department of Oral Surgery and Stomatology, University of Bern, were included in this retrospective study. Patients were analyzed according to age, gender, indications for implant therapy, location of implants, and type and length of implants placed. A cumulative logistic regression analysis was performed to identify and analyze potential risk factors for complications or failures. Results: A total of 1,206 patients received 1,817 dental implants. The group comprised 573 men and 633 women with a mean age of 55.2 years. Almost 60% of patients were age 50 or older. The most frequent indication for implant therapy was single-tooth replacement in the maxilla (522 implants or 28.7%). A total of 726 implants (40%) were inserted in the esthetically demanding region of the anterior maxilla. For 939 implants (51.7%), additional bone-augmentation procedures were required. Of these, ridge augmentation with guided bone regeneration was performed more frequently than sinus grafting. Thirteen complications leading to early failures were recorded, resulting in an early failure rate of 0.7%. The regression analysis failed to identify statistically significant failure etiologies for the variables assessed. Conclusions: From this study it can be concluded that patients referred to a specialty clinic for implant placement were more likely to be partially edentulous and over 50 years old. Single-tooth replacement was the most frequent indication (> 50%). Similarly, additional bone augmentation was indicated in more than 50% of cases. Adhering to strict patient selection criteria and a standardized surgical protocol, an early failure rate of 0.7% was experienced in this study population

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate fracture patterns in bicondylar tibial plateau fractures and their impact on treatment strategy. DESIGN: Prospective data analysis with documentation of initial injury and treatment strategy, computed tomography scans, conventional x-rays, long-term evaluation of radiographs, and functional assessments. SETTING: Level 1 regional trauma center. PATIENTS: Prospective data acquisition of 14 consecutive patients (10 male and 4 female) with a bicondylar tibial plateau fracture (AO Type C). INTERVENTION: Application of a stepwise reconstruction strategy of the tibial plateau starting with the reposition and fixation of the posteromedial split fragment using a 3.5 buttress plate, followed by reposition and grafting of the lateral compartment and lateral fixation with a 3.5 plate in 90 degree to the medial fixation device. MAIN OUTCOME MEASUREMENTS: All patients were evaluated with full-length standing film, standardized x-rays, Lysholm score for functional assessment, and patient's self-appraisal. RESULTS: Most of the complex bicondylar fractures follow a regular pattern in that the medial compartment is split in a mediolateral direction with a posteromedial main fragment, combined with various amounts of multifragmental lateral compartment depression. The technique introduced allows for accurate and stable reduction and fixation of this fracture type. The final Lysholm knee score showed an average of 83.5 points (range: 64.5-92). CONCLUSIONS: Complex bicondylar tibial plateau fractures follow a regular pattern, which is not represented in existing 2-dimensional fracture classifications. A 2-incision technique starting with the reduction of the posteromedial edge results in accurate fracture reduction with low complication rates and excellent knee function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ventral mesencephalic (VM) precursor cells are of interest in the search for transplantable dopaminergic neurons for cell therapy in Parkinson's disease (PD). In the present study we investigated the survival and functional capacity of in vitro expanded, primary VM precursor cells after intrastriatal grafting to a rat model of PD. Embryonic day 12 rat VM tissue was mechanically dissociated and cultured for 4 or 8 days in vitro (DIV) in the presence of FGF2 (20 ng/ml), FGF8 (20 ng/ml) or without mitogens (control). Cells were thereafter differentiated for 6 DIV by mitogen withdrawal and addition of serum. After differentiation, significantly more tyrosine hydroxylase-immunoreactive (TH-ir), dopamine-producing neurons were found in FGF2- and FGF8-expanded cultures compared to controls. Moreover, expansion for 4 DIV resulted in significantly more TH-ir cells than expansion for 8 DIV both for FGF2 (2.4 fold; P<0.001) and FGF8 (3.8 fold; P<0.001) treated cultures. The functional potential of the expanded cells (4 DIV) was examined after grafting into striatum of aged 6-hydroxydopamine-lesioned rats. Amphetamine-induced rotations performed 3, 6 and 9 weeks postgrafting revealed that grafts of FGF2-expanded cells induced a significantly faster and better functional recovery than grafts of FGF8-expanded cells or control cells (P<0.05 for both). Grafts of FGF2-expanded cells also contained significantly more TH-ir cells than grafts of FGF8-expanded cells (P<0.05) or control cells (P<0.01). In conclusion, FGF2-mediated pregrafting expansion of primary VM precursor cells considerably improves dopaminergic cell survival and functional restoration in a rat model of PD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Basal cell carcinoma is the most frequent cutaneous cancer of the nose and is characterized by its local spreading and exceptionally rare tendency to metastasize. Since a significant advantage has been seen in surgery compared to other treatments, surgical excision ensuring the highest chance of cure is frequently employed. Excision defects of the nose may be covered with either local flap or a full-thickness skin graft. In resurfacing such defects following excision of basal cell carcinomas, we favor the technique of composite-skin grafting which involves the harvesting of composite-skin graft including the epidermis, dermis and superficial layers of subcutaneous tissue to obtain the required thickness in the recipient site. This technique was used for defects remaining after the excision of basal cell carcinomas in a series of 15 patients. The areas involved were lateral nasal region (5 cases), nasal tip (4 cases), dorsum (3 cases), alar lobule (2 cases), and soft triangle (1 case). The mean follow-up was 14.2 months. The color, texture and thickness of the composite-skin graft harvested from the preauricular site and the neck compare favorably with the skin of the nose region. Satisfactory results, both clinically and in patient appreciation, have been obtained in both the reconstruction site and the appearance of the donor site in all patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The coverage of recurrent pressure sores with unstable scar in the surrounding tissue is still an unsolved problem in the literature. Local and regional transfer of tissue often does not meet the requirements of the tissue deficit. Especially in recurrent pressure sores, the adjacent skin has already been consumed due to multiple surgeries. As a good alternative, the microsurgical transfer of flaps offers viable tissue to cover even large pressure sores. METHODS: We performed a total of six free flaps in five patients who suffered from intractable pressure sores in the hip region. The age of the patients was between 41 and 63 years. The defect size varied between 6 x 6 cm and 25 x 30 cm. Two combined myocutaneous scapula-latissimus dorsi, two myocutaneous latissimus dorsi, one anteromedial thigh, and one rectus femoris flap were used to cover the defects. RESULTS: The average follow-up time was 29 months. Flaps provided stable coverage in four of five patients at 12-month follow-up. There was one subtotal flap necrosis that was subsequently treated with split-thickness skin grafting. CONCLUSION: In this series of five patients with six free flaps, we were able to show that the microsurgical transfer of tissue is a valuable option in the treatment of difficult pressure sores. Even in older and debilitated patients, this method is a good alternative to conventional local flaps.