981 resultados para Abnormal trading volume
Resumo:
BACKGROUND AND PURPOSE: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-APECTS) applied to CT angiography source images (CTA-SI) predicts the functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). We assessed the diagnostic and prognostic impact of pc-ASPECTS applied to perfusion CT (CTP) in the BASICS registry population. METHODS: We applied pc-ASPECTS to CTA-SI and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) parameter maps of BASICS patients with CTA and CTP studies performed. Hypoattenuation on CTA-SI, relative reduction in CBV or CBF, or relative increase in MTT were rated as abnormal. RESULTS: CTA and CTP were available in 27/592 BASICS patients (4.6%). The proportion of patients with any perfusion abnormality was highest for MTT (93%; 95% confidence interval [CI], 76%-99%), compared with 78% (58%-91%) for CTA-SI and CBF, and 46% (27%-67%) for CBV (P < .001). All 3 patients with a CBV pc-ASPECTS < 8 compared to 6/23 patients with a CBV pc-ASPECTS ≥ 8 had died at 1 month (RR 3.8; 95% CI, 1.9-7.6). CONCLUSION: CTP was performed in a minority of the BASICS registry population. Perfusion disturbances in the posterior circulation were most pronounced on MTT parameter maps. CBV pc-ASPECTS < 8 may indicate patients with high case fatality.
Resumo:
Tässä diplomityössä selvitetään EU:n alueella ja erityisesti Suomessa vuoden 2005 alusta alkavaa hiilidioksidin päästökauppaa. Työssä käsitellään päästökaupan tulevia vaikutuksia energia-, metalli- ja metsäteollisuuden kannalta. Myös kansantaloudelliset sekä kokonaistaloudelliset vaikutukset ovat mielenkiinnon kohteena. Työ koskee joiltakin osin myös ilmastonmuutoksen hillintää yleisesti ja ns. Kioton mekanismeja. Työn kuluessa pyritään myös ennakoimaan tulevan päästökaupan volyymia ja päästöyksikön eli hiilidioksiditonnin hintaa, joka on suurimpia epävarmuustekijöitä koko prosessissa. Tulevaa päästökauppaa tarkastellaan myös päästökauppadirektiivin, päästökauppalain ja muiden sitä koskevien lakien säännösten ja määräysten luomassa toimintakehikossa. Työn nimi "Päästökauppa murrosvaiheessa" kuvastaa täten myös sitä, että tarkastelussa ei pyritä välttämättä lopullisiin ja varmoihin tai tarkkoihin arvioihin, koska se on käytännössä mahdotonta. Työn painopiste onkin meneillään olevan päästökaupan valmistelun selvittely monimuotoisena prosessina, jolloin tämän prosessin kuvaus on suurelta osin tässä vaiheessa myös kvalitatiivista. Päästökaupan tulosten ja vaikutusten seuranta jatkossa puolestaan olisi mitä mielenkiintoisin jatkotutkimuksen aihe. Työtä havainnollistetaan kolmella käytännön case -esityksellä, jotka käsittelevät energiayritystä, kattila- ja laitetoimittajaa sekä metsäteollisuuden voimalaitosta, ja niiden varautumista alkavaan päästökauppaan.
Resumo:
Ihmisen toiminnan vaikutus ilmakehään johtaa todennäköisesti ilmastonmuutoksiin. Eräs näistä muutoksista on maapallon keskilämpötilan nousu, joka aiheutuu kasvihuonekaasujen lisääntyneestä pitoisuudesta ilmakehässä. Vaikutusten vähentämiseksi on hiilidioksidipäästöjä vähennettävä. Kioton pöytäkirja asettaa allekirjoittaneille maille päästövelvoitteet. Euroopan unionin tulee vähentää kasvihuonekaasupäästöjään 8%:lla. Eräs vähennysmekanismeista on päästökauppa. Päästökauppa on sekä keino suojella ympäristöä että ympäristöpoliittinen instrumentti kasvihuonekaasupäästövähennysten kustannusten keventämiseksi. Päästökauppa ei suoranaisesti vähennä kasvihuonekaasupäästöjä, vaan tasaa niitä maiden ja laitosten välillä. Uusiutuvan energian käytön edistäminen sekä kansainvälisesti että kansallisesti johtaa suoriin kasvihuonekaasupäästöjen vähenemiseen. Euroopan unionin jäsenvaltiot ovat asettaneet kansalliset viitearvot uusituvan sähkön kulutukselle. Saavuttaakseen nämä viitearvot maiden tulee tukea uusiutuvia energialähteitä eri menetelmin kuten vihreillä sertifikaateilla. Päästökauppa ja kaupattavat vihreät sertifikaatit tulevat vaikuttamaan energiantuottajien liiketoimintaan. Työssä on tutkittu päästökaupan ja vihreiden sertifikaattien vaikutuksia Vattenfall Kaukolämpö Oy:n, Vattenfall Sähköntuotanto Oy:n ja Vamy Oy:n liiketoimintaan.
Resumo:
In vertebrates, early brain development takes place at the expanded anterior end of the neural tube. After closure of the anterior neuropore, the brain wall forms a physiologically sealed cavity that encloses embryonic cerebrospinal fluid (E-CSF), a complex and protein-rich fluid that is initially composed of trapped amniotic fluid. E-CSF has several crucial roles in brain anlagen development. Recently, we reported the presence of transient blood-CSF barrier located in the brain stem lateral to the ventral midline, at the mesencephalon and prosencephalon level, in chick and rat embryos by transporting proteins, water, ions and glucose in a selective manner via transcellular routes. To test the actual relevance of the control of E-CSF composition and homeostasis on early brain development by this embryonic blood-CSF barrier, we block the activity of this barrier by treating the embryos with 6-aminonicotinamide gliotoxin (6-AN). We demonstrate that 6-AN treatment in chick embryos blocks protein transport across the embryonic blood-CSF barrier, and that the disruption of the barrier properties is due to the cease transcellular caveolae transport, as detected by CAV-1 expression cease. We also show that the lack of protein transport across the embryonic blood-CSF barrier influences neuroepithelial cell survival, proliferation and neurogenesis, as monitored by neurepithelial progenitor cells survival, proliferation and neurogenesis. The blockage of embryonic blood-CSF transport also disrupts water influx to the E-CSF, as revealed by an abnormal increase in brain anlagen volume. These experiments contribute to delineate the actual extent of this blood-CSF embryonic barrier controlling E-CSF composition and homeostasis and the actual important of this control for early brain development, as well as to elucidate the mechanism by which proteins and water are transported thought transcellular routes across the neuroectoderm, reinforcing the crucial role of E-CSF for brain development.
Resumo:
Background & Aims: Patients with cirrhosis develop abnormal hematologic indices (HI) from multiple factors, including hypersplenism. We aimed to analyze the sequence of events and determine whether abnormal HI has prog-nostic significance. Methods: We analyzed a database of 213 subjects with compensated cirrhosis without esopha-geal varices. Subjects were followed for approximately 9 years until the development of varices or variceal bleeding or completion of the study; 84 subjects developed varices. Abnormal HI was defined as anemia at baseline (hemoglo-bin,<13.5 g/dL for men and 11.5 g/dL for women), leuko-penia (white blood cell counts,<4000/mm 3 ), or thrombo-cytopenia (platelet counts, < 150,000/mm 3 ). The primary end points were death or transplant surgery. Results: Most subjects had thrombocytopenia at baseline. Kaplan-Meier analysis showed that leukopenia occurred by 30 months (95% confidence interval, 18.5-53.6), and anemia occurred by 39.6 months (95% confidence interval, 24.1-49.9). Baseline thrombocytopenia (P .0191) and leukope-nia (P.0383) were predictors of death or transplant, after adjusting for baseline hepatic venous pressure gradient (HVPG), and Child-Pugh scores. After a median of 5 years,a significant difference in death or transplant, mortality,and clinical decompensation was observed in patients who had leukopenia combined with thrombocytopenia at base- line compared with patients with normal HI (P < .0001). HVPG correlated with hemoglobin and white blood cell count (hemoglobin, r 0.35, P < .0001; white blood cell count, r 0.31, P < .0001). Conclusions: Thrombocy-topenia is the most common and first abnormal HI to occurin patients with cirrhosis, followed by leukopenia and anemia. A combination of leukopenia and thrombocytopenia at baselin predicted increased morbidity and mortality.
Resumo:
BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.
Resumo:
Tämä työ käsittelee puutukkien tilavuuden mittaamista värikonenäön avulla. Värikuvat on saatu Simpeleellä olevan metsäteollisuusyrityksen hiomosta. Työssä esitetään perusteellisesti matemaattinen teoria, joka liittyy käytettyihin kuvankäsittelymenetelmiin, kuten luokitteluun, kohinan poistoon ja tukkien segmentointiin. Esitetyt menetelmät implementointiin käytännössä ja eri menetelmillä saatuja tuloksia vertailtiin keskenään. Kuvankäsittelyalgoritmit on implementoitu Matlab 6.0:n avulla. Pääasiassa käytettiin uusinta Image Processing Toolboxia, joka on versio 3.0. Tämä työn näkökulma on pääasiassa käytäntöön soveltava, koska metsäteollsuus on korkealla tasolla Suomessa ja siellä on paljon alan yrityksiä, joissa tässä työssä kehitettyä menetelmää voidaan hyödyntää.
Resumo:
A Agricultura de Precisão (AP) permite a utilização de diferentes ferramentas na obtenção de informações, e estas otimizam a tomada de decisão por parte do produtor, impactando positivamente na receita final. O objetivo do trabalho foi verificar o comportamento das variáveis produção (PROD), volume de copa (VC) e diâmetro de caule (DC) da variedade Maxi Gala com a utilização da técnica da cokrigagem. O experimento foi conduzido em uma área de 0,90 hectare de produção comercial da variedade Maxi Gala, na Fazenda São Paulino, da empresa RASIP, em Vacaria-RS, apresentando como coordenadas geográficas 28º31’17” de latitude sul e 50º49’17” de longitude oeste, durante as safras de 2010/2011 e 2011/2012. Coletaram-se 75 amostras para cada variável, em uma malha de 12 m na entrelinha e 10 m na linha. As variáveis avaliadas foram produção por planta , volume de copa e diâmetro de caule. Foram feitas a análise estatística descritiva dos dados e a análise espacial através dos semivariogramas. De posse dos modelos ajustados, realizou-se a interpolação pelo método da krigagem. Após, foi realizada a correlação simples dos parâmetros e elaborado os semivariogramas cruzados para interpolação, pela técnica da cokrigagem. Os parâmetros PROD versus DCapresentaram média correlação na variedade Maxi Gala, na safra de 2011. Nas safras de 2011 e 2012, os parâmetros VC versus DC também apresentaram média correlação. A técnica da cokrigagem pode ser uma ferramenta daAP a ser utilizada pela cultura da macieira no levantamento de informações.Verificou-se que houve resposta e redução na coleta de amostras das variáveis mais difíceis; na safra de 2011, reduziu-se a coleta de 15 amostras da PROD, e na safra de 2012, reduziu-se a coleta de 20 amostras do VC.
Resumo:
OBJETIVO: Avaliar as artérias cervicais (carótidas e vertebrais) por meio da angio-RM, utilizando-se diferentes dosagens e diluições de contraste paramagnético. MATERIAIS E MÉTODOS: Estudo prospectivo em 15 pacientes, com análise de 30 artérias carótidas comuns, 30 artérias carótidas internas, 30 artérias carótidas externas e 30 artérias vertebrais, utilizando-se diferentes volumes e dosagens de contraste paramagnético: grupo I - dose única (14 ml de Gd-DTPA); grupo II -dose dupla (28 ml de Gd-DTPA); grupo III - dose única e diluída a 50%. A injeção de contraste foi realizada com a utilização de bomba injetora e com velocidades de injeção de 2 ml/s (grupo I) e 3 ml/s (grupos II e III). Os segmentos arteriais foram analisados por três examinadores em consenso de forma subjetiva, avaliando-se o grau de visibilidade, intensidade de contrastação e definição de seus contornos. RESULTADOS: Em todos os itens analisados os pacientes do grupo II apresentaram melhor resultado (visibilização total, boa contrastação dos vasos e contornos bem definidos). No grupo I houve boa visibilização das artérias carótidas e vertebrais, porém a intensidade de contraste e a definição dos contornos apresentaram variabilidade qualitativa. O grupo III apresentou os piores resultados, com dificuldade de visibilização, intensidade de contrastação baixa e contornos mal definidos. CONCLUSÃO: Entre os grupos analisados, a técnica utilizando dose dupla de gadolínio é a que permite melhor avaliação das artérias cervicais. A utilização de contraste diluído prejudica a avaliação dos vasos do pescoço.
Resumo:
Tutkielmassa analysoitiin yhteensä 73:n teknisen analyysin menetelmävariaation ja samalta ajanjaksolta lasketun osta ja pidä -strategian tuottojen eroja aineistolla, joka koostui 43 Helsingin Arvopaperipörssin päälistalla vuodesta 1991 vuoteen 1998 noteeratun yhtiön osakkeiden päivän päätöskursseista. Empiiriset testit toteutettiin tutkielmaa varten laadituilla Pascal-ohjelmilla, joilla simuloitiin eri teknisen analyysin menetelmien mukaista päivittäistä kaupankäyntiä. Tulokset osoittivat, ettei teknisen analyysin menetelmien avulla olisi tarkasteluperiodilla päässyt osta ja pidä -strategian tuottotasolle, sillä ainoastaan yksi strategioista ylitti osta ja pidä -strategian tuottotason. Negatiivinen korrelaatio kunkin teknisen analyysin menetelmän tuottamien kauppojen lukumäärän ja strategian kannattavuuden välillä oli erittäin vahva; mitä suurempi signaaliherkkyys, sitä heikompi oli kyseisen strategian tulos. Tutkimustulokset tukivat siten markkinatehokkuuden heikkojen ehtojen hypoteesia, jonka mukaan mennyt hintainformaatio ei ole monetäärisesti hyödynnettävissä.
Resumo:
PURPOSE: To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2 -preparation module ("2D-T2 -Prep"). METHODS: An adiabatic T2 -Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2 -prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2 -prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. RESULTS: In vivo, full field-of-view 2D-T2 -Prep significantly improved vessel sharpness as compared to conventional T2 -Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. CONCLUSION: When compared with conventional T2 -Prep, the 2D-T2 -Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition.
Resumo:
OBJECTIVES: The aims of the study were to use cone beam computed tomography (CBCT) images of nasopalatine duct cysts (NPDC) and to calculate the diameter, surface area, and 3D-volume using a custom-made software program. Furthermore, any associations of dimensions of NPDC with age, gender, presence/absence of maxillary incisors/canines (MI/MC), endodontic treatment of MI/MC, presenting symptoms, and postoperative complications were evaluated. MATERIAL AND METHODS: The study comprised 40 patients with a histopathologically confirmed NPDC. On preoperative CBCT scans, curves delineating the cystic borders were drawn in all planes and the widest diameter (in millimeter), surface area (in square millimeter), and volume (in cubic millimeter) were calculated. RESULTS: The overall mean cyst diameter was 15 mm (range 7-47 mm), the mean cyst surface area 566 mm(2) (84-4,516 mm(2)), and the mean cyst volume 1,735 mm(3) (65-25,350 mm(3)). For 22 randomly allocated cases, a second measurement resulted in a mean absolute aberration of ±4.2 % for the volume, ±2.8 % for the surface, and ±4.9 % for the diameter. A statistically significant association was found for the CBCT determined cyst measurements and the need for preoperative endodontic treatment to MI/MC and for postoperative complications. CONCLUSION: In the hands of a single experienced operator, the novel software exhibited high repeatability for measurements of cyst dimensions. Further studies are needed to assess the application of this tool for dimensional analysis of different jaw cysts and lesions including treatment planning. CLINICAL RELEVANCE: Accurate radiographic information of the bone volume lost (osteolysis) due to expansion of a cystic lesion in three dimensions could help in personalized treatment planning.