844 resultados para Defeitos
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective of this work is to conduct a comparative study between the fuse key and the single-phase seccionalizador, which are protective equipment used in an electricity distribution networks. This study has also the purpose to reduce the number of electrical power breakdown. Distribution networks are not free from faults, disturbances and failures, then the occurrence of adversities on the network, which may be transient or permanent faults, results in the interruption of electric power. Thus, there are protective systems of distribution networks, which aims to ensure that the electric system continues to function. The incidence of transient faults in the distribution network of this electricity company was used to generate immediate shutdown of customers due to the bad use of fuses as protective equipment by the reclosers. With the use of the fuse switch in the distribution network, there was the immediate shutdown of customers, however, using the single-phase seccionalizador as protective equipment by the reclosers, there are three attempts to restart the electricity power. As the attempts to restart the electricity power are able to eliminate a transient fault, not causing shutdown of any costumer, with the implementation of single-phase sectionalizers to replace the fuses, the number of company shutdowns due to transient faults was reduced by 47.6%
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A espécie amazônica Paricá (Schizolobium amazonicum Herb) apresenta rápidos incrementos em altura e diâmetro em poucos anos de cultivo e desenvolve uma madeira com pequena quantidade de nós e defeitos, característica fundamental na sua utilização para fins estruturais. O objetivo deste trabalho foi determinar as propriedades de resistência e rigidez de peças da madeira Paricá em dimensões estruturais, de acordo com a norma ABNT NBR 7190: 2011, bem como realizar a classificação visual das peças para determinação de defeitos como: nós, inclinação de fibras, empenamentos, rachas e fendas. Conclui-se que a madeira de Paricá é classificada como classe C 20 das dicotiledôneas e possui baixa densidade, boa resistência à compressão paralela, grande potencial de utilização na construção civil quando comparada com outras espécies e, em relação à classificação visual, poucos nós, grã direita e poucos empenamentos e distorções.
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective of this work is to conduct a comparative study between the fuse key and the single-phase seccionalizador, which are protective equipment used in an electricity distribution networks. This study has also the purpose to reduce the number of electrical power breakdown. Distribution networks are not free from faults, disturbances and failures, then the occurrence of adversities on the network, which may be transient or permanent faults, results in the interruption of electric power. Thus, there are protective systems of distribution networks, which aims to ensure that the electric system continues to function. The incidence of transient faults in the distribution network of this electricity company was used to generate immediate shutdown of customers due to the bad use of fuses as protective equipment by the reclosers. With the use of the fuse switch in the distribution network, there was the immediate shutdown of customers, however, using the single-phase seccionalizador as protective equipment by the reclosers, there are three attempts to restart the electricity power. As the attempts to restart the electricity power are able to eliminate a transient fault, not causing shutdown of any costumer, with the implementation of single-phase sectionalizers to replace the fuses, the number of company shutdowns due to transient faults was reduced by 47.6%
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Monitorar a condição de uso de toda a extensão das rodovias brasileiras é tarefa dispendiosa e demorada. Este trabalho trata de novas técnicas que permitem o levantamento da condição da superfície dos pavimentos rodoviários de forma ágil utilizando imagens hiperespectrais de sensor digital aeroembarcado. Nos últimos anos, um número crescente de imagens de alta resolução espacial tem surgido no mercado mundial com o aparecimento dos novos satélites e sensores aeroembarcados de sensoriamento remoto. Propõe-se uma metodologia para identificação dos pavimentos asfálticos e classificação das principais ocorrências dos defeitos na superfície do pavimento. A primeira etapa da metodologia é a identificação da superfície asfáltica na imagem, utilizando uma classificação híbrida baseada inicialmente em pixel e depois refinada por objetos. A segunda etapa da metodologia é a identificação e classificação das ocorrências dos principais defeitos nos pavimentos flexíveis que são observáveis nas imagens de alta resolução espacial. Esta última etapa faz uso intensivo das novas técnicas de classificação de imagens baseadas em objetos. O resultado final é a geração de índices da condição da superfície do pavimento a partir das imagens que possam ser comparados com os indicadores vigentes da condição da superfície do pavimento já normatizados pelos órgãos competentes no país.
Resumo:
Maturity-onset diabetes of the young (MODY) is characterized by an autosomal dominant mode of inheritance, early onset of hyperglycemia, and defects of insulin secretion. MODY subtypes described present genetic, metabolic, and clinical differences. MODY 2 is characterized by mild asymptomatic fasting hyperglycemia, and rarely requires pharmacological treatment. Hence, precise diagnosis of MODY is important for determining management and prognosis. We report two heterozygous GCK mutations identified during the investigation of short stature. Case 1: a prepubertal 14-year-old boy was evaluated for constitutional delay of growth and puberty. During follow-up, he showed abnormal fasting glucose (113 mg/dL), increased level of HbA1c (6.6%), and negative beta-cell antibodies. His father and two siblings also had slightly elevated blood glucose levels. The mother had normal glycemia. A GCK heterozygous missense mutation, p.Arg191Trp, was identified in the proband. Eighteen family members were screened for this mutation, and 11 had the mutation in heterozygous state. Case 2: a 4-year-old boy investigated for short stature revealed no other laboratorial alterations than elevated glycemia (118 mg/dL); beta-cell antibodies were negative. His father, a paternal aunt, and the paternal grandmother also had slightly elevated glycemia, whereas his mother had normal glycemia. A GCK heterozygous missense mutation, p.Glu221Lys, was identified in the index patient and in four family members. All affected patients had mild elevated glycemia. Individuals with normal glycemia did not harbor mutations. GCK mutation screening should be considered in patients with chronic mild early-onset hyperglycemia, family history of impaired glycemia, and negative beta-cell antibodies. Arq Bras Endocrinol Metab. 2012;56(8):519-24