968 resultados para Cardiac diseases


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Medicina (Imunologia Clínica), Universidade de Lisboa, Faculdade de Medicina, 2016

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Coronary heart disease (CHD) is one of the leading causes of death in both men and women worldwide. Despite the common misconception that CHD is a ‘man's disease’, it is now well accepted that women endure worse clinical outcomes than men following CHD-related events. A number of studies have explored whether or not gender differences exist in patients presenting with CHD, and specifically whether women delay seeking help for cardiac conditions. UK and overseas studies on help-seeking for emergency cardiac events are contradictory, yet suggest that women often delay help-seeking. In addition, no studies have looked at presumed cardiac symptoms outside an emergency situation. Given the lack of understanding in this area, an explorative qualitative study on the gender differences in help-seeking for a non-emergency cardiac events is needed. Methods and analysis: A purposive sample of 20–30 participants of different ethnic backgrounds and ages attending a rapid access chest pain clinic will be recruited to achieve saturation. Semistructured interviews focusing on help-seeking decision-making for apparent cardiac symptoms will be undertaken. Interview data will be analysed thematically using qualitative software (NVivo) to understand any similarities and differences between the way men and women construct help-seeking. Findings will also be used to inform the preliminary development of a cardiac help-seeking intentions questionnaire. Ethics and dissemination: Ethical approvals were sought and granted. Namely, the University of Westminster (sponsor) and St Georges NHS Trust REC, and the Trust Research and Development Office granted approval to host the study on the Queen Mary's Roehampton site. The study is low risk, with interviews being conducted on hospital premises during working hours. Investigators will disseminate findings via presentations and publications. Participants will receive a written summary of the key findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Environmental tobacco smoke (ETS) is recognized as an occupational hazard in the hospitality industry. Although Portuguese legislation banned smoking in most indoor public spaces, it is still allowed in some restaurants/bars, representing a potential risk to the workers’ health, particularly for chronic respiratory diseases. The aims of this work were to characterize biomarkers of early genetic effects and to disclose proteomic signatures associated to occupational exposure to ETS and with potential to predict respiratory diseases development. A detailed lifestyle survey and clinical evaluation (including spirometry) were performed in 81 workers from Lisbon restaurants. ETS exposure was assessed through the level of PM 2.5 in indoor air and the urinary level of cotinine. The plasma samples were immunodepleted and analysed by 2D-SDSPAGE followed by in-gel digestion and LC-MS/MS. DNA lesions and chromosome damage were analysed innlymphocytes and in exfoliated buccal cells from 19 cigarette smokers, 29 involuntary smokers, and 33 non-smokers not exposed to tobacco smoke. Also, the DNA repair capacity was evaluated using an ex vivo challenge comet assay with an alkylating agent (EMS). All workers were considered healthy and recorded normal lung function. Interestingly, following 2D-DIGE-MS (MALDI-TOF/TOF), 61 plasma proteins were found differentially expressed in ETS-exposed subjects, including 38 involved in metabolism, acute-phase respiratory inflammation, and immune or vascular functions. On the other hand, the involuntary smokers showed neither an increased level of DNA/chromosome damage on lymphocytes nor an increased number of micronuclei in buccal cells, when compared to non-exposed non-smokers. Noteworthy, lymphocytes challenge with EMS resulted in a significantly lower level of DNA breaks in ETS-exposed as compared to non-exposed workers (P<0.0001) suggestive of an adaptive response elicited by the previous exposure to low levels of ETS. Overall, changes in proteome may be promising early biomarkers of exposure to ETS. Likewise, alterations of the DNA repair competence observed upon ETS exposure deserves to be further understood. Work supported by Fundação Calouste Gulbenkian, ACSS and FCT/Polyannual Funding Program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: As doenças cardiovasculares são a principal causa de morte na Europa e o sedentarismo é um dos seus principais fatores de risco. Os programas de reabilitação cardiovascular (RCV) no domicílio parecem ser eficazes na tolerância ao exercício. No entanto, torna-se difícil reproduzir um protocolo de exercícios no domicílio, por se tratar de estudos pouco específicos. Objetivo: Avaliar os efeitos de um programa de exercícios específico realizado no domicílio, na tolerância ao exercício em pacientes integrados num programa RCV. Metodologia: Estudo quase experimental composto por 20 indivíduos com pelo menos um ano de enfarte agudo do miocárdio, distribuídos aleatoriamente em dois grupos: grupo experimental (GE) e grupo de controlo (GC), ambos com 10 indivíduos. O programa de RCV no domicílio (constituído por 10 exercícios) teve a duração de 8 semanas, com uma frequência de 3 vezes por semana. Avaliou-se a frequência cardíaca (FC), tensão arterial e duplo produto basais e máximos; FC de recuperação; equivalentes metabólicos (METs); velocidade; inclinação; tempo de prova e de recuperação; índice cifótico; equilíbrio; e tempo em atividade moderada a vigorosa. Resultados: Ao fim de 8 semanas de exercício o GE aumentou significativamente os MET’s (p=0,001), tensão arterial sistólica máxima (p<0,001), duplo produto máximo (p<0,001) e tempo de prova (p=0,037) e diminuiu significativamente o tempo de recuperação (p<0,001), quando comparado com o GC. Conclusão: O programa de exercícios no domicílio promoveu uma melhoria na tolerância ao exercício e parece ter melhorado o equilíbrio, para a amostra em estudo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Backgound - In developed countries people are living longer and the incidence of chronic disease is increasing. Chronic disease and its treatments can have a negative impact on sexual functioning and sexual satisfaction. Aim of study - To explore and to compare sexual function and sexual satisfaction in people with stable chronic diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain a Ph.D. degree (Doutoramento) in Chemistry at the Instituto de Tecnologia Quimica e Biol6gica da Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2′-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented methodology favored Ab/Ag affinity and immunodetection of the antigen. The immunosensor design was evaluated by quartz-crystal microbalance with dissipation, atomic force microscopy, electrochemical impedance spectroscopy (EIS) and square-wave voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charge transfer resistance across the electrochemical set-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from glucose, urea and creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a novel use for the polymeric film, poly(o-aminophenol) (PAP) that was made responsive to a specific protein. This was achieved through templated electropolymerization of aminophenol (AP) in the presence of protein. The procedure involved adsorbing protein on the electrode surface and thereafter electroploymerizing the aminophenol. Proteins embedded at the outer surface of the polymeric film were digested by proteinase K and then washed away thereby creating vacant sites. The capacity of the template film to specifically rebind protein was tested with myoglobin (Myo), a cardiac biomarker for ischemia. The films acted as biomimetic artificial antibodies and were produced on a gold (Au) screen printed electrode (SPE), as a step towards disposable sensors to enable point-of-care applications. Raman spectroscopy was used to follow the surface modification of the Au-SPE. The ability of the material to rebind Myo was measured by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The devices displayed linear responses to Myo in EIS and SWV assays down to 4.0 and 3.5 μg/mL, respectively, with detection limits of 1.5 and 0.8 μg/mL. Good selectivity was observed in the presence of troponin T (TnT) and creatine kinase (CKMB) in SWV assays, and accurate results were obtained in applications to spiked serum. The sensor described in this work is a potential tool for screening Myo in point-of-care due to the simplicity of fabrication, disposability, short time response, low cost, good sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myoglobin (Mb) is among the cardiac biomarkers playing a major role in urgent diagnosis of cardiovascular diseases. Its monitoring in point-of-care is therefore fundamental. Pursuing this goal, a novel biomimetic ionophore for the potentiometric transduction of Mb is presented. It was synthesized by surface molecular imprinting (SMI) with the purpose of developing highly efficient sensor layers for near-stereochemical recognition of Mb. The template (Mb) was imprinted on a silane surface that was covalently attached to silica beads by means of self-assembled monolayers. First the silica was modified with an external layer of aldehyde groups. Then, Mb was attached by reaction with its amine groups (on the external surface) and subsequent formation of imine bonds. The vacant places surrounding Mb were filled by polymerization of the silane monomers 3-aminopropyltrimethoxysilane (APTMS) and propyltrimethoxysilane (PTMS). Finally, the template was removed by imine cleavage after treatment with oxalic acid. The results materials were finely dispersed in plasticized PVC selective membranes and used as ionophores in potentiometric transduction. The best analytical features were found in HEPES buffer of pH 4. Under this condition, the limits of detection were of 1.3 × 10−6 mol/L for a linear response after 8.0 × 10−7 mol/L with an anionic slope of −65.9 mV/decade. The imprinting effect was tested by preparing non-imprinted (NI) particles and employing these materials as ionophores. The resulting membranes showed no ability to detect Mb. Good selectivity was observed towards creatinine, sacarose, fructose, galactose, sodium glutamate, and alanine. The analytical application was conducted successfully and showed accurate and precise results.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a case report of a 43-year-old Caucasian male with end-stage renal disease being treated with hemodialysis and infective endocarditis in the aortic and tricuspid valves. The clinical presentation was dominated by neurologic impairment with cerebral embolism and hemorrhagic components. A thoracoabdominal computerized tomography scan revealed septic pulmonary embolus. The patient underwent empirical antibiotherapy with ceftriaxone, gentamicin and vancomycin, and the therapy was changed to flucloxacilin and gentamicin after the isolation of S. aureus in blood cultures. The multidisciplinary team determined that the patient should undergo valve replacement after the stabilization of the intracranial hemorrhage; however, on the 8th day of hospitalization, the patient entered cardiac arrest due to a massive septic pulmonary embolism and died. Despite the risk of aggravation of the hemorrhagic cerebral lesion, early surgical intervention should be considered in high-risk patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To characterize the epidemiology and risk factors for acute kidney injury (AKI) after pediatric cardiac surgery in our center, to determine its association with poor short-term outcomes, and to develop a logistic regression model that will predict the risk of AKI for the study population. Methods: This single-center, retrospective study included consecutive pediatric patients with congenital heart disease who underwent cardiac surgery between January 2010 and December 2012. Exclusion criteria were a history of renal disease, dialysis or renal transplantation. Results: Of the 325 patients included, median age three years (1 day---18 years), AKI occurred in 40 (12.3%) on the first postoperative day. Overall mortality was 13 (4%), nine of whom were in the AKI group. AKI was significantly associated with length of intensive care unit stay, length of mechanical ventilation and in-hospital death (p<0.01). Patients’ age and postoperative serum creatinine, blood urea nitrogen and lactate levels were included in the logistic regression model as predictor variables. The model accurately predicted AKI in this population, with a maximum combined sensitivity of 82.1% and specificity of 75.4%. Conclusions: AKI is common and is associated with poor short-term outcomes in this setting. Younger age and higher postoperative serum creatinine, blood urea nitrogen and lactate levels were powerful predictors of renal injury in this population. The proposed model could be a useful tool for risk stratification of these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Left ventricular reverse remodeling (LVRR), defined as reduction of end-diastolic and end-systolic dimensions and improvement of ejection fraction, is associated with the prognostic implications of cardiac resynchronization therapy (CRT). The time course of LVRR remains poorly characterized. Nevertheless, it has been suggested that it occurs ≤6 months after CRT. OBJECTIVE: To characterize the long-term echocardiographic and clinical evolution of patients with LVRR occurring >6 months after CRT and to identify predictors of a delayed LVRR response. METHODS: A total of 127 consecutive patients after successful CRT implantation were divided into three groups according to LVRR response: Group A, 19 patients (15%) with LVRR after >6 months (late LVRR); Group B, 58 patients (46%) with LVRR before 6 months (early LVRR); and Group C, 50 patients (39%) without LVRR during follow-up (no LVRR). RESULTS: The late LVRR group was older, more often had ischemic etiology and fewer patients were in NYHA class ≤II. Overall, group A presented LVRR between group B and C. This was also the case with the percentage of clinical response (68.4% vs. 94.8% vs. 38.3%, respectively, p<0.001), and hospital readmissions due to decompensated heart failure (31.6% vs. 12.1% vs. 57.1%, respectively, p<0.001). Ischemic etiology (OR 0.044; p=0.013) and NYHA functional class

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO - Com o aumento da esperança de vida e das doenças crónicas, cada vez se tem implantado mais cardioversores-desfibrilhadores (CDI) para prevenção de morte súbita. O aumento exponencial no número de implantes aumenta o número de seguimentos dos dispositivos, sobrecarregando os profissionais de saúde e comprometendo a qualidade dos serviços prestados. Segundo as recomendações internacionais, um CDI deverá ser vigiado a cada 3 meses, o que perfaz 4 consultas por ano/doente no mínimo, se não existirem episódios de “choques” ou “descompensações” clínicas, e mensalmente quando é atingido o indicador de substituição electiva do gerador. A evolução da tecnologia, de algoritmos, visualização de episódios e terapias requer recursos técnicos e humanos diferenciados e um gasto de tempo considerável no seguimento. Em países como os Estados Unidos da América, em que os doentes têm de percorrer distâncias muito grandes para aceder aos cuidados de saúde, tornou-se preemente a necessidade de um sistema de vigilância alternativo. Nesse sentido, e usando o conceito da telemedicina, foi criado o seguimento/monitorização à distância de dispositivos cardíacos. Este reduz os custos em consultas, deslocações e recursos humanos, uma vez que contempla apenas uma consulta presencial por ano. Por outro lado, aumenta a segurança do doente com a monitorização periódica e a criação de alarmes, permitindo uma assistência de qualidade e intervenção adequada imediata. Aproveitando as vantagens que este tipo de sistema de transmissão remota oferece, procedeu-se no meu serviço, à distribuição inicial de 62 comunicadores a doentes portadores de CDI´s ou com Ressincronizadores Cardíacos (TRC´s1). Apesar de ser considerada uma melhoria na qualidade dos serviços prestados, é também uma mudança importante na metodologia da consulta feita até aqui. Segundo vários autores, a avaliação da qualidade dos cuidados em saúde está intrinsecamente ligada ao grau de satisfação dos doentes com esses serviços, ou seja, à relação entre as suas expectativas e os resultados percebidos por eles, sendo considerado um importante indicador de qualidade dos serviços. Com este trabalho, pretende-se avaliar a percepção dos doentes face ao novo seguimento em termos de aceitação, satisfação, validade, segurança e confiança no novo sistema. Se este mantém os mesmos padrões de qualidade que o seguimento presencial. Trata-se de um estudo transversal com uma componente retrospectiva de avaliação da nova metodologia de consulta à distância. Para tal, foi elaborado um questionário, que foi aplicado a 40 doentes (17,5% do género feminino e 82,5% do género masculino; média de idades de 65 anos) que constituíram a amostra do estudo. Verificou-se uma média de 5 anos de tempo de implante do CDI. Dos dados obtidos, é de realçar que 70% dos inquiridos estão satisfeitos e 30% estão muito satisfeitos com esta nova metodologia de consulta e cerca 67,4% prefere a consulta à distância. Quando solicitados para comparar a qualidade do serviço prestado entre as duas consultas, 65% respondeu igual e 27,5% melhor. Todos os inquiridos responderam ter confiança e segurança com o sistema de consulta à distância. Cerca de 87,5% dos inquiridos vê-se mesmo a continuar com este tipo de consulta. Os resultados obtidos são bastante satisfatórios no que diz respeito à transição do modo como a consulta de CDI´s é feita. Reflectem também que a tecnologia não é necessariamente uma barreira no acesso aos profissionais de saúde, desde que suportada por algum contacto directo (telefone e através de uma consulta presencial por ano). 1 TRC – Terapia de Ressincronização Cardíaca