897 resultados para Coal-fired power plants
Resumo:
The quality and the reliability of the power generated by large grid-connected photovoltaic (PV) plants are negatively affected by the source characteristic variability. This paper deals with the smoothing of power fluctuations because of geographical dispersion of PV systems. The fluctuation frequency and the maximum fluctuation registered at a PV plant ensemble are analyzed to study these effects. We propose an empirical expression to compare the fluctuation attenuation because of both the size and the number of PV plants grouped. The convolution of single PV plants frequency distribution functions has turned out to be a successful tool to statistically describe the behavior of an ensemble of PV plants and determine their maximum output fluctuation. Our work is based on experimental 1-s data collected throughout 2009 from seven PV plants, 20 MWp in total, separated between 6 and 360 km.
Resumo:
To date, the majority of quality controls performed at PV plants are based on the measurement of a small sample of individual modules. Consequently, there is very little representative data on the real Standard Test Conditions (STC) power output values for PV generators. This paper presents the power output values for more than 1300 PV generators having a total installed power capacity of almost 15.3 MW. The values were obtained by the INGEPER-UPNA group, in collaboration with the IES-UPM, through a study to monitor the power output of a number of PV plants from 2006 to 2009. This work has made it possible to determine, amongst other things, the power dispersion that can be expected amongst generators made by different manufacturers, amongst generators made by the same manufacturer but comprising modules of different nameplate ratings and also amongst generators formed by modules with the same characteristics. The work also analyses the STC power output evolution over time in the course of this 4-year study. The values presented here could be considered to be representative of generators with fault-free modules.
Resumo:
Renewable energy sources are believed to reduce drastically greenhouse gas emissions that would otherwise be generated from fossil fuels used to generate electricity. This implies that a unit of renewable energy will replace a unit of fossil-fuel, with its CO2 emissions, on an equivalent basis (with no other effects on the grid). But, the fuel economy and emissions in the existing power systems are not proportional with the electricity production of intermittent sources due to cycling of the fossil fuel plants that make up the balance of the grid (i.e. changing the power output makes thermal units to operate less efficiently). This study focuses in the interactions between wind generation and thermal plants cycling, by establishing the levels of extra fuel use caused by decreased efficiencies of fossil back-up for wind electricity in Spain. We analyze the production of all thermal plants in 2011, studying different scenarios where wind penetration causes major deviations in programming, while we define a procedure for quantifying the carbon reductions by using emission factors and efficiency curves from the existing installations. The objectives are to discuss the real contributions of renewable energies to the environmental targets as well as suggest alternatives that would improve the reliability of future power systems.
Resumo:
The self-ignition of all kind of powdery substances is a topic studied over the years, especially if the dusty substance is coal or substances related with coal because it may be a cause of energetic materials and human losses. But it is important to note that this is not the only risk in industrial plants that generate or store solid substances. Every combustible powders are potentially explosive and they may cause serious consequences if all the necessary factors are developed. Due to this potentially risk, it is essential a good characterization and knowledge of all the parameters involved in those processes.
Resumo:
This paper proposes a first study in-depth of solar-fossil hybridization from a general perspective. It develops a set of useful parameters for analyzing and comparing hybrid plants, it studies the case of hybridizing Brayton cycles with current solar technologies and shows a tentative extrapolation of the results to integrated combined cycle systems (ISCSS). In particular, three points have been analyzed: the technical requirements for solar technologies to be hybridized with Brayton cycles, the temperatures and pressures at which hybridization would produce maximum power per unit of fossil fuel, and their mapping to current solar technologies and Brayton cycles. Major conclusions are that a hybrid plant works in optimum conditions which are not equal to those of the solar or power blocks considered independently, and that hybridizing at the Brayton cycle of a combined cycle could be energetically advantageous.
Resumo:
The goal of this paper is to show how mathematics and computational science can help to design not only the geometry but also the operation conditions of different parts of a pulverized coal power plant.
Resumo:
Strict technical quality assurance procedures are essential for PV plant bankability. When large-scale PV plants are concerned, this is typically accomplished in three consecutive phases: an energy yield forecast, that is performed at the beginning of the project and is typically accomplished by means of a simulation exercise performed with dedicated software; a reception test campaign, that is performed at the end of the commissioning and consists of a set of tests for determining the efficiency and the reliability of the PV plant devices; and a performance analysis of the first years of operation, that consists in comparing the real energy production with the one calculated from the recorded operating conditions and taking into account the maintenance records. In the last six years, IES-UPM has offered both indoor and on-site quality control campaigns for more than 60 PV plants, with an accumulated power of more than 300 MW, in close contact with Engineering, Procurement and Construction Contractors and financial entities. This paper presents the lessons learned from such experience.
Resumo:
Forecasting the AC power output of a PV plant accurately is important both for plant owners and electric system operators. Two main categories of PV modeling are available: the parametric and the nonparametric. In this paper, a methodology using a nonparametric PV model is proposed, using as inputs several forecasts of meteorological variables from a Numerical Weather Forecast model, and actual AC power measurements of PV plants. The methodology was built upon the R environment and uses Quantile Regression Forests as machine learning tool to forecast AC power with a confidence interval. Real data from five PV plants was used to validate the methodology, and results show that daily production is predicted with an absolute cvMBE lower than 1.3%.
Resumo:
Short-term variability in the power generated by large grid-connected photovoltaic (PV) plants can negatively affect power quality and the network reliability. New grid-codes require combining the PV generator with some form of energy storage technology in order to reduce short-term PV power fluctuation. This paper proposes an effective method in order to calculate, for any PV plant size and maximum allowable ramp-rate, the maximum power and the minimum energy storage requirements alike. The general validity of this method is corroborated with extensive simulation exercises performed with real 5-s one year data of 500 kW inverters at the 38.5 MW Amaraleja (Portugal) PV plant and two other PV plants located in Navarra (Spain), at a distance of more than 660 km from Amaraleja.
Resumo:
The environmental performance of a 50 MW parabolic trough Concentrated Solar Power (CSP) plant hybridised with different fuels was determined using a Life Cycle Assessment methodology. Six different scenarios were investigated, half of which involved hybridisation with fossil fuels (natural gas, coal and fuel oil), and the other three involved hybridisation with renewable fuels (wheat straw, wood pellets and biogas). Each scenario was compared to a solar-only operation. Nine different environmental categories as well as the Cumulative Energy Demand and the Energy Payback Time (EPT) were evaluated using Simapro software for 1 MWh of electricity produced. The results indicate a worse environmental performance for a CSP plant producing 12% of the electricity from fuel than in a solar-only operation for every indicator, except for the eutrophication and toxicity categories, whose results for the natural gas scenario are slightly better. In the climate change category, the results ranged between 26.9 and 187 kg CO2 eq/MWh, where a solar-only operation had the best results and coal hybridisation had the worst. Considering a weighted single score indicator, the environmental impact of the renewable fuels scenarios is approximately half of those considered in fossil fuels, with the straw scenario showing the best results, and the coal scenario the worstones. EPT for solar-only mode is 1.44 years, while hybridisation scenarios EPT vary in a range of 1.72 -1.83 years for straw and pellets respectively. The fuels with more embodied energy are biomethane and wood pellets.
Resumo:
Concentrating Solar Power (CSP) plants typically incorporate one or various auxiliary boilers operating in parallel to the solar field to facilitate start up operations, provide system stability, avoid freezing of heat transfer fluid (HTF) and increase generation capacity. The environmental performance of these plants is highly influenced by the energy input and the type of auxiliary fuel, which in most cases is natural gas (NG). Replacing the NG with biogas or biomethane (BM) in commercial CSP installations is being considered as a means to produce electricity that is fully renewable and free from fossil inputs. Despite their renewable nature, the use of these biofuels also generates environmental impacts that need to be adequately identified and quantified. This paper investigates the environmental performance of a commercial wet-cooled parabolic trough 50 MWe CSP plant in Spain operating according to two strategies: solar-only, with minimum technically viable energy non-solar contribution; and hybrid operation, where 12 % of the electricity derives from auxiliary fuels (as permitted by Spanish legislation). The analysis was based on standard Life Cycle Assessment (LCA) methodology (ISO 14040-14040). The technical viability and the environmental profile of operating the CSP plant with different auxiliary fuels was evaluated, including: NG; biogas from an adjacent plant; and BM withdrawn from the gas network. The effect of using different substrates (biowaste, sewage sludge, grass and a mix of biowaste with animal manure) for the production of the biofuels was also investigated. The results showed that NG is responsible for most of the environmental damage associated with the operation of the plant in hybrid mode. Replacing NG with biogas resulted in a significant improvement of the environmental performance of the installation, primarily due to reduced impact in the following categories: natural land transformation, depletion of fossil resources, and climate change. However, despite the renewable nature of the biofuels, other environmental categories like human toxicity, eutrophication, acidification and marine ecotoxicity scored higher when using biogas and BM.
Resumo:
Esta tesis doctoral presenta un procedimiento integral de control de calidad en centrales fotovoltaicas, que comprende desde la fase inicial de estimación de las expectativas de producción hasta la vigilancia del funcionamiento de la instalación una vez en operación, y que permite reducir la incertidumbre asociada su comportamiento y aumentar su fiabilidad a largo plazo, optimizando su funcionamiento. La coyuntura de la tecnología fotovoltaica ha evolucionado enormemente en los últimos años, haciendo que las centrales fotovoltaicas sean capaces de producir energía a unos precios totalmente competitivos en relación con otras fuentes de energía. Esto hace que aumente la exigencia sobre el funcionamiento y la fiabilidad de estas instalaciones. Para cumplir con dicha exigencia, es necesaria la adecuación de los procedimientos de control de calidad aplicados, así como el desarrollo de nuevos métodos que deriven en un conocimiento más completo del estado de las centrales, y que permitan mantener la vigilancia sobre las mismas a lo largo del tiempo. Además, los ajustados márgenes de explotación actuales requieren que durante la fase de diseño se disponga de métodos de estimación de la producción que comporten la menor incertidumbre posible. La propuesta de control de calidad presentada en este trabajo parte de protocolos anteriores orientados a la fase de puesta en marcha de una instalación fotovoltaica, y las complementa con métodos aplicables a la fase de operación, prestando especial atención a los principales problemas que aparecen en las centrales a lo largo de su vida útil (puntos calientes, impacto de la suciedad, envejecimiento…). Además, incorpora un protocolo de vigilancia y análisis del funcionamiento de las instalaciones a partir de sus datos de monitorización, que incluye desde la comprobación de la validez de los propios datos registrados hasta la detección y el diagnóstico de fallos, y que permite un conocimiento automatizado y detallado de las plantas. Dicho procedimiento está orientado a facilitar las tareas de operación y mantenimiento, de manera que se garantice una alta disponibilidad de funcionamiento de la instalación. De vuelta a la fase inicial de cálculo de las expectativas de producción, se utilizan los datos registrados en las centrales para llevar a cabo una mejora de los métodos de estimación de la radiación, que es la componente que más incertidumbre añade al proceso de modelado. El desarrollo y la aplicación de este procedimiento de control de calidad se han llevado a cabo en 39 grandes centrales fotovoltaicas, que totalizan una potencia de 250 MW, distribuidas por varios países de Europa y América Latina. ABSTRACT This thesis presents a comprehensive quality control procedure to be applied in photovoltaic plants, which covers from the initial phase of energy production estimation to the monitoring of the installation performance, once it is in operation. This protocol allows reducing the uncertainty associated to the photovoltaic plants behaviour and increases their long term reliability, therefore optimizing their performance. The situation of photovoltaic technology has drastically evolved in recent years, making photovoltaic plants capable of producing energy at fully competitive prices, in relation to other energy sources. This fact increases the requirements on the performance and reliability of these facilities. To meet this demand, it is necessary to adapt the quality control procedures and to develop new methods able to provide a more complete knowledge of the state of health of the plants, and able to maintain surveillance on them over time. In addition, the current meagre margins in which these installations operate require procedures capable of estimating energy production with the lower possible uncertainty during the design phase. The quality control procedure presented in this work starts from previous protocols oriented to the commissioning phase of a photovoltaic system, and complete them with procedures for the operation phase, paying particular attention to the major problems that arise in photovoltaic plants during their lifetime (hot spots, dust impact, ageing...). It also incorporates a protocol to control and analyse the installation performance directly from its monitoring data, which comprises from checking the validity of the recorded data itself to the detection and diagnosis of failures, and which allows an automated and detailed knowledge of the PV plant performance that can be oriented to facilitate the operation and maintenance of the installation, so as to ensure a high operation availability of the system. Back to the initial stage of calculating production expectations, the data recorded in the photovoltaic plants is used to improved methods for estimating the incident irradiation, which is the component that adds more uncertainty to the modelling process. The development and implementation of the presented quality control procedure has been carried out in 39 large photovoltaic plants, with a total power of 250 MW, located in different European and Latin-American countries.
Resumo:
This paper presents a work whose objective is, first, to quantify the potential of the triticale biomass existing in each of the agricultural regions in the Madrid Community through a crop simulation model based on regression techniques and multiple correlation. Second, a methodology for defining which area has the best conditions for the installation of electricity plants from biomass has been described and applied. The study used a methodology based on compromise programming in a discrete multicriteria decision method (MDM) context. To make a ranking, the following criteria were taken into account: biomass potential, electric power infrastructure, road networks, protected spaces, and urban nuclei surfaces. The results indicate that, in the case of the Madrid Community, the Campiña region is the most suitable for setting up plants powered by biomass. A minimum of 17,339.9 tons of triticale will be needed to satisfy the requirements of a 2.2 MW power plant. The minimum range of action for obtaining the biomass necessary in Campiña region would be 6.6 km around the municipality of Algete, based on Geographic Information Systems. The total biomass which could be made available in considering this range in this region would be 18,430.68 t.
Resumo:
This report analyzes the basis of hydrogen and power integration strategies, by using water electrolysis processes as a means of flexible energy storage at large scales. It is a prospective study, where the scope is to describe the characteristics of current power systems (like the generation technologies, load curves and grid constraints), and define future scenarios of hydrogen for balancing the electrical grids, considering the efficiency, economy and easiness of operations. We focus in the "Spanish case", which is a good example for planning the transition from a power system holding large reserve capacities, high penetration of renewable energies and limited interconnections, to a more sustainable energy system being capable to optimize the volumes, the regulation modes, the utilization ratios and the impacts of the installations. Thus, we explore a novel aspect of the "hydrogen economy" which is based in the potentials of existing power systems and the properties of hydrogen as energy carrier, by considering the electricity generation and demand globally and determining the optimal size and operation of the hydrogen production processes along the country; e.g. the cost production of hydrogen becomes viable for a base-load scenario with 58 TWh/year of power surplus at 0.025 V/kWh, and large number electrolyzer plants (50 MW) running in variable mode (1-12 kA/m2)
Resumo:
Darwin observed that multiple, lowly organized, rudimentary, or exaggerated structures show increased relative variability. However, the cellular basis for these laws has never been investigated. Some animals, such as the nematode Caenorhabditis elegans, are famous for having organs that possess the same number of cells in all individuals, a property known as eutely. But for most multicellular creatures, the extent of cell number variability is unknown. Here we estimate variability in organ cell number for a variety of animals, plants, slime moulds, and volvocine algae. We find that the mean and variance in cell number obey a power law with an exponent of 2, comparable to Taylor's law in ecological processes. Relative cell number variability, as measured by the coefficient of variation, differs widely across taxa and tissues, but is generally independent of mean cell number among homologous tissues of closely related species. We show that the power law for cell number variability can be explained by stochastic branching process models based on the properties of cell lineages. We also identify taxa in which the precision of developmental control appears to have evolved. We propose that the scale independence of relative cell number variability is maintained by natural selection.