965 resultados para Descending toracic aorta
Resumo:
To study the role of early energetic abnormalities in the subsequent development of heart failure, we performed serial in vivo combined magnetic resonance imaging (MRI) and (31)P magnetic resonance spectroscopy (MRS) studies in mice that underwent pressure-overload following transverse aorta constriction (TAC). After 3 wk of TAC, a significant increase in left ventricular (LV) mass (74 +/- 4 vs. 140 +/- 26 mg, control vs. TAC, respectively; P < 0.000005), size [end-diastolic volume (EDV): 48 +/- 3 vs. 61 +/- 8 microl; P < 0.005], and contractile dysfunction [ejection fraction (EF): 62 +/- 4 vs. 38 +/- 10%; P < 0.000005] was observed, as well as depressed cardiac energetics (PCr/ATP: 2.0 +/- 0.1 vs. 1.3 +/- 0.4, P < 0.0005) measured by combined MRI/MRS. After an additional 3 wk, LV mass (140 +/- 26 vs. 167 +/- 36 mg; P < 0.01) and cavity size (EDV: 61 +/- 8 vs. 76 +/- 8 microl; P < 0.001) increased further, but there was no additional decline in PCr/ATP or EF. Cardiac PCr/ATP correlated inversely with end-systolic volume and directly with EF at 6 wk but not at 3 wk, suggesting a role of sustained energetic abnormalities in evolving chamber dysfunction and remodeling. Indeed, reduced cardiac PCr/ATP observed at 3 wk strongly correlated with changes in EDV that developed over the ensuing 3 wk. These data suggest that abnormal energetics due to pressure overload predict subsequent LV remodeling and dysfunction.
Resumo:
Connexins (Cxs) and endothelial nitric oxide synthase (eNOS) contribute to the adaptation of endothelial and smooth muscle cells to hemodynamic changes. To decipher the in vivo interplay between these proteins, we studied Cx40-null mice, a model of renin-dependent hypertension which displays an altered endothelium-dependent relaxation of the aorta because of reduced eNOS levels. These mice, which were either untreated or subjected to the 1-kidney, 1-clip (1K1C) procedure, a model of volume-dependent hypertension, were compared with control mice submitted to either the 1K1C or the 2-kidney, 1-clip (2K1C) procedure, a model of renin-dependent hypertension. All operated mice became hypertensive and featured hypertrophy and altered Cx expression of the aorta. The combination of volume- and renin-dependent hypertension in Cx40-/- 1K1C mice raised blood pressure and cardiac weight index. Under these conditions, all aortas showed increased levels of Cx40 in endothelial cells and of both Cx37 and Cx45 in smooth muscle cells. In the wild-type 1K1C mice, the interactions between Cx40 and Cx37 with eNOS were enhanced, resulting in increased NO release. The Cx40-eNOS interaction could not be observed in mice lacking Cx40, which also featured decreased levels of eNOS. In these animals, the volume overload caused by the 1K1C procedure resulted in increased phosphorylation of eNOS and in a higher NO release. The findings provide evidence that Cx40 and Cx37 play an in vivo role in the regulation of eNOS.
Resumo:
BACKGROUND: A few studies have suggested an association between prenatal exposure to methylmercury and decreased heart rate variability (HRV) related to autonomic heart function, but no study has examined this association using baroreflex sensitivity (BRS). In this study we assessed the distribution of BRS and immediate orthostatic hypotension (IOH) in young Seychellois adults and their associations with exposure to prenatal and recent postnatal methylmercury. METHODS: Subjects in the Seychelles Child Development Study (SCDS) main cohort were evaluated at age 19 years. Non-invasive beat-to-beat blood pressure (BP) monitoring (Finapres, Ohmeda) was performed at rest and during active standing in 95 consecutive subjects. Recent postnatal mercury exposure was measured in subjects' hair at the age of 19 years and prenatal exposure in maternal hair grown during pregnancy. BRS was estimated by sequence analysis to identify spontaneous ascending and descending BP ramps. HRV was estimated by the following markers: PNN50 (relative numbers of normal-to-normal intervals which are shorter by more than 50 ms than the immediately following normal-to-normal intervals); rMSSD (root mean of the squared sum of successive interval differences); LF/HF (low frequency/high frequency component ratio); ratio of the mean expiratory/inspiratory RR intervals (EI ratio); and the ratio between the longest RR interval 30 s after active standing and the shortest RR interval at 15 s (Max30/Min15). IOH was estimated by the deepest BP fall within the first 15 s after active standing up. RESULTS: Prenatal MeHg exposures were similar in boys and girls (6.7±4.3, 6.7±3.8 ng/g) but recent postnatal mercury levels were higher in males than females (11.2±5.8 vs 7.9±4.3 ng/g, p=0.003). Markers of autonomic heart rate control were within the normal range (BRS: 24.8±7 ms/mm Hg, PNN50: 24.9±6.8%, rMSSD: 68±22, LF/HF: 0.61±0.28) in both sexes. After standing, 51.4% of subjects had a transient systolic BP drop>40 mm Hg, but only 5.3% reported dizziness or had syncope. Prenatal and recent postnatal MeHg levels, overall, were not associated with BRS, E/I ratio, PNN50, rMSSD, LF/HF ratio, Max30/Min15 ratio, and IOH. CONCLUSIONS: This study provides no support for the hypothesis that prenatal or recent postnatal MeHg exposure from fish consumption is associated with impaired autonomic heart rate control.
Resumo:
In 2014, the debate on the indication of revascularization in case of asymptomatic carotid disease continued, while another one regarding the use of surgery vs. stenting addressed some new issues regarding the long-term cardiac risk of these patients. Renal arteries interventions trials were disappointing, as neither renal denervation nor renal artery stenting was found associated with better blood pressure management or outcome. In contrast, in lower-extremities artery disease, the endovascular techniques represent in 2014 major alternatives to surgery, even in distal arteries, with new insights regarding the interest of drug-eluting balloons. Regarding the aorta, the ESC published its first guidelines document on the entire vessel, emphasizing on the role of every cardiologist for screening abdominal aorta aneurysm during echocardiography. Among vascular wall biomarkers, the aorta stiffness is of increasing interest with new data and meta-analysis confirming its ability to stratify risk, whereas carotid intima-media thickness showed poor performances in terms of reclassifying patients into risk categories beyond risk scores. Regarding the veins, new data suggest the interest of D-dimers and residual venous thrombosis to help the decision of anti-coagulation prolongation or discontinuation after the initial period of treatment for deep vein thrombosis.
Resumo:
PURPOSE: To preliminarily test the hypothesis that fluorine 19 ((19)F) magnetic resonance (MR) imaging enables the noninvasive in vivo identification of plaque inflammation in a mouse model of atherosclerosis, with histologic findings as the reference standard. MATERIALS AND METHODS: The animal studies were approved by the local animal ethics committee. Perfluorocarbon (PFC) emulsions were injected intravenously in a mouse model of atherosclerosis (n = 13), after which (19)F and anatomic MR imaging were performed at the level of the thoracic aorta and its branches at 9.4 T. Four of these animals were imaged repeatedly (at 2-14 days) to determine the optimal detection time. Repeated-measures analysis of variance with a Tukey test was applied to determine if there was a significant change in (19)F signal-to-noise ratio (SNR) of the plaques and liver between the time points. Six animals were injected with a PFC emulsion that also contained a fluorophore. As a control against false-positive results, wild-type mice (n = 3) were injected with a PFC emulsion, and atherosclerotic mice were injected with a saline solution (n = 2). The animals were sacrificed after the last MR imaging examination, after which high-spatial-resolution ex vivo MR imaging and bright-field and immunofluorescent histologic examination were performed. RESULTS: (19)F MR signal was detected in vivo in plaques in the aortic arch and its branches. The SNR was found to significantly increase up to day 6 (P < .001), and the SNR of all mice at this time point was 13.4 ± 3.3. The presence of PFC and plaque in the excised vessels was then confirmed both through ex vivo (19)F MR imaging and histologic examination, while no signal was detected in the control animals. Immunofluorescent histologic findings confirmed the presence of PFC in plaque macrophages. CONCLUSION: (19)F MR imaging allows the noninvasive in vivo detection of inflammation in atherosclerotic plaques in a mouse model of atherosclerosis and opens up new avenues for both the early detection of vulnerable atherosclerosis and the elucidation of inflammation mechanisms in atherosclerosis.
Resumo:
Avalanche hazard maps of high accuracy are difficult to produce. For land-use planning and management purposes, a good knowledge of extreme run-out zones and frequencies of avalanches is required. In the present work, vegetation recognition (especially focused on Pinus uncinata trees) and dendrochronological techniques are used to characterize avalanches that have occurred in historical times, helping to determine both the extent of large or extreme avalanches and their occurrence in time. Vegetation was studied at the Canal del Roc Roig (eastern Pyrenees, Spain) avalanche path. The avalanches descending this path affect the railway that reaches the Vall de Núria resort and the run-up to the opposite slope. During winter 1996, two important avalanches affecting this path were well documented. These are compared with the results of the vegetation study, consisting of an inventory of flora, the recording of vegetation damages along eight transverse profiles at different altitudes on the path and a dendrochronological sampling campaign. The data obtained contributed to a characterization of the predominant snow accumulation in the starting zone, the 1996 avalanches and the range of frequencies of large avalanches. Also, traces of avalanches that increase the path mapped in the avalanche paths map published by the Institut Cartogràfic de Catalunya in 2000 were identified, improving the initial existing information.
Resumo:
Avalanche hazard maps of high accuracy are difficult to produce. For land-use planning and management purposes, a good knowledge of extreme run-out zones and frequencies of avalanches is required. In the present work, vegetation recognition (especially focused on Pinus uncinata trees) and dendrochronological techniques are used to characterize avalanches that have occurred in historical times, helping to determine both the extent of large or extreme avalanches and their occurrence in time. Vegetation was studied at the Canal del Roc Roig (eastern Pyrenees, Spain) avalanche path. The avalanches descending this path affect the railway that reaches the Vall de Núria resort and the run-up to the opposite slope. During winter 1996, two important avalanches affecting this path were well documented. These are compared with the results of the vegetation study, consisting of an inventory of flora, the recording of vegetation damages along eight transverse profiles at different altitudes on the path and a dendrochronological sampling campaign. The data obtained contributed to a characterization of the predominant snow accumulation in the starting zone, the 1996 avalanches and the range of frequencies of large avalanches. Also, traces of avalanches that increase the path mapped in the avalanche paths map published by the Institut Cartogràfic de Catalunya in 2000 were identified, improving the initial existing information.
Resumo:
Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.
Resumo:
Background: The aim was to test the hypothesis that the blood serum of rats subjected to recurrent airway obstructions mimicking obstructive sleep apnea (OSA) induces early activation of bone marrow-derived mesenchymal stem cells (MSC) and enhancement of endothelial wound healing. Methods: We studied 30 control rats and 30 rats subjected to recurrent obstructive apneas (60 per hour, lasting 15 s each, for 5 h). The migration induced in MSC by apneic serum was measured by transwell assays. MSC-endothelial adhesion induced by apneic serum was assessed by incubating fluorescent-labelled MSC on monolayers of cultured endothelial cells from rat aorta. A wound healing assay was used to investigate the effect of apneic serum on endothelial repair. Results: Apneic serum showed significant increase in chemotaxis in MSC when compared with control serum: the normalized chemotaxis indices were 2.20 +- 0.58 (m +- SE) and 1.00 +- 0.26, respectively (p < 0.05). MSC adhesion to endothelial cells was greater (1.75 +- 0.14 -fold; p < 0.01) in apneic serum than in control serum. When compared with control serum, apneic serum significantly increased endothelial wound healing (2.01 +- 0.24 -fold; p < 0.05). Conclusions: The early increases induced by recurrent obstructive apneas in MSC migration, adhesion and endothelial repair suggest that these mechanisms play a role in the physiological response to the challenges associated to OSA.
Resumo:
Elevated serum phosphorus, calcium, and fibroblast growth factor 23 (FGF23) levels are associated with cardiovascular disease in chronic renal disease. This study evaluated the effects of sucroferric oxyhydroxide (PA21), a new iron-based phosphate binder, versus lanthanum carbonate (La) and sevelamer carbonate (Se), on serum FGF23, phosphorus, calcium, and intact parathyroid hormone (iPTH) concentrations, and the development of vascular calcification in adenine-induced chronic renal failure (CRF) rats. After induction of CRF, renal function was significantly impaired in all groups: uremic rats developed severe hyperphosphatemia, and serum iPTH increased significantly. All uremic rats (except controls) then received phosphate binders for 4 weeks. Hyperphosphatemia and increased serum iPTH were controlled to a similar extent in all phosphate binder-treatment groups. Only sucroferric oxyhydroxide was associated with significantly decreased FGF23. Vascular calcifications of the thoracic aorta were decreased by all three phosphate binders. Calcifications were better prevented at the superior part of the thoracic and abdominal aorta in the PA21 treated rats. In adenine-induced CRF rats, sucroferric oxyhydroxide was as effective as La and Se in controlling hyperphosphatemia, secondary hyperparathyroidism, and vascular calcifications. The role of FGF23 in calcification remains to be confirmed.
Resumo:
This paper reports an experiment that investigated people"s body ownership of an avatar that was observed in a virtual mirror. Twenty subjects were recruited in a within-groups study where 10 first experienced a virtual character that synchronously reflected their upper-body movements as seen in a virtual mirror, and then an asynchronous condition where the mirror avatar displayed prerecorded actions, unrelated to those of the participant. The other 10 subjects experienced the conditions in the opposite order. In both conditions the participant could carry out actions that led to elevation above ground level, as seen from their first person perspective and correspondingly in the mirror. A rotating virtual fan eventually descended to 2m above the ground. The hypothesis was that synchronous mirror reflection would result in higher subjective sense of ownership. A questionnaire analysis showed that the body ownership illusion was significantly greater for thesynchronous than asynchronous condition. Additionally participants in the synchronous condition avoided collision with the descending fan significantly more often than those in the asynchronous condition. The results of this experiment are put into context within similar experiments on multisensory correlation and body ownership within cognitive neuroscience.
Resumo:
Atherosclerosis is a chronic cardiovascular disease that involves the thicken¬ing of the artery walls as well as the formation of plaques (lesions) causing the narrowing of the lumens, in vessels such as the aorta, the coronary and the carotid arteries. Magnetic resonance imaging (MRI) is a promising modality for the assessment of atherosclerosis, as it is a non-invasive and patient-friendly procedure that does not use ionizing radiation. MRI offers high soft tissue con¬trast already without the need of intravenous contrast media; while modifica¬tion of the MR pulse sequences allows for further adjustment of the contrast for specific diagnostic needs. As such, MRI can create angiographic images of the vessel lumens to assess stenoses at the late stage of the disease, as well as blood flow-suppressed images for the early investigation of the vessel wall and the characterization of the atherosclerotic plaques. However, despite the great technical progress that occurred over the past two decades, MRI is intrinsically a low sensitive technique and some limitations still exist in terms of accuracy and performance. A major challenge for coronary artery imaging is respiratory motion. State- of-the-art diaphragmatic navigators rely on an indirect measure of motion, per¬form a ID correction, and have long and unpredictable scan time. In response, self-navigation (SM) strategies have recently been introduced that offer 100% scan efficiency and increased ease of use. SN detects respiratory motion di¬rectly from the image data obtained at the level of the heart, and retrospectively corrects the same data before final image reconstruction. Thus, SN holds po-tential for multi-dimensional motion compensation. To this regard, this thesis presents novel SN methods that estimate 2D and 3D motion parameters from aliased sub-images that are obtained from the same raw data composing the final image. Combination of all corrected sub-images produces a final image with reduced motion artifacts for the visualization of the coronaries. The first study (section 2.2, 2D Self-Navigation with Compressed Sensing) consists of a method for 2D translational motion compensation. Here, the use of com- pressed sensing (CS) reconstruction is proposed and investigated to support motion detection by reducing aliasing artifacts. In healthy human subjects, CS demonstrated an improvement in motion detection accuracy with simula¬tions on in vivo data, while improved coronary artery visualization was demon¬strated on in vivo free-breathing acquisitions. However, the motion of the heart induced by respiration has been shown to occur in three dimensions and to be more complex than a simple translation. Therefore, the second study (section 2.3,3D Self-Navigation) consists of a method for 3D affine motion correction rather than 2D only. Here, different techniques were adopted to reduce background signal contribution in respiratory motion tracking, as this can be adversely affected by the static tissue that surrounds the heart. The proposed method demonstrated to improve conspicuity and vi¬sualization of coronary arteries in healthy and cardiovascular disease patient cohorts in comparison to a conventional ID SN method. In the third study (section 2.4, 3D Self-Navigation with Compressed Sensing), the same tracking methods were used to obtain sub-images sorted according to the respiratory position. Then, instead of motion correction, a compressed sensing reconstruction was performed on all sorted sub-image data. This process ex¬ploits the consistency of the sorted data to reduce aliasing artifacts such that the sub-image corresponding to the end-expiratory phase can directly be used to visualize the coronaries. In a healthy volunteer cohort, this strategy improved conspicuity and visualization of the coronary arteries when compared to a con¬ventional ID SN method. For the visualization of the vessel wall and atherosclerotic plaques, the state- of-the-art dual inversion recovery (DIR) technique is able to suppress the signal coming from flowing blood and provide positive wall-lumen contrast. How¬ever, optimal contrast may be difficult to obtain and is subject to RR variability. Furthermore, DIR imaging is time-inefficient and multislice acquisitions may lead to prolonged scanning times. In response and as a fourth study of this thesis (chapter 3, Vessel Wall MRI of the Carotid Arteries), a phase-sensitive DIR method has been implemented and tested in the carotid arteries of a healthy volunteer cohort. By exploiting the phase information of images acquired after DIR, the proposed phase-sensitive method enhances wall-lumen contrast while widens the window of opportunity for image acquisition. As a result, a 3-fold increase in volumetric coverage is obtained at no extra cost in scanning time, while image quality is improved. In conclusion, this thesis presented novel methods to address some of the main challenges for MRI of atherosclerosis: the suppression of motion and flow artifacts for improved visualization of vessel lumens, walls and plaques. Such methods showed to significantly improve image quality in human healthy sub¬jects, as well as scan efficiency and ease-of-use of MRI. Extensive validation is now warranted in patient populations to ascertain their diagnostic perfor¬mance. Eventually, these methods may bring the use of atherosclerosis MRI closer to the clinical practice. Résumé L'athérosclérose est une maladie cardiovasculaire chronique qui implique le épaississement de la paroi des artères, ainsi que la formation de plaques (lé¬sions) provoquant le rétrécissement des lumières, dans des vaisseaux tels que l'aorte, les coronaires et les artères carotides. L'imagerie par résonance magné¬tique (IRM) est une modalité prometteuse pour l'évaluation de l'athérosclérose, car il s'agit d'une procédure non-invasive et conviviale pour les patients, qui n'utilise pas des rayonnements ionisants. L'IRM offre un contraste des tissus mous très élevé sans avoir besoin de médias de contraste intraveineux, tan¬dis que la modification des séquences d'impulsions de RM permet en outre le réglage du contraste pour des besoins diagnostiques spécifiques. À ce titre, l'IRM peut créer des images angiographiques des lumières des vaisseaux pour évaluer les sténoses à la fin du stade de la maladie, ainsi que des images avec suppression du flux sanguin pour une première enquête des parois des vais¬seaux et une caractérisation des plaques d'athérosclérose. Cependant, malgré les grands progrès techniques qui ont eu lieu au cours des deux dernières dé¬cennies, l'IRM est une technique peu sensible et certaines limitations existent encore en termes de précision et de performance. Un des principaux défis pour l'imagerie de l'artère coronaire est le mou¬vement respiratoire. Les navigateurs diaphragmatiques de pointe comptent sur une mesure indirecte de mouvement, effectuent une correction 1D, et ont un temps d'acquisition long et imprévisible. En réponse, les stratégies d'auto- navigation (self-navigation: SN) ont été introduites récemment et offrent 100% d'efficacité d'acquisition et une meilleure facilité d'utilisation. Les SN détectent le mouvement respiratoire directement à partir des données brutes de l'image obtenue au niveau du coeur, et rétrospectivement corrigent ces mêmes données avant la reconstruction finale de l'image. Ainsi, les SN détiennent un poten¬tiel pour une compensation multidimensionnelle du mouvement. A cet égard, cette thèse présente de nouvelles méthodes SN qui estiment les paramètres de mouvement 2D et 3D à partir de sous-images qui sont obtenues à partir des mêmes données brutes qui composent l'image finale. La combinaison de toutes les sous-images corrigées produit une image finale pour la visualisation des coronaires ou les artefacts du mouvement sont réduits. La première étude (section 2.2,2D Self-Navigation with Compressed Sensing) traite d'une méthode pour une compensation 2D de mouvement de translation. Ici, on étudie l'utilisation de la reconstruction d'acquisition comprimée (compressed sensing: CS) pour soutenir la détection de mouvement en réduisant les artefacts de sous-échantillonnage. Chez des sujets humains sains, CS a démontré une amélioration de la précision de la détection de mouvement avec des simula¬tions sur des données in vivo, tandis que la visualisation de l'artère coronaire sur des acquisitions de respiration libre in vivo a aussi été améliorée. Pourtant, le mouvement du coeur induite par la respiration se produit en trois dimensions et il est plus complexe qu'un simple déplacement. Par conséquent, la deuxième étude (section 2.3, 3D Self-Navigation) traite d'une méthode de cor¬rection du mouvement 3D plutôt que 2D uniquement. Ici, différentes tech¬niques ont été adoptées pour réduire la contribution du signal du fond dans le suivi de mouvement respiratoire, qui peut être influencé négativement par le tissu statique qui entoure le coeur. La méthode proposée a démontré une amélioration, par rapport à la procédure classique SN de correction 1D, de la visualisation des artères coronaires dans le groupe de sujets sains et des pa¬tients avec maladies cardio-vasculaires. Dans la troisième étude (section 2.4,3D Self-Navigation with Compressed Sensing), les mêmes méthodes de suivi ont été utilisées pour obtenir des sous-images triées selon la position respiratoire. Au lieu de la correction du mouvement, une reconstruction de CS a été réalisée sur toutes les sous-images triées. Cette procédure exploite la cohérence des données pour réduire les artefacts de sous- échantillonnage de telle sorte que la sous-image correspondant à la phase de fin d'expiration peut directement être utilisée pour visualiser les coronaires. Dans un échantillon de volontaires en bonne santé, cette stratégie a amélioré la netteté et la visualisation des artères coronaires par rapport à une méthode classique SN ID. Pour la visualisation des parois des vaisseaux et de plaques d'athérosclérose, la technique de pointe avec double récupération d'inversion (DIR) est capa¬ble de supprimer le signal provenant du sang et de fournir un contraste posi¬tif entre la paroi et la lumière. Pourtant, il est difficile d'obtenir un contraste optimal car cela est soumis à la variabilité du rythme cardiaque. Par ailleurs, l'imagerie DIR est inefficace du point de vue du temps et les acquisitions "mul- tislice" peuvent conduire à des temps de scan prolongés. En réponse à ce prob¬lème et comme quatrième étude de cette thèse (chapitre 3, Vessel Wall MRI of the Carotid Arteries), une méthode de DIR phase-sensitive a été implémenté et testé
Resumo:
The goal of this study was to assess the localization and types of thrombosed plaques in cases of sudden cardiac death attributed to coronary artery disease and to evaluate possible correlations with body mass index (BMI) and increased heart weight. This retrospective study was performed on forensic cases for which the cause of death was attributed to coronary artery disease. A complete autopsy and a multi-phase postmortem computed tomography (CT) angiography (MPMCTA) were performed in all cases. Eighty-five cases were selected (mean age, 55.18 ± 11.04 years; 72 men and 13 women). MPMCTA performed prior to autopsy enabled an evaluation of coronary artery perfusion before dissection of the body and helped therefore to guide sampling for histology. An acute coronary thrombosis was found in 57 cases, which included plaque erosion in 26 cases (mean age, 46.73 ± 8.33 years) and rupture or intra-plaque hemorrhage in 31 cases (mean age, 58.23 ± 10.62 years). Erosions were most frequently found in the left anterior descending artery (61.5 %), while only 35.48 % of ruptures were observed in this artery. Chronic coronary pathology was considered as the main cause of death in 28 cases (mean age, 59.64 ± 9.47 years). Sixty-two of the cases (72.94 %) had a BMI in the overweight category (BMI ≥25), with the highest mean BMI in patients with chronic coronary pathology without acute thrombosis found at autopsy. The heart weight was above the predicted reference values in 52 cases (61.18 %). Our results are in accordance with previously published studies on the spatial distribution of vulnerable plaques. We observed a higher percentage of eroded plaques than previously reported. Patients with coronary erosions were significantly younger than those with plaque rupture or those without an acute coronary thrombosis (p values <0.0001). BMI and heart weight were significantly higher for cases without thrombosis in comparison with those with plaque rupture (p values 0.028 and 0.003, respectively). Our results indicating that increased BMI and overweight hearts are associated with chronic ischemic heart disease are compatible with clinical studies. Performing more postmortem studies on forensic autopsies, including modern radiological examinations with MPMCTA, can enhance the detection of vulnerable plaques in living patients and prevent sudden cardiac death.
Resumo:
OBJECTIVES: To learn upon incidence, underlying mechanisms and effectiveness of treatment strategies in patients with central airway and pulmonary parenchymal aorto-bronchial fistulation after thoracic endovascular aortic repair (TEVAR). METHODS: Analysis of an international multicentre registry (European Registry of Endovascular Aortic Repair Complications) between 2001 and 2012 with a total caseload of 4680 TEVAR procedures (14 centres). RESULTS: Twenty-six patients with a median age of 70 years (interquartile range: 60-77) (35% female) were identified. The incidence of either central airway (aorto-bronchial) or pulmonary parenchymal (aorto-pulmonary) fistulation (ABPF) in the entire cohort after TEVAR in the study period was 0.56% (central airway 58%, peripheral parenchymal 42%). Atherosclerotic aneurysm formation was the leading indication for TEVAR in 15 patients (58%). The incidence of primary endoleaks after initial TEVAR was n = 10 (38%), of these 80% were either type I or type III endoleaks. Fourteen patients (54%) developed central left bronchial tree lesions, 11 patients (42%) pulmonary parenchymal lesions and 1 patient (4%) developed a tracheal lesion. The recognized mechanism of ABPF was external compression of the bronchial tree in 13 patients (50%), the majority being due to endoleak formation, further ischaemia due to extensive coverage of bronchial feeding arteries in 3 patients (12%). Inflammation and graft erosion accounted for 4 patients (30%) each. Cumulative survival during the entire study period was 39%. Among deaths, 71% were attributed to ABPF. There was no difference in survival in patients having either central airway or pulmonary parenchymal ABPF (33 vs 45%, log-rank P = 0.55). Survival with a radical surgical approach was significantly better when compared with any other treatment strategy in terms of overall survival (63 vs 32% and 63 vs 21% at 1 and 2 years, respectively), as well as in terms of fistula-related survival (63 vs 43% and 63 vs 43% at 1 and 2 years, respectively). CONCLUSIONS: ABPF is a rare but highly lethal complication after TEVAR. The leading mechanism behind ABPF seems to be a continuing external compression of either the bronchial tree or left upper lobe parenchyma. In this setting, persisting or newly developing endoleak formation seems to play a crucial role. Prognosis does not differ in patients with central airway or pulmonary parenchymal fistulation. Radical bronchial or pulmonary parenchymal repair in combination with stent graft removal and aortic reconstruction seems to be the most durable treatment strategy.
Resumo:
As lesões traumáticas mediastinais constituem achados pouco freqüentes no trauma torácico, mas são de extrema importância, por representarem mau prognóstico, dada a sua gravidade e lesões associadas. O trauma mediastinal é cada vez mais diagnosticado pela tomografia computadorizada, em especial pelo rápido tempo de aquisição decorrente da técnica helicoidal, que permite a avaliação de pacientes em estado grave, possibilitando a adoção de conduta terapêutica eficiente. Os autores estudaram 11 pacientes com trauma torácico submetidos a tomografia computadorizada, os quais apresentaram lesões mediastinais. A hemorragia mediastinal representou a lesão mais comum nesta casuística, manifestando-se sob a forma de infiltração da gordura mediastinal, com a presença de material denso permeando os espaços mediastinais, ou sob a forma de hematoma. O hemopericárdio representou a segunda lesão mais comum, caracterizado por material denso ou líquido no interior do pericárdio. As lesões aórticas foram observadas em três casos, caracterizadas por irregularidade parietal no contorno aórtico ou por pseudo-aneurisma. Neste trabalho o trauma torácico fechado foi observado em seis casos, enquanto o trauma aberto ocorreu em cinco pacientes. As causas de trauma fechado foram atropelamento, colisão automobilística e queda de altura. A forma penetrante de traumatismo torácico decorreu de dois modos de agressão: lesão por arma de fogo e lesão por arma branca