873 resultados para Apertureless aplanatic lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The kinin family are a group of bioactive peptides that are closely involved in the modulation of vascular inflammation and local injury. We have demonstrated here, for the first time, a link between kinin activity and contact lens wear. Protein extracts from daily and extended wear etafilcon A, Group IV, Acuvue lenses (Vistakon), were analysed by counter immunoelectrophoresis. In this way, kinin activity associated with contact lens wear was detected. High molecular weight kininogen was used as the marker protein. In contrast, no kinin activity was detected in the non-lens wearing normal eye. © 2002 British Contact Lens Association. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many factors can be, and have been, attributed to the appearance of complications in lens wear, but the greatest is associated with deposition. Reduced acuity, irritation and inflammatory responses are often referred to as adverse reactions arising as a result of deposition. In this study, particular attention was paid to the potential role of adsorbed proteins in activating, mediating and/or stimulating a host immune response, i.e., the hypothesis that the adsorption of certain proteins from the tears and ocular surfaces may actively affect successful lens wear. In particular, the purpose of this study was to investigate the presence of a group of proteins previously undiscovered in the ocular environment. The intention was to target a family of proteins/glycoproteins that have become prominent recently in a variety of inflammatory responses and disorders at many other mucosal associated sites around the body, e.g. in nasal rhinitis and in joint inflammation. The protein cascade in question is the kinin family of inflammatory mediators. The aim was to investigate their presence in the ocular environment, specifically in relation to contact lens wear, and consequently assess the implications of their discovery. High molecular weight kininogen (HMWK), with its central role in kinin responses, was investigated initially as the marker of kinin activity, with subsequent members examined thereafter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication of submicron-height sine-like relief of a trifocal diffractive zone plate using a nanoimprinting technique is studied. The zone plate is intended for use in combined trifocal diffractive-refractive lenses and provides the possibility to form trifocal intraocular lenses with predetermined light intensity distribution between foci. The optical properties of the designed zone plate having the optical powers 3 D, 0, -3D in the three main diffraction orders are theoretically and experimentally investigated. The results of the theoretical investigations are in good agreement with experimental measurements. The effects of the pupil size (lens diameter) as well as the wavelength-dependent behavior of the zone plate are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To examine the optimum time at which fluorescein patterns of gas permeable lenses (GPs) should be evaluated. METHODS: Aligned, 0.2mm steep and 0.2mm flat GPs were fitted to 17 patients (aged 20.6±1.1 years, 10 male). Fluorescein was applied to their upper temporal bulbar conjunctiva with a moistened fluorescein strip. Digital slit lamp images (CSO, Italy) at 10× magnification of the fluorescein pattern viewed with blue light through a yellow filter were captured every 15s. Fluorescein intensity in central, mid peripheral and edge regions of the superior, inferior, temporal and nasal quadrants of the lens were graded subjectively using a +2 to -2 scale and using ImageJ software on the simultaneously captured images. RESULTS: Subjectively graded and objectively image analysed fluorescein intensity changed with time (p<0.001), lens region (centre, mid-periphery and edge: p<0.05) and there was interaction between lens region with lens fit (p<0.001). For edge band width, there was a significant effect of time (F=118.503, p<0.001) and lens fit (F=5.1249, p=0.012). The expected alignment, flat and steep fitting patterns could be seen from approximately after 30 to 180s subjectively and 15 to 105s in captured images. CONCLUSION: Although the stability of fluorescein intensity can start to decline in as little as 45s post fluorescein instillation, the diagnostic pattern of alignment, steep or flat fit is seen in each meridian by subjective observation from about 30s to 3min indicating this is the most appropriate time window to evaluate GP lenses in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To appraise history and symptom taking for contact lens consultations, to determine current practice and to make recommendations for best practice. Method: The peer reviewed academic literature was reviewed and the results informed a survey completed by 256 eye care practitioners (ECPs) on their current practice and influences. Results: The last eye-test date, last contact lens aftercare (for existing wearers) and reason for visit are key questions for most ECPs. Detailed use of contact lens questions are more commonly applied in aftercares than when refitting patients who have previously discontinued wear (87% vs 56% use), whereas questions on ocular and general history, medication and lifestyle were generally more commonly utilised for new patients than in aftercares (72% vs 50%). 75% of ECPs requested patients bring a list of their medication to appointments. Differential diagnosis questioning was thorough in most ECPs (87% of relevant questions asked). Attempts to optimise compliance included oral instruction (95% always) and written patient instructions (95% at least sometimes). Abbreviations were used by 39% of respondents (26% used ones provided by a professional body). Conclusion: There is scope for more consistency in history and symptom taking for contact lens consultations and recommendations are made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Methods: Thirty-nine subjects (22.1. ±. 3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16. h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Results: Lens fit assessments were not different between brands (P > 0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12. h (P <. 0.05), but remained stable from 12 to 16. h (P > 0.05). Movement-on-blink was unaffected by wear-time (F = 0.403, P = 0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r = -0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P > 0.01). Conclusions: Among the lenses tested, objective lens fit changed between 8. h and 12. h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically-powered RGP (rigid gas-permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15°) and translation (up to 1mm) from their ideal position. Methods: The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point-spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher-order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation. Results: In agreement with the results of other authors, the RGP lenses markedly reduced both lower-order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies. Conclusions: At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort. © 2012 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p <. 0.001). Horizontal lens centration was on average close to central as assessed both objectively and subjectively (p > 0.05). The 95% confidence interval of subjective repeatability was better than objective assessment (±0.128. mm versus ±0.168. mm, p = 0.417), but utilised only 78% of the objective range. Vertical centration assessed objectively showed a slight inferior decentration (0.371. ±. 0.381. mm) with good inter- and intrasession repeatability (p > 0.05). Movement-on-blink was lower estimated subjectively than measured objectively (0.269. ±. 0.179. mm versus 0.352. ±. 0.355. mm; p = 0.035), but had better repeatability (±0.124. mm versus ±0.314. mm 95% confidence interval) unless correcting for the smaller range (47%). Horizontal lag was lower estimated subjectively (0.562. ±. 0.259. mm) than measured objectively (0.708. ±. 0.374. mm, p <. 0.001), had poorer repeatability (±0.132. mm versus ±0.089. mm 95% confidence interval) and had a smaller range (63%). Subjective categorisation of push-up speed of recovery showed reasonable differentiation relative to objective measurement (p <. 0.001). Conclusions: The objective image analysis allows an accurate, reliable and repeatable assessment of soft contact lens fit characteristics, being a useful tool for research and optimisation of lens fit in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature suggests that diabetic patients may have altered tear chemistry and tear secretion as well as structural and functional changes to the corneal epithelium, endothelium and nerves. These factors, together with a reported increased incidence of corneal infection, suggest that diabetic patients may be particularly susceptible to developing ocular complications during contact lens wear. Reports of contact lens-induced complications in diabetic patients do exist, although a number of these reports concern patients with advanced diabetic eye disease using lenses on an extended wear basis. Over the past decade or so, there have been published studies documenting the response of the diabetic eye to more modern contact lens modalities. The results of these studies suggest that contact lenses can be a viable mode of refractive correction for diabetic patients. Furthermore, new research suggests that the measurement of tear glucose concentration could, in future, be used to monitor metabolic control non-invasively in diabetic patients. This could be carried out using contact lenses manufactured from hydrogel polymers embedded with glucose-sensing agents or nanoscale digital electronic technology. The purpose of this paper is to review the literature on the anterior ocular manifestations of diabetes, particularly that pertaining to contact lens wear. © 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lipids play a vital role in the body at many interfaces. Examples include the lubrication of articulating joints by synovial fluid, the coating of the lung by pulmonary surfactant and the functions of the tear film in the protection of the anterior eye. The role of the lipids is similar at each site - acting as boundary lubricants and reducing surface and interfacial tension. This review focuses on how and why contact lens wear can disrupt the normal function of lipids within the tear film and explains how the otherwise advantageous presence and function of tear lipids can become disadvantageous, causing problems for the wearer. Because the contact lens is some ten times thicker than the tear film, lipids deposited on the anterior surface become immobilised, reducing lipid turnover and thus leading to prolonged exposure to oxygen and light with consequent generation of degradation products. These degraded lipids reduce lens wettability and have additionally been linked to problems of contact lens discomfort and intolerance. Lipid problems are influenced by the thickness of the lens, the material, surface modification, mode of wear and ultimately the subject. The most influential of these variables is frequently the subject. © 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presbyopia is a consequence of ageing and is therefore increasing inprevalence due to an increase in the ageing population. Of the many methods available to manage presbyopia, the use of contact lenses is indeed a tried and tested reversible option for those wishing to be spectacle free. Contact lens options to correct presbyopia include multifocal contact lenses and monovision.Several options have been available for many years with available guides to help choose multifocal contact lenses. However there is no comprehensive way to help the practitioner selecting the best option for an individual. An examination of the simplest way of predicting the most suitable multifocal lens for a patient will only enhance and add to the current evidence available. The purpose of the study was to determine the current use of presbyopic correction modalities in an optometric practice population in the UK and to evaluate and compare the optical performance of four silicone hydrogel soft multifocal contact lenses and to compare multifocal performance with contact lens monovision. The presbyopic practice cohort principal forms of refractive correction were distance spectacles (with near and intermediate vision providedby a variety of other forms of correction), varifocal spectacles and unaided distance with reading spectacles, with few patients wearing contact lenses as their primary correction modality. The results of the multifocal contact lens randomised controlled trial showed that there were only minor differences in corneal physiology between the lens options. Visual acuity differences were observed for distance targets, but only for low contrast letters and under mesopic lighting conditions. At closer distances between 20cm and 67cm, the defocus curves demonstrated that there were significant differences in acuity between lens designs (p < 0.001) and there was an interaction between the lens design and the level of defocus (p < 0.001). None of the lenses showed a clear near addition, perhaps due to their more aspheric rather than zoned design. As expected, stereoacuity was reduced with monovision compared with the multifocal contact lens designs, although there were some differences between the multifocal lens designs (p < 0.05). Reading speed did not differ between lens designs (F = 1.082, p = 0.368), whereas there was a significant difference in critical print size (F = 7.543, p < 0.001). Glare was quantified with a novel halometer and halo size was found to significantly differ between lenses(F = 4.101, p = 0.004). The rating of iPhone image clarity was significantly different between presbyopic corrections (p = 0.002) as was the Near Acuity Visual Questionnaire (NAVQ) rating of near performance (F = 3.730, p = 0.007).The pupil size did not alter with contact lens design (F = 1.614, p = 0.175), but was larger in the dominant eye (F = 5.489, p = 0.025). Pupil decentration relative to the optical axis did not alter with contact lens design (F = 0.777, p =0.542), but was also greater in the dominant eye (F = 9.917, p = 0.003). It was interesting to note that there was no difference in spherical aberrations induced between the contact lens designs (p > 0.05), with eye dominance (p > 0.05) oroptical component (ocular, corneal or internal: p > 0.05). In terms of subjective patient lens preference, 10 patients preferred monovision,12 Biofinity multifocal lens, 7 Purevision 2 for Presbyopia, 4 AirOptix multifocal and 2 Oasys multifocal contact lenses. However, there were no differences in demographic factors relating to lifestyle or personality, or physiological characteristics such as pupil size or ocular aberrations as measured at baseline,which would allow a practitioner to identify which lens modality the patient would prefer. In terms of the performance of patients with their preferred lens, it emerged that Biofinity multifocal lens preferring patients had a better high contrast acuity under photopic conditions, maintained their reading speed at smaller print sizes and subjectively rated iPhone clarity as better with this lens compared with the other lens designs trialled. Patients who preferred monovision had a lower acuity across a range of distances and a larger area of glare than those patients preferring other lens designs that was unexplained by the clinical metrics measured. However, it seemed that a complex interaction of aberrations may drive lens preference. New clinical tests or more diverse lens designs which may allow practitioners to prescribe patients the presbyopic contact lens option that will work best for them first time remains a hope for the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The poor retention and efficacy of instilled drops as a means of delivering drugs to the ophthalmic environment is well-recognised. The potential value of contact lenses as a means of ophthalmic drug delivery, and consequent improvement of pre-corneal retention is one obvious route to the development of a more effective ocular delivery system. Furthermore, the increasing availability and clinical use of daily disposable contact lenses provides the platform for the development of viable single-day use drug delivery devices based on existing materials and lenses. In order to provide a basis for the effective design of such devices, a systematic understanding of the factors affecting the interaction of individual drugs with the lens matrix is required. Because a large number of potential structural variables are involved, it is necessary to achieve some rationalisation of the parameters and physicochemical properties (such as molecular weight, charge, partition coefficients) that influence drug interactions. Ophthalmic dyes and structurally related compounds based on the same core structure were used to investigate these various factors and the way in which they can be used in concert to design effective release systems for structurally different drugs. Initial studies of passive diffusional release form a necessary precursor to the investigation of the features of the ocular environment that over-ride this simple behaviour. Commercially available contact lenses of differing structural classifications were used to study factors affecting the uptake of the surrogate actives and their release under 'passive' conditions. The interaction between active and lens material shows considerable and complex structure dependence, which is not simply related to equilibrium water content. The structure of the polymer matrix itself was found to have the dominant controlling influence on active uptake; hydrophobic interaction with the ophthalmic dye playing a major role. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study identifies and investigates the potential use of in-eye trigger mechanisms to supplement the widely available information on release of ophthalmic drugs from contact lenses under passive release conditions. Ophthalmic dyes and surrogates have been successfully employed to investigate how these factors can be drawn together to make a successful system. The storage of a drug-containing lens in a pH lower than that of the ocular environment can be used to establish an equilibrium that favours retention of the drug in the lens prior to ocular insertion. Although release under passive conditions does not result in complete dye elution, the use of mechanical agitation techniques which mimic the eyelid blink action in conjunction with ocular tear chemistry promotes further release. In this way differentiation between passive and triggered in vitro release characteristics can be established. Investigation of the role of individual tear proteins revealed significant differences in their ability to alter the equilibrium between matrix-held and eluate-held dye or drug. These individual experiments were then investigated in vivo using ophthalmic dyes. Complete elution was found to be achievable in-eye; this demonstrated the importance of that fraction of the drug retained under passive conditions and the triggering effect of in-eye conditions on the release process. Understanding both the structure-property relationship between drug and material and in-eye trigger mechanisms, using ophthalmic dyes as a surrogate, provides the basis of knowledge necessary to design ocular drug delivery vehicles for in-eye release in a controllable manner.