975 resultados para Electroencephalogram(ECG)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this work was to evaluate the electrocardiography effects (ECG), sedation time and quality of recovery due to buprenorphine (G1) and butorphanol (G2) administration in dogs pretreated with acepromazine. Seven adult dogs were submitted to both protocols, with a thirty days interval between groups. G1 animals were premedicated with acepromazine (0.1 mg/kg) followed 10 minutes later with buprenorphine (0.005 mg/kg), both applied intravenously. The same procedure was performed for G2 employing butorphanol (0.3 mg/kg) instead of buprenorphine. The measurements of the variables heart rate (HR), duration and amplitude of P wave, P-R intervals (PR), QRS complex duration, R wave amplitude, Q-T intervals (QT) and R-R intervals (RR) were taken immediately before application of acepromazine (M0), 10 minute after administration of acepromazine (M10) and 10 minutes after opioids administration (M20). Serial measurements were carried out in 10 minute intervals after the administration of butorphanol or buprenorphine up to 60 minutes. Numeric data were submitted to Tukey Analysis (p < 0.05). The amplitude of P wave decreased 30 minutes after the administration of the butorphanol. Sedation time was longer in G1 (78 minutes) than G2 (72 minutes) and recovery was good in both groups. These results indicate that butorphanol or buprenorphine produced discreet alterations on ECG, which don´t contraindicate its clinical use.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The electrocardiogram (ECG) is an important tool used in the diagnosis of cardiac arrhythmias, since it gives the graphic representation of depolarization and repolarization processes of the cardiac muscle. This study allows recording the electrical activity of myocardial cells and the underlying differences in electric potential: the magnitude of this difference is measured in millivolts (mV), and its duration is measured in seconds. The ECG is indicated when an irregular rhythm is detected during physical examination, such as bradycardias, tachycardias or arrhythmias that are not secondary to breathing, in animals with a history of syncope or weakness, for monitoring the effectiveness of antiarrhythmic therapy, in cases of putative pleural or pericardial effusion, and also in systemic diseases that lead to arrhythmia. For a reliable assessment, the ECG must be evaluated in conjunction with findings from the physical examination and clinical signs of each patient.
Resumo:
Many peptides are responsible for the coordination of muscle contraction, secretion and ciliary beating of the oviduct epithelium to allow the transport of gametes and embryos, including vascular endothelial growth factors (VEGF), prostaglandins (PGs), endotelin-1 (ET-1) andangiotensinII(Ang II). The effect of reproductive biotechnologiesusedto improve embryo yield on oviduct gene expression is poorly understood. Thus, the aim of the present study was to evaluate the effect of ovarian superstimulation on the mRNA expression of the genes encoding the major peptides involved in oviduct contraction in bovine. Therefore, Nelore cows were submitted to P-36 (n = 5) or P-36/eCG (n = 5) ovarian superstimulatory protocols and a control group of cows was not submitted to any superstimulatory protocol (n = 5). The relative expression of VEGF (VEGF, Flk1, Flt1), Ang II (AGTR2, ACE1), ET1 (ET1, ECE1) and PG pathway members (PGES, EP2, EP4, COX1, COX2) was analyzed using real time RT-PCR in each of oviduct segment (infundibulum, ampulla and isthmus). All target genes were expressed in the three segments of the bovine oviduct; however, specific genes were regulated by ovarian superstimulation: EP2 and EP4 receptors mRNA was affected by P- 36/eCG protocol, in the ampulla and infundibulum, respectively; and AGTR2 mRNA was up-regulated by both the P-36/eCG and P-36 protocols in the isthmus. The upregulation of EP2, EP4 and AGTR2 expression in the superstimulated cows suggests a suitable effect of FSH and eCG on bovine oviduct physiology, coordinating the contraction in Nelore cows
Resumo:
This work aimed to evaluate the influence of postpartum period (precocious - of 28 to 44 days and late - of 45 to 90 days) on the bovine pregnancy rate using fixed-time AI. For that, 678 cows were divided in two groups: precocious group (G-P, n=151) and late group (G-T, n=527). The animals received CIDR® + 2 mL of estradiol benzoate (BE) in the day zero (D0). After eight days (D8) the dispositive was removed and both groups received 2.5mL PGF2α, concurrent with PGF2α injection, they received either 1.5mL of eCG or temporary calf removal (RTB). In the next day (D9), the cows received 1 mL de BE and 24 hours later, the fixed-time AI was performed with Nelore bovine semen. The calves were returned to their mothers. The pregnancy rate was not different between the groups (p>0.05), G-P=40% and G-T=48%. The results indicate that females with less than 45 days of postpartum are able to hormone protocol of fixed-time IA.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: The use of noninvasive cortical electrical stimulation with weak currents has significantly increased in basic and clinical human studies. Initial, preliminary studies with this technique have shown encouraging results; however, the safety and tolerability of this method of brain stimulation have not been sufficiently explored yet. The purpose of our study was to assess the effects of direct current (DC) and alternating current (AC) stimulation at different intensities in order to measure their effects on cognition, mood, and electroencephalogram. Methods: Eighty-two healthy, right-handed subjects received active and sham stimulation in a randomized order. We conducted 164 ninety-minute sessions of electrical stimulation in 4 different protocols to assess safety of (1) anodal DC of the dorsolateral prefrontal cortex (DLPFC); (2) cathodal DC of the DLPFC; (3) intermittent anodal DC of the DLPFC and; (4) AC on the zygomatic process. We used weak currents of 1 to 2 mA (for DC experiments) or 0.1 to 0.2 mA (for AC experiment). Results: We found no significant changes in electroencephalogram, cognition, mood, and pain between groups and a low prevalence of mild adverse effects (0.11% and 0.08% in the active and sham stimulation groups, respectively), mainly, sleepiness and mild headache that were equally distributed between groups. Conclusions: Here, we show no neurophysiological or behavioral signs that transcranial DC stimulation or AC stimulation with weak currents induce deleterious changes when comparing active and sham groups. This study provides therefore additional information for researchers and ethics committees, adding important results to the safety pool of studies assessing the effects of cortical stimulation using weak electrical currents. Further studies in patients with neuropsychiatric disorders are warranted.
Resumo:
Objective: To ascertain incidence and predictors of new permanent pacemaker (PPM) following transcatheter aortic valve implantation (TAVI) with the self-expanding aortic bioprosthesis. Background: TAVI with the Medtronic Corevalve (MCV) Revalving System (Medtronic, Minneapolis, MN) has been associated with important post-procedural conduction abnormalities and frequent need for PPM. Methods: Overall, 73 consecutive patients with severe symptomatic AS underwent TAVI with the MCV at two institutions; 10 patients with previous pacemaker and 3 patients with previous aortic valve replacement were excluded for this analysis. Clinical, echocardiographic, and procedural data were collected prospectively in a dedicated database. A standard 12-lead ECG was recorded in all patients at baseline, after the procedure and predischarge. Decision to implant PPM was taken according to current guidelines. Logistic multivariable modeling was applied to identify independent predictors of PPM at discharge. Results: Patients exhibited high-risk features as evidenced by advanced age (mean = 82.1 +/- 6.2 years) and high surgical scores (logistic EuroSCORE 23.0 +/- 12.8%, STS score 9.4 +/- 6.9%). The incidence of new PPM was 28.3%. Interventricular septum thickness and logistic Euroscore were the baseline independent predictors of PPM. When procedural variables were included, the independent predictors of PPM were interventricular septum thickness (OR 0.52; 95% CI 0.320.85) and the distance between noncoronary cusp and the distal edge of the prosthesis (OR 1.37; 95% CI 1.031.83). Conclusions: Conduction abnormalities are frequently observed after TAVI with self-expandable bioprosthesis and definitive pacing is required in about a third of the patients, with a clear association with depth of implant and small interventricular septum thickness. (c) 2011 Wiley Periodicals, Inc.