904 resultados para Biomechanical tests
Resumo:
The oral rehabilitation by dental implants in patients with diabetes remains a controversial issue. The aim of this study was to evaluate the influence of diabetes mellitus and insulin therapy on the bone healing around dental implants using torque removal. Twenty-seven rabbits were randomly divided into 3 groups with 9 animals each: control (C) group, induced diabetic (D) group, and insulin-treated diabetic (ITD) group (10 U/day). After 1 week, one implant was inserted at the tibial metaphysis of the animals. The glucose levels were periodically evaluated through the glucose-oxidase enzymatic method. The animals were killed at 4, 8, and 12 weeks after surgery and the biomechanical test was performed using a torque manometer. Statistically significant differences regarding the removal torque of the implant could not be found at 4 weeks (P = 0.2) among groups. Group C showed statistically higher values than groups D and ITD at the experimental periods of 8 (P = 0.0001 and P = 0.0002, respectively) and 12 weeks (P = 0.0053 and P = 0.001, respectively). There were no statistical differences between D and ITD groups in any of the experimental periods. Diabetes mellitus has negatively influenced the mechanical retention of implants placed at the tibial metaphysis of rabbits. Therapy with insulin did not induce any changes.
Resumo:
Aim. Diclofenac sodium is a non-steroidal anti-inflammatory drug commonly used to attenuate painful inflammatory reactions in surgery. However, it may delay healing in the skin and gastrointestinal tract. The aim of this study was to evaluate the influence of Diclofenac in vascular healing. Methods. Ninety rabbits had their carotid arteries sectioned and reconstructed by end-to-end anastomosis with interrupted sutures. The animals were randomly allocated into 3 groups of 30 each and treated by intramuscular route with saline (control), 5 mg/kg/day of diclofenac sodium (DS-5), and 10 mg/kg/day of diclofenac sodium (DS-10). Treatment began on the day of surgery and lasted 4 days. Angiography, biomechanical properties (failure load, failure elongation, yield point, yield point elongation, and stiffness were obtained from the load/elongation curve), macroscopic and histological examinations (hematoxylin-eosin, Masson, Calleja, Picrossirius-red), and scanning electron microscopy were studied in both arteries on the 3rd and 15th postoperative days. Results. No significant differences in biomechanical properties were observed either in the 3 groups or the experimental times. The carotid artery healing process was similar in the 3 groups. Conclusion. Diclofenac sodium did not cause alterations nor delayed carotid artery healing.
Resumo:
We discuss phenomenological tests for the frozen infrared behavior of the running coupling constant and gluon propagators found in some solutions of Schwinger-Dyson equations of the gluonic sector of QCD. We verify that several observables can be used in order to select the different expressions of αs found in the literature. We test the effect of the nonperturbative coupling in the τ-lepton decay rate into nonstrange hadrons, in the ρ vector meson helicity density matrix that are produced in the χc2 → ρρ decay, in the photon to pion transition form factor, and compute the cross-sections for elastic proton-proton scattering and exclusive ρ production in deep inelastic scattering. These quantities depend on the infrared behavior of the coupling constant at different levels, we discuss the reasons for this dependence and argue that the existent and future data can be used to test the approximations performed to solve the Schwinger-Dyson equations and they already seem to select one specific infrared behavior of the coupling.
Resumo:
This study investigated the oblique ligament mechanical contribution to the medial collateral ligament of the canine elbow joint. Fifteen dogs were used for the study of the failure load, displacement, and energy absorption of the medial collateral and oblique ligaments of the canine elbow joint, associate and separately in the joint. Medial collateral ligament failure load and energy absorption were significantly higher in relation to the isolated oblique ligament. When the ligaments were associated in the joint, they presented an increment in failure load, displacement and energy absorption in relation to the ligaments analyzed separately. It was concluded, therefore, that the oblique ligament could have an important paper in the stability of the canine elbow joint, as it favors the medial collateral ligament resistance to the tensile load, one of the main stabilizer of the elbow joint.
Resumo:
Aim: To examine the genotoxicity and cytotoxicity of regular and white mineral trioxide aggregate (MTA) ex vivo by the single-cell gel (comet) assay and trypan blue exclusion test, respectively. Methodology: Aliquots of 1 × 10 4 Chinese hamster ovary cells were incubated at 37°C for 3 h with grey and white forms of MTA at final concentrations ranging from 1 to 1000 μg mL -1. The negative control group was treated with vehicle control phosphate buffer solution for 3 h at 37°C and the positive control group was treated with methyl metasulfonate (at 1 μg mL -1) for 1 h at 37°C. After incubation, the cells were centrifuged at 180 g for 5 min and washed twice with fresh medium and resuspended with fresh medium. Each individual treatment was repeated three times consecutively to ensure reproducibility. Parameters from single-cell gel (comet) and cytotoxicity assays were assessed by the Kruskal-Wallis nonparametric test. Results: Neither compounds produced genotoxic effects with respect to the single-cell gel (comet) assay in all concentrations evaluated. In the same way, the dose-response relationships of all compounds tested at concentrations ranging from 1 to 1000 μg mL -1 on cell viability assessed by the trypan blue assay displayed no statistically significant differences (P > 0.05) for either endodontic material. Conclusions: Regular (grey) and white MTA are not genotoxins and do not induce cellular death. © 2006 International Endodontic Journal.
Resumo:
A large portion of Brazil is covered with tropical soils but literature about dynamic parameters of these soils is very limited. SCPT and cross-hole tests were carried out at an experimental research site inland in the state of São Paulo, Brazil. Shear wave velocities (VS) determined based on both tests are presented and compared. A good agreement was observed between both test results and the differences can be associated with soil variability, which was very sensitive to CPT tests. It was also observed that Go/q c ratio determined based on SCPT appears to be an interesting technique to help identify tropical soils. Copyright ASCE 2006.
Resumo:
Aging is associated with decline in muscle mass and strength and reduced bone density. Age-related bone loss is a primary factor in osteoporosis and all individuals are potential candidates for osteoporosis because bone loss with aging occurs in men and women, but less studied in men. To examine the appropriateness of hindlimb elevation, by tail suspension as a model for diminished mechanical loading, and to determine the influence of age on bone responsiveness to skeletal unloading, we use dual X ray absorptiometry (DXA) and digital radiographic images to analyze the response of the femur from mature rats to biomechanical loads. Femurs from male Wistar rats (9-mo-old) were scanned using DXA and DIGORA and measures obtained in ephipyseal and diaphyseal regions of interest. The mechanical testing was divided into compression load to fracture the head and a three-point bending load to fracture the femur middiaphysis. In femoral epiphysis from hindlimb unload (HU), animals presented significant differences between mineral bone content and density assessed by DXA. Detailed regions of femoral epiphysis (head, throcanteric fossa, throcanter and metaphysis) presented significant lower values from radiographic density. Only compressive load necessary to fracture the femoral head neck was also significantly diminished in HU animals. Disuse induced, as in elderly patients, deterioration of the trabecular bone architecture with critical effect on bone fragility. Rats with 21 days of hindlimb unloading can simulate disuse, suggesting that certain sub-regions of their aging bones are more susceptible to fracture, while other, i.e. diaphyses, are not.
Resumo:
Purpose - The purpose of this paper is to present designs for an accelerated life test (ALT). Design/methodology/approach - Bayesian methods and simulation Monte Carlo Markov Chain (MCMC) methods were used. Findings - In the paper a Bayesian method based on MCMC for ALT under EW distribution (for life time) and Arrhenius models (relating the stress variable and parameters) was proposed. The paper can conclude that it is a reasonable alternative to the classical statistical methods since the implementation of the proposed method is simple, not requiring advanced computational understanding and inferences on the parameters can be made easily. By the predictive density of a future observation, a procedure was developed to plan ALT and also to verify if the conformance fraction of the manufactured process reaches some desired level of quality. This procedure is useful for statistical process control in many industrial applications. Research limitations/implications - The results may be applied in a semiconductor manufacturer. Originality/value - The Exponentiated-Weibull-Arrhenius model has never before been used to plan an ALT. © Emerald Group Publishing Limited.
Resumo:
Classification and standardization of the sawn wood is a usual activity, developed by countries that come as great consumers of this material. Brazil does not practice the classification of sawn wood. This work had the main objective of evaluating the sensibility of most common non-destructive tests in the classification of dimension lumber from fast grown Eucalyptus plantation. Wood was obtained from genetic material cultivated at Minas Gerais State, Brazil. 296 beams of structural dimensions (6 cm × 12 cm × 280 cm) from 10 different clones of Eucalyptus were sampled. Beams were non-destructively (stress wave, ultrasound and transverse vibration) and destructively (static bending and compression parallel to grain) tested. Non-destructive results showed sensibility in the classification of structural dimension lumber, being possible to establish wave velocity intervals that attend to the main strength classes reported by Wooden Structures Brazilian Code.
Resumo:
The use of piezocone tests with a slot filter filled with automotive grease for site characterization of tropical soils is assessed. Laboratory tests using the slot filter filled with automotive grease as well as the conventional porous piezo-element saturated with glycerin were carried out to evaluate the pore pressure (u 2) transducer response. CPTu tests using piezo-elements saturated with glycerin and the slot filter filled with grease were pushed side by side in different research sites in Brazil. Estimates of mechanical and hydraulic soil parameters were made based on pore pressure dissipation curves from using both techniques. Laboratory test results indicate that the pore pressure response using the slot filter with grease was delayed when compared to the piezo-element saturated with glycerin, since grease has a higher viscosity. For tropical soils, the records of u2 in piezocone tests using slot filter with grease presented larger peaks than with porous element saturated with glycerin. Records of u2 using the slot filter above the groundwater table suggest the increase of the degree of saturation in unsaturated zone, where porous filter can be desaturated by suction. The slot filter can be used to help the interpretation of the soil profile with deep groundwater level as well as to help detecting its position for some studied soils. The results shown high repeatability for all study sites. This technique is much easier to handle, especially for tropical soils, where the groundwater table is usually deep and pre-drilling is expensive and time consuming. © 2009 IOS Press.
SEM-EDS and biomechanical evaluation of implants with different surface treatments: An initial study
Resumo:
Aim: Alterations in implant surfaces can affect periimplant bone formation and shorten the healing time. The goal of the present study was a comparative scanning electron microscopy (SEM)/energy dispersive spectrometry (EDS) and biomechanical evaluation of implants subjected to different surface treatments. Materials and Methods: Four implant surfaces were analyzed in the present study: machined commercial implants (TU); porous-surfaced commercial implants blasted with Al2O3 microspheres and acid-etched (TJA); laser beam-irradiated experimental implants (Laser) and laser beam-irradiated experimental implants with hydroxyapatite coating (HA). One sample for each surface underwent pre-surgery SEM/EDS analysis. Thirty-two implants (8 for each surface treatment) were then inserted into the tibia of 4 rabbits. After 8 weeks, the animals were euthanized and the implants retrieved by reverse torque and processed for post-surgery SEM/EDS analysis. Results: HA implants presented higher removal torque values when compared to Laser, TJA and TU groups. Post-surgery SEM micrographs clearly showed bone formation on all the examined surfaces; however, in the TU group bone covered only some areas of the implant surface, while in TJA, Laser and HA groups the entire implant surfaces were overlaid by newly formed bone. EDS analysis supported the results obtained by SEM and removal torque, showing that concentration of Ca and P increased from TU to TJA, Laser and HA implants. Conclusions: Implants with surfaces modified by laser beam with or without apatite coating showed more promising results.
Resumo:
The purpose of the present study was to evaluate, using a biomechanical test, the force needed to remove implants with surface modification by laser (Nd:YAG) in comparison with implants with machined surfaces. Twenty-four rabbits received one implant with each surface treatment in the tibia, machined surface (MS) and laser-modified surface (LMS). After 4, 8 and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition and roughness. The average removal torque in each period was 23.28, 24.0 and 33.85 Ncm for MS, and 33.0, 39.87 and 54.57 Ncm for LMS, respectively. The difference between the surfaces in all periods of evaluation was statistically significant (p < 0.05). Surface characterization showed that a deep and regular topography was provided by the laser conditioning, with a great quantity of oxygen ions when compared to the MS. The surface micro-topography analysis showed a statistical difference (p < 0.01) between the roughness of the LMS (R a = 1.38 ± 0.23 μm) when compared to that of the MS (R a = 0.33 ± 0.06 μm). Based on these results, it was possible to conclude that the LMS implants' physical-chemical properties increased bone-implant interaction when compared to the MS implants. © 2009 Sociedade Brasileira de Pesquisa Odontológica.
Resumo:
Objective. The aim of this study was to verify the possibility of lactate minimum (LM) determination during a walking test and the validity of such LM protocol on predicting the maximal lactate steady-state (MLSS) intensity. Design. Eleven healthy subjects (24.2 ± 4.5 yr; 74.3 ± 7.7 kg; 176.9 ± 4.1 cm) performed LM tests on a treadmill, consisting of walking at 5.5 km h -1 and with 20-22% of inclination until voluntary exhaustion to induce metabolic acidosis. After 7 minutes of recovery the participants performed an incremental test starting at 7% incline with increments of 2% at each 3 minutes until exhaustion. A polynomial modeling approach (LMp) and a visual inspection (LMv) were used to identify the LM as the exercise intensity associated to the lowest [bLac] during the test. Participants also underwent to 24 constant intensity tests of 30 minutes to determine the MLSS intensity. Results. There were no differences among LMv (12.6 ± 1.7 %), LMp (13.1 ± 1.5 %), and MLSS (13.6 ± 2.1 %) and the Bland and Altman plots evidenced acceptable agreement between them. Conclusion. It was possible to identify the LM during walking tests with intensity imposed by treadmill inclination, and it seemed to be valid on identifying the exercise intensity associated to the MLSS. Copyright © 2012 Guilherme Morais Puga et al.
Resumo:
Some ant species cause severe ecological and health impact in urban areas. Many attempts have been tested to control such species, although they do not always succeed. Biological control is an alternative to chemical control and has gained great prominence in research, and fungi and nematodes are among the successful organisms controlling insects. This study aimed to clarify some questions regarding the biological control of ants. Invasive ant species in Brazil had their nests evaluated for the presence of entomopathogens. Isolated entomopathogens were later applied in colonies of Monomorium floricola under laboratory conditions to evaluate their effectiveness and the behavior of the ant colonies after treatment. The entomopathogenic nematodes Heterorhabditis sp. and Steinernema sp. and the fungi Beauveria bassiana, Metarhizium anisopliae, and Paecilomyces sp. were isolated from the invasive ant nests. M. floricola colonies treated with Steinernema sp. and Heterorhabditis sp. showed a higher mortality of workers than control. The fungus Beauveria bassiana caused higher mortality of M. floricola workers. However, no colony reduction or elimination was observed in any treatment. The defensive behaviors of ants, such as grooming behavior and colony budding, must be considered when using fungi and nematodes for biological control of ants. Copyright © 2012 Maria Fernanda Miori de Zarzuela et al.