903 resultados para Evaluation of performance


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The inherent analogue nature of medical ultrasound signals in conjunction with the abundant merits provided by digital image acquisition, together with the increasing use of relatively simple front-end circuitries, have created considerable demand for single-bit  beamformers in digital ultrasound imaging systems. Furthermore, the increasing need to design lightweight ultrasound systems with low power consumption and low noise, provide ample justification for development and innovation in the use of single-bit  beamformers in ultrasound imaging systems. The overall aim of this research program is to investigate, establish, develop and confirm through a combination of theoretical analysis and detailed simulations, that utilize raw phantom data sets, suitable techniques for the design of simple-to-implement hardware efficient  digital ultrasound beamformers to address the requirements for 3D scanners with large channel counts, as well as portable and lightweight ultrasound scanners for point-of-care applications and intravascular imaging systems. In addition, the stability boundaries of higher-order High-Pass (HP) and Band-Pass (BP) Σ−Δ modulators for single- and dual- sinusoidal inputs are determined using quasi-linear modeling together with the describing-function method, to more accurately model the  modulator quantizer. The theoretical results are shown to be in good agreement with the simulation results for a variety of input amplitudes, bandwidths, and modulator orders. The proposed mathematical models of the quantizer will immensely help speed up the design of higher order HP and BP Σ−Δ modulators to be applicable for digital ultrasound beamformers. Finally, a user friendly design and performance evaluation tool for LP, BP and HP  modulators is developed. This toolbox, which uses various design methodologies and covers an assortment of  modulators topologies, is intended to accelerate the design process and evaluation of  modulators. This design tool is further developed to enable the design, analysis and evaluation of  beamformer structures including the noise analyses of the final B-scan images. Thus, this tool will allow researchers and practitioners to design and verify different reconstruction filters and analyze the results directly on the B-scan ultrasound images thereby saving considerable time and effort.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Acute myeloid leukemia (AML) is a heterogeneous clonal disorder often associated with dismal overall survival. The clinical diversity of AML is reflected in the range of recurrent somatic mutations in several genes, many of which have a prognostic and therapeutic value. Targeted next-generation sequencing (NGS) of these genes has the potential for translation into clinical practice. In order to assess this potential, an inter-laboratory evaluation of a commercially available AML gene panel across three diagnostic centres in the UK and Ireland was performed.

METHODS: DNA from six AML patient samples was distributed to each centre and processed using a standardised workflow, including a common sequencing platform, sequencing chips and bioinformatics pipeline. A duplicate sample in each centre was run to assess inter- and intra-laboratory performance.

RESULTS: An average sample read depth of 2725X (range 629-5600) was achieved using six samples per chip, with some variability observed in the depth of coverage generated for individual samples and between centres. A total of 16 somatic mutations were detected in the six AML samples, with a mean of 2.7 mutations per sample (range 1-4) representing nine genes on the panel. 15/16 mutations were identified by all three centres. Allelic frequencies of the mutations ranged from 5.6 to 53.3 % (median 44.4 %), with a high level of concordance of these frequencies between centres, for mutations detected.

CONCLUSION: In this inter-laboratory comparison, a high concordance, reproducibility and robustness was demonstrated using a commercially available NGS AML gene panel and platform.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper strontium-site-deficient Sr2Fe1.4Co0.1Mo0.5O6-δ-based perovskite oxides (SxFCM) were prepared and evaluated as the cathode materials for intermediate temperature solid oxide fuel cells (IT-SOFCs). All samples exhibited a cubic phase structure and the lattice shrinked with increasing the Sr-deficiency as shown in XRD patterns. XPS results determined that the transition elements (Co/Fe/Mo) in SxFCM oxides were in a mixed valence state, demonstrating the small polaron hopping conductivity mechanism existed. Among the samples, S1.950FCM presented the lowest coefficient of thermal expansion of 15.62 × 10-6 K-1, the highest conductivity value of 28 S cm-1 at 500 °C, and the lowest interfacial polarization resistance of 0.093 Ω cm2 at 800 °C, respectively. Furthermore, an anode-supported single cell with a S1.950FCM cathode was prepared, demonstrating a maximum power density of 1.16 W cm-2 at 800 °C by using wet H2 (3% H2O) as the fuel and ambient air as the oxidant. These results indicate that the introduction of Sr-deficiency can dramatically improve the electrochemical performance of Sr2Fe1.4Co0.1Mo0.5O6-δ, showing great promise as a novel cathode candidate material for IT-SOFCs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work NiO/3mol% Y2O3-ZrO2 (3YSZ) and NiO/8mol% Y2O3-ZrO2 (8YSZ) hollow fibers were prepared by phase-inversion. The effect of different kinds of YSZ (3YSZ and 8YSZ) on the porosity, electrical conductivity, shrinkage and flexural strength of the hollow fibers were systematically evaluated. When compared with Ni-8YSZ the porosity and shrinkage of Ni-3YSZ hollow fibers increases while the electrical conductivity decreases, while at the same time also exhibiting enhanced flexural strength. Single cells with Ni-3YSZ and Ni-8YSZ hollow fibers as the supported anode were successfully fabricated showing maximum power densities of 0.53 and 0.67Wcm-2 at 800°C, respectively. Furthermore, in order to improve the cell performance, a Ni-8YSZ anode functional layer was added between the electrolyte and Ni-YSZ hollow fiber. Here enhanced peak power densities of 0.79 and 0.73Wcm-2 were achieved at 800°C for single cells with Ni-3YSZ and Ni-8YSZ hollow fibers, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The major objective of this research project is to investigate how fly ash influences the chemical durability of portland cement based materials. The testing program is evaluating how Iowa fly ashes influence the sulfate durability of portland cement-fly ash pastes, mortars, and concretes. Also, alkali-reactivity studies are being conducted on mortar bar specimens prepared in accordance with ASTM C 311. Prelimary sulfate test results, based only on mortar bar studies, indicate that only the very high-calcium fly ash (29 percent CaO, by weight) consistently reduced the durability of test specimens exposed to a solution containing 5 percent sodium sulfate. The remaining four fly ashes that were used in the study showed negligible to dramatic increases in sulfate resistance. Concrete specimens were only beginning to respond to the sulfate solutions after about one year of exposure; and hence, considerably more time will be needed to assess their performance. Preliminary results from the alkali-reactivity tests have indicated that the Oreopolis aggregate is not sensitive to alkali attack. However, some of the test results have indicated that the testing procedure may be prone to delayed expansion due to the presence of periclase (MgO) in the Class C fly ashes. Research is being planned to: (1) verify if the periclase is influencing test results; and (2) estimating the magnitude of the potential error.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Franchising is an important form of organizational control. Possible benefits of franchising include its ability to reduce agency costs that increase with costly monitoring, and provide incentives for the use of local information by onsite managers. However, these benefits may come at a cost, as franchisees may reduce quality by choosing to free ride. While many studies have investigated the reasons for franchising, few studies have documented the impacts of franchising on unit level operating performance. Using time-series data from a number of lodging properties that were converted to franchisee control from company control, this study documents the performance impacts of franchising. The analysis reveals that conversion results in a modest decline in financial performance and an immediate sharp decline in quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-08

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Interactive applications do not require more bandwidth to go faster. Instead, they require less latency. Unfortunately, the current design of transport protocols such as TCP limits possible latency reductions. In this paper we evaluate and compare different loss recovery enhancements to fight tail loss latency. The two recently proposed mechanisms "RTO Restart" (RTOR) and "Tail Loss Probe" (TLP) as well as a new mechanism that applies the logic of RTOR to the TLP timer management (TLPR) are considered. The results show that the relative performance of RTOR and TLP when tail loss occurs is scenario dependent, but with TLP having potentially larger gains. The TLPR mechanism reaps the benefits of both approaches and in most scenarios it shows the best performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Groundnut cake (GNC) meal is an important source of dietary protein for domestic animals with a cost advantage over the conventional animal protein sources used in aquaculture feed production. It would be useful to evaluate the effects of GNC processing methods on the density and nutritional values of processed GNC meals. The use of processed GNC meals in the diets of Clarias gariepinus fingerlings was evaluated. Seven iso-proteic and iso-caloric diets were formulated, replacing fish meal with roasted and boiled GNC meals, each at three inclusion levels of 30%, 35%, and 40%. Diet I is 100% fishmeal, Diet II is 30% roasted GNC meal, Diet III is 35% roasted GNC meal, Diet IV is 40% roasted GNC meal, Diet V is 30% boiled GNC meal, Diet VI is 35% boiled GNC meal and Diet VII is 40% boiled GNC meal. Results showed that the crude protein content of GNC meals was 40.5% and 40.8% in boiled and roasted GNC meals respectively; the lower protein content for processed GNC meals might be due to heat denaturation of the seed protein, with boiled GNC meal being more adversely affected. The mean weight gain of fingerlings fed roasted GNC meals ranged between 5.29 – 5.64 while for boiled GNC meals, it was between 4.60 – 5.22. Generally, fish performed better when fed diets containing roasted GNC meals, than boiled GNC meals, and compared favorably with fish fed fish meal based diet. Body mass increase, total feed increase, protein efficiency ratio and specific growth rate by C. gariepinus fingerlings in all diets, showed no significant differences, suggesting that processed GNC meals could partially replace diets for C. gariepinus fingerlings without adverse consequences. This study showed that processed GNC meals could partially replace fish meal up to 30% without significantly influencing fingerling growth and health. It is recommended that the use of fish meal as the main basal ingredient for fingerlings could be discontinued, since GNC meal was a cheaper alternative, and could replace fish meal up to 35%, without any significant adverse effects on the fingerling performance. KEYWORDS: Clarias gariepinus, Fingerlings, Groundnut cake meal, Nutrient utilization, Performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The recently developed network-wide real-time signal control strategy TUC has been implemented in three traffic networks with quite different traffic and control infrastructure characteristics: Chania, Greece (23 junctions); Southampton, UK (53 junctions); and Munich, Germany (25 junctions), where it has been compared to the respective resident real-time signal control strategies TASS, SCOOT and BALANCE. After a short outline of TUC, the paper describes the three application networks; the application, demonstration and evaluation conditions; as well as the comparative evaluation results. The main conclusions drawn from this high-effort inter-European undertaking is that TUC is an easy-to-implement, inter-operable, low-cost real-time signal control strategy whose performance, after very limited fine-tuning, proved to be better or, at least, similar to the ones achieved by long-standing strategies that were in most cases very well fine-tuned over the years in the specific networks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes how the recently developed network-wide real-time signal control strategy TUC has been implemented in three traffic networks with quite different traffic and control infrastructure characteristics: Chania, Greece (23 junctions); Southampton, U.K. (53 junctions); and Munich, Germany (25 junctions), where it has been compared to the respective resident real-time signal control strategies TASS, SCOOT and BALANCE. After a short outline of TUC, the paper describes the three application networks; the application, demonstration and evaluation conditions; as well as the comparative evaluation results. The main conclusions drawn from this high-effort inter-European undertaking is that TUC is an easy-to-implement, inter-operable, low-cost real-time signal control strategy whose performance, after limited fine-tuning, proved to be better or, at least, similar to the ones achieved by long-standing strategies that were in most cases very well fine-tuned over the years in the specific networks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The PhD project addresses the potential of using concentrating solar power (CSP) plants as a viable alternative energy producing system in Libya. Exergetic, energetic, economic and environmental analyses are carried out for a particular type of CSP plants. The study, although it aims a particular type of CSP plant – 50 MW parabolic trough-CSP plant, it is sufficiently general to be applied to other configurations. The novelty of the study, in addition to modeling and analyzing the selected configuration, lies in the use of a state-of-the-art exergetic analysis combined with the Life Cycle Assessment (LCA). The modeling and simulation of the plant is carried out in chapter three and they are conducted into two parts, namely: power cycle and solar field. The computer model developed for the analysis of the plant is based on algebraic equations describing the power cycle and the solar field. The model was solved using the Engineering Equation Solver (EES) software; and is designed to define the properties at each state point of the plant and then, sequentially, to determine energy, efficiency and irreversibility for each component. The developed model has the potential of using in the preliminary design of CSPs and, in particular, for the configuration of the solar field based on existing commercial plants. Moreover, it has the ability of analyzing the energetic, economic and environmental feasibility of using CSPs in different regions of the world, which is illustrated for the Libyan region in this study. The overall feasibility scenario is completed through an hourly analysis on an annual basis in chapter Four. This analysis allows the comparison of different systems and, eventually, a particular selection, and it includes both the economic and energetic components using the “greenius” software. The analysis also examined the impact of project financing and incentives on the cost of energy. The main technological finding of this analysis is higher performance and lower levelized cost of electricity (LCE) for Libya as compared to Southern Europe (Spain). Therefore, Libya has the potential of becoming attractive for the establishment of CSPs in its territory and, in this way, to facilitate the target of several European initiatives that aim to import electricity generated by renewable sources from North African and Middle East countries. The analysis is presented a brief review of the current cost of energy and the potential of reducing the cost from parabolic trough- CSP plant. Exergetic and environmental life cycle assessment analyses are conducted for the selected plant in chapter Five; the objectives are 1) to assess the environmental impact and cost, in terms of exergy of the life cycle of the plant; 2) to find out the points of weakness in terms of irreversibility of the process; and 3) to verify whether solar power plants can reduce environmental impact and the cost of electricity generation by comparing them with fossil fuel plants, in particular, Natural Gas Combined Cycle (NGCC) plant and oil thermal power plant. The analysis also targets a thermoeconomic analysis using the specific exergy costing (SPECO) method to evaluate the level of the cost caused by exergy destruction. The main technological findings are that the most important contribution impact lies with the solar field, which reports a value of 79%; and the materials with the vi highest impact are: steel (47%), molten salt (25%) and synthetic oil (21%). The “Human Health” damage category presents the highest impact (69%) followed by the “Resource” damage category (24%). In addition, the highest exergy demand is linked to the steel (47%); and there is a considerable exergetic demand related to the molten salt and synthetic oil with values of 25% and 19%, respectively. Finally, in the comparison with fossil fuel power plants (NGCC and Oil), the CSP plant presents the lowest environmental impact, while the worst environmental performance is reported to the oil power plant followed by NGCC plant. The solar field presents the largest value of cost rate, where the boiler is a component with the highest cost rate among the power cycle components. The thermal storage allows the CSP plants to overcome solar irradiation transients, to respond to electricity demand independent of weather conditions, and to extend electricity production beyond the availability of daylight. Numerical analysis of the thermal transient response of a thermocline storage tank is carried out for the charging phase. The system of equations describing the numerical model is solved by using time-implicit and space-backward finite differences and which encoded within the Matlab environment. The analysis presented the following findings: the predictions agree well with the experiments for the time evolution of the thermocline region, particularly for the regions away from the top-inlet. The deviations observed in the near-region of the inlet are most likely due to the high-level of turbulence in this region due to the localized level of mixing resulting; a simple analytical model to take into consideration this increased turbulence level was developed and it leads to some improvement of the predictions; this approach requires practically no additional computational effort and it relates the effective thermal diffusivity to the mean effective velocity of the fluid at each particular height of the system. Altogether the study indicates that the selected parabolic trough-CSP plant has the edge over alternative competing technologies for locations where DNI is high and where land usage is not an issue, such as the shoreline of Libya.