973 resultados para Finite field
Resumo:
Argentine singer-songwriter Juana Molina is one of those fearless artists. The kind of fearless artist who abandons a successful TV show at the height of its popularity to pursue a solo career in making and performing slightly left-field South American folk-tinged electronica...
Acceptability-based QoE management for user-centric mobile video delivery : a field study evaluation
Resumo:
Effective Quality of Experience (QoE) management for mobile video delivery – to optimize overall user experience while adapting to heterogeneous use contexts – is still a big challenge to date. This paper proposes a mobile video delivery system to emphasize the use of acceptability as the main indicator of QoE to manage the end-to-end factors in delivering mobile video services. The first contribution is a novel framework for user-centric mobile video system that is based on acceptability-based QoE (A-QoE) prediction models, which were derived from comprehensive subjective studies. The second contribution is results from a field study that evaluates the user experience of the proposed system during realistic usage circumstances, addressing the impacts of perceived video quality, loading speed, interest in content, viewing locations, network bandwidth, display devices, and different video coding approaches, including region-of-interest (ROI) enhancement and center zooming
Resumo:
Purpose Two diodes which do not require correction factors for small field relative output measurements are designed and validated using experimental methodology. This was achieved by adding an air layer above the active volume of the diode detectors, which canceled out the increase in response of the diodes in small fields relative to standard field sizes. Methods Due to the increased density of silicon and other components within a diode, additional electrons are created. In very small fields, a very small air gap acts as an effective filter of electrons with a high angle of incidence. The aim was to design a diode that balanced these perturbations to give a response similar to a water-only geometry. Three thicknesses of air were placed at the proximal end of a PTW 60017 electron diode (PTWe) using an adjustable “air cap”. A set of output ratios (ORfclin Det ) for square field sizes of side length down to 5 mm was measured using each air thickness and compared to ORfclin Det measured using an IBA stereotactic field diode (SFD). k fclin, f msr Qclin,Qmsr was transferred from the SFD to the PTWe diode and plotted as a function of air gap thickness for each field size. This enabled the optimal air gap thickness to be obtained by observing which thickness of air was required such that k fclin, f msr Qclin,Qmsr was equal to 1.00 at all field sizes. A similar procedure was used to find the optimal air thickness required to make a modified Sun Nuclear EDGE detector (EDGEe) which s “correction-free” in small field relative dosimetry. In addition, the feasibility of experimentally transferring k fclin, f msr Qclin,Qmsr values from the SFD to unknown diodes was tested by comparing the experimentally transferred k fclin, f msr Qclin,Qmsr values for unmodified PTWe and EDGEe diodes to Monte Carlo simulated values. Results 1.0 mm of air was required to make the PTWe diode correction-free. This modified diode (PTWeair) produced output factors equivalent to those in water at all field sizes (5–50 mm). The optimal air thickness required for the EDGEe diode was found to be 0.6 mm. The modified diode (EDGEeair) produced output factors equivalent to those in water, except at field sizes of 8 and 10 mm where it measured approximately 2% greater than the relative dose to water. The experimentally calculated k fclin, f msr Qclin,Qmsr for both the PTWe and the EDGEe diodes (without air) matched Monte Carlo simulated results, thus proving that it is feasible to transfer k fclin, f msr Qclin,Qmsr from one commercially available detector to another using experimental methods and the recommended experimental setup. Conclusions It is possible to create a diode which does not require corrections for small field output factor measurements. This has been performed and verified experimentally. The ability of a detector to be “correction-free” depends strongly on its design and composition. A nonwater-equivalent detector can only be “correction-free” if competing perturbations of the beam cancel out at all field sizes. This should not be confused with true water equivalency of a detector.
Resumo:
Solid-extracellular fluid interaction is believed to play an important role in the strain-rate dependent mechanical behaviors of shoulder articular cartilages. It is believed that the kangaroo shoulder joint is anatomically and biomechanically similar to human shoulder joint and it is easy to get in Australia. Therefore, the kangaroo humeral head cartilage was used as the suitable tissue for the study in this paper. Indentation tests from quasi-static (10-4/sec) to moderately high strain-rate (10-2/sec) on kangaroo humeral head cartilage tissues were conduced to investigate the strain-rate dependent behaviors. A finite element (FE) model was then developed, in which cartilage was conceptualized as a porous solid matrix filled with incompressible fluids. In this model, the solid matrix was modeled as an isotropic hyperelastic material and the percolating fluid follows Darcy’s law. Using inverse FE procedure, the constitutive parameters related to stiffness, compressibility of the solid matrix and permeability were obtained from the experimental results. The effect of solid-extracellular fluid interaction and drag force (the resistance to fluid movement) on strain-rate dependent behavior was investigated by comparing the influence of constant, strain dependent and strain-rate dependent permeability on FE model prediction. The newly developed porohyperelastic cartilage model with the inclusion of strain-rate dependent permeability was found to be able to predict the strain-rate dependent behaviors of cartilages.
Resumo:
Cool roof coatings are identified by their solar reflectance index. They have been reported to have multiple benefits, the extent of which are strongly dependent on the peculiarities of the local climate, building stock and electricity network. This paper presents measured and simulated data from residential, educational and commercial buildings involved in recent field trials in Australia. The purpose of the field trials was to evaluate the impact of such coatings on electricity demand and load and to assess their potential application to improve comfort whilst avoiding the need for air conditioners. Measured reductions in temperature, power (kW) and energy (kWh) were used to develop a predictive model that correlates ambient temperature distribution profiles, building demand reduction profiles and electricity network peak demand times. Combined with simulated data, the study indicates the types of buildings that could be targeted in Demand Management programs for the mutual benefit of electricity networks and building occupants.
Resumo:
Abstract Ag-TiO2 and Au-TiO2 hybrid electrodes were designed by covalent attachment of TiO2 nanoparticles to Ag or Au electrodes via an organic linker. The optical and electronic properties of these systems were investigated using the cytochrome b5 (Cyt b5) domain of sulfite oxidase, exclusively attached to the TiO2 surface, as a Raman marker and model redox enzyme. Very strong SERR signals of Cyt b 5 were obtained for Ag-supported systems due to plasmonic field enhancement of Ag. Time-resolved surface-enhanced resonance Raman spectroscopic measurements yielded a remarkably fast electron transfer kinetic (k = 60 s -1) of Cyt b5 to Ag. A much lower Raman intensity was observed for Au-supported systems with undefined and slow redox behavior. We explain this phenomenon on the basis of the different potential of zero charge of the two metals that largely influence the electronic properties of the TiO2 island film. © 2013 American Chemical Society.
Resumo:
Background Few studies have examined acute injuries in track and field in both elite and sub-elite athletes. Purpose To observe the absolute and relative rates of injury in track and field athletes across a wide range of competition levels and ages during three years of the Penn Relays Carnival to assist with future medical coverage planning and injury prevention strategies. Study design: Descriptive epidemiology study. Methods Over a 3-year period all injuries treated by the medical staff were recorded on a standardised injury report form. Absolute injury rates (absolute number of injuries) and relative injury rates (number of injuries per 1000 participants) were determined and odds ratios (OR) of injury rates were calculated between sexes, competition levels and events. Injuries were also broken down into major or minor medical or orthopedic injuries. Results Throughout the study period 48,473 competing athletes participated in the Penn Relays Carnival, and 436 injuries were sustained. For medical coverage purposes, the relative rate of injury subtypes was greatest for minor orthopedic injuries (5.71 injuries per 1000 participants), followed by minor medical injuries (3.42 injuries per 1000 participants), major medical injuries (0.69 injuries per 1000 participants) and major orthopedic injuries (0.18 injuries per 1000 participants). College/elite level athletes displayed the lowest relative injury rate (7.99 injuries per 1000 participants), which was significantly less than high school (9.87 injuries per 1000 participants) and masters level athletes (16.33 injuries per 1000 participants). Males displayed a greater likelihood of suffering a minor orthopedic injury compared to females (OR = 1.36, 95% CI = 1.06 to 1.75; χ2 = 5.73, p = 0.017) but were less likely to sustain a major medical injury (OR = 0.33, 95% CI = 0.15 to 0.75; χ2 = 7.75, p = 0.005). Of the three most heavily participated in events, the 4 x 400m relay displayed the greatest relative injury rate (13.6 injuries per 1000 participants) compared to the 4 x 100 and 4 x 200m relay. Conclusions Medical coverage teams for future large scale track and field events need to plan for at least two major orthopedic and seven major medical injuries per 1000 participants. Male track and field athletes, particularly masters level male athletes, are at greater risk of injury compared to other genders and competition levels.