923 resultados para Array forms
Resumo:
In this paper, we present a novel technique for the removal of astigmatism in submillimeter-wave optical systems through employment of a specific combination of so-called astigmatic off-axis reflectors. This technique treats an orthogonally astigmatic beam using skew Gaussian beam analysis, from which an anastigmatic imaging network is derived. The resultant beam is considered truly stigmatic, with all Gaussian beam parameters in the orthogonal directions being matched. This is thus considered an improvement over previous techniques wherein a beam corrected for astigmatism has only the orthogonal beam amplitude radii matched, with phase shift and phase radius of curvature not considered. This technique is computationally efficient, negating the requirement for computationally intensive numerical analysis of shaped reflector surfaces. The required optical surfaces are also relatively simple to implement compared to such numerically optimized shaped surfaces. This technique is implemented in this work as part of the complete optics train for the STEAMR antenna. The STEAMR instrument is envisaged as a mutli-beam limb sounding instrument operating at submillimeter wavelengths. The antenna optics arrangement for this instrument uses multiple off-axis reflectors to control the incident radiation and couple them to their corresponding receiver feeds. An anastigmatic imaging network is successfully implemented into an optical model of this antenna, and the resultant design ensures optimal imaging of the beams to the corresponding feed horns. This example also addresses the challenges of imaging in multi-beam antenna systems.
Resumo:
For clinical optoacoustic imaging, linear probes are preferably used because they allow versatile imaging of the human body with real-time display and free-hand probe guidance. The two-dimensional (2-D) optoacoustic image obtained with this type of probe is generally interpreted as a 2-D cross-section of the tissue just as is common in echo ultrasound. We demonstrate in three-dimensional simulations, phantom experiments, and in vivo mouse experiments that for vascular imaging this interpretation is often inaccurate. The cylindrical blood vessels emit anisotropic acoustic transients, which can be sensitively detected only if the direction of acoustic radiation coincides with the probe aperture. Our results reveal for this reason that the signal amplitude of different blood vessels may differ even if the vessels have the same diameter and initial pressure distribution but different orientation relative to the imaging plane. This has important implications for the image interpretation, for the probe guidance technique, and especially in cases when a quantitative reconstruction of the optical tissue properties is required.
Resumo:
A CE system featuring an array of 16 contactless conductivity detectors was constructed. The detectors were arranged along 70 cm length of a capillary with 100 cm total length and allow the monitoring of separation processes. As the detectors cannot be accommodated on a conventional commercial instrument, a purpose built set-up employing a sequential injection manifold had to be employed for automation of the fluid handling. Conductivity measurements can be considered universal for electrophoresis and thus any changes in ionic composition can be monitored. The progress of the separation of Na(+) and K(+) is demonstrated. The potential of the system to the study of processes in CZE is shown in two examples. The first demonstrates the differences in the developments of peaks originating from a sample plug with a purely aqueous background to that of a plug containing the analyte ions in the buffer. The second example visualizes the opposite migration of cations and anions from a sample plug that had been placed in the middle of the capillary.
Resumo:
[James A. Huie]
Resumo:
We report about a lung-on-chip array that mimics the pulmonary parenchymal environment, including the thin, alveolar barrier and the three-dimensional cyclic strain induced by the breathing movements. A micro-diaphragm used to stretch the alveolar barrier is inspired by the in-vivo diaphragm, the main muscle responsible for inspiration. The design of this device aims not only at best reproducing the in-vivo conditions found in the lung parenchyma, but also at making its handling easy and robust. An innovative concept, based on the reversible bonding of the device, is presented that enables to accurately control the concentration of cells cultured on the membrane by easily accessing both sides of the membranes. The functionality of the alveolar barrier could be restored by co-culturing epithelial and endothelial cells that formed tight monolayers on each side of a thin, porous and stretchable membrane. We showed that cyclic stretch significantly affects the permeability properties of epithelial cell layers. Furthermore, we could also demonstrate that the strain influences the metabolic activity and the cytokine secretion of primary human pulmonary alveolar epithelial cells obtained from patients. These results demonstrate the potential of this device and confirm the importance of the mechanical strain induced by the breathing in pulmonary research.
Resumo:
FcαRI (CD89), the human Fc receptor for IgA, is highly expressed on neutrophil granulocytes. In this study, we show that FcαRI induces different forms of neutrophil death, depending on the inflammatory microenvironment. The susceptibility of inflammatory neutrophils from sepsis or rheumatoid arthritis toward death induced by specific mAb, or soluble IgA at high concentrations, was enhanced. Although unstimulated cells experienced apoptosis following anti-FcαRI mAb stimulation, preactivation with cytokines or TLR agonists in vitro enhanced FcαRI-mediated death by additional recruitment of caspase-independent pathways, but this required PI3K class IA and MAPK signaling. Transmission electron microscopy of FcαRI-stimulated cells revealed cytoplasmic changes with vacuolization and mitochondrial swelling, nuclear condensation, and sustained plasma membrane. Coculture experiments with macrophages revealed anti-inflammatory effects of the partially caspase-independent death of primed cells following FcαRI engagement. Our data suggest that FcαRI has the ability to regulate neutrophil viability and to induce different forms of neutrophils depending on the inflammatory microenvironment and specific characteristics of the ligand-receptor interactions. Furthermore, these findings have potential implications for FcαRI-targeted strategies to treat neutrophil-associated inflammatory diseases.
Resumo:
An inherited polyneuropathy (PN) observed in Leonberger dogs has clinical similarities to a genetically heterogeneous group of peripheral neuropathies termed Charcot-Marie-Tooth (CMT) disease in humans. The Leonberger disorder is a severe, juvenile-onset, chronic, progressive, and mixed PN, characterized by exercise intolerance, gait abnormalities and muscle atrophy of the pelvic limbs, as well as inspiratory stridor and dyspnea. We mapped a PN locus in Leonbergers to a 250 kb region on canine chromosome 16 (Praw = 1.16×10-10, Pgenome, corrected = 0.006) utilizing a high-density SNP array. Within this interval is the ARHGEF10 gene, a member of the rho family of GTPases known to be involved in neuronal growth and axonal migration, and implicated in human hypomyelination. ARHGEF10 sequencing identified a 10 bp deletion in affected dogs that removes four nucleotides from the 3'-end of exon 17 and six nucleotides from the 5'-end of intron 17 (c.1955_1958+6delCACGGTGAGC). This eliminates the 3'-splice junction of exon 17, creates an alternate splice site immediately downstream in which the processed mRNA contains a frame shift, and generates a premature stop codon predicted to truncate approximately 50% of the protein. Homozygosity for the deletion was highly associated with the severe juvenile-onset PN phenotype in both Leonberger and Saint Bernard dogs. The overall clinical picture of PN in these breeds, and the effects of sex and heterozygosity of the ARHGEF10 deletion, are less clear due to the likely presence of other forms of PN with variable ages of onset and severity of clinical signs. This is the first documented severe polyneuropathy associated with a mutation in ARHGEF10 in any species.
Resumo:
Research question: International and national sport federations as well as their member organisations (usually sport clubs) are key actors within the sport system and have a wide range of relationships outside the sport system (e.g. with the state, sponsors, and the media). They are currently facing major challenges such as growing competition in top-level sports, democratisation of sports with “sports for all” and sports as the answer to social problems (integration, education, health, unemployment, etc.). In this context, professionalising sport organisations seems to be an appropriate strategy to face these challenges and solve current problems. We define the professionalisation of sport organisations as an organisational process of transformation leading towards organisational rationalisation, efficiency and business-like management. This has led to a profound organisational change, particularly within sport federations, characterised by the strengthening of institutional management (managerialism) and the implementation of efficiency-based management instruments and paid staff. Research methods: The goal of this article is to review the international literature and establish a global understanding of and theoretical framework for how sport organisations professionalise and what consequences this may have. Results and Findings: Our multi-level approach based on the social theory of action integrates the current concepts for analysing professionalisation in sport federations. We specify the framework for the following research perspectives: (1) forms, (2) causes and (3) consequences, and discuss the reciprocal relations between sport federations and their member organisations in this context. Implications: Finally, we derive general methodological consequences for the investigation of professionalisation processes in sport organisations.
Resumo:
Gender-fair language, that is, referring to men and women with symmetrical linguistic forms, has been found to promote gender equality, but it is largely unknown which factors help make gender-fair forms more common in everyday life. Two studies examined whether speakers of German used more gender-fair forms after reading a text with gender-fair wording (vs. masculine generics vs. no personal nouns vs. another topic). Both studies showed consistently that women used more gender-fair forms after reading the gender-fair text than the other texts, whereas men did not. Men employed more gender-fair forms only after being made aware of these forms (Study 2). To conclude, merely reading gender-fair texts enhances women’s inclination to use gender-fair language, whereas men need to be made aware of this type of language use. Both studies highlight the importance of using gender-fair language frequently and consistently in everyday life.
Resumo:
Loss of function of the urea cycle enzyme argininosuccinate lyase (ASL) is caused by mutations in the ASL gene leading to ASL deficiency (ASLD). ASLD has a broad clinical spectrum ranging from life-threatening severe neonatal to asymptomatic forms. Different levels of residual ASL activity probably contribute to the phenotypic variability but reliable expression systems allowing clinically useful conclusions are not yet available. In order to define the molecular characteristics underlying the phenotypic variability, we investigated all ASL mutations that were hitherto identified in patients with late onset or mild clinical and biochemical courses by ASL expression in human embryonic kidney 293 T cells. We found residual activities >3 % of ASL wild type (WT) in nine of 11 ASL mutations. Six ASL mutations (p.Arg95Cys, p.Ile100Thr, p.Val178Met, p.Glu189Gly, p.Val335Leu, and p.Arg379Cys) with residual activities ≥16 % of ASL WT showed no significant or less than twofold reduced Km values, but displayed thermal instability. Computational structural analysis supported the biochemical findings by revealing multiple effects including protein instability, disruption of ionic interactions and hydrogen bonds between residues in the monomeric form of the protein, and disruption of contacts between adjacent monomeric units in the ASL tetramer. These findings suggest that the clinical and biochemical course in variant forms of ASLD is associated with relevant residual levels of ASL activity as well as instability of mutant ASL proteins. Since about 30 % of known ASLD genotypes are affected by mutations studied here, ASLD should be considered as a candidate for chaperone treatment to improve mutant protein stability.
Resumo:
HYPOTHESIS To evaluate the feasibility and the results of insertion of two types of electrode arrays in a robotically assisted surgical approach. BACKGROUND Recent publications demonstrated that robot-assisted surgery allows the implantation of free-fitting electrode arrays through a cochleostomy drilled via a narrow bony tunnel (DCA). We investigated if electrode arrays from different manufacturers could be used with this approach. METHODS Cone-beam CT imaging was performed on fivecadaveric heads after placement of fiducial screws. Relevant anatomical structures were segmented and the DCA trajectory, including the position of the cochleostomy, was defined to target the center of the scala tympani while reducing the risk of lesions to the facial nerve. Med-El Flex 28 and Cochlear CI422 electrodes were implanted on both sides, and their position was verified by cone-beam CT. Finally, temporal bones were dissected to assess the occurrence of damage to anatomical structures during DCA drilling. RESULTS The cochleostomy site was directed in the scala tympani in 9 of 10 cases. The insertion of electrode arrays was successful in 19 of 20 attempts. No facial nerve damage was observed. The average difference between the planned and the postoperative trajectory was 0.17 ± 0.19 mm at the level of the facial nerve. The average depth of insertion was 305.5 ± 55.2 and 243 ± 32.1 degrees with Med-El and Cochlear arrays, respectively. CONCLUSIONS Robot-assisted surgery is a reliable tool to allow cochlear implantation through a cochleostomy. Technical solutions must be developed to improve the electrode array insertion using this approach.
Resumo:
OBJECTIVE To compare the in vitro effects of hypertonic solutions and colloids to saline on coagulation in dogs. DESIGN In vitro experimental study. SETTING Veterinary teaching hospital. ANIMALS Twenty-one adult dogs. INTERVENTIONS Blood samples were diluted with saline, 7.2% hypertonic saline solution with 6% hydroxyethylstarch with an average molecular weight of 200 kDa and a molar substitution of 0.4 (HH), 7.2% hypertonic saline (HTS), hydroxyethyl starch (HES) 130/0.4 or hydroxyethyl starch 600/0.75 at ratios of 1:22 and 1:9, and with saline and HES at a ratio of 1:3. MEASUREMENTS AND MAIN RESULTS Whole blood coagulation was analyzed using rotational thromboelastometry (extrinsic thromboelastometry-cloting time (ExTEM-CT), maximal clot firmness (MCF) and clot formation time (CFT) and fibrinogen function TEM-CT (FibTEM-CT) and MCF) and platelet function was analyzed using a platelet function analyzer (closure time, CTPFA ). All parameters measured were impaired by saline dilution. The CTPFA was prolonged by 7.2% hypertonic saline solution with 6% hydroxyethylstarch with an average molecular weight of 200 kDa and a molar substitution of 0.4 (HH) and HTS but not by HES solutions. At clinical dilutions equivalent to those generally administered for shock (saline 1:3, HES 1:9, and hypertonic solutions 1:22), CTPFA was more prolonged by HH and HTS than other solutions but more by saline than HES. No difference was found between the HES solutions or the hypertonic solutions. ExTEM-CFT and MCF were impaired by HH and HTS but only mildly by HES solutions. At clinically relevant dilutions, no difference was found in ExTEM-CFT between HTS and saline or in ExTEM-MCF between HH and saline. No consistent difference was found between the 2 HES solutions but HH impaired ExTEM-CFT and MCF more than HTS. At high dilutions, FibTEM-CT and -MCF and ExTEM-CT were impaired by HES. CONCLUSIONS Hypertonic solutions affect platelet function and whole blood coagulation to a greater extent than saline and HES. At clinically relevant dilutions, only CTPFA was markedly more affected by hypertonic solutions than by saline. At high dilutions, HES significantly affects coagulation but to no greater extent than saline at clinically relevant dilutions.