899 resultados para FEASIBILITY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We assessed the feasibility of obtaining probe microphone measurements of hearing aids at a distance. Face-to-face and remote probe microphone measurements were carried out in 60 hearing aid users (mean age 67 yrs) with uni- or bilateral hearing losses (105 ears tested). The participant and a facilitator were located in a room equipped with a probe microphone system interfaced to a PC. Desktop videoconferencing and application sharing was used to allow an audiologist in another room to instruct the facilitator and control the equipment via the LAN. There were significant correlations between face-to-face and remote real ear unaided response (REUR), aided response (REAR) and insertion gain (REIG) at seven discrete frequencies from 250 to 6000 Hz. Differences between face-to-face and remote responses were within the reported variability for probe microphone measurements themselves. The results show that remote probe microphone measurements are feasible and might improve the quality of public hearing aid services and professional training in Brazil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There are at present disparate published results with regard to the relevance of the Bcl-2 gene family, levels of apoptosis, and cell proliferation in the development and progression of renal cell carcinoma (RCC). The present study v analyses the interrelationship between the expression of representatives of the anti-apoptotic (Bcl-2, Bcl-X-L) or pro-apoptotic (Bax) Bcl-2 proteins, incidence of apoptosis, and mitosis in a selected small group of 22 graded RCCs that had paired normal renal tissue, or non-neoplastic tissue in the renal biopsy specimen. The cases were chosen to determine the feasibility of measuring these parameters as potential surrogate markers of progression or treatment failure of the cancers. The results showed that in approximately 50% of the RCCs, where Bcl-2 and/or Bcl-X-L expression was high, apoptosis it-as not detected, and when expression of these proteins was low or not found, increased levels of apoptosis were seen. In most of the remaining 50% of samples, high levels of Bcl-X-L but not Bcl-2 were negatively correlated with low levels of apoptosis (Bcl-X-L: r = -0.437, P = 0.07 and Bcl-2: r = + 0.560, P = 0.02). For the same group of samples, high Bax expression was found in association with apoptosis (r = + 0.578, P = 0,02). A novel finding was an association between low expression of Bcl-2 an/or Bcl-X-L in normal tissue and the level of expression of these proteins in the RCCs, an intrinsic variation that may be an individual patient factor. The results indicate that, in RCCs with increased expression of Bcl-2 and/or Bcl-X-L, levels of apoptosis are minimal and these combined factors may assist in progression of the cancers and resistance to treatments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the background and current status of an OMERACT facilitated effort to improve the consistency of adverse event reporting in rheumatology clinical trials, The overall goal is the development of an adverse event assessment tool that would provide a basis for use of common terminology and improve the consistency of reporting severity of side effects within rheumatology clinical trials and during postmarketing surveillance. The resulting Rheumatology Common Toxicity Criteria Index encompassed the following organ systems: allergic/immunologic, cardiac, ENT, gastrointestinal, musculoskeletal, neuropsychiatric, ophthalmologic, pulmonary and skin/integument. Before this tool is widely accepted, its validity, consistency, and feasibility need to be assessed in clinical trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective-To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients. Design-Cohort study. Setting-Regional cardiothoracic unit. Patients-49 patients (mean (SD) age 61 (11) years; 27 women, 22 men) with known or suspected coronary artery disease were studied with simultaneous myocardial contrast echo (MCE) and SPECT after standard dipyridamole stress. Main outcome measures-Regional myocardial perfusion by SPECT, performed with Tc-99m tetrafosmin, scored qualitatively and also quantitated as per cent maximum activity. Results-Normal perfusion was identified by SPECT in 225 of 270 segments (83%). Contrast echo images were interpretable in 92% of patients. The proportion of normal MCE by grey scale, subtracted, and power Doppler techniques were respectively 76%, 74%, and 88% (p < 0.05) at > 80% of maximum counts, compared with 65%, 69%, and 61% at < 60% of maximum counts. For each technique, specificity was lowest in the lateral wail, although power Doppler was the least affected. Grey scale and subtraction techniques were least accurate in the septal wall, but power Doppler showed particular problems in the apex. On a per patient analysis, the sensitivity was 67%, 75%, and 83% for detection of coronary artery disease using grey scale, colour coded, and power Doppler, respectively, with a significant difference between power Doppler and grey scale only (p < 0.05). Specificity was also the highest for power Doppler, at 55%, but not significantly different from subtracted colour coded images. Conclusions-Myocardial contrast echo using harmonic power Doppler has greater accuracy than with grey scale imaging and digital subtraction. However, power Doppler appears to be less sensitive for mild perfusion defects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow tagging technique based upon ionic fluorescence in strontium is investigated for applications to velocity measurements in gas flows. The method is based upon a combination of two laser based spectroscopic techniques, i.e. resonantly-enhanced ionisation and laser-induced ionic fluorescence. Strontium is first ionised and then planar laser-induced fluorescence is utilised to give 2D 'bright images' of the ionised region of the flow at a given time delay. The results show that this method can be used for velocity measurements. The velocities were measured in two types of air-acetylene flames - a slot burner and a circular burner yielding velocities of 5.1 +/- 0.1 m/s and 9.3 +/- 0.2 m/s, respectively. The feasibility of the method for the determination of velocities in faster flows than those investigated here is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the progress towards developing a patient rated toxicity index that meets all of the patient-important attributes defined by the OMERACT Drug Safety Working Party, These attributes are frequency, severity. importance to patient, importance to the clinician, impact on economics, impact on activities, and integration of adverse effects with benefits. The Stanford Toxicity Index (STI) has been revised to collect all attributes with the exception of impact on activities. However, since the STI is a part of the Health Assessment Questionnaire (HAQ). impact on activities is collected by the HAQ. In particular, a new question asks patients to rate overall satisfaction, taking into consideration both benefits and adverse effects. The nest step in the development of this tool is to ensure that the STI meets the OMERACT filter of truth, discrimination, and feasibility. Although truth and feasibility have been confirmed by comparisons within the ARAMIS database, discrimination needs to be assessed in clinical trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to investigate the effect of high-pass filtering on TEOAE obtained from 2-month-old infants as a function of filter cut-off frequency, activity states and pass/fail status of infants. Two experiments were performed. In Experiment 1, 100 2-month-old infants (200 ears) in five activity states (asleep, awake but peaceful, sucking a pacifier, feeding, restless) were tested by use of TEOAE technology. Five different filter conditions were applied to the TEOAE responses post hoc. The filter conditions were set at 781 Hz (default setting), 1.0, 1.2, 1.4 and 1.6 kHz. Results from this experiment showed that TEOAE parameters, such as whole-wave reproducibility (WR) and signal-to-noise ratio (SNR) at 0.8 kHz and 1.6 kHz, changed as a function of the cut-off frequency. The findings suggest that the 1.6 kHz and 1.2 kHz filter conditions are optimal for WR and SNR pass/fail criteria, respectively. Although all infant recordings appeared to benefit from the filtering, infants in the noisy states seemed to benefit the most. In Experiment 2, the high-pass filtering technique was applied to 23 infants (35 ears) who apparently failed the TEOAE tests on initial screening but were subsequently awarded a pass status based on the results from a follow-up auditory brainstem response (ABR) assessment. The findings showed a significant decrease in noise contamination of the TEOAE with a corresponding significant increase in WR. With high-pass filtering at 1.6 kHz, 21/35 ears could be reclassified into the pass category.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A feasibility study was carried out to test the hypothesis that, for an effective telehealth service, a full-time coordinator is required to act as a single point of contact for consultation requests. By shifting the responsibility for telepaediatrics from the referrer to the provider, the telehealth process becomes equally (or more) attractive as the conventional alternative. Preliminary results showed that, within six months, telepaediatric activity increased to an average of 8 h per month. Not only did certain health services become more accessible to children and their families in remote areas of Queensland, but significant savings were also made. At least 12 patient transfers were avoided to and from the tertiary facility, with an estimated minimum saving of $18,000 to the health-care provider.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pasminco Century Mine has developed a geophysical logging system to provide new data for ore mining/grade control and the generation of Short Term Models for mine planning. Previous work indicated the applicability of petrophysical logging for lithology prediction, however, the automation of the method was not considered reliable enough for the development of a mining model. A test survey was undertaken using two diamond drilled control holes and eight percussion holes. All holes were logged with natural gamma, magnetic susceptibility and density. Calibration of the LogTrans auto-interpretation software using only natural gamma and magnetic susceptibility indicated that both lithology and stratigraphy could be predicted. Development of a capability to enforce stratigraphic order within LogTrans increased the reliability and accuracy of interpretations. After the completion of a feasibility program, Century Mine has invested in a dedicated logging vehicle to log blast holes as well as for use in in-fill drilling programs. Future refinement of the system may lead to the development of GPS controlled excavators for mining ore.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research is part of a project whose scope was to investigate the engineering properties of new non-commercial alloy formulations based on the Cu rich corner of the Cu-Fe-Cr ternary system with the primary aim of exploring the development of a new cost-effective high-strength, high-conductivity copper alloy. The literature indicated that Cu rich Cu-Cr and Cu-Fe alloys have been thoroughly investigated. A number of commercial alloys have been developed and these are used for a variety of applications requiring combinations of high-strength, high-conductivity and resistance to softening. Little evidence was found in the literature that the Cu rich corner of the Cu-Fe-Cr system had previously been investigated for the purpose of developing high-strength, high-conductivity copper alloys resistant to softening. The aim of these present investigations was to explore the possibility that new alloys could be developed that combined the properties of both sets of alloys, ie large precipitation hardening response combined with the ability to stabilise cold worked microstructures to high temperatures while at the same maintain high electrical conductivity. To assess the feasibility of this goal the following alloys were chosen for investigation: Cu-0.7wt%Cr-0.3wt%Fe, Cu-0.7wt%Cr-0.8wt%Fe, Cu-0.7wt%Cr-2.0wt%Fe. This paper reports on the mechanical property investigation which indicated that the Cu-0.7wt%Cr-0.3wt%Fe, and Cu-0.7wt%Cr-2.0wt%Fe alloys were worthy of further investigation. (C) 2001 Kluwer Academic Publishers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. The MUC1 antigen can be used to identify epithelial cells from the background of hemopoietic cells. The present investigation describes patterns of overexpression of two novel MUC1 splice variants in human cervical carcinoma cell lines. Methods. RT-PCR was carried out to determine MUC1 splice variants in the cervical cancer cell lines C-4 II, C-33A, DoTc 2 4510, C-4 I, SiHa, HT3, Hs 636 T (C4-I), and HeLa. Results. The novel MUC1 splice variant D was expressed in all cell lines and the novel MUC1 splice variant C was expressed in all cell lines but C-33A. Variants A and B were expressed in all (variant A) and all but one (variant B) cell line. MUC1/REP was expressed in all cell lines and MUC1/SEC was positive in all but two cell lines (C-33 A, DoTc 2 4510). All but one cell line (C-33A) expressed MUC1/X and MUC1/Y, and two cell lines (C-33 A, DoTc 2 4510) did not express MUC1/Z, respectively. MUC1 variants A, D, and REP could be demonstrated consistently among all eight cervical carcinoma cell lines we have examined. Conclusions. The present study describes the feasibility of detecting a large number of MUC1 variants, including MUC1 variants C and D which are described for cervical carcinoma cells for the first time. Further studies will examine the presence of MUC1 splice variants' expression in human cervical carcinoma tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To examine the feasibility and safety of a low anterior resection of the rectosigmoid plus adjacent pelvic tumour as part of primary cytoreduction for ovarian cancer. Methods. This study included 65 consecutive patients with primary ovarian cancer who had debulking surgery from 1996 through 2000. All patients underwent an en bloc resection of ovarian cancer and a rectosigmoid resection followed by an end-to-end anastomosis. Parameters for safety and efficacy were considered as primary statistical endpoints for the aim of this analysis. Results. Postoperative residual tumour was nil, 1 cm in 14, 34, and 14 patients, respectively. The median postoperative hospital stay was 11 days (range, 6 to 50 days). Intraoperative complications included an injury to the urinary bladder in one patient. Postoperative complications included wound complications (n=14, 21.5%), septicemia (n=9, 13.8%), cardiac complications (n=7, 10.8%), thromboembolic complications (n=5, 7.7%) ileus (n=2, 3.1%) anastomotic leak (n=2, 3.1%) and fistula (n=1, 1.5%). Reasons for a reoperation during the same admission included repair of an anastomotic leak (n=1), postoperative hemorrhage (n=1), and wound debridement (n=1). Wound complications, septicemia, and anastomotic leak formation were more frequent in patients who had a serum albumin level of less than or equal to 30 g/L preoperatively. There was one surgically related mortality in a patient who died from a cerebral vascular accident 2 days postoperatively. Conclusions. An en bloc resection as part of primary cytoreductive surgery for ovarian cancer is effective and its morbidity is acceptably low. (C) 2001 Academic Press.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We are witnessing an enormous growth in biological nitrogen removal from wastewater. It presents specific challenges beyond traditional COD (carbon) removal. A possibility for optimised process design is the use of biomass-supporting media. In this paper, attached growth processes (AGP) are evaluated using dynamic simulations. The advantages of these systems that were qualitatively described elsewhere, are validated quantitatively based on a simulation benchmark for activated sludge treatment systems. This simulation benchmark is extended with a biofilm model that allows for fast and accurate simulation of the conversion of different substrates in a biofilm. The economic feasibility of this system is evaluated using the data generated with the benchmark simulations. Capital savings due to volume reduction and reduced sludge production are weighed out against increased aeration costs. In this evaluation, effluent quality is integrated as well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The present study aimed to investigate the feasibility and practicalities or testing children in special school settings using transient evoked otoacoustic emissions (TEOAE) and tympanometry. Children studying in special schools, particularly those with intellectual impairment, may be highly susceptible to hearing pathologies and can be difficult to assess using traditional test batteries. Researchers have recently suggested the possible applicability of TEOAE testing. in lieu of conventional behavioral methods, as a hearing screening device for persons with intellectual impairment. However, to date. few publications have detailed the particulars and results of such testing. Methods: A total of 489 children, with a mean age of 9.6 years, were tested in 15 special schools. Case information was obtained regarding birth history, medical history and type,degree of impairment, for later comparison with screening results. TEOAEs were collected using Quickscreen mode of the ILO292 Otodynamics Analyzer, whilst tympanometry was performed utilizing a Madsen Zodiac 901 Middle Ear Analyzer. Results: In total, 80% of students were able to be tested using TEOAEs. Average test time per ear was 2 min. However, a large proportion (40 of those able to be tested) failed TEOAE testing in at least one ear. No significant effects were found between could-not-test (CNT) cases and case history factors, A significant difference in TEOAE failure rates was found across history of neonatal special care nursery residency and history of parental concern regarding possible hearing impairment. Failure rates were higher for those who indicated positive histories. A total of 74% of subjects could be tested using tympanometry, with 25% of those able to be tested failing in at least one ear. Notably, neither type nor degree of impairment had any significant bearing on CNT or failure rates for tympanometry or TEOAE screening. Conclusions: Findings of the present investigation lend support to the review of hearing screening programs for children in special schools. with TEOAEs presenting as a potential alternative procedure. Further examination of the performance measures of protocols incorporating TEOAEs would now be advantageous. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.