989 resultados para Ana Carvalho
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to verify the reliability of the Brazilian Portuguese version of the instrument Cerebral Palsy: quality of life questionnaire for children: primary caregiver questionnaire (CP QOLChild: primary caregiver) translated and culturally adapted. Thus, the translation and cultural adaptation of the instrument was made, and then the procedures to verify its reliability were performed. The translated and culturally adapted questionnaire was answered by 30 caregivers of children with cerebral palsy and inter and intra-observer analysis followed. The data allowed the authors to identify an internal consistency rangering from 0.649 to 0.858, intra-observer reliability from 0.625 to 0.809 and inter-observer reliability from 0.498 to 0.903. The analysis suggests that the instrument has acceptable psychometry.
Resumo:
This paper aims to report on the University extension activities based on the principles of the Solidarity Economy, developed by teachers and students from several campuses of UNESP, in partnerships with other institutions and the communities involved. In addition to a brief history of the Solidarity Economy in Brazil, and the opportunities and challenges of Technological Incubators for Popular Cooperatives (ITCPs), the paper presents important considerations for an Institutional Program aimed at strengthening and expanding the role of such Incubators at UNESP.
Resumo:
Background: Oropharyngeal dysphagia is common in individuals after stroke. Taste and temperature are used in dysphagia rehabilitation. The influence of stimuli, such as taste and temperature, on swallowing biomechanics has been investigated in both healthy individuals and in individuals with neurological disease. However, some questions still remain unanswered, such as how the sequence of offered stimuli influences the pharyngeal response. The goal of the present study was to determine the influence of the sequence of stimuli, sour taste and cold temperature, on pharyngeal transit time during deglutition in individuals after stroke. Methods: The study included 60 individuals with unilateral ischemic stroke, 29 males and 31 females, aged 41–88 years (mean age: 66.2 years) examined 0–50 days after ictus (median: 6 days), with mild to moderate oropharyngeal dysphagia. Exclusion criteria were hemorrhagic stroke patients, patients with decreased level of consciousness, and clinically unstable patients, as confirmed by medical evaluation. The individuals were divided into two groups of 30 individuals each. Group 1 received a nonrandomized sequence of stimuli (i.e. natural, cold, sour, and sour-cold) and group 2 received a randomized sequence of stimuli. A videofluoroscopic swallowing study was performed to analyze the pharyngeal transit time. Four different stimuli (natural, cold, sour, and sour-cold) were offered. The images were digitalized and specific software was used to measure the pharyngeal transit time. Since the values did not present regular distribution and uniform variances, nonparametric tests were performed. Results: Individuals in group 1 presented a significantly shorter pharyngeal transit time with the sour-cold stimulus than with the other stimuli. Individuals in group 2 did not show a significant difference in pharyngeal transit time between stimuli. Conclusions: The results showed that the sequence of offered stimuli influences the pharyngeal transit time in a different way in individuals after stroke and suggest that, when the sour-cold stimulus is offered in a randomized sequence, it can influence the response to the other stimuli in stroke patients. Hence, the sour-cold stimulus could be used as a therapeutic aid in dysphagic stroke patients.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Purpose: The execution of adjustments on ceramic restorations is sometimes necessary for either correction of occlusion and/or inadequate contours or esthetical improvements. Clinically, the surfaces undergo weariness through fine grinding diamond burs which remove the superficial glazing layer. Several materials for ceramic polishing have been used in an attempt to reach a satisfactory surface smoothness. The aim of this study was to perform a literature review on different polishing protocols of several dental ceramics. Study selection: This is a literature review performed through scientific articles published between 2004 and 2012, indexed in MEDLINE, PubMed and Scielo databases. The study selected and analyzed a total of 20 relevant articles that evaluated different types of ceramics, polishing treatment and surface roughness.Results: After an extensive literature review, this study observed: 1 - after the rupture of the glazing layer due to the adjustments of the restorations, the best choice for the polishing of the surface will depend on the type of ceramics used; 2 - glazing procedure provide excellent results regarding to the superficial smoothness; however, if reglazing is impossible, either abrasive rubber cups/points or sandpaper discs followed by the use of diamond polishing pastes results in a satisfactory superficial smoothness; 3 - clinical studies that take into account the behavior of the protocols polishing are scarce and should be encouraged; 4 - the large number of variables influence the final outcome of polishing should be considered. Conclusions: The necessity in standardization of methodologies to enable a comparison among researches. (c) 2014 Japan Prosthodontic Society. Published by Elsevier Ireland. All rights reserved.
Resumo:
Preeclampsia (PE) is characterized by hypertension and proteinuria, occurring after the 20th week of pregnancy in women who have had no previous symptoms. The disease progresses with generalized vasoconstriction and endothelial dysfunction. Clinically, it is important to diagnose the severe form of the disease (sPE), in which blood pressure and proteinuria are much higher. Recently, the gestational age (GA) of the onset of PE has led to the classification of this disease as early (GA <34 weeks) and late (GA >= 34 weeks). Several genetic polymorphisms affecting endothelial nitric oxide synthase (eNOS) levels or function were described, including G894T (Glu298Asp), VNTR b/a (variable-number 27-bp tandem repeat) and T-786C (promoter) polymorphisms. Thus, the aim of this study was to compare the distribution of G894T, VNTR b/a and T-786C polymorphisms and their haplotypes in Brazilian early and late sPE, as well as in normotensive pregnant. A total of 201 women were evaluated, 53 with early sPE, 45 with late sPE and 103 as normotensive pregnant women. The frequency of 894T allele was higher in late sPE vs normotensive pregnant, and 894TT genotype was higher in late sPE vs early sPE and normotensive pregnant. For VNTR b/a polymorphism, higher frequencies of aa genotype and a allele were observed in early sPE vs late sPE and normotensive pregnant. Besides, the frequency of haplotype T-b-C was higher in late sPE vs early sPE and normotensive pregnant. Considering the results found for eNOS polymorphisms, it is possible to suggest that the functional alterations induced by these two polymorphisms may influence the time of severe PE onset, although both alterations are putatively associated with low NO bioavailability. However, other studies are necessary to validate these findings and clarify this issue. (C) 2014 Elsevier Inc. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Renal abscesses are rare in dogs and, although its pathogenesis is uncertain, may occur in diabetic patients with pyelonephritis, nephrolithiasis, kidney injuries or after abdominal surgery or kidney biopsy. Because of nonspecific clinical signs, laboratory tests associated with ultrasonography are important to confirm the diagnosis and treatment. Generally, kidney abscesses have sonographic aspects with different degrees of echogenicity such as hypo or hyperechoic, homogeneous or heterogeneous, and may or may not have thickened and hyperechoic walls, depending on its chronicity. Our objective was to report the use of ultrasound as a complementary method in the evaluation of disorders of the urinary tract, focusing on a case of renal abscess in a dog.