978 resultados para CHROMIUM


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of rice, maize, and sorghum raw material particle size in extruded dry dog food on the digestibility of nutrients and energy and the fecal concentration of fermentation products was investigated. Three diets with similar nutrient compositions were formulated, each with 1 starch source. Before incorporation into diets, the cereals were ground into 3 different particle sizes (approximately 300, 450, and 600 mu m); therefore, a total of 9 diets were in a 3 x 3 factorial arrangement (3 cereals and 3 particle sizes). Fifty-four beagle dogs (12.0 +/- 0.1 kg BW) were randomly assigned to the diets, with 6 dogs per diet. The digestibility was measured with the chromium oxide method. The data were evaluated with ANOVA considering the carbohydrate source, grinding effect, and interactions. The means were compared with the Tukey test and polynomial contrasts (P < 0.05). With the same grinding procedure, rice was reduced to smaller particles than other cereals. The cereal mean geometric diameter (MGD) was directly related to starch gelatini-zation (SG) during extrusion. For rice diets, the MGD and SG did not change nutrient digestibility (P > 0.05); only GE digestibility was reduced at the largest MGD (P < 0.01). For maize and sorghum diets, the total tract apparent nutrient digestibility was reduced for foods with greater MGD and less SG (P < 0.01). A linear reduction in nutrient digestibility according to cereal particle size was observed for sorghum (r(2) < 0.72; P < 0.01). Higher concentrations of fecal total shortchain fatty acids (SCFA) were observed for sorghum diets (P < 0.05) than for other diets. The rice diets led to the production of feces with less lactate (P < 0.05). The increase in raw material MGD did not influence fecal SCFA for rice diets, but for the dogs fed maize and sorghum foods, an increase in propionate and butyrate concentrations were observed as MGD increased (P < 0.05). In conclusion, for dogs fed different particle sizes of the cereal starches in the extruded diets, the digestibility and fecal characteristics were affected, and this effect was ingredient dependent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Inoue procedure is used to study the influence of Cr and Cu elements, jointly or individually, on the matrix decomposition of quenched Al-Zn-Mg alloys. The addition of copper and copper with chromium does not significantly change the limits of the temperatures of formation of Guinier-Preston zone and the range of the matrix decomposition. The control of the vacancy concentration in the alloys by different heat treatments and the addition of certain elements such as copper and chromium seems to play an important role in the nucleation rate and the kinetics of phase transformations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recasting process influence upon corrosion behavior of Co-Cr-Mo dental alloy in simulated physiological serum has been investigated using chemical and electrochemical techniques. Recast Co-Cr-Mo alloy by induction (IND) or by blowtorch (FLAME) has exhibited similar dendritic structures. Both IND and FLAME alloys have presented good corrosion resistance in physiological serum. Passivation process provides this corrosion resistance. Codissolution makes this process difficult. Passive films, formed on these alloys, have been analyzed as a dual layer consisting of an inner barrier and an outer porous layer. Passive film protective characteristics are higher in FLAME than in IND alloy. On this last alloy, the passive film is more porous due to a higher Codissolution. ©Carl Hanser Verlag, München.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several alloys have been used for prosthodontics restorations in the last years. These alloys have a number of metals that include gold, palladium, silver, nickel, cobalt, chromium and titanium and they are used in oral cavity undergo several corrosion. Corrosion can lead to poor esthetics, compromise of physical properties, or increased biological irritation. The objective of this study was evaluated corrosion resistance of two alloys Ni-Cr and Ni-Cr-Ti in three types of mouthwashes with different active ingredients: 0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride, 0.05% sodium fluoride + 0.03% triclosan (with fluor) and 0.12% chlorohexidine digluconate. The potentiodynamic curves were performed by means of an EG&G PAR 283 potentiostat/galvanostat. The counter electrode was a platinum wire and reference electrode was an Ag/AgCl, KCl saturated. Before each experiment, working electrodes were mechanically polished with 600 and 1200 grade papers, rinsed with distilled water and dried in air. All experiments were carried out at 37.0oC in conventional three-compartment double wall glass cell containing mouthwashes. The microstructures of two alloys were observed in optical microscopy. Analysis of curves showed that Ni-Cr alloy was less reactive in the presence of 0.12% chlorohexidine digluconate while Ni-Cr-Ti alloy was more sensitive for others two types of mouthwashes (0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride  and 0.05% sodium fluoride + 0.03% triclosan). This occurred probably due presence of titanium in this alloy. Microstructural analysis reveals the presence of dendritic and eutectic microstructures for NiCr and Ni-Cr-Ti, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: As a new alternative in the complementary treatment lasers teem different systems were employed in the decontamination of dental surfaces implants however, some systems have caused significant changes in its surface. Purpose: Analyze by Scanning Electron Microscopy (SEM) the effects of laser irradiation of Er,Cr: YSGG on different surfaces of titanium. Material and method: Study of 20 titanium discs, and 10 Machined Surface (MS) and 10 surfaces treated with acid (AC). The 10 discs with the same treatment were divided into two groups with five units each, the irradiation was performed in powers of 1 W and 2 W. Result: Showed that the irradiation with 1 W of power resulted in no significant morphological changes in the MS-irradiated compared to non-irradiated surfaces. In MS surfaces, minor changes were observed in the increase of 1000× when compared to non-irradiated surface. With 2 W of power, there were no significant morphological changes in the MS, compared to non-irradiated areas. In AC some changes were observed in the increase of X 1000, showing areas of wear suggestive of treatment and some areas with melting point. Conclusion: Considering the results and the parameters used in this study it was concluded that the Er, Cr: YSGG irradiation can be used for the machined surfaces of implants, but in acid-treated surfaces irradiation parameters should be more controlled.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)