924 resultados para Edge coupled SRR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the transport of heat along a chain of particles interacting through anharmonic potentials consisting of quartic terms in addition to harmonic quadratic terms and subject to heat reservoirs at its ends. Each particle is also subject to an impulsive shot noise with exponentially distributed waiting times whose effect is to change the sign of its velocity, thus conserving the energy of the chain. We show that the introduction of this energy conserving stochastic noise leads to Fourier's law. That is for large system size L the heat current J behaves as J ‘approximately’ 1/L, which amounts to say that the conductivity k is constant. The conductivity is related to the current by J = kΔT/L, where ΔT is the difference in the temperatures of the reservoirs. The behavior of heat conductivity k for small intensities¸ of the shot noise and large system sizes L are obtained by assuming a scaling behavior of the type k = ‘L POT a Psi’(L’lambda POT a/b’) where a and b are scaling exponents. For the pure harmonic case a = b = 1, characterizing a ballistic conduction of heat when the shot noise is absent. For the anharmonic case we found values for the exponents a and b smaller then 1 and thus consistent with a superdiffusive conduction of heat without the shot noise. We also show that the heat conductivity is not constant but is an increasing function of temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid, sensitive and specific method for quantifying hydroxocobalamin in human plasma using paracetamol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethanol 100%; -20°C). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed on Prevail C8 3 μm, analytical column (2.1×100 mm i.d.). The method had a chromatographic run time of 3.4 min and a linear calibration curve over the range 5-400 ng.mL-1 (r>0.9983). The limit of quantification was 5 ng.mL-1. The method was also validated without the use of the internal standard. The precision in the intra-batch validation with IS was 9.6%, 8.9%, 1.0% and 2.8% whereas without IS was 9.2%, 8.2%, 1.8% and 1.5% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in intra-batch validation with IS was 108.9%, 99.9%, 98.9% and 99.0% whereas without IS was 101.1%, 99.3%, 97.5% and 92.5% for 5, 15, 80 and 320 ng/mL, respectively. The precision in the inter-batch validation with IS was 9.4%, 6.9%, 4.6% and 5.5% whereas without IS was 10.9%, 6.4%, 5.0% and 6.2% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in inter-batch validation with IS was 101.9%, 104.1%, 103.2% and 99.7% whereas without IS was 94.4%, 101.2%, 101.6% and 96.0% for 5, 15, 80 and 320 ng/mL, respectively. This HPLC-MS-MS procedure was used to assess the pharmacokinetics of Hydroxo cobalamin following intramuscular injection 5000 μg in healthy volunteers of both sexes (10 males and 10 females). The volunteers had the following clinical characteristics (according to gender and expressed as mean ± SD [range]): males: age: 32.40 ± 8.00 y [23.00-46.00], height: 1.73 ± 0.07 m [1.62-1.85], body weight: 72.48 ± 10.22 Kg [60.20- 88.00]; females: age: 28.60 ± 9.54 y [18.00-44.00], height: 1.60 ± 0.05 m [1.54-1.70], body weight: 58.64 ± 6.09 Kg [51.70- 66.70]. The following pharmacokinetic parameters were obtained from the hydroxocobalamin plasma concentration vs. time curves: AUClast, T1/2, Tmax, Vd, Cl, Cmax and Clast. The pharmacokinetic parameters were 120 (± 25) ng/mL for Cmax, 2044 (± 641) ng.h/mL for AUClast, 8 (± 3.2) ng.mL-1 for Clast, 38 (± 15.8) hr for T1/2 and 2.5 (range 1-6) hr for Tmax. Female volunteers presented significant (p=0.0136) lower AUC (1706 ± 704) ng.h/mL) and larger (p=0.0205) clearance (2.91 ± 1.41 L/hr), as compared to male 2383 ± 343 ng.h/mL and 1.76 ± 0.23 L/hr, respectively. These pharmacokinetic differences could explain the higher prevalence of vitamin B12 deficiency in female patients. The method described validated well without the use of the internal standard and this approach should be investigated in other HPLC-MS-MS methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present paper, we solve a twist symplectic map for the action of an ergodic magnetic limiter in a large aspect-ratio tokamak. In this model, we study the bifurcation scenarios that occur in the remnants regular islands that co-exist with chaotic magnetic surfaces. The onset of atypical local bifurcations created by secondary shearless tori are identified through numerical profiles of internal rotation number and we observe that their rupture can reduce the usual magnetic field line escape at the tokamak plasma edge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ordered mesoporous ZrO2-CeO2 mixed oxides are potential candidates for catalytic applications. These systems, used as anodes in solid oxide fuel cells (SOFC), may lead to better performance of SOFCs, due to an enhancement on surface area, aiming to achieve a lower working temperature. The aim of this studies is to evaluate the reduction capacity of Ni2+ to Ni in ZrO2-x(mol)%CeO2 (x=50 and 90) samples impregnated with 60(wt.)%NiO. The synthesis was made with Zr and Ce chloride precursors, HCl aqueous solution, Pluronic P123, NH4OH to adjust the pH (3-4) and a teflon autoclave to perform a hydrothermal treatment (80oC/48h). The samples were dried and calcined, until 540oC in N2 and 4 hours in air. The NiO impregnation was made with an ethanol dispersion of Ni(NO3)£6H2O. The powder was calcinated in air until 350oC for 2 hours. Temperature-resolved XANES data at the Ni K-edge were collected at the DXAS beam line of the LNLS in transmission mode, using a Si(111) monochromator and a CCD detector. Sample preparation consisted of mixing »6mg of the powder samples with boron nitride and pressing into pellets. The data were acquired during an experiment of temperature programmed reduction (TPR) under a 5% H2/He until 600oC and mixtures of 20%CH4:5%O2/He, at temperatures from 400 to 600oC. All the reactions were monitored with a mass spectrometer. The data was analyzed with a linear combination fit of 2 standards for each valence number using Athena software. The Ni K-edge experiments demonstrated that for both contents of CeO2, NiO embedded in the porous zirconia-ceria matrix reduces at lower temperatures than pure NiO, revealing that the ZrO2-CeO2 support improves the reduction of impregnated NiO. Ni was oxidized to NiO after all reactions with methane and oxygen. Hydrogenated carbonaceous species were detected, but under reducing conditions, the hydrocarbon compounds are removed. The reaction of total oxidation of methane CH4:O2 (1:2 ratio) was observed at lower temperatures (around 400oC) for both samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Excitonic dynamics in a hybrid dot-well system composed of InAs quantum dots (QDs) and an InGaAs quantum well (QW) is studied by means of femtosecond pump-probe reflection and continuous wave (cw) photoluminescence (PL) spectroscopy. The system is engineered to bring the QW ground exciton state into resonance with the third QD excited state. The resonant tunneling rate is varied by changing the effective barrier thickness between the QD and QW layers. This strongly affects the exciton dynamics in these hybrid structures as compared to isolated QW or QD systems. Optically measured decay times of the coupled system demonstrate dramatically different response to temperature change depending on the strength of the resonant tunneling or coupling strength. This reflects a competition between purely quantum mechanical and thermodynamical processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] The aortic dissection is a disease that can cause a deadly situation, even with a correct treatment. It consists in a rupture of a layer of the aortic artery wall, causing a blood flow inside this rupture, called dissection. The aim of this paper is to contribute to its diagnosis, detecting the dissection edges inside the aorta. A subpixel accuracy edge detector based on the hypothesis of partial volume effect is used, where the intensity of an edge pixel is the sum of the contribution of each color weighted by its relative area inside the pixel. The method uses a floating window centred on the edge pixel and computes the edge features. The accuracy of our method is evaluated on synthetic images of different hickness and noise levels, obtaining an edge detection with a maximal mean error lower than 16 percent of a pixel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN]Until recently, sample preparation was carried out using traditional techniques, such as liquid–liquid extraction (LLE), that use large volumes of organic solvents. Solid-phase extraction (SPE) uses much less solvent than LLE, although the volume can still be significant. These preparation methods are expensive, time-consuming and environmentally unfriendly. Recently, a great effort has been made to develop new analytical methodologies able to perform direct analyses using miniaturised equipment, thereby achieving high enrichment factors, minimising solvent consumption and reducing waste. These microextraction techniques improve the performance during sample preparation, particularly in complex water environmental samples, such as wastewaters, surface and ground waters, tap waters, sea and river waters. Liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS) and time-of-flight mass spectrometric (TOF/MS) techniques can be used when analysing a broad range of organic micropollutants. Before separating and detecting these compounds in environmental samples, the target analytes must be extracted and pre-concentrated to make them detectable. In this work, we review the most recent applications of microextraction preparation techniques in different water environmental matrices to determine organic micropollutants: solid-phase microextraction SPME, in-tube solid-phase microextraction (IT-SPME), stir bar sorptive extraction (SBSE) and liquid-phase microextraction (LPME). Several groups of compounds are considered organic micropollutants because these are being released continuously into the environment. Many of these compounds are considered emerging contaminants. These analytes are generally compounds that are not covered by the existing regulations and are now detected more frequently in different environmental compartments. Pharmaceuticals, surfactants, personal care products and other chemicals are considered micropollutants. These compounds must be monitored because, although they are detected in low concentrations, they might be harmful toward ecosystems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] This paper presents a Boundary Elements (BE) approach for the efficiency improvement of road acoustic barriers, mora specifically, for the shape design optimization of top-edge devices in the search for the best designs in terms of screening performance, usually represented by the insertion loss (IL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN]The aim of this work is looking into the possibility of capturing the change in the modal properties (natural frequencies, modal shapes and modal damping ratio) of plain concrete elements due to the presence of cracked areas by using a simple continuum damage zone numerical model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several MCAO systems are under study to improve the angular resolution of the current and of the future generation large ground-based telescopes (diameters in the 8-40 m range). The subject of this PhD Thesis is embedded in this context. Two MCAO systems, in dierent realization phases, are addressed in this Thesis: NIRVANA, the 'double' MCAO system designed for one of the interferometric instruments of LBT, is in the integration and testing phase; MAORY, the future E-ELT MCAO module, is under preliminary study. These two systems takle the sky coverage problem in two dierent ways. The layer oriented approach of NIRVANA, coupled with multi-pyramids wavefront sensors, takes advantage of the optical co-addition of the signal coming from up to 12 NGS in a annular 2' to 6' technical FoV and up to 8 in the central 2' FoV. Summing the light coming from many natural sources permits to increase the limiting magnitude of the single NGS and to improve considerably the sky coverage. One of the two Wavefront Sensors for the mid- high altitude atmosphere analysis has been integrated and tested as a stand- alone unit in the laboratory at INAF-Osservatorio Astronomico di Bologna and afterwards delivered to the MPIA laboratories in Heidelberg, where was integrated and aligned to the post-focal optical relay of one LINC-NIRVANA arm. A number of tests were performed in order to characterize and optimize the system functionalities and performance. A report about this work is presented in Chapter 2. In the MAORY case, to ensure correction uniformity and sky coverage, the LGS-based approach is the current baseline. However, since the Sodium layer is approximately 10 km thick, the articial reference source looks elongated, especially when observed from the edge of a large aperture. On a 30-40 m class telescope, for instance, the maximum elongation varies between few arcsec and 10 arcsec, depending on the actual telescope diameter, on the Sodium layer properties and on the laser launcher position. The centroiding error in a Shack-Hartmann WFS increases proportionally to the elongation (in a photon noise dominated regime), strongly limiting the performance. To compensate for this effect a straightforward solution is to increase the laser power, i.e. to increase the number of detected photons per subaperture. The scope of Chapter 3 is twofold: an analysis of the performance of three dierent algorithms (Weighted Center of Gravity, Correlation and Quad-cell) for the instantaneous LGS image position measurement in presence of elongated spots and the determination of the required number of photons to achieve a certain average wavefront error over the telescope aperture. An alternative optical solution to the spot elongation problem is proposed in Section 3.4. Starting from the considerations presented in Chapter 3, a first order analysis of the LGS WFS for MAORY (number of subapertures, number of detected photons per subaperture, RON, focal plane sampling, subaperture FoV) is the subject of Chapter 4. An LGS WFS laboratory prototype was designed to reproduce the relevant aspects of an LGS SH WFS for the E-ELT and to evaluate the performance of different centroid algorithms in presence of elongated spots as investigated numerically and analytically in Chapter 3. This prototype permits to simulate realistic Sodium proles. A full testing plan for the prototype is set in Chapter 4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The last decades have seen a large effort of the scientific community to study and understand the physics of sea ice. We currently have a wide - even though still not exhaustive - knowledge of the sea ice dynamics and thermodynamics and of their temporal and spatial variability. Sea ice biogeochemistry is instead largely unknown. Sea ice algae production may account for up to 25% of overall primary production in ice-covered waters of the Southern Ocean. However, the influence of physical factors, such as the location of ice formation, the role of snow cover and light availability on sea ice primary production is poorly understood. There are only sparse localized observations and little knowledge of the functioning of sea ice biogeochemistry at larger scales. Modelling becomes then an auxiliary tool to help qualifying and quantifying the role of sea ice biogeochemistry in the ocean dynamics. In this thesis, a novel approach is used for the modelling and coupling of sea ice biogeochemistry - and in particular its primary production - to sea ice physics. Previous attempts were based on the coupling of rather complex sea ice physical models to empirical or relatively simple biological or biogeochemical models. The focus is moved here to a more biologically-oriented point of view. A simple, however comprehensive, physical model of the sea ice thermodynamics (ESIM) was developed and coupled to a novel sea ice implementation (BFM-SI) of the Biogeochemical Flux Model (BFM). The BFM is a comprehensive model, largely used and validated in the open ocean environment and in regional seas. The physical model has been developed having in mind the biogeochemical properties of sea ice and the physical inputs required to model sea ice biogeochemistry. The central concept of the coupling is the modelling of the Biologically-Active-Layer (BAL), which is the time-varying fraction of sea ice that is continuously connected to the ocean via brines pockets and channels and it acts as rich habitat for many microorganisms. The physical model provides the key physical properties of the BAL (e.g., brines volume, temperature and salinity), and the BFM-SI simulates the physiological and ecological response of the biological community to the physical enviroment. The new biogeochemical model is also coupled to the pelagic BFM through the exchange of organic and inorganic matter at the boundaries between the two systems . This is done by computing the entrapment of matter and gases when sea ice grows and release to the ocean when sea ice melts to ensure mass conservation. The model was tested in different ice-covered regions of the world ocean to test the generality of the parameterizations. The focus was particularly on the regions of landfast ice, where primary production is generally large. The implementation of the BFM in sea ice and the coupling structure in General Circulation Models will add a new component to the latters (and in general to Earth System Models), which will be able to provide adequate estimate of the role and importance of sea ice biogeochemistry in the global carbon cycle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coupled-Cluster-Berechnungen von Parametern derKernspin-Resonanz-Spektroskopie Dissertationsschrift von Alexander A.Auer, Mainz 2002 Im Rahmen einer Studie der Berechnung von 13C-Verschiebungenwerdendie Einfluesse von Elektronenkorrelation, Basissatz,Gleichgewichtsgeometrie sowie Schwingungs- und Rotationseffekten separat betrachtet.Dabei zeigt sich, dass dieCoupled-Cluster-Singles-Doubles-Methode mitstoerungstheoretischer Behandlung der Dreifachanregungen(CCSD(T)) mit entsprechend grossen Basissaetzen bei Beruecksichtigung derNullpunktsschwingungseffekte Ergebnisse mit ca. 1 ppm Abweichung zum Experiment liefert. Eine Analyse der Elektronenkorrelationseffekte beiCoupled-Cluster- (CC-) Berechnungen von indirekten Spin-Spin-Kopplungskonstanten zeigt, dassCC-Methoden mit Hartree-Fock-Orbitalrelaxation zur Berechnung derKopplungskonstanten ungeeignet sind. Eine Loesung ist die Verwendung unrelaxierter CC-Methoden,in denendie HF-Orbitalrelaxation aus der Berechnung der gestoertenWellenfunktion ausgeschlossen wird. Full-Configuration-Interaction-Berechnungen fuer Borhydridzeigen,dass auf CC-Singles-Doubles-Niveau (CCSD) 94% und aufCC-Singles-Doubles-Triples-Niveau (CCSDT) 99% der Korrelationseffekte beschrieben werden. Weiterhin istdie Beruecksichtigung der Nullpunktsschwingung sowie die Wahl eines ausreichend grossen Basissatzes wichtig. Auf Grundlage der vorangegangenen Studien werden im letztenTeil zwei Beispiele zur Anwendung hochgenauer Berechnungen vonNMR-Parametern vorgestellt.Im Rahmen einer Studie der Spin-Spin-Kopplungskonstanten vonCyclopentan wird eine Karplus-Beziehungzwischen den Kopplungskonstanten und der Konformation desMolekuels aufgestellt, desweiteren werden die NMR-Parameter von Methylidinphosphanuntersucht.