916 resultados para Advanced control systems
Resumo:
The chart of control of Hotelling T2 has been the main statistical device used in monitoring multivariate processes. Currently the technological development of control systems and automation enabled a high rate of collection of information of the production systems in very short time intervals, causing a dependency between the results of observations. This phenomenon known as auto correlation causes in the statistical control of the multivariate processes a high rate of false alarms, prejudicing in the chart performance. This entails the violation of the assumption of independence and normality of the distribution. In this thesis we considered not only the correlation between two variables, but also the dependence between observations of the same variable, that is, auto correlation. It was studied by simulation, the bi variate case and the effect of auto correlation on the performance of the T2 chart of Hotelling.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 10(34)cm(-2)s(-1) (10(27)cm(-2)s(-1)). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4 pi solid angle. Forward sampling calorimeters extend the pseudo-rapidity coverage to high values (vertical bar eta vertical bar <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.
Resumo:
Com o objetivo de avaliar os efeitos do método de preparo do solo e do controle de plantas daninhas em resteva de aveia preta (Avena strigosa), na cultura da soja (Glycine max cv. 'IAC 14'), foi conduzido um experimento de campo na Fazenda Experimental Lageado - UNESP Botucatu - SP, em 1993/94. Os tratamentos de manejo do solo foram Plantio Direto e Plantio Convencional (preparado com uma aração e três gradagens). As formas de controle de plantas daninhas estudadas corresponderam a uma testemunha sem controle do mato; controle com uso exclusivo de herbicidas aplicados em préemergência (0,28 kg/ha de metribuzim + 1,29 kg/ha de orizalin); controle com uso exclusivo de herbicidas aplicados em pósemergência (0,25 kg/ha de fluazifop-p-butil + 0,25 kg/ha de fomesafen); controle com o uso conjunto dos tratamentos em pré e pós-emergência mencionados. Tanto no plantio direto quanto no convencional, utilizou-se glyphosate para a eliminação da aveia preta e das plantas daninhas antes da implantação da cultura. O delineamento experimental adotado foi de blocos ao acaso em parcelas subdivididas, com quatro repetições. Os tipos de manejo do solo foram aplicados às parcelas e os métodos de controle das plantas daninhas às sub-parcelas. Deve ser ressaltado que durante a fase inicial do ensaio, as chuvas foram escassas, limitando tanto o crescimento da cultura quanto a atuação dos herbicidas de pré-emergência e pósemergência. As avaliações baseadas na contagem do número de plantas/m2, realizadas aos 14, 28 e 35 dias após a emergência da cultura da soja, indicaram diferenças entre os métodos de preparo do solo e os métodos de controle. Entre as espécies daninhas mais freqüentes, Brachiaria plantaginea e Amaranthus viridis foram as predominantes no sistema de plantio convencional; estas espécies apresentaram pequena importância no plantio direto, no qual predominou Euphorbia heterophylla. No plantio convencional, os herbicidas de pré-emergência proporcionaram melhor controle de A. viridis do que de B. plantaginea; o controle com herbicidas pós-emergentes foi insatisfatório para ambas espécies. No plantio direto, o controle de E. heterophylla foi insatisfatório em todos os sistemas de controle testados. O plantio direto apresentou sempre menor número total de plantas daninhas, sobretudo de gramineas. A germinação de plantas daninhas limitou-se ao período de até 15 dias após a emergência da cultura, nos dois sistemas de cultivo.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The application process of fluid fertilizers through variable rates implemented by classical techniques with feedback and conventional equipments can be inefficient or unstable. This paper proposes an open-loop control system based on artificial neural network of the type multilayer perceptron for the identification and control of the fertilizer flow rate. The network training is made by the algorithm of Levenberg-Marquardt with training data obtained from measurements. Preliminary results indicate a fast, stable and low cost control system for precision fanning. Copyright (C) 2000 IFAC.
Resumo:
This paper deals with the design and analysis of a Dynamic Voltage Restorer output voltage control. Such control is based on a multiloop strategy, with an inner current PID regulator and an outer P+Resonant voltage controller. The inner regulator is applied on the output inductor current. It will be also demonstrated how the load current behavior may influence in the DVR output voltage, which. justifies the need for the resonant controller. Additionally, it will be discussed the application of a modified algorithm for the identification of the DVR voltage references, which is based on a previously presented positive sequence detector. Since the studied three-phase DVR is assumed to be based on three identical H-bridge converters, all the analysis and design procedures were realized by means of single-phase equivalent circuits. The discussions and conclusions are supported by theoretical calculations, nonlinear simulations and some experimental results.
Resumo:
This paper presents a methodology and a tool for projects involving analogue and digital signals. A sub-systems group was developed to translation a Matlab/Simulink model in the correspondent structural model described in VHDL-AMS. The developed translation tool, named of MS(2)SV, can reads a file containing a Simulink model translating it in the correspondent VHDL-AMS structural code. The tool also creates the directories structure and necessary files to simulate the model translated in System Vision environment. Three models of D/A converters available commercially that use R-2R ladder network were studied. This work considers some of challenges set by the electronic industry for the further development of simulation methodologies and tools in the field of mixed-signal technology. Although the objective of the studies has been the D/A converter, the developed methodology has potentiality to be extended to consider control systems and mechatronic systems.
Resumo:
Titanium alloy parts are ideally suited for advanced aerospace systems and surgical implants because of their unique combination of high specific strength at both room temperature and moderately elevated temperature, in addition to excellent corrosion resistance. In this work, results of the Ti-35Nb alloy sintering are presented. This alloy, due to its lower modulus of elasticity and high biocompatibility, is a promising candidate for surgical and aerospace applications. Samples were produced by mixing of initial metallic hydride powders followed by uniaxial and cold isostatic pressing with subsequent densification by isochronal sintering between 700 and 1500 degrees C, in vacuum. Sintering behavior was studied by means of microscopy and density. Sintered samples were characterized for phase composition, microstructure and microbardness by X-ray diffraction, scanning electron microscopy and Vickers indentation, respectively. Samples sintered at high temperatures display a fine plate-like a structure and intergranular P. A few remaining pores are still found, and density above 97% for specimens sintered at 1500 degrees C is reached. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
An adaptive scheme is shown by the authors of the above paper (ibid. vol. 71, no. 2, pp. 275-276, Feb. 1983) for continuous time model reference adaptive systems (MRAS), where relays replace the usual multipliers in the existing MRAS. The commenter shows an error in the analysis of the hyperstability of the scheme, such that the validity of this configuration becomes an open question.
Resumo:
An algorithm for adaptive IIR filtering that uses prefiltering structure in direct form is presented. This structure has an estimation error that is a linear function of the coefficients. This property greatly simplifies the derivation of gradient-based algorithms. Computer simulations show that the proposed structure improves convergence speed.
Resumo:
Cogeneration system design deals with several parameters in the synthesis phase, where not only a thermal cycle must be indicated but the general arrangement, type, capacity and number of machines need to be defined. This problem is not trivial because many parameters are considered as goals in the project. An optimization technique that considers costs and revenues, reliability, pollutant emissions and exergetic efficiency as goals to be reached in the synthesis phase of a cogeneration system design process is presented. A discussion of appropriated values and the results for a pulp and paper plant integration to a cogeneration system are shown in order to illustrate the proposed methodology.
Resumo:
A field trial was carried out in Santa Rita do Passa Quatro, SP, on sandy soil, between February 1993 to February 1995, aiming to study the effects of fertilizer doses and brachiaria grass control on the growth of E. grandis. In the field the plots (9×9 plants, spacing 2×3 m) were located following a randomized block experimental design with four repetitions. The treatments were arranged in a factorial design with four systems of brachiaria grass control in the space between the Eucalyptus rows: mowing, cultivation, chemical control with glyphosate (2,08 kg eq. ác./ha) and hand hoeing were developed when the population reached the early flowering stage and four doses of the fertilizer 20-05-20: 0, 115, 230 and 345 kg/ha, handled at 3, 6 and 12 monthes after the transplantation. The hand hoeing was the most effective method of brachiaria grass control. However the hand hoeing controlled plots showed a decrease on the E. grandis growth exhibiting slower growth rate, shorter plants, thinner stems, smaller leaf area results and reduction on dry matter accumulation than the plants from the other plots under different weed control management's. The glyphosate promoted an excellent brachiaria grass control while the E. grandis plants grow better. Both remainder weed control management systems were intermediary in terms of efficacy. The mowing management was the most similar method as compared to the hand hoeing one and the cultivation treatments to the chemical control method. The growth rate differences observed between the hand hoeing and chemical control treatments were not caused directly by late fertilizations. There were no significative interactions among the weed control systems and the fertilization doses. Considering the brachiaria grass that grew between the E. grandis rows there were detected benefits to the crop and these effects increased when the chemical control was used for weed management.
Resumo:
The present work introduces a new strategy of induction machines speed adjustment using an adaptive PID (Proportional Integral Derivative) digital controller with gain planning based on the artificial neural networks. This digital controller uses an auxiliary variable to determine the ideal induction machine operating conditions and to establish the closed loop gain of the system. The auxiliary variable value can be estimated from the information stored in a general-purpose artificial neural network based on CMAC (Cerebellar Model Articulation Controller).
Resumo:
A branch and bound algorithm is proposed to solve the H2-norm model reduction problem for continuous-time linear systems, with conditions assuring convergence to the global optimum in finite time. The lower and upper bounds used in the optimization procedure are obtained through Linear Matrix Inequalities formulations. Examples illustrate the results.